• Title/Summary/Keyword: Initial stiffness

Search Result 728, Processing Time 0.025 seconds

Impact Properties of CFRP Laminates with Initial Fiber Failures (강화재파단이 있는 복합재료의 저속 충격특성)

  • Park, Joong-Gwun;Kang, Chang-Kyu;Kim, Chul;Kim, Tae-Woo
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2005.04a
    • /
    • pp.67-70
    • /
    • 2005
  • The carbon fiber reinforced/epoxy laminated composites were fabricated with initial fiber failures within the unidirectional fiber pre-pregnated ply. The fiber failures were made intentionally either parallel to and/or perpendicular to the unidirectional fibers within the ply. The pre-made clear-cut cracks were found to be healed partially after laminating process. The laminates were impacted with or without initial fiber failures within the laminates. The force versus deflection curves were compared. The partially healed laminates showed the reduced laminate stiffness as compared to those without any intentional fiber failures. The impact curves were compared with size and the location of the initial failures varied.

  • PDF

Effective stiffness in regular R/C frames subjected to seismic loads

  • Micelli, Francesco;Candido, Leandro;Leone, Marianovella;Aiello, Maria Antonietta
    • Earthquakes and Structures
    • /
    • v.9 no.3
    • /
    • pp.481-501
    • /
    • 2015
  • Current design codes and technical recommendations often provide rough indications on how to assess effective stiffness of Reinforced Concrete (R/C) frames subjected to seismic loads, which is a key factor when a linear analysis is performed. The Italian design code (NTC-2008), Eurocode 8 and ACI 318 do not take into account all the structural parameters affecting the effective stiffness and this may not be on the safe side when second-order $P-{\Delta}$ effects may occur. This paper presents a study on the factors influencing the effective stiffness of R/C beams, columns and walls under seismic forces. Five different approaches are adopted and analyzed in order to evaluate the effective stiffness of R/C members, in accordance with the scientific literature and the international design codes. Furthermore, the paper discusses the outcomes of a parametric analysis performed on an actual R/C building and analyses the main variables, namely reinforcement ratio, axial load ratio, concrete compressive strength, and type of shallow beams. The second-order effects are investigated and the resulting displacements related to the Damage Limit State (DLS) under seismic loads are discussed. Although the effective stiffness increases with steel ratio, the analytical results show that the limit of 50% of the initial stiffness turns out to be the upper bound for small values of axial-load ratio, rather than a lower bound as indicated by both Italian NTC-2008 and EC8. As a result, in some cases the current Italian and European provisions tend to underestimate second-order $P-{\Delta}$ effects, when the DLS is investigated under seismic loading.

정수압 저어널 베어링의 동특성 향상에 관한 연구

  • 양문호;이기영;안유민;한동철
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1996.10a
    • /
    • pp.195-201
    • /
    • 1996
  • The dynamic characteristics of externally pressurized journal bearing have been studied theoretically. The Reynolds' equation has been solved by FDM, and the dynamic coefficients have been calculated by using perturbation method. The bearing is compensated by orifice or double-pad diaphragm control valve. The effects of diaphragm initial gap and stiffness are considered. As the results of analysis, it is shown that a control valve has better performance than orifice.

  • PDF

Dynamic Nonlinear Analysis of Marine Cables Under Wave Force and Earthquake Force (파랑하중 및 지진하중을 받는 해양케이블의 동적 비선형 해석)

  • 김문영
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1999.04a
    • /
    • pp.292-299
    • /
    • 1999
  • In order to investigate dynamic behaviors of marine cables under wave and earthquake forces a geometric nonlinear. F, E formulation of marine cables is presented and tangent stiffness and mass matrices for the isoparametric cable element are derived, The initial equilibrium state of cables subjected to self -weights and current forces is determined and free vibration and dynamic nonlinear analysis of cable structures under additional environmental loads are performed based on the initial configuration Challenging examples are presented and discussed in order to demonstrate the feasibility of the present finite element method and investigate dynamic nonlinear behaviors of marine cables.

  • PDF

An Estimating Method for Post-cyclic Strength and Stiffness of Eine-grained Soils in Direct Simple Shear Tests (직접단순전단시험을 이용한 동적이력 후 세립토의 강도 및 강성 예측법)

  • Song, Byung-Woong;Yasuhara, KaBuya;Murakami, Satoshi
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.2
    • /
    • pp.15-26
    • /
    • 2004
  • Based on an estimating method for post-cyclic strength and stiffness with cyclic triaxial tests proposed by one of the authors, cyclic Direct Simple Shear (DSS) tests were carried out to confirm whether the method can be adapted to DSS test on fine-grained soils: silty clay, plastic silt, and non-plastic silt. Results from cyclic and post-cyclic DSS tests were interpreted by a modified method as adopted for cyclic and post-cyclic triaxial tests. In particular, influence of plasticity index for fine-grained soils and initial static shear stress (ISSS) was emphasised. Findings obtained from the present study are: (i) liquefaction strength ratio of fine-grained soils decreases with decreasing plasticity index and increasing ISSS; (ii) plasticity index and ISSS did not markedly influence relation between equivalent cyclic stiffness and shear strain relations; (iii) the higher the plasticity index of fine-grained soils is, the less the strength ratio decreases with increment of a normalcies excess pore water pressure (NEPWP); (iv) stiffness ratio of plastic silt has large activity decrease rapidly with increasing excess pore water pressure; and (v) post-cyclic strength and stiffness results from DSS tests agree well with those predicted by the method modified from a procedure used for triaxial test results.

Behavior of Traditional Wood Frames Under Earthquake Loading (전통 목조 프레임구조의 지진하중에 대한 거동 특성)

  • 홍성걸
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.10a
    • /
    • pp.304-313
    • /
    • 2000
  • This study presents the behavior of traditional wood structures of national heritage under earthquake loadings. A series of experimental program for four wood frames was performed to investigate characteristics of initial stiffness, behavior after ultimate loads, and hysteretic behaviors. The frames consisted of columns with a lintel by special joint and a bare frame was infilled by a mud wall. A pushover est was aimed to estimate the range of ultimate rotation of connection as a pilot test for cyclic load tests. One of frames infilled by a mud wall showed a larger stiffness than those of bare frames due to a strut action in the diagonal direction. However, the post yielding stiffness of the infilled frame was not increased.

  • PDF

An Experimental Study III on the Bolted Connection between H-Beam and Precast-Concrete Column (PC 기둥-H형강보의 볼트접합부에관한 실험적 연구III)

  • Yeo, In-Seok;Park, Soon-Kyu
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.307-310
    • /
    • 2005
  • The PCS system, which consists of precast concrete column and steel beam, has been under development. Experimental test has been carried out to investigate the structural performance of the system under earthquake. Two types of test specimens of beam-column joints are designed in order to compare the performances. One is the system with reinforced concrete slab and the other is without slab. It is found that the system with slab could satisfy all of the requirements from ACI Criteria such as strength, stiffness degradation and energy dissipation capacity except initial stiffness. It is also investigated that the stiffness of the joint is belong to rigid joint type according to Bjorhovde criterion. And it is observed that the partial-composite system between beam and slab is more effective than full-composite system in the respect of the energy dissipation capacity of the system.

  • PDF

Inelastic Behavior of the SRC Column (SRC 합성교각의 비탄성 거동)

  • Jung, In-Keun;Min, Jin;Shim, Chang-Su;Chung, Young-Soo
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2005.03a
    • /
    • pp.300-307
    • /
    • 2005
  • Steel Reinforced Concrete (SRC) composite column has several advantage such as excellent durability, rapid construction, reduction of column section. Due to these aspect, applications of SRC columns to bridge piers are continuously increasing. For the design of relatively large SRC columns for bridge piers, it is necessary to check the current design provisions which were based on small section having higher steel ratio. In this study, seven concrete encased composite columns were fabricated and static tests were performed. Embedded steel members were a H-shape rolled beam and a partially filled steel tube. Based on the test results, the ultimate strength according to section details and local behavior were estimated. For the analysis of inelastic behavior of the SRC column, the cracked section stiffness of the columns was evaluated and compared with calculations. The stiffness of the cracked section showed that 25% of the initial value and this stiffness reduction occurred at 85% of the ultimate load in the experiments.

  • PDF

Design of a Swing-arm Actuator using the Compliant Mechanism - Multi-objective Optimal Design Considering the Stiffness Effect (컴플라이언트 메커니즘을 이용한 스윙 암 액추에이터의 설계 - 강성 효과를 고려한 다중목적 최적화 설계 -)

  • Lee Choong-yong;Min Seungjae;Yoo Jeonghoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.2 s.245
    • /
    • pp.128-134
    • /
    • 2006
  • Topology optimization is an effective scheme to obtain the initial design concept: however, it is hard to apply in case of non-linear or multi-objective problems. In this study, a modified topology optimization method is proposed to generate a structure of a swing arm type actuator satisfying maximum compliance as well. as maximum stiffness using the multi-objective optimization. approach. The multi-objective function is defined to maximize the compliance in the direction of focusing of the actuator and the second eigen-frequency of the structure. The design of experiments are performed and the response surface functions are formulated to construct the multi-objective function. The weighting factors between conflicting functions are determined by the back-error propagation neural network and the solution of multi-objective function is acquired using the genetic algorithm.

A Study on the Shape Optimization of the Cable-Truss Hybrid Structures (케이블-트러스 복합구조물의 형상최적화에 관한 연구)

  • Han, Sang-Eul;Jo, Nam-Chul
    • Journal of Korean Association for Spatial Structures
    • /
    • v.3 no.3 s.9
    • /
    • pp.75-83
    • /
    • 2003
  • The purpose of this study is to obtain the optimum shape of cable domes by using the real coding genetic algorithm. Generally, the structural performance of the cable domes is influenced very sensitively by pre-stress, geometry and length of the mast because of flexible system. So, it is very important to decide the optimum shape to get maximum stiffness of cable domes. We use the analytical model to verify the usefulness of this algorithm for shape optimization and analyze the roof system of Seoul olympic gymnastic arena as analytical model of a practical structures. It is confirmed lastly that the optimum shape domes have more stiffness than initial shape ones.

  • PDF