• Title/Summary/Keyword: Initial power drop

Search Result 27, Processing Time 0.03 seconds

A Study on Environmental and Economic Cost Analysis of Coal Thermal Power Plant Comparing to LNG Combined Power Plant (석탄화력발전대비 LNG복합화력발전 환경성 및 경제성 비용분석에 관한 연구)

  • Kim, Jong-Won
    • Asia-Pacific Journal of Business
    • /
    • v.9 no.4
    • /
    • pp.67-84
    • /
    • 2018
  • This study is about comparing coal thermal plant to LNG combined power plant in respect of environmental and economic cost analysis. In addition sensitive analysis of power cost and discount rate is conducted to compare the result of change in endogenous and exogenous variable. For environmental assessment, when they generate 10,669GWh yearly, coal thermal power plant emits sulfur oxides 959ton, nitrogen oxide 690ton, particulate matter 168ton and LNG combined power plant emits only nitrogen oxide 886ton respectively every year. Regarding economic cost analysis on both power plants during persisting period 30 years, coal thermal power plant is more cost effective 4,751 billion won than LNG combined taking in account the initial, operational, energy and environmental cost at 10,669GWh yearly in spite of only LNG combined power plant's energy cost higher than coal thermal. In case of sensitive analysis of power cost and discount rate, as 1% rise or drop in power cost, the total cost of coal thermal power plant increases or decreases 81 billion won and LNG combined 157 billion won up or down respectively. When discount rate 1% higher, the cost of coal thermal and LNG combined power plant decrease 498 billion won and 539 billion won for each. When discount rate 1% lower, the cost of both power plant increase 539 billion won and 837 billion won. With comparing each result of change in power cost and discount rate, as discount rate is weigher than power cost, which means most influential variable of power plan is discount rate one of exogenous variables not endogenous.

Inertial Control of a DFIG-based Wind Power Plant using the Maximum Rate of Change of Frequency and the Frequency Deviation

  • Lee, Hyewon;Kim, Jinho;Hur, Don;Kang, Yong Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.496-503
    • /
    • 2015
  • In order to let a wind generator (WG) support the frequency control of a power system, a conventional inertial control algorithm using the rate of change of frequency (ROCOF) and frequency deviation loops was suggested. The ROCOF loop is prevailing at the initial stage of the disturbance, but the contribution becomes smaller as time goes on. Moreover, its contribution becomes negative after the frequency rebound. This paper proposes an inertial control algorithm of a wind power plant (WPP) using the maximum ROCOF and frequency deviation loops. The proposed algorithm replaces the ROCOF loop in the conventional inertial control algorithm with the maximum ROCOF loop to retain the maximum value of the ROCOF and eliminate the negative effect after the frequency rebound. The algorithm releases more kinetic energy both before and after the frequency rebound and increases the frequency nadir more than the conventional ROCOF and frequency loops. The performance of the algorithm was investigated under various wind conditions in a model system, which includes a doubly-fed induction generator-based WPP using an EMTP-RV simulator. The results indicate that the algorithm can improve the frequency drop for a disturbance by releasing more kinetic energy.

Voltage Control of Power System Connected to a Wind Farm by Using STATCOM and Reactive Power Compensators (STATCOM과 조상설비를 이용한 풍력단지가 연계된 전력계통의 전압제어)

  • Seo, Gyu-Seok;Park, Ji-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.4
    • /
    • pp.2737-2743
    • /
    • 2015
  • The wind power plant must be able to produce reactive power at the POI bus of a wind farm connected to power system to keep or control the voltage of POI bus. But, the reactive power capability of wind turbines may not be sufficient to control the voltage of POI bus due to the reactive power losses in connection lines between wind farm and POI bus. The solution of this problem is to install an external STATCOM. The proposed cooperative control method of STATCOM and conventional reactive power compensators such as Switched-shunt and tap changing transformer can control the voltage of POI bus more efficiently. The simulation results are shown that the voltage drop of POI Bus of Test System with the arbitrary load change rate to initial loads is improved more than 60% and the voltage of load bus is maintained more than 95% of rated voltage.

Analysis of Dynamic Behavior in GMAW System (GMA용접 시스템의 동적 거동에 대한 해석)

  • 이재영;최재형;이지혜;유중돈
    • Journal of Welding and Joining
    • /
    • v.18 no.5
    • /
    • pp.41-48
    • /
    • 2000
  • Dynamic behaviors of the GMAW system are simulated using the short-circuit transfer model and the characteristic equations fir the power supply, wire system and arc. The conventional wire equation, which relates the rate change of the wire extension to the wire feed rate and melting rate, is modified to include effects of the molten drop attached at the wire tip. The modified wire equation describes behaviors of the GMAW system more precisely and provides information about the initial bridge volume for short-circuit transfer. The proposed short-circuit model predicts the variation of parameters such as the current, voltage, short-circuit frequency and time considering the effects of the surface tension and electromagnetic force due to current. The calculated results are in broad agreements with the experimental results under the argon shielding condition.

  • PDF

Combustion Characteristics of High Moisture Indonesia Coal as a Pulverized Fuel at Thermal Power Plant (미분탄 화력발전소 연료로서 고수분 인도네시아탄의 연소특성)

  • Kim, Jae-Kwan;Lee, Hyun-Dong
    • Journal of the Korean Society of Combustion
    • /
    • v.14 no.3
    • /
    • pp.16-23
    • /
    • 2009
  • It is strongly desired for coal-fired power plants to utilize not only low-rank coals with high moisture contents, but also lowering cost with diversifying fuel sources. In this study, combustion characteristics of low rank coal with high moisture, and standard pulverized coals are experimentally investigated using TGA (Thermogravimetric Analysis) and DTF (drop tube furnace). The coals tested are three kinds of coal with moisture content ranging from 8.32 to 26.82%. The results show that under the air combustion condition, the burn-out time at TGA rises as moisture content increases, and standard pulverized coal with 8.32% moisture content showed the lowest activation energy of 55.73 kJ/mol. In case of the high amount of moisture, the combustion efficiency decreases due to evaporation heat loss, and unburned carbon in ash produced at combustion process in DTF increased. Aslo, initial deformation temperature of slag attached in alumina tube of DTF decreased with lowering the crytallinity of anorthite and augite. To improve the combustion reactivity and efficiency, it is effective to upgrade through drying the high moisture coal to moisture level (less than 10%) of standard pulverized coal.

  • PDF

Design Procedure for System in Package (SIP) Business

  • Kwon, Heung-Kyu
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2003.09a
    • /
    • pp.109-119
    • /
    • 2003
  • o In order to start SIP Project .Marketing (& ASIC team) should present biz planning, schedule, device/SIP specs., in SIP TFT prior to request SIP development for package development project. .In order to prevent (PCB) revision, test, burn-in, & quality strategy should be fixed by SIP TFT (PE/Test, QA) prior to request for PKG development. .Target product price/cost, package/ test cost should be delivered and reviewed. o Minimum Information for PCB Design, Package Size, and Cost .(Required) package form factor: size, height, type (BGA, QFP), Pin count/pitch .(Estimated) each die size including scribe lane .(Estimated) pad inform. : count, pitch, configuration(in-line/staggered), (open) size .(Estimated) each device (I/O & Core) power (especially for DRAM embedded SIP) .SIP Block diagram, and net-list using excel sheet format o Why is the initial evaluation important\ulcorner .The higher logic power resulted in spec. over of DRAM Tjmax. This caused business drop longrightarrow Thermal simulation of some SIP product is essential in the beginning stage of SIP business planning (or design) stage. (i.e., DRAM embedded SIP) .When SIP is developed using discrete packages, the I/O driver Capa. of each device may be so high for SIP. Since I/O driver capa. was optimized to discrete package and set board environment, this resulted in severe noise problem in SIP. longrightarrow In this case, the electrical performance of product (including PKG) should have been considered (simulated) in the beginning stage of business planning (or design).

  • PDF

Characterization of Photovoltaic Module Encapsulant According to UV Irradiation Dose (자외선 조사량에 따른 태양전지 모듈 봉지재의 특성 분석)

  • Lee, Song-Eun;Bae, Joon-Hak;Shin, Jae-Won;Jeon, Chan-Wook
    • Current Photovoltaic Research
    • /
    • v.6 no.3
    • /
    • pp.81-85
    • /
    • 2018
  • The photovoltaic modules installed in the actual field are affected by various external environments and the electrical performance output value is generally lowered compared to initial output value. The most of photovoltaic modules consists of low iron glass, encapsulant (EVA), back sheet, frame and junction box assembly based on the solar cells. In this paper, the characteristics of encapsulant which is an important constituent material of photovoltaic module were verified by maximum power determination, electro luminescence images, yellowness index measurement, and gel content measurement after ultraviolet (UV) irradiation exposure. The most commonly installed 72 cells crystalline photovoltaic modules were tested after various UV exposure of 0, 15, 30, and $60kWh/m^2$ and compared with the reference module. After UV exposure of $15kWh/m^2$, which is the current international test condition, a small amount of change was observed in yellowness index and electroluminescence, while a gell content rapidly increased. At a cumulative dose of $60kWh/m^2$, which will be a new international test condition in the near future, however, the yellowness index increased sharply and showed the greatest output power drop.

A Magnetic Stimulator Adopting a Low-Frequency Fly-Back Switching Circuit (저주파 플라이백 스위칭회로를 이용한 고성능 자기자극기)

  • Yi, Jeong-Han;Kim, Hyung-Sik;Hur, Moon-Chang;Kim, Jung-Hoe
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.6
    • /
    • pp.343-350
    • /
    • 2006
  • Medical magnetic stimulator generates strong magnetic field pulses. Clinical applications of the magnetic pulse are the stimulation of nervous system and the contraction of muscle. The unique source of the strong magnetic pulse is a capacitor-inductor resonator and this inductor generates a strong sinusoidal magnetic pulse by discharging the capacitor with high initial voltage. Continuous muscle contraction needs sequential generation of the magnetic pulses. However, to keep the magnitude of sequential pulses identical, an expensive high-voltage power supply have to support voltage drop of the capacitor between the pulses. A protection circuit between the supply and the resonator is necessary to protect the supply from reverse current caused by capacitor voltage reversal. In this paper, a new circuit structure of the magnetic stimulator adopting a low-frequency fly-back switching is proposed. The new circuit supports sequential pulse generation and allows the reverse current without damage. Performance of the new circuit is examined and a low-cost magnetic stimulator for urinary incontinence therapy is being developed using the presented method.

Changes in Optical Properties of Crystalline-Si PV Modules after Natural Light Exposure (자연광 노출 후 결정질 실리콘 PV모듈의 광학적 특성 변화)

  • Kong, Ji-Hyun;Ji, Yang-Guen;Kang, Gi-Hwan;Yu, Gwon-Jong;Ahn, Hyung-Keun;Han, Deuk-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.64-64
    • /
    • 2010
  • This paper presents the results of changes of optical properties of front materials in crystalline PV modules. If PV modules on the outdoor, transmittance of front materials is reduced by solar light. That is UV, IR included Solar spectrum will have change the properties of glass. Therefore decrease in transmittance leads to loss of the PV modules output. All the PV modules showed the loss in Isc by 1~5% within few hors. To investigate the changes we are analyzed using spectrophotometer from raw glass to laminated glass.

  • PDF

A Study of Sports Socks Varying Knitted Fabrics on Hygienic and stability Properties (각종 편성소재에 따른 스포츠양말의 위생성과 형태안정성에 관한 연구)

  • 이명자;김칠순
    • The Research Journal of the Costume Culture
    • /
    • v.7 no.5
    • /
    • pp.165-176
    • /
    • 1999
  • The purpose of this study was to evaluate the effect of various knitted fabrics of sports socks on their properties of hygiene and stability. Seventeen men\`s sports socks to represent five groups with different fiber content, knit structure, yarn fineness, and finishing were used. Properties of hygiene and stability of socks were determined. The results were as follows ; 1. Evaluation of Water, vapor and heat transport properties in socks with varing fiber content showed that cotton 100% socks had the highest drop absorbency, wickability, water absorbency and water retention. Polypropylene 100% socks had an excellent wickability and moisture permeability. Acrylic blend socks had the highest thermal resistance. 2. The greatest knit stretch and knit growth of socks having lower power were found to be with cotton 100% socks had the lowest stretch. Acrylic blend socks had a excellent stretch but low fabric growth, which could give a good fir sensation during wear. 3. The commerical antimicrobial finished socks showed excellent durability after repeated cycles of laundering. 4. Length and width shrinkages were found in all laundered samples during initial cycles due to rearrangement by mechanical relaxation. Shrinkages showed no further changes and reached equilibriums after 5 cycles. Cotton 100% or cotton blend socks showed lower dimensional stability than other socks during fabric care.

  • PDF