• Title/Summary/Keyword: Initial permeability

Search Result 291, Processing Time 0.035 seconds

Exchange Coupling Effect on Microwave Permeability in CoFe/MnIr Bilayers (교환 결합력을 갖는 CoFe/MnIr 박막의 마이크로파 투자율 특성)

  • Kim, Dong-Young;Kim, Chong-Oh;Kim, Cheol-Gi;Tsunoda, M.;Takahashi, M.
    • Journal of the Korean Magnetics Society
    • /
    • v.16 no.5
    • /
    • pp.234-239
    • /
    • 2006
  • We measured the microwave permeability in the frequency range of 100 MHz$\sim$9 GHz in the exchange biased CoFe/MnIr films. The results were analyzed based on the Landau-Lifshitz-Gilbert theory. The initial permeability and ferromagnetic resonance frequency was tuned by controlling the CoFe thickness and unidirectional anisotropy. The tunable range of ferromagnetic resonance frequency was up to 20 GHz in the thin CoFe layer of 1.5 nm. The CoFe/MnIr films showed the high permeability and low loss properties in the microwave frequency range. Thus, this material could be applied to the microwave devices.

Studie8 on Long-Term Performance Evaluation of Geotextiles -for Filter and Drainage- (필터 및 배수용 토목섬유의 장기적 성능 평가에 관한 연구)

  • 권우남
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.35 no.3
    • /
    • pp.130-139
    • /
    • 1993
  • In order to evaluate the long-term permeability performace of the geotextiles, for five different combination of geotextiles and soils the long-term column test method The results obtained are as follows; 1.The gradient range of the initial stage of the long-term permeability curves varied with respect to the soil types, while that of the final stage varied according to the interaction of the soil/geotextile system. 2.The time required for a given soil/geotextile system to reach a interactive stable stage was measured ahout 100 hours for the standard sand and 150 to 600 hours for the silty content soils, respectively. 3.There were no differences between the plain woven geotextile and the non-geotextile in the long-term permeability performance. 4.As the silt content increased, the long-term performance of the geotextiles decreased, and the limiting silt content was about 15%. 5.The thickness and area density of the geotextiles did not influence on the variation of the seepage quantities. 6.The ayerage slope and the transition time of the long-time flow curve were calculated. 7.In order to evaluate the mechanism of soil/geotextile system more perfectly, the gradient ratio test or the hydraulic conductivity test is required.

  • PDF

Numerical Analyses about Test Results of Discharge Capacity Apparatus Using Penetration Method (관입식 통수능 실험의 수치해석)

  • Yoo, Nam-Jae;Woo, Young-Min;Jun, Sang-Hyun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.720-728
    • /
    • 2009
  • This thesis is results of numerical analyses about test results of discharge capacity apparatus using penetration method. Applicability of numerical approach with FEM technique, using Cam-clay model, was confirmed by analyzing the results of standard consolidation test before analyzing test results of discharge capacity apparatus using penetration method. Thus, input parameters for the model was convinced to be appropriate. For numerical analyses about test results of discharge capacity apparatus using penetration method, identical initial and loading conditions during tests were applied to simulate test results correctly. Effects of ground disturbance resulted from installment of vertical drains on the behaviors of consolidation were also simulated. Applicability of numerical approach was investigated by comparing test results with numerical ones. As results of them, both of consolidation settlement were found to be in good agreements so that its applicability was confirmed. As results of numerical estimation, degree of consolidation with the condition of considering smear zone was found to be delayed, compared with results without smear zone. On the other hands, parametric numerical analyses of changing parameters related to smear zone such as permeability and size of smear zone and permeability of vertical drain were also carried out.

  • PDF

Magnetic Properties of Ni-Cu-Zn Ferrite with varying Ni, Cu (Ni, Cu 변화에 따른 Ni-Cu-Zn Ferrite의 자기적 특성)

  • 백승철;정승우;김태원;김성수;최우성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.259-262
    • /
    • 1999
  • In this study, we investigated magnetic Properties of N $i_{0.2-x}$C $u_{x}$Z $n_{0.305}$F $e_{0.495}$ (x=0 ~0.2) ferrites. As the increased, the density and shrinkage increased until 5.3g/㎤, 20% respects, but the absorption decreased rate until 0.01%. As a results of the density, absorption rate, and shrinkage rate, the grain growth progressed rapidly in x=0.125 at 105$0^{\circ}C$, x=0.075 at 115$0^{\circ}C$, and x=0.025 at 115$0^{\circ}C$ for 3hours. As the CuO concentration increased, initial permeability increased at sintered 105$0^{\circ}C$ and 115$0^{\circ}C$ for 3 hours, but decreased at 125$0^{\circ}C$ for 3 hoers. The complex permeability as a function of frequency were high values at sintered 105$0^{\circ}C$ for 3 hours in x=0.005, 0.075.5.5.5.

  • PDF

A Study on the Horizontal Consolidation and Permeability Characteristics of Decomposed Mudstone Soil in Pohang (이암풍화토의 횡방향압밀 및 투수특성)

  • 김영수;김기영;백영식
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.1
    • /
    • pp.31-42
    • /
    • 2000
  • Consolidation and permeability are major engineering properties of soil. In clay, coefficient of permeability and consolidation can be calculated by incremental loading consolidation test. However, it is known that the incremental loading test has several deficiencies including long testing time, non-uniform stress state, very soft clay and problem of back pressure saturation. Specially, it is not performed with horizontal consolidation test. Several methods have been proposed for obtaining reliable values of $C_v$. Among these, the square root of time-fitting method proposed by Taylor(1948) and logarithm of time-fitting method, also called Casagrande's method, are used extensively in soil engineering practice. But these methods are not amenable for the absence of initial linear portion and have the difficulties involved in distinguishing secondary compression from primary compression. Rowecell consolidation tests were carried out in this study with different trimming axis and sample size. The results were compared with those of other methods; Casagrande,$Taylor,\; Casagrande,\; Hyperbolic,\; \delta/t-logt$. From the results, we explained a relationship between horizontal coefficient of permeability and void ratio was obtained. Finally, the directly measured horizontal coefficient of permeability obtained by using the Rowecell was compared with the permeability derived indirectly from the consolidation test result.

  • PDF

The Change in Geotechnical Properties of the Deposited Clay Contaminated by Leachate from Waste Disposals (침출수로 오염된 퇴적점토의 역학적 특성변화)

  • Ha, Kwang-Hyun;Lee, Sang-Eun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.7 no.3
    • /
    • pp.43-54
    • /
    • 2006
  • In this paper, the uniaxial, triaxial compression tests and consolidation tests on the clay sample substituted initial pore water for pollutant were performed to evaluate the change in geotechnical properties of the contaminated clay. The contaminant transport analysis on embankment type landfill using the MT3D model was also performed to evaluate the extent of transport and diffusion. There was tendency that strength, compressibility and permeability has increased with the increase in the concentration of NaCl solution. The increase in the strength and compressibility of sample saturated with leachate was higher than samples saturated with NaCl solution, but in the permeability coefficient was lower. As the result of contaminant transport analysis, the predicted concentration was in high with the increase in the initial concentration of $Cl^-$ ion and increased in a non-linear form. The transportation distance calculated with use of regression equation between the distance from contaminant source and the concentration of $Cl^-$ ion was increased with the increase in the initial concentration.

  • PDF

Purification During Crossflow Electromicrofiltration of Fermentation Broth

  • Park Young G.
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.9 no.6
    • /
    • pp.500-505
    • /
    • 2004
  • The present study was to investigate the purification of a fermentation broth by an electromicrofiltration membrane. Microfiltration runs with a crude and a centrifuged broth, with solution of particles recovered from centrifugation and with permeates from microfiltration experiments were thus compared. Microfiltration performances were governed by colloids and small particles that induced sharp initial flux declines. For these results, the evolution of the overall membrane resistance was increased by $80\%$ in comparison with the electromicrofiltration membrane. The main focus of this study was set on the enhancement of the filtrate flux by an electric field. This pressure electrofiltration leads to a drastic improvement of the filtration by $100\%$ and the filtration time was thereby reduced. Pressure electrofiltration serves as an inter­esting alternative to the cross-flow filtration and it effectively separates advantageous constitu­ents such as amino acids and biopolymers from a fermentation broth. They were equally main­tained during the microelectrofiltration, although they were significantly reduced by $45\%$ by the microfiltration without the application of an electric field. Accordingly, since the electrofiltration membrane was provided more permeability, this study experimentally demonstrates that the permeability inside a membrane can be controlled using an electric field.

RF Power Absorption Enhancement of Magnetic Composites with Conductive Grid

  • Nam, Baek-Il;Kim, Jin-U;Kim, Ki-Hyeon
    • Journal of Magnetics
    • /
    • v.17 no.2
    • /
    • pp.129-132
    • /
    • 2012
  • To evaluate the electromagnetic power absorption in near field, the magnetic composites with the conductive grids were simulated using the typical permeability frequency profiles. The transmission power absorptions of the magnetic composites on microstrip line were extracted by the 3D FEM simulation program of HFSS. The magnitudes of power absorptions were greatly enhanced up to 98% and broadened the absorbing frequency band over 5 GHz by the insertion of a conductive grid in magnetic composite. The initial frequency of the power absorption can controlled by the change of the ferromagnetic resonance frequencies of the magnetic composite.

Effects by Variation of Raw Materials on Physical Properties of Ni-Zn Ferrite (원료 변화에 따른 Ni-Zn Ferrite의 물리적 특성에 미치는 영향)

  • Koh, Jae-Gui
    • Korean Journal of Materials Research
    • /
    • v.16 no.9
    • /
    • pp.578-583
    • /
    • 2006
  • We studied the physical properties of Ni-Zn ferrites by adding different chemicals such as $SO_4$, Cl, and $NO_3$. Specimens were prepared by the coprecipitation method and sintered at temperatures $950^{\circ}C,\;1,150^{\circ}C,\;and\;1,350^{\circ}C$, respectively. X-ray diffractions showed a spinel structure and the optical microscopy revealed grain size of 0.3 to 0.6 ${\mu}m$. The optimum sintering temperature to obtain fine, sintered microstructure depended on the additive : Cl and $NO_3\;at\;950^{\circ}C\;and\;SO_4\;at\;1,150^{\circ}C$. According to particle size analysis, higher magnetic permeability and magnetization value were observed with Cl and $NO_3\;than\;SO_4$. As sintering temperature was raised from $950^{\circ}C$ to $1,350^{\circ}C$, the average grain diameter, initial permeability and the magnetic moment also increased.

Characteristics of Water Vapor Sorption Phenomena of Powdered Foods (건조분말 식품의 수분 특성에 관한 비교 연구)

  • 박길동;김동원
    • Journal of Ginseng Research
    • /
    • v.6 no.1
    • /
    • pp.30-37
    • /
    • 1982
  • This study was conducted to investigate the water vapor permeability of packaging film, Al- foil laminated paper, and sorption properties of dehydrated and powdered foods. The results are as fellows. 1. Absorption rate of each products was greately affeoted by physicochemical properties of foods rather than initial moisture contents of the products. 2. The absorption rate of each products were in the order of freeze dried coffee, spray dried coffee, freeze drie4 ginseng extract, spray dried ginseng extract, ginger tea, black tea, citrus juice Powder and ssang wha tea. 3. Most of the products such as freeze dried coffee, spray dried coffee, freeze dried ginseng extract, ginger tea and black tea have shorter than a month of shelf life. 4. The stability of the products were greatly affected by its desorption properties than the degree of desorption of moisture. 5. Water vapor permeability of packaging materials which are laminated Al-foil with polythylene and glassin paper were mainly affected of thickness of Al-foil and polyethylene.

  • PDF