• Title/Summary/Keyword: Initial operation characteristics

Search Result 281, Processing Time 0.021 seconds

Hysteresis Characteristics of a SFCL using a Magnetic Coupling of Coils with an Iron Core of Two Magnetic Paths (두 개의 자기경로 철심을 갖는 코일의 자기결합을 이용한 초전도 전류제한기의 히스테리시스 특성)

  • Lim, Sung-Hun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.12
    • /
    • pp.1073-1077
    • /
    • 2009
  • The iron core, which comprises the superconducting fault current limiter (SFCL) using magnetic coupling of coils, can be operated in the saturation region, especially at the initial fault period. This operation of the iron core in the saturation region deteriorates the fault current limiting operation of the SFCL. To solve the saturation problem of the SFCL using magnetic coupling of coils, the iron core with two magnetic paths, which has an air-gap in one of them, was adopted. In this paper, the hysteresis characteristics of SFCL using magnetic coupling of coils, which were wound in the iron core with two magnetic paths, were analyzed. Through comparative analysis on the hysteresis characteristics of the iron core comprising SFCL, the hysteresis characteristics of the iron core with two magnetic paths were confirmed to be kept in the non-saturation region during the fault period and thus, the effective fault current limiting operation of the SFCL using the magnetic coupling of coils could be performed.

Characteristics of the SFCL by turn-ratio of three-phase transformer

  • Jeong, I.S.;Choi, H.S.;Jung, B.I.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.4
    • /
    • pp.34-38
    • /
    • 2013
  • According to the increase of electric consumption nowadays, power system becomes complicated. Due to this, the size of single line-to-ground fault from power system also increases to have many problems. In order to resolve these problems effectively, an Superconducting Fault Current Limiter(SFCL) was proposed and continuous study has been done. In this paper, an SFCL was combined to the neutral line of a transformer. An superconductivity has the characteristics of zero resistance below critical temperature. because of this, SFCL has nearly zero resistance. so we connecting SFCL to neutral line will not only have any loss in the normal operation but also have the less burden of electric power because of only limiting the initial fault current. We analyzed the characteristics of current, voltage according to the changes of turn ratio of 3 phase system in case of combinations of an SFCL to the neutral line. It was confirmed that the limiting rate of initial fault current by the increase of turn ratio was reduced.

Interior Central Pole Search Coils for Initial Rotor Position Detection of a Toroidal SRM (토로이달 SRM의 초기 회전자 위치검출을 위한 돌극 관통 서치코일)

  • 양형열;임영철
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.7
    • /
    • pp.473-482
    • /
    • 2004
  • In this paper, a detection technique of initial rotor position at a standstill in Toroidal Switched Reluctance Motor(TSRM) with built-in interior central pole search coil is proposed. In case search coils are used as a position sensor, it has many advantages like low cost, decrease in the volume, high robust characteristics and wide applications. However, the initial rotor position detection is very difficult because the search coil's EMF is not exist at a standstill. In this paper, a new detection method of initial rotor position is suggested using interior central pole search coil. The simulation and experiment for the proposed method and their results support the validity of the proposed scheme by verifying the operation of a 6/4 TSRM using search coils.

A Study on the AHP Analysis of initial UAM Pilot Education and Training Subjects (초기 UAM 조종사 교육훈련 과목 선정 AHP 분석 연구)

  • Sung-yeob Kim;Jung-min Choi;Jihun Choi
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.3
    • /
    • pp.269-273
    • /
    • 2023
  • Based on the K-UAM roadmap, this study was conducted to select major education and training subjects necessary for the composition of the initial UAM pilot education and training curriculum. Currently, UAM aircraft have similar characteristics to rotorcraft that can take off and land vertically around VTOL functions. Therefore, in this study, the Rotary Wing Pilot Training Curriculum of the Army Aviation School, which represents Rotary Wing Flight Education, was selected as a comparative group, and education and training subjects for initial UAM pilot training were selected. First, a hierarchical structure for the AHP survey was designed based on the Army's rotorcraft pilot education and training subjects, and the AHP survey was conducted by selecting experts from each class. If the education and training subjects given as priorities through AHP analysis are applied to initial UAM pilot training, it is expected to contribute to the effect of education and training and ultimately to the safe operation of UAM.

Removal Characteristics of Cu(II) ion in Aqueous Solution by Solid-Phase Extractant Immobilized D2EHPA and TBP in PVC (D2EHPA와 TBP를 PVC에 고정화한 고체상 추출제를 사용한 수용액 중의 Cu(II) 이온 제거특성)

  • Kam, Sang-Kyu;Lee, Song-Woo;Lee, Min-Gyu
    • Journal of Environmental Science International
    • /
    • v.24 no.1
    • /
    • pp.47-53
    • /
    • 2015
  • Removal characteristics of Cu(II) ions by solid-phase extractant immobilized D2EHPA and TBP in PVC were investigated. Cu(II) ion concentrations in the solution and removal capacity of Cu(II) ion according to operation time were compared. The lower the initial concentration of Cu(II) ion in aqueous solution was, the removal capacity of Cu(II) ion by solid-phase extractant was increased relatively. The bigger the initial concentration of Cu(II) ion was, the removal capacity of Cu(II) ion was increased relatively. The pseudo-second-order kinetics according to operation time was showed more satisfying results than the pseudo-first-order kinetics for the removal velocity of Cu(II) ion. The removal capacity of Cu(II) ion was 0.025 mg/g in aqueous solution of pH 2, but the removal capacity of Cu(II) ion was increased to 0.33 mg/g mg/g in aqueous solution of pH 4 according to increasing pH.

Assessment of Quality Characteristics of the Shrimp Powder, Jook, for Elderly Foodservice Operation (노인급식에 적용하기 위한 새우 죽의 물리적, 관능적 품질특성 평가)

  • Cho, Hee-Sook;Kim, Kyung-Hee
    • Journal of the Korean Society of Food Culture
    • /
    • v.24 no.4
    • /
    • pp.419-425
    • /
    • 2009
  • This study examined the effects of added amounts of shrimp powder on the physical and sensory properties of Jook for elderly foodservice operation. According to the amylograph data, the composite shrimp flour-wheat flour samples increased the gelatinization temperature, with increasing shrimp-flour content; moreover, initial viscosity at $95^{\circ}C$, viscosity at $95^{\circ}C$ after 15 minutes, and maximum viscosity were reduced. As the level of shrimp powder in samples increased, L-values decreased, and a-values and b-values increased. In addition, the Jook had higher viscosity and lower spreadability values as the amount of shrimp powder increased. Sensory characteristics, such as nutty taste, color, viscosity, and overall preference increased significantly with the addition of shrimp powder. In conclusion, to enhance the quality of Jook, a 3% addition of shrimp powder would be the most beneficial.

Analysis on Current Limiting Characteristics of a Superconducting Fault Current Limiter (SFCL) with a Peak Currnt Limiting Function (피크전류제한 기능을 갖는 초전도한류기의 전류제한 특성분석)

  • Han, Tae-Hee;Lim, Sung-Hun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.1
    • /
    • pp.47-51
    • /
    • 2011
  • The superconducting fault current limiter (SFCL) with a peak current limiting function according to the initial fault current with the different amplitudes was suggested. The proposed SFCL, which consists of two limiting components, causes only the first superconducting element among two limiting components to be quenched in case that the initial fault current with the lower peak amplitude happens. On the other hand, the initial fault current with the higher peak amplitude makes both the superconducting elements of two limiting components to be quenched, which contributes to the peak current limiting function of the SFCL. To confirm the fault current limiting operation of the proposed SFCL, the short-circuit tests of the SFCL according to the fault angle were carried out and its effective fault current limiting operations could be discussed.

Indicator of Facility Performance Evaluation (FPE) for Educational Facilities of BTL Projects

  • Lee, Kwan-Jong;Lee, Chun-Kyong;Park, Tae-Keun
    • Architectural research
    • /
    • v.14 no.1
    • /
    • pp.35-44
    • /
    • 2012
  • Build-Transfer-Lease (BTL) was introduced to the domestic construction market in 2005. Now, seven years later, the BTL model is most active for educational facilities. In 2011, 93 educational facility projects entered the maintenance stage. Considering the characteristics of today's BTL projects for educational facilities, the main issues are the initial performance and maintenance of educational facilities and the service-providing status for the 20-year operational management period, in relation to providing safety and convenience to students, the facility users. Seeking a solution, local education offices and departments in charge of BTL under the Ministry of Education, Science, and Technology have been exploring various methods of evaluating operational maintenance performance from various perspectives. For educational facility BTL projects, however, the appropriateness of initial operation performance evaluation, rather than considering the 20-year operational management period, is controversial in regards to sustainability. On this account, performance evaluation items in four areas-operational maintenance evaluation, facility performance status evaluation, maintenance subject evaluation, and sustainable change response evaluation-should be extracted. An indicator of facility performance evaluation is presented in this study through an AHP survey targeting experts, as part of establishing an operation performance evaluation system for educational facility BTL projects.

The Cooling Characteristics for Circular Irradiation Hole under Suppressing Jet Flow at Guide Tube in HANARO (안내관 제트유동 억제시의 하나로 원형 조사공의 냉각특성)

  • Wu S. I.;Park P. C.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2004.03a
    • /
    • pp.208-213
    • /
    • 2004
  • The HANARO, multi-purpose research reactor, 30 MWth open-tank-in- pool type, is under normal operation since it reached the initial critical in February 1995. The HANARO is planning to produce a fission moly-99 of radio isotopes, a mother nuclide of Tc-99m, a medical isotope and is under developing a target handling tool for loading and unloading it in a circular flow tube (OR-5). A guide tube is extended from the reactor core to the top of the reactor chimney for easily un/loading a target under the reactor normal operation. But active coolant through the core can be quickly raised up to the top of the chimney through the guide tube by jet flow. This paper is described an analytical analysis to calculate the hole size of a orifice inserted in the circular irradiation hole and to study the flow characteristics through the guide tube under reactor normal operation and loading the target. As results, the results show that the hole size of orifice was 31 mm of the inner diameter to suppress the guide tube jet flow and the coolant safely cooled the target of fission moly after inserting the orifice to the flow tube.

  • PDF

200hrs Operational Characteristics of the Single Cell in Phosphoric Acid Fuel Cell (인산형 연료전지 단위전지 200시간 운전특성 연구)

  • Song, R.H.;Kim, C.S.;Choi, B.W.;Han, S.O.;Choi, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.73-77
    • /
    • 1991
  • 200hrs operational characteristics of the single cell in phosphoric acid fuel cell was studied. The initial performance of single cells was examined as a function of PTFE content of electrode in the range of 30 to 60 wt.%. The cell with the electrode of 40wt.% PTFE was chosen for the 200hrs operation. The cell voltage decay was found to be about 0.5mV/hr for 200hrs operation. These results of cell performance were discussed as related to the internal resistance and the exchange current density of the cell.

  • PDF