• 제목/요약/키워드: Initial flow

검색결과 1,838건 처리시간 0.028초

Frequency response of initially deflected nanotubes conveying fluid via a nonlinear NSGT model

  • Farajpour, Ali;Ghayesh, Mergen H.;Farokhi, Hamed
    • Structural Engineering and Mechanics
    • /
    • 제72권1호
    • /
    • pp.71-81
    • /
    • 2019
  • The objective of this paper is to develop a size-dependent nonlinear model of beams for fluid-conveying nanotubes with an initial deflection. The nonlinear frequency response of the nanotube is analysed via an Euler-Bernoulli model. Size influences on the behaviour of the nanosystem are described utilising the nonlocal strain gradient theory (NSGT). Relative motions at the inner wall of the nanotube is taken into consideration via Beskok-Karniadakis model. Formulating kinetic and elastic energies and then employing Hamilton's approach, the nonlinear motion equations are derived. Furthermore, Galerkin's approach is employed for discretisation, and then a continuation scheme is developed for obtaining numerical results. It is observed that an initial deflection significantly alters the frequency response of NSGT nanotubes conveying fluid. For small initial deflections, a hardening nonlinearity is found whereas a softening-hardening nonlinearity is observed for large initial deflections.

분포형 FLO-2D 수문모형에서 초기토양함수가 유출결과에 미치는 영향 (Impacts of Initial Soil Moisture on Hydrologic Outflow in a Distributed FLO-2D Model)

  • 이길하
    • 한국환경과학회지
    • /
    • 제30권8호
    • /
    • pp.613-619
    • /
    • 2021
  • Soil water enters the atmosphere via evapotranspiration, where it transforms into atmospheric water vapor and plays important role in the surface-atmosphere energy exchange. Soil conditions have a direct influence on the effective rainfall, and initial soil moisture conditions are important for quantitatively evaluating the effective rainfall in a watershed. To examine the sensitivity of the initial saturation to hydrologic outflow, a two-dimensional distributed FLO-2D hydrologic model was applied to a small watershed. The initial saturation was set to 0.3, 0.5, and 0.7 and the obtained results were compared. The Green-ampt model was chosen to calculate the penetration loss. Depending on the initial soil moisture, the peak flow rate varied by up to 60%, and the total water volume in the watershed by approximately 40%.

파-흐름의 공존장에서 실트질 점토의 정상특성 (Suspension Properties of Silty Mud in Combined Wave-Current Flow)

  • 김차겸;이종섭
    • 한국해안해양공학회지
    • /
    • 제4권1호
    • /
    • pp.26-33
    • /
    • 1992
  • 파-흐름의 공존장에서 실트질 점토의 부상특성을 연구하기 위해 조파수조에 흐름발생장치를 설치하며 파낭만 존재하는 경우, 순류 및 역류가 존재하는 경우에 대해서 장적물의 부상실험을 하였다. 역류가 작용할 때가 순류가 작용할 때보다 부상량이 훨씬 많았는데 이는 역류가 작용할 때는 저면에 난류성분이 발달하지만, 순류가 작용할 때는 진동류 효과가 감소하기 때문이다. 파-흐름의 공존장에서 실트질 점토의 부상양계저면전단응력은 $ au$$_{c}$~0.045 N/$m^2$인 것으로 추정되었다. 초기부상률과 저면전단응력과의 관계식 및 초기부상률과 측정된 유의파고와의 관계식이 도출되었는데, 초기부상률과 저면전단응력과의 관계는 상당히 분산되어 나타났으나, 초기부상률과 측정된 유의파고와의 관계는 상관성이 양호하게 나타났다. 파동하에서 장적물의 농도가 거의 평형상태에 도달했을 때에 농도의 연직경사로부터 산정된 장적물의 연직확산계수는 저면에서 수심의 1/2 지점까지는 지수형태로 증가하는 양상을 나타냈으나, 그 이상부터는 수심에 관계없이 거의 일정하게 나타났다.다.

  • PDF

증발하는 물방울의 계면활성제에 의한 열모세관 유동 억제 (Surfactant-Induced Suppression of the Thermocapillary Flow in Evaporating Water Droplets)

  • 윤성찬;김태권;임희창;강관형;임근배
    • 대한기계학회논문집B
    • /
    • 제37권7호
    • /
    • pp.695-701
    • /
    • 2013
  • 본 논문은 비이온의 계면 활성제에 의해 증발하는 물방울의 열모세관 유동(마랑고니 유동)이 억제되는 것을 실험적으로 검증한다. 물방울이 소수성 표면 위에서 증발할 때, 액적 내부의 마랑고니 유동을 관찰하였고, 계면 활성제 농도에 따라 이 유동이 억제되는 것을 조사하였다. 초기 계면 활성제 농도가 증가하면, 마랑고니 유동의 속도와 수명이 감소한다. 이 결과는 계면 활성제에 의해 액적 계면에서 점착 경계 조건이 성립됨을 보여주는데, 이것은 계면 점착 현상과 관련된 기존의 모델에 기초하여 설명되었다. 또한 액적의 초기 계면 활성제 농도가 임계 농도 이하일 때, 증발 초기 접촉선 비고정 현상을 발견했는데, 이것은 마랑고니 유동이 접촉각의 이력 현상을 감소시키기 때문이다.

관 출구로부터 방출되는 펄스파의 수치해석적 연구 (Computational Study of The Pulse Waves Discharged From The Open End of a Duct)

  • 김희동;김현섭;권용훈;이동훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.355-360
    • /
    • 2001
  • This study addresses a computational work of the impulsive wave which is discharged from the open end of a pipe. An initial compression wave inside the pipe is assumed to propagate toward atmosphere. The over pressure and wave-length of the initial compression wave are changed to investigate the characteristic values of the impulsive wave. The second order total variation diminishing (TVD) scheme is employed to solve the axisymmetric, compressible, unsteady Euler equations. The relationship between the initial compression wave form and impulsive wave is characterized in terms of the peak pressure of the impulsive wave and its directivity. The results obtained show that for the initial compression wave of a large wave-length the peak pressure of the impulsive wave does not depend on the over pressure of the initial compression wave, but for the initial compression wave of a very short wave-length, like a shock wave, the peak pressure of the impulsive wave is increased with an increase in the over pressure of the initial compression wave. The directivity of the impulsive wave to the pipe axis becomes significant with a decrease in the wave-length of the initial compression wave.

  • PDF

하나로 유동모의 설비의 유체순환계통 해석 (The Analysis of Flow Circulation System for HANARO Flow Simulated Test Facility)

  • 박용철
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.419-424
    • /
    • 2002
  • The HANARO, a multi-purpose research reactor of 30 MWth open-tank-in-pool type, has been under normal operation since its initial criticality In February, 1995. Many experiments should be safely performed to activate the utilization of the HANARO. A flow simulation facility is being developed for the endurance test of reactivity control units for extended life times and the verification of structural integrity of those experimental facilities prior to loading in the HANARO. This test facility is composed of three major parts; a half-core structure assembly, flow circulation system and support system. The flow circulation system is composed of a circulation pump, a core flow pipe, a core bypass flow pipe and instruments. The system is to be filled with de-mineralized water and the flow should be met the design flow to simulate similar flow characteristics in the core channel of the half-core test facility to the HANARO. This paper, therefore, describes an analytical analysis to study the flow behavior of the system. The computational flow analysis has been performed for the verification of system pressure variation through the three-dimensional analysis program with standard k-$\epsilon$ turbulence model and for the verification of the structural piping integrity through the finite element method. The results of the analysis are satisfied the design requirements and structural piping integrity of flow circulation system.

  • PDF

SMAC법에 의한 2차원 자유분류의 수치해석 (NUMERICAL ANALYSIS FOR 2-D FREE JET FLOW BY SMAC SCHEME)

  • 정세훈;안영준;신병록
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2009년 춘계학술대회논문집
    • /
    • pp.298-302
    • /
    • 2009
  • Numerical analysis of two dimensional incompressible laminar free jet flow was carried out by using finite difference SMAC scheme. Flow characteristics of free jet flow such as jet width, similarity of jet velocity and hypothetical origin were investigated for different Reynolds numbers of Re=30 and 100. The reliability of predictions were confirmed by comparison with exact solution. Non-dimensional velocity distribution showed similarity of jet flow velocity after initial region. In the region of laminar flow, the location of hypothetical origin becomes more distant with Reynolds number.

  • PDF

파워 스티어링용 베인 펌프 유량 제어부 설계에 관한 연구 (A Study on the Design of Flow Control Valve Attached to Vane Pump for Power Steering)

  • 이윤태
    • 한국생산제조학회지
    • /
    • 제9권5호
    • /
    • pp.87-95
    • /
    • 2000
  • The numerical analysis and the experiments are carried out to develop the design program for the flow control valve attached to the vane pump for power steering. The factors affecting the flow rate characteristics are analyzed by the experiments and the numerical analysis. The results are summarized as follows; (1) the main factors affecting to the first and second control flow rate are the diameter of big and small rod of the spool. (2) the cut off is mainly affected by the main spring constant, the initial displacement of main spring and the small diameter of the spool. (3) the dropping slope characteristics are decided by the chamfer of spool and the dynamic characteristics of the spool.

  • PDF

인공위성 추진기관 설계변수 도출을 위한 Hydrazine 액체 추진제의 비정상 유동해석 (Unsteady Flow Analysis of Liquid Hydrazine Propellant for the Design Parameter Derivation of Satellite Propulsion System)

  • 최진철;김정수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.497-501
    • /
    • 2000
  • One of the way to derive design parameters of the fuel feeding system in satellite is to analyze unsteady flow of liquid propellant (hydrazine) in the propulsion system. During steady thruster firing the flow rate is constant: if a thruster valve is abruptly shut down among a sets of thrusters, pressure spikes much higher than the initial tank pressure occur. This renders the fuel flow unsteady, and the fluid pressure and flow rate to oscillate. If the pressure spikes are high enough, there are possibilities that propellant explosively decomposes, thruster valves are damaged, and adiabatic detonation of the hydrazine propellant is potentially incurred. Reflected shockwaves could also affect the calibration and operation of the pressure transducers. These necessitate the analysis of unsteady flow in the propulsion system design, and the calculation results obtained through some governing parameter variation are presented in this work.

  • PDF

하나로 유동 모의 설비의 유체순환계통 해석 (The Analysis for Flow Circulation System in HANARO Flow Simulation Facility)

  • 박용철
    • 한국유체기계학회 논문집
    • /
    • 제7권1호
    • /
    • pp.30-35
    • /
    • 2004
  • The HANARO, a multi-purpose research reactor of 30 MWth open-tank-in-pool type, has been under normal operation since its initial criticality in February, 1995. Many experiments should be safely performed to activate the utilization of the HANARO. HANARO flow simulation facility is being developed for the endurance test of reactivity control units for extended life time and the verification of structural integrity of those experimental equipments prior to loading in the HANARO. This facility is composed of three major parts; a half-core structure assembly, a flow circulation system and a support system. The flow circulation system is composed of a circulation pump, a core flow piping, a core bypass flow piping and instruments. The system is to be filled with de-mineralized water and the flow should be met the design requirements to simulate a similar flow characteristics in the core channel of the half-core structure assembly to the HANARO. This paper, therefore, presents an analytical analysis to study the flow behavior of the system. Computational flow analysis has been performed for the verification of system pressure variation through the three-dimensional analysis program with the standard $k-{\epsilon}$ turbulence model and for the verification of the structural piping integrity through the finite element method. According to the analysis results, it could be said that the design requirements and the structural piping integrity of the flow circulation system are satisfied.