• Title/Summary/Keyword: Inhomogenous

Search Result 22, Processing Time 0.019 seconds

Immature Teratoma at Anterior Mediatinum - Report of one case - (종격동에 발생한 미성숙 기형종: 1례 보고)

  • 이재필
    • Journal of Chest Surgery
    • /
    • v.25 no.4
    • /
    • pp.435-437
    • /
    • 1992
  • We experienced one case of immature teratoma at anterior mediastinum. the patient was Syears old female whose complain were cough and chest pain. Chest film showed mass density St the lower half of the Rt chest. Chest CT showed inhomogenous mass which have some calcified area. At the time of operation, 12x10x13cm sized mass have smooth surface and its stump elongated to the thymus. a-FP level, preoperative 22.5ng/ml, was decreased to 9.7ng/ml after operation. Postoperative adjuvant chemotherapy was performed with Vinblastin, Bleomycin and Cisplatin combination. The patient had an uneventful postoperative or postchemotherapy course and was discharged in a good condition.

  • PDF

Self-Assembling Adhesive Bonding by Using Fusible Alloy Paste for Microelectronics Packaging

  • Yasuda, Kiyokazu
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.18 no.3
    • /
    • pp.53-57
    • /
    • 2011
  • In the modern packaging technologies highly condensed metal interconnects are typically formed by highcost processes. These methods inevitably require the precise controls of mutually dependant process parameters, which usually cause the difficulty of the change in the layout design for interconnects of chip to-chip, or chip-to-substrate. In order to overcome these problems, the unique concept and methodology of self-assembly even in micro-meter scale were developed. In this report we focus on the factors which influenced the self-formed bumps by analyzing the phenomenon experimentally. In case of RMA flux, homogenous pattern was obtained in both plain surface and cross-section surface observation. By using RA flux, the phenomena were accelerated although the self-formtion results was inhomogenous. With ussage of moderate RA flux, reaction rate of the self-formation was accelerated with homogeneous pattern.

The Value of High Resolution Ultrasonography in Diagnosis of Thyroid Nodule (갑상선 결절의 진단에 있어서 고해상능 초음파검사의 가치)

  • Shim Hyung-Jin;Choung Hue-Moon;Yoon Jung-Han;JeGal Young-Jong;Park Jin-Gyoon
    • Korean Journal of Head & Neck Oncology
    • /
    • v.6 no.2
    • /
    • pp.114-118
    • /
    • 1990
  • A clinical study of 37 cases with thyroid nodules, which were treated by surgical excision and confirmed pathologically at the Department of Surgery, Chonnam National University Medical School, from Dec. 1988 to Feb. 1990, was conducted and following results were obtained in ultrasonographic evaluation of thyroid nodules. 1) The thyroid adenoma were showed well-defined margin, homogenous internal echo and surrounding Halo, but thyroid cancer were showed ill-defined margin, inhomogenous internal echo and no surrounding Halo. 2) The sensitivity of high resoution ultrasonography compared with pathologic diagnosis to thyroid cancer was 87.5%, specificity 94.1%, accuracy 88%, false positive 5.88%, and negative 12.5%.

  • PDF

Spontaneous Rupture of Proximal Rectus Femoris: A case report (근위부 대퇴직근의 자연 파열 - 증례보고 -)

  • Jeon, In-Ho;Kyung, Hee-Soo;Lee, Sang-Won;Kim, Poong-Taek
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.5 no.1
    • /
    • pp.81-84
    • /
    • 2006
  • Rupture of the rectus femoris at the musculotendinous junction is very rarely reported in the literature, especially which is caused by chronic repetitive stimulation. A 21 year old soldier complained of progressing right thigh pain and mass for 8 weeks after military training. MRI of the right thigh showed inhomogenous mass lesion suspecting soft tissue tumor. However ultrasonographic examination showed torn retracted rectus femoris tendon at musculotendinous junction. One year after primary repair of ruptured tendon, the patient is free from symptoms and returned to full previous activities. Knowledge of this sonographic and MRI finding will help the surgeon to diagnose and treat this rare injury.

  • PDF

Mediastinal Cavernous Hemangioma Involving Whole SVC -A case report- (상대정맥 전장을 포함한 종격동 해면상 혈관종 - 1 례 보고 -)

  • Hur, Jin
    • Journal of Chest Surgery
    • /
    • v.35 no.8
    • /
    • pp.626-629
    • /
    • 2002
  • Cavernous hemangioma in mediastinum is a rare tumor. A 13 year old girl was referred becaused of abnormal mediastinal shadow in simple chest X-ray. Chest CT scan revealed a somewhat inhomogenous cystic legion arround the whole length of SVC. Surgical excision was done through the right posterolateral thorachotomy. The pathology was confirmed as cavernous hemangioma.

Stabilization of discrete-time semilinear heat processes by boundary inputs

  • Koay, S.P.;Sano, H.;Ito, K.;Kunimatsu, N.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10b
    • /
    • pp.1284-1288
    • /
    • 1990
  • In this paper, we are going to study the stabilization of the semilinear heat equation with inhomogenous boundary conditions, whose solutions are not (in general) stable. Here, we use the discrete-time feedback inputs through the boundary of geometric domain to the semilinear system under some additional conditions and assumptions. It is shown that under these conditions, the stabilization can be realized by applying pole assignment argument to the principal linear part of the system and that the solutions exist globally in discrete-time t without any finite escape time.

  • PDF

Kinetics of Recrystallization in Cold Rolled (냉간압연된 fcc 금속에서 재결정 속도에 관한 연구)

  • 조용상;허무영
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1996.10a
    • /
    • pp.150-156
    • /
    • 1996
  • The cold rolling of metal sheets leads to the formation of an inhomogeneous microstructure and texture. The type and sharpness of texture through the thickness and the degree of inhomogeneity depend on the friction between rolls the rolled material and the geometry of the rolling gap. In order to follow the effect of friction, two kinds of stecimens were prepared by applying with and without lubrication during the cold rolling. Although the deformed microstructure of the specimens rolled without lubrication was much inhomogenous than that of the specimens rolled with lubrication, the effect of lubrication on the cold rolling texture was not found. the recrystallization behavior was strongly dependent on the deformation process. Thus, the retardation of the recrystallization was observed in the specimens rolled without lubrication.

  • PDF

A Study on the characteristics of microstructure, hardness and wear of rapidly solidified AI-20Si-5Fe-2Ni materials (급냉응고 AI-20Si-5Fe-2Ni 합금의 조직, 경도 및 마모특성에 관한 연구)

  • 이상용;이정환;이영선;신평우
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1996.10a
    • /
    • pp.157-165
    • /
    • 1996
  • Characteristics of microstructure, hardness and wear of two AI-20Si-5Fe-2Ni materials produced by powder metallurgy and spray forming respectively were studied at temperatures up to 560$^{\circ}C$. Above 300$^{\circ}C$, the microstructure of powder processed alloy became inhomogenous, whereas the spray formed alloy showed homogeneous microstructures. Hardness of both alloys was increased between 300$^{\circ}C$~490$^{\circ}C$ in both alloy. It was interpreted that increase in hardness was mainly related to the formation of stable and fine intermetallic phase from metastable one. It was showed that hoogenity of microstructure in the rapidliy soldified affected directly wear property.

  • PDF

Synthesis and resistivity measurements of LK-99

  • Soo Min Park;L. Sun;T. Wu;Jongho Park;Changyong Kim;Jaeyong Kim
    • Progress in Superconductivity and Cryogenics
    • /
    • v.25 no.4
    • /
    • pp.1-4
    • /
    • 2023
  • Recently, a claim of material, named LK-99 (a lead apatite-based compound), exhibiting a superconducting transition temperature of over 400 K under standard atmospheric pressure, was reported [1, 2]. This claim has generated considerable attention from scientists worldwide. Here, we synthesized five LK-99 samples following the method detailed in the original papers [1, 2], and measured structural and resistivity data for each of these samples. The structure of the synthesized samples (P63/m, a=9.82 Å , c=7.34 Å ) was very close to the reported one. Contrary to the report, however, no hint of room-temperature superconductivity was noted from any of the samples. The results of Energy-dispersive X-ray spectroscopy (EDXS) measurements demonstrate that the atomic distribution in the sample was inhomogenous, and unreacted precursors were included in the samples. To investigate the intrinsic superconducting properties of LK-99, we propose to synthesize samples having high structural purity and chemical uniformity.

Determination of Incident Angle and Position of Optimal Mode Ultrasonic Beam for Flaw Detection in Anisotropic and Inhomogeneous Weldments by Ray Tracing

  • Zhao, Xinyu;Song, Sung-Jin;Kim, Hak-Joon;Gang, Tie;Kang, Suk-Chull;Choi, Yong-Hwan;Kim, Kyung-Cho;Kang, Sung-Sik
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.3
    • /
    • pp.231-238
    • /
    • 2007
  • Ultrasonic inspection of austenitic steel weldments is a truly difficult task due to complicated wave propagation phenomena such as beam skewing, splitting and distortion. In order to understand these phenomena and design proper inspection procedures, simulation is increasingly paid more attention to. This article addresses a ray tracing based approach to determine incident angle and position of optimal wave mode ultrasonic beam for flaw detection in anisotropic and inhomogeneous austenitic steel weldments. Specially, the optimal mode of ultrasonic wave wave is selected by ray tracing simulation, and an optimization approach based on ray tracing and bi-section search is proposed in order to find the ray path connecting two given points in weldments. With help of this approach, the optimal incident angle and position of ultrasonic beam can be determined for a given flaw position.