• 제목/요약/키워드: Inherent safety

검색결과 275건 처리시간 0.026초

Development of Micro Tensile Test of CVD-SiC coating Layer for TRISO Nuclear Fuel Particles at elevated temperature

  • Lee, Hyun-Min;Park, Kwi-Il;Kim, Do-Kyung
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 한국재료학회 2012년도 춘계학술발표대회
    • /
    • pp.95.1-95.1
    • /
    • 2012
  • Very High Temperature gas cooler Reactor (VHTR) has been considered as one of the most promising nuclear reactor because of many advantages including high inherent safety to avoid environmental pollution, high thermal efficiency and the role of secondary energy source. The TRISO coated fuel particles used in VHTR are composed of 4 layers as OPyC, SiC, IPyC and buffer PyC. The significance of CVD-SiC coatings used in tri-isotropic(TRISO) nuclear coated fuel particles is to maintain the strength of the whole particle. Various methods have been proposed to evaluate the mechanical properties of CVD-SiC film at room temperature. However, few works have been attempted to characterize properties of CVD-SiC film at high temperature. In this study, micro tensile system was newly developed for mechanical characterization of SiC thin film at elevated temperature. Two kinds of CVD-SiC films were prepared for micro tensile test. SiC-A had [111]-preferred orientation, while SiC-B had [220]-preferred orientation. The free silicon was co-deposited in SiC-B coating layer. The fracture strength of two different CVD-SiC films was characterized up to $1000^{\circ}C$.The strength of SiC-B film decreased with temperature. This result can be explained by free silicon, observed in SiC-B along the columnar boundaries by TEM. The presence of free silicon causes strength degradation. Also, larger Weibull-modulus was measured. The new method can be used for thin film material at high temperature.

  • PDF

Cytotoxicity of Ultra-pure TiO2 and ZnO Nanoparticles Generated by Laser Ablation

  • Jeong, Minju;Park, Jeong Min;Lee, Eun Jeong;Cho, Yea Seul;Lee, Chunghyun;Kim, Jeong Moo;Hah, Sang Soo
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권11호
    • /
    • pp.3301-3306
    • /
    • 2013
  • This paper aims to address the cellular toxicity of ultra-pure titanium dioxide ($TiO_2$) and zinc oxide (ZnO) nanoparticles (NPs) frequently employed in sunscreens as inorganic physical sun blockers to provide protection against adverse effects of ultraviolet (UV) radiation including UVB (290-320 nm) and UVA (320-400 nm). In consideration that the production and the use of inorganic NPs have aroused many concerns and controversies regarding their safety and toxicity and that microsized $TiO_2$ and ZnO have been increasingly replaced by $TiO_2$ and ZnO NPs (< 100 nm), it is very important to directly investigate a main problem related to the intrinsic/inherent toxicity of these NPs and/or their incompatibility with biological objects. In the present study, we took advantage of the laser-assisted method called laser ablation for generation of $TiO_2$ and ZnO NPs. NPs were prepared through a physical process of irradiating solid targets in liquid phase, enabling verification of the toxicity of ultra-pure NPs with nascent surfaces free from any contamination. Our results show that $TiO_2$ NPs are essentially non-poisonous and ZnO NPs are more toxic than $TiO_2$ NPs based on the cell viability assays.

Structural Restoration for the Electric Power Transmission Tower Damaged by Foundation Settlements (기초침하에 의해 손상된 송전철탑 구조물의 구조성능개선)

  • Lee, Ho Beom;Park, Jong Kwon;Kim, Il Soo;Jang, Il Young;Song, Jae Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • 제17권2호
    • /
    • pp.83-93
    • /
    • 2013
  • Generally the capacities of electric power transmission tower's members are improved by increasing their stiffness nature through injection of grout or attachment of other structural stiffeners. Those are for upgrading their axial strength by fulfillment of proper materials into pipe members, increment of member dimension by addition of section, or a combination of the two. However the use of innovative and unusual procedures would be positively recommended for getting more stable state. It is that buckled members are replaced with lengthened and strengthened members. In providing the structural restoration procedures for the existing electric power transform tower whose main members have been damaged due to unequal foundation settlement, structural damage inspection works and numerical analyses for the damaged one and the restored one were done in detail at first. secondarily member-exchanging works using a newly-generated jacking system and strengthened members were achieved. This figures are to point clearly to inherent advantages attending the management of the towers.

Performance Comparison of Space-Time Block Coding in High-speed Railway Channel (고속 철도 채널 환경에서 시공간 블록 부호 성능 비교)

  • Park, Seong-Guen;Lee, Jong-Woo;Jeon, Taehyun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • 제39C권3호
    • /
    • pp.291-297
    • /
    • 2014
  • Due to the rapid increase in demand for transportation of human and freight in modern railway systems, the CBTC system has been proposed, which is the solution for improvement of the line capacity that has been limited by the conventional track circuit based train control system. In the CBTC system, higher reliability of the communication system should be guaranteed for the safety of passengers and trains. However, due to the inherent characteristics of the wireless channel environment, performance degradations are inevitable. The diversity techniques can increase the reliability of data transmission using multiple antennas. In this paper, we investigate the performance of the STBC in the railway channel environment. Rician fading model is used for the viaduct scenarios which take important roles in the railway system. Also, considered is the Doppler effect which is an important factor in the mobile communication system. Simulations are performed to analyze the performance of the STBC in various channel environments. Results show that the performance degradation due to the phase error in viaduct scenarios is independent of the diversity order but is affected by the constellation of the modulation.

Reliability Based Design Optimization with Variation of Standard Deviation (표준편차의 변동을 고려한 신뢰성 최적설계)

  • Lim, O-Kaung;Kim, Hyung-Wook;Choi, Eun-Ho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • 제21권5호
    • /
    • pp.413-419
    • /
    • 2008
  • Deterministic design optimization (DO) does not explicitly deal with a variety of factors from inherent randomness and uncertainties. Reliability based design optimization(RBDO) is necessary to use in engineering systems in order to guarantee quality and performance of product. In this paper, design variables are considered as random variables. Standard deviation according to change of design variables have changed as much as coefficient of variation. And, if the standard deviation is error of manufacturing, standard deviation-mean relation is concave form. We obtain reliability index using advanced first order second moment method(AFOSM). This paper is examined by solving two examples and the results are compares with DO, RBDO and suggested RBDO.

Performance of steel beams at elevated temperatures under the effect of axial restraints

  • Liu, T.C.H.;Davies, J.M.
    • Steel and Composite Structures
    • /
    • 제1권4호
    • /
    • pp.427-440
    • /
    • 2001
  • The growing use of unprotected or partially protected steelwork in buildings has caused a lively debate regarding the safety of this form of construction. A good deal of recent research has indicated that steel members have a substantial inherent ability to resist fire so that additional fire protection can be either reduced or eliminated completely. A performance based philosophy also extends the study into the effect of structural continuity and the performance of the whole structural totality. As part of the structural system, thermal expansion during the heating phase or contraction during the cooling phase in most beams is likely to be restrained by adjacent parts of the whole system or sub-frame assembly due to compartmentation. This has not been properly addressed before. This paper describes an experimental programme in which unprotected steel beams were tested under load while it is restrained between two columns and additional horizontal restraints with particular concern on the effect of catenary action in the beams when subjected to large deflection at very high temperature. This paper also presents a three-dimensional mathematical modelling, based on the finite element method, of the series of fire tests on the part-frame. The complete analysis starts with an evaluation of temperature distribution in the structure at various time levels. It is followed by a detail 3-D finite element analysis on its structural response as a result of the changing temperature distribution. The principal part of the analysis makes use of an existing finite element package FEAST. The effect of columns being fire-protected and the beam being axially restrained has been modelled adequately in terms of their thermal and structural responses. The consequence of the beam being restrained is that the axial force in the restrained beam starts as a compression, which increases gradually up to a point when the material has deteriorated to such a level that the beam deflects excessively. The axial compression force drops rapidly and changes into a tension force leading to a catenary action, which slows down the beam deflection from running away. Design engineers will be benefited with the consideration of the catenary action.

Heavy metal adsorption of a novel membrane material derived from senescent leaves: Kinetics, equilibrium and thermodynamic studies

  • Zhang, Yu;Tang, Qiang;Chen, Su;Gu, Fan;Li, Zhenze
    • Membrane and Water Treatment
    • /
    • 제9권2호
    • /
    • pp.95-104
    • /
    • 2018
  • Copper pollution around the world has caused serious public health problems recently. The heavy metal adsorption on traditional membranes from wastewater is limited by material properties. Different adsorptive materials are embedded in the membrane matrix and act as the adsorbent for the heavy metal. The carbonized leaf powder has been proven as an effective adsorbent material in removing aqueous Cu(II) because of its relative high specific surface area and inherent beneficial groups such as amine, carboxyl and phosphate after carbonization process. Factors affecting the adsorption of Cu(II) include: adsorbent dosage, initial Cu(II) concentration, solution pH, temperature and duration. The kinetics data fit well with the pseudo-first order kinetics and the pseudo-second order kinetics model. The thermodynamic behavior reveals the endothermic and spontaneous nature of the adsorption. The adsorption isotherm curve fits Sips model well, and the adsorption capacity was determined at 61.77 mg/g. Based on D-R model, the adsorption was predominated by the form of physical adsorption under lower temperatures, while the increased temperature motivated the form of chemical adsorption such as ion-exchange reaction. According to the analysis towards the mechanism, the chemical adsorption process occurs mainly among amine, carbonate, phosphate and copper ions or other surface adsorption. This hypothesis is confirmed by FT-IR test and XRD spectra as well as the predicted parameters calculated based on D-R model.

Comparative analysis of internal flow characteristics of LBE-cooled fast reactor main coolant pump with different structures under reverse rotation accident conditions

  • Lu, Yonggang;Wang, Xiuli;Fu, Qiang;Zhao, Yuanyuan;Zhu, Rongsheng
    • Nuclear Engineering and Technology
    • /
    • 제53권7호
    • /
    • pp.2207-2220
    • /
    • 2021
  • Lead alloy is used as coolant in Lead-based cooled Fast Reactor (LFR). The natural characteristics of lead alloy are combined with the simple structural design of LFR. This constitutes the inherent safety characteristics of LFR. The main work of this paper is to take the main coolant pump (MCP) in the lead-cooled fast reactor (LFR) as the research object, and to study the flow pattern distribution of the internal flow field under the reverse rotation pump condition, the reverse rotation positive-flow braking condition and the reverse rotation negative-flow braking condition. In this paper, the double-outlet volute type and the space guide vane are selected as the potential designs of the CLEAR-I MCP. In this paper, the CFD method is used to study the potential reverse accident of the MCP. It is found that the highest flow velocity in the impeller appears at the impeller outlet, and the Q-H curves of the two design programs basically coincide. The space guide vane type MCP has better hydraulic performance under the reverse rotation positive-flow condition, the Q-H curves of the two designs gradually separate with increasing flow rate, and the maximum flow velocity inside the space guide vane type MCP is obviously lower than that of the double-outlet volute type. For the reverse rotation test of MCP, only the condition of the forward rotating pump of the main coolant pump is tested and verified. For the simulation of the MCP in LBE medium, it proved that the turbulence model and basic settings selected in the simulation are reliable.

Integrated cable vibration control system using Arduino

  • Jeong, Seunghoo;Lee, Junhwa;Cho, Soojin;Sim, Sung-Han
    • Smart Structures and Systems
    • /
    • 제23권6호
    • /
    • pp.695-702
    • /
    • 2019
  • The number of cable-stayed bridges has been increasing worldwide, causing issues in maintaining the structural safety and integrity of bridges. The stay cable, one of the most critical members in cable-stayed bridges, is vulnerable to wind-induced vibrations owing to its inherent low damping capacity. Thus, vibration mitigation of stay cables has been an important issue both in academia and practice. While a semi-active control scheme shows effective vibration reduction compared to a passive control scheme, real-world applications are quite limited because it requires complicated equipment, including for data acquisition, and power supply. This study aims to develop an Arduino-based integrated cable vibration control system implementing a semi-active control algorithm. The integrated control system is built on the low-cost, low-power Arduino platform, embedding a semi-active control algorithm. A MEMS accelerometer is installed in the platform to conduct a state feedback for the semi-active control. The Linear Quadratic Gaussian control is applied to estimate a cable state and obtain a control gain, and the clipped optimal algorithm is implemented to control the damping device. This study selects the magnetorheological damper as a semi-active damping device, controlled by the proposed control system. The developed integrated system is applied to a laboratory size cable with a series of experimental studies for identifying the effect of the system on cable vibration reduction. The semi-active control embedded in the integrated system is compared with free and passive mode cases and is shown to reduce the vibration of stay-cables effectively.

A Study on the Recognition of Fire-fighters on Korean Civil Anti-Disaster Organization for Public Safety (국민안전을 위한 민간 방재조직에 대한 소방관들의 인식 연구)

  • Chae, Jong-Sik;Lee, Si-Young
    • Journal of Korea Entertainment Industry Association
    • /
    • 제15권2호
    • /
    • pp.137-148
    • /
    • 2021
  • This study sought for an improvement plan of the overall preventive activity of Korean Citizen-Corps-Active-In-Disaster(CAIND) by utilizing the fact that The fire-fighters, who are focusing on social disaster response works, are surveyed for their awareness of the vivid expertise to Korean CAIND. This group is defined as the assistant organization in law about disaster prevention which, the local residents willingly made to handle the situation of disaster occurrence. Since the characteristics of volunteer activities are also inherent, related issues are also reviewed at the same time to resolve any unclear arguments by disaster prevention activity characteristics of Korean Citizen Corps Active in Disaster. Through the results, the study provided three major suggestions for an improvement plan. The results of the study are as follows: First, the quota management system of Korean CAIND that considers the characteristics of rural areas should be actively supplemented. Second, the current reward system for Korean CAIND activities at large disaster sites should be surely improved. Third, the current education and training system of Korean CAIND to satisfy regional conditions should be newly established. The results of this study are largely expected to be utilized as a basic data to develop Korean CAIND in the future.