• Title/Summary/Keyword: Infrared transmittance

Search Result 166, Processing Time 0.026 seconds

EVALUATION OF NON-INVASIVE BLOOD GLUCOSE MEASUREMENT USING THREE TYPES OF NEAR INFRARED SPECTROMETER

  • Baek, Ju-Hyun;Kang, Na-Roo;Woo, Young-Ah;Kim, Hyo-Jin
    • Proceedings of the PSK Conference
    • /
    • 2003.04a
    • /
    • pp.289.1-289.1
    • /
    • 2003
  • Three types of near infrared spectrometer, a photo diode array type, a dispersive type and a FT type, were evaluated and compared the systematic difference in blood glucose measurement. The fundamental study was performed by adding glucose to buffer solution and bovine blood as the preceding study of non-invasive blood glucose. Spectra were collected using a 1.0 mm optical pathlength quartz cell by transmittance method. (omitted)

  • PDF

Optimal Parameter Selection of Near-Infrared Optics Based Design of Experiment for Silicon Wafer in Solar Cell (태양전지 실리콘 웨이퍼를 위한 실험계획법 기반 근적외선 광학계의 최적조건 선정)

  • Seo, Hyoung Jun;Kim, Gyung Bum
    • Journal of the Semiconductor & Display Technology
    • /
    • v.12 no.3
    • /
    • pp.29-34
    • /
    • 2013
  • Solar cell has been considered as renewable green energy. Its silicon wafer thickness is thinner due to manufacturing cost and accordingly micro cracks is often generated in the process. Micro cracks result in bad quality of solar cell, and so their accurate and reliable detection is required. In this paper, near-infrared optics system is newly designed based on the analysis of near-infrared transmittance characteristics and its important parameters are optimally selected using the design of experiment for micro crack detection in solar cell wafer. The performance of the proposed method is verified using several experiments.

Quantitative Analysis of Indomethacin by the Portable Near-Infrared (NIR) System (근적외분광분석법을 이용한 인도메타신의 정량분석)

  • 김도형;우영아;김효진
    • YAKHAK HOEJI
    • /
    • v.47 no.5
    • /
    • pp.261-265
    • /
    • 2003
  • Near-infrared (NIR) system was used to determine rapidly and simply indomethacin in buffer solution for a dissolution test of tablets and capsules. Indomethacin standards were prepared ranging from 10 to 50 ppm using the mixture of phosphate buffer (pH 7.2) and water (1 : 4). The near-infrared (NIR) transmittance spectra of indomethacin standard solutions were collected by using a quartz cell in 1 mm and 2 mm pathlength. Partial least square regression (PLSR) was explored to develop calibration models over the spectral range 1100∼1700 nm. The model using 1 mm quartz cell was better than that using 2 mm quartz cell. The PLSR models developed gave standard error of prediction (SEP) of 0.858 ppm. In order to validate the developed calibration model, routine analysis was performed using another standard solutions. The NIR routine analysis showed good correlation with actual values. Standard error of prediction (SEP) is 1.414 ppm for 7 indomethacin samples in routine analysis and its error was permeable in the regulation of Korean Pharmacopoeia (VII). These results show the potential use of the real time monitoring for indomethacin during a dissolution test.

Extraordinary Optical Transmission and Enhanced Magneto-optical Faraday Effect in the Cascaded Double-fishnet Structure with Periodic Rectangular Apertures

  • Lei, Chengxin;Man, Zhongsheng;Tang, Shaolong
    • Current Optics and Photonics
    • /
    • v.4 no.2
    • /
    • pp.134-140
    • /
    • 2020
  • A significant enhancement of the magneto-optical Faraday rotation and extraordinary optical transmission (EOT) in the cascaded double-fishnet (CDF) structure with periodic rectangular apertures is theoretically predicted by using the extended finite difference time domain (FDTD) method. The results demonstrate that the transmittance spectrum of the CDF structure has two EOT resonant peaks in a broad spectrum spanning visible to near-infrared wavebands, one of them coinciding with the enhanced Faraday rotation and large figure of merit (FOM) at the same wavelength. It is most important that the resonant position and intensity of the transmittance, Faraday rotation and FOM can be simply tailored by adjusting the incident wavelength, the thickness of the magnetic layer, and the offset between two metallic rectangular apertures, etc. Furthermore, the intrinsic physical mechanism of the resonance characteristics of the transmittance and Faraday rotation is thoroughly studied by investigating the electromagnetic field distributions at the location of resonance. It is shown that the transmittance resonance is mainly determined by different hybrid modes of surface plasmons (SPs) and plasmonic electromagnetically induced transparency (EIT) behavior, and the enhancement of Faraday rotation is mostly governed by the plasmonic electromagnetically induced absorption (EIA) behavior and the conversion of the transverse magnetic (TM) mode and transverse electric (TE) mode in the magnetic dielectric layer.

An Optical Characteristic Research of a Netspec Lens (네츠팩 렌즈의 광학적 특성 연구)

  • Lee, Dong-Hee;Kim, Dae-Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.1
    • /
    • pp.85-90
    • /
    • 2003
  • A Netspec lens has the form having the 2-dimensional mesh coating on a general ophthalmic lens. It is known that it makes the ophthalmic image see more clearly, reducing the ophthalmic fatigue and that the transmittance of it for ultraviolet and infrared rays is lower. We need to prove this characteristic scientifically. So, in this study, we applied the Kirchhoff's scalar wave theory to the Netspec lens and induced a transmittance expression. And we made the program of which simulation can explain the transmittance effect of the Netspec lens. Also, we tried the interpreting about the result of the simulation. Finally, we have known that this simulation program can be used to adjust the transmittance of the light according to the wavelength.

  • PDF

The Study on Optical Properties by Adding La$_2$O$_3$ in Multicomponent Glass Fiber (다성분계 Glass Fiber의 La$_2$O$_3$첨가에 따른 광학적 특성에 관한 연구)

  • 김용호;강원호
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1985.01a
    • /
    • pp.21-23
    • /
    • 1985
  • By adding La$_2$O$_3$ to optical multicomponent glass composition, after making mother glass and core fiber that enable to enlarge the infrared transmittance region, then surveyed the optical properties. Through thermal analysis of the glass abstained by melt-quenching after selecting stable basic composition on devitrification and replace SiO$_2$ by 4-12wt% La$_2$O$_3$. As La$_2$O$_3$ increases up to l2wt% transition temperature, refractive index, density, deformation temperature increased, whereas thermal expansion coefficient decreased. As a result of inspectig transmittance in UV/VIS/IR region, visable region indicated the decrease of transmittance by increasing the La$_2$O$_3$ and transmittance region was enlarged by increasing the La$_2$O$_3$ in IR region. Also, fabricate core fiber at 820$^{\circ}C$ and severy the optical loss we could fact that La$_2$O$_3$ composition added 12wt% showed the minimum optical loss.

A Study on the Optical Transmittance of High-energy Electron-beam Irradiated IGZO Thin Films (고 에너지 전자빔 조사된 IGZO 박막의 광 투과도에 대한 연구)

  • Yun, Eui-Jung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.6
    • /
    • pp.71-77
    • /
    • 2014
  • In this paper, we investigated the effects of high-energy electron beam irradiation (HEEBI) on the optical transmittance of InGaZnO (IGZO) films grown on transparent Corning glass substrates, with a radio frequency magnetron sputtering technique. The IGZO thin films deposited at low temperature were treated with HEEBI in air at room temperature (RT) with an electron beam energy of 0.8 MeV and doses of $1{\times}10^{14}-1{\times}10^{16}electrons/cm^2$. The optical transmittance of the IGZO films was measured using an ultraviolet visible near-infrared spectrophotometer (UVVIS). The detailed estimation process for separating the transmittance of HEEBI-treated IGZO films from the total transmittance of IGZO films on transparent substrates treated with HEEBI is given in this paper. Based on the experimental results, we concluded that HEEBI with an appropriate dose of $10^{14}electrons/cm^2$ causes a maximum increase in the transparency of IGZO thin films. We also concluded that HEEBI treatment with an appropriate dose shifted the optical band gap ($E_g$) toward the lower energy region from 3.38 to 3.31 eV. This $E_g$ shift suggested that HEEBI in air at RT with an appropriate dose acts like a thermal annealing treatment in vacuum at high temperature.

Thermal Radiative Properties of Multilayer Graphene/Glass Structure (다층 그래핀/유리 구조체의 적외선 열복사 특성 연구)

  • Park, Kyung-Ah;Lim, Mikyung;Jung, Hyun-June;Kim, Jae-Hyun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.34 no.1
    • /
    • pp.27-32
    • /
    • 2021
  • In this study, we fabricated multilayer graphene on a glass substrate by stacking the monolayer graphene synthesized via chemical vapor deposition. The electrical sheet resistance and optical transmittance were evaluated to confirm the quality of the stacked multilayer graphene. Using the fabricated multilayer graphene/glass structure, we characterized its thermal radiative property in terms of the integrated emissivity. The integrated emissivity of the multilayer graphene/glass structure was tuned from 0.91 to 0.72 when the number of graphene layers was changed from 1 to 12. We also demonstrated that the emissivity tunability provided a way to control the apparent temperature of an object that can be used in infrared stealth applications.

PREDICTION OF PHYSICO-CHEMICAL AND TEXTURE CHARACTERISTICS OF BEEF BY NEAR INFRARED TRANSMITTANCE SPECTROSCOPY

  • Olivan, Mamen;Delaroza, Begona;Mocha, Mercedes;Martinez, Maria Jesus
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1256-1256
    • /
    • 2001
  • The physico-chemical and texture characteristics of meat determine the nutritional, technological and sensory quality. However, the analysis of meat quality requires expensive, laborious and time consuming analytical methods. The objective of this study was to evaluate NIR spectroscopy using transmittance for determining the moisture, fat, protein and total pigment content, the water holding capacity (WHC) and the toughness of beef meat. A total of 318 spectra were recorded from ground beef samples by a Feed Analyzer 1265 of Infratec. The samples were obtained from the Longissimus muscle of the 10$^{th}$ rib of yearling bulls, ground with an electrical chopper, vacuum packaged, aged during 7 days and frozen at -24$^{\circ}C$ until the analyses were done. Moisture content was measured by oven drying at 10$0^{\circ}C$, fat content was determined by Soxhlet extraction and protein content was estimated from nitrogen content using the Kjeldahl analysis. The total pigment content was determined by the method of Hornsey and the WHC using the method of filter paper press. The instrumental evaluation of texture (maximum load WB, maximum stress MS and toughness) was conducted in an Instron equipment with a Warner-Bratzler shearing device. This analysis was performed on a chop of 3.5 cm obtained from the longissimus of the 8$^{th}$ rib, aged during 7 days, kept frozen at -24$^{\circ}C$ and cooked before the analysis. Near infrared spectra were recorded as log 1/T (T=transmittance) at 2 nm intervals from 850 to 1050 nm using a Feed Analyzer 1265 of Infratec. Calibrations were performed with the WinISI software (vs. 1.02) using the MPLS method. To examine the effect of scatter correction o. derivation of spectra on the calibration performance, calibrations were calculated with the crude spectra or pretreated with different mathematical treatments (inverse MSC, SNVD) and/or second derivative operation. For chemical composition, the use of the scatter corrections improved the calibration statistics, in terms of lower SECV and higher $r^2$. In most of the variables, the use of the 2$^{nd}$ derivative improved the predictions, mainly when combined with the SNVD treatment. However, for predicting the texture traits, the best estimation was obtained from the crude spectrum. These results showed that the equations obtained for predicting moisture, fat and total pigments were very accurate, with $r^2$ being higher that 0.9. However, the prediction of the texture traits (WB, MS, toughness) from ground meat was poor.

  • PDF

Dissolution Test for Indomethacin by the Portable Near-Infrared(NIR) System

  • Kim, Do-Hyung;Lim, Hun-Rang;Chang, Soo-Hyun;Woo, Young-Ah;Kim, Hyo-Jin
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.399.3-399.3
    • /
    • 2002
  • Near-infrared (NIR) system was used to determine rapidly and simply indomethacin in buffer solution for a dissolution test for tablets and capsules. Indomethacin standards were prepared ranging from 10 to 50ppm using mixture of phosphate buffer(pH 7,2) and water(1:4), The near infrared(NIR) transmittance spectra of indomethacin standard solutions were collected by using a quartz cell in 1 mm and 2mm pathlength, Partial least-square regression (PLSR) was explored to develop calibration models over the spectral range 1100-1700nm. (omitted)

  • PDF