• Title/Summary/Keyword: Infrared thermal imaging system

Search Result 109, Processing Time 0.032 seconds

Measurement of temperature profile using the infrared thermal camera in turbulent stratified liquid flow for estimation of condensation heat transfer coefficients

  • Choi, Sung-Won;No, Hee-Cheon
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1999.05a
    • /
    • pp.107-107
    • /
    • 1999
  • Direct-contact condensation experiments of atmospheric steam and steam/air mixture on subcooled water flowing co-currently in a rectangular channel are carried out uszng an infrared thermal camera system to develop a temperature measurement method. The inframetrics Model 760 Infrared Thermal Imaging Radiometer is used for the measurement of the temperature field of the water film for various flow conditions. The local heat transfer coefficient is calculated using the bulk temperature gradient along the (low direction. It is also found that the temperature profiles can be used to understand the interfacial condensation heat transfer characteristics according to the flow conditions such as noncondensable gas effects, inclination effect, and flow rates.

  • PDF

Design of Imaging Optical System with 24mm Focal length for MWIR (MWIR용 24mm 초점거리를 가지는 결상광학계의 설계)

  • Lee, Sang-Kil;Lee, Dong-Hee
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.6
    • /
    • pp.203-207
    • /
    • 2018
  • This paper deals with the design and development of a lens system capable of imaging an infrared image of $3{\sim}5{\mu}m$ wavelength bands with a focal length of 24mm and good atmospheric transmission characteristics. The design used CodeV, a commercial design program, and the optimization is carried out with weighting to eliminate chromatic aberration, spherical aberration and distortion. The designed lens system consists of two lenses consisting of Si and Ge. Each lens has an aspherical surface on one side. And this optical system has the resolution of the characteristics that the MTF value is 0.40 at the line width of 29lp/mm and the MTF value is 0.25 at the line width of 20lp/mm. This optical system is considered to have the capability to be applied to the thermal imaging camera for MWIR using the $206{\times}156$ array infrared detector of $25{\mu}m$ pixels and the $320{\times}240$ array infrared detector of $17{\mu}m$ pixels.

Real Time Image Processing of Thermal Imaging System (열상장비의 실시간 영상 신호처리)

  • Hong Seok Min;Yu Wee Kyung;Yoon Eun Suk
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.7 no.4 s.19
    • /
    • pp.79-86
    • /
    • 2004
  • This paper has presented to the design results of the analog and digital signal processor for the 2nd generation thermal imaging system using $480\times6$ infrared focal plane array In order to correct non-uniformities of detector arrays, we have developed the 2-point correction method using the thermo electric cooler. Additionally, to enhance the image of low contrast and improve the detection capability, we developed the new technique of histogram processing being suitable for the characteristics of contrast distribution of thermal imagery. Through these image processing techniques, we obtained a high qualify thermal image and acquired good result.

The Construction of Quality Inspection System for Sunroof Sealer Application Process Using SVM Algorithm (SVM 알고리즘을 활용한 선루프 실러도포 공정 품질검사 시스템 구축)

  • Yang, Hee-Jong;Jang, Gil-Sang
    • Journal of the Korea Safety Management & Science
    • /
    • v.23 no.3
    • /
    • pp.83-88
    • /
    • 2021
  • Recently, due to the aging of workers and the weakening of the labor base in the automobile industry, research on quality inspection methods through ICT(Information and Communication Technology) convergence is being actively conducted. A lot of research has already been done on the development of an automated system for quality inspection in the manufacturing process using image processing. However, there is a limit to detecting defects occurring in the automotive sunroof sealer application process, which is the subject of this study, only by image processing using a general camera. To solve this problem, this paper proposes a system construction method that collects image information using a infrared thermal imaging camera for the sunroof sealer application process and detects possible product defects based on the SVM(Support Vector Machine) algorithm. The proposed system construction method was actually tested and applied to auto parts makers equipped with the sunroof sealer application process, and as a result, the superiority, reliability, and field applicability of the proposed method were proven.

Soundness Evaluation of 120W LED Lighting using Passive Infrared Thermal Imaging Method (수동적 적외선 열화상 기법을 적용한 120W급 LED조명등 건전성 평가)

  • Jung, Yoon-Soo;Gao, Jia-Chen;Kim, Jae-Yeol
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.4
    • /
    • pp.140-146
    • /
    • 2017
  • As energy conservation and environmental issues are emerging as a hot topic around the world, consumers are demanding high-efficiency, eco-friendly products. In this study, the author proposed 120W LED lighting system that replace metal halide lamp (MHL) which is currently used in the industry. Furthermore, it would be possible to provide a perfect opportunity for Korea to rise as a global leader in the LED lighting industry through soundness evaluation of the LED lighting system that is applied.

High Resolution Electronic Processor Design for Thermal Imager with 320x240 Staring Array Infrared Detector (320x240 적외선 배열검출기를 이용한 고분해능 열상 신호처리기 구현)

  • Hong, Seok-Min;Yu, Wee-Kyung;Yoon, Eun-Suk
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.9 no.2 s.25
    • /
    • pp.111-117
    • /
    • 2006
  • This paper describes the design principles and methods of electronic processor for thermal imager with 320$\times$240 staring array infrared detector. For the detector's nonuniformity correction and excellent image quality, we have designed the multi-point correction method using the defocusing technique of the optics. And to enhance the image of low contrast and improve the detection capability, the new technique of histogram processing has been designed. Through these image processing techniques, we have developed the high quality thermal imager and acquired a satisfactory thermal image. The result of MRTD(Minimum Resolvable Temperature Difference) is $0.1^{\circ}C$ at 4cycles/mard.

Thermal Analysis of MIRIS Space Observation Camera for Verification of Passive Cooling

  • Lee, Duk-Hang;Han, Won-Yong;Moon, Bong-Kon;Park, Young-Sik;Jeong, Woong-Seob;Park, Kwi-Jong;Lee, Dae-Hee;Pyo, Jeong-Hyun;Kim, Il-Joong;Kim, Min-Gyu;Matsumoto, Toshio
    • Journal of Astronomy and Space Sciences
    • /
    • v.29 no.3
    • /
    • pp.305-313
    • /
    • 2012
  • We conducted thermal analyses and cooling tests of the space observation camera (SOC) of the multi-purpose infrared imaging system (MIRIS) to verify passive cooling. The thermal analyses were conducted with NX 7.0 TMG for two cases of attitude of the MIRIS: for the worst hot case and normal case. Through the thermal analyses of the flight model, it was found that even in the worst case the telescope could be cooled to less than $206^{\circ}K$. This is similar to the results of the passive cooling test (${\sim}200.2^{\circ}K$). For the normal attitude case of the analysis, on the other hand, the SOC telescope was cooled to about $160^{\circ}K$ in 10 days. Based on the results of these analyses and the test, it was determined that the telescope of the MIRIS SOC could be successfully cooled to below $200^{\circ}K$ with passive cooling. The SOC is, therefore, expected to have optimal performance under cooled conditions in orbit.

Development of the Near Infrared Camera System for Astronomical Application

  • Moon, Bong-Kon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.39.2-39.2
    • /
    • 2010
  • In this paper, I present the domestic development of near infrared camera systems for the ground telescope and the space satellite. These systems are the first infrared instruments made for astronomical observation in Korea. KASINICS (KASI Near Infrared Camera System) was developed to be installed on the 1.8m telescope of the Bohyunsan Optical Astronomy Observatory (BOAO) in Korea. KASINICS is equipped with a $512{\times}512$ InSb array enable L band observations as well as J, H, and Ks bands. The field-of-view of the array is $3.3'{\times}3.3'$ with a resolution of 0.39"/pixel. It employs an Offner relay optical system providing a cold stop to eliminate thermal background emission from the telescope structures. From the test observation, limiting magnitudes are J=17.6, H=17.5, Ks=16.1 and L(narrow)=10.0 mag at a signal-to-noise ratio of 10 in an integration time of 100 s. MIRIS (Multi-purpose InfraRed Imaging System) is the main payload of the STSAT-3 in Korea. MIRIS Space Observation Camera (SOC) covers the observation wavelength from $0.9{\mu}m$ to $2.0{\mu}m$ with a wide field of view $3.67^{\circ}{\times}3.67^{\circ}$. The PICNIC HgCdTe detector in a cold box is cooled down below 100K by a micro Stirling cooler of which cooling capacity is 220mW at 77K. MIRIS SOC adopts passive cooling technique to chill the telescope below 200K by pointing to the deep space (3K). The cooling mechanism employs a radiator, a Winston cone baffle, a thermal shield, MLI of 30 layers, and GFRP pipe support in the system. Opto-mechanical analysis was made in order to estimate and compensate possible stresses from the thermal contraction of mounting parts at cryogenic temperatures. Finite Element Analysis (FEA) of mechanical structure was also conducted to ensure safety and stability in launching environments and in orbit. MIRIS SOC will mainly perform the Galactic plane survey with narrow band filters (Pa $\alpha$ and Pa $\alpha$ continuum) and CIB (Cosmic Infrared Background) observation with wide band filters (I and H) driven by a cryogenic stepping motor.

  • PDF

A Study on Feasibility Analysis and Alternatives for Infrared Detector Development (적외선 검출기 개발가능성 및 대안 분석 연구)

  • Kim, Gyeong-Su;Min, Seong-Gi;Kim, Cheol-Hwan
    • 시스템엔지니어링워크숍
    • /
    • s.4
    • /
    • pp.123-134
    • /
    • 2004
  • This paper deals with the feasibility analysis and alternatives for infrared detector development. The purpose of this paper analyze development requirement and feasibility study in both technology and cost. We get raw input data for system engineering process from development and technical expert, and then analyze cost and technology for development feasibility, and alternative study. Infrared Detector is core component of Thermal Imaging System and developed by ADD from 2006 to 2008 year. Technical level is analyzed by TRL(Technical Readiness Level) and AOA(Analysis of Alternative) is done by development and production cost estimate. We use SEER-H tool for cost estimate, that is parametric cost estimate tool based on Knowledge Base. Also this paper presents risk analysis for project management because it is necessary to risk driver management during the infrared detector development. The result of IR Detector feasibility and alternative study will be used in technical and cost analysis. This study can help those who are related to the cost analysis and development feasibility of other weapons

  • PDF

The Changes of Skin Temperature and Subjective Fatigue of the Thoracic Vertebrae by the Chiropractic Adjustments (흉추에 적용한 척추교정이 피부온도와 주관적 피로에 미치는 영향)

  • Yoon, Jung-Gyu;Lee, Geon-Cheol
    • Journal of Korean Physical Therapy Science
    • /
    • v.10 no.1
    • /
    • pp.102-108
    • /
    • 2003
  • The purpose of this study was to determine the changes of skin temperature and subjective fatigue of the thoracic vertebrae by the chiropractic adjustments. Stimulation of the sympathetic nervous system will cause the changes in the skin blood flow which can be detected by measuring the skin surface temperature. This study was to see whether chiropractic adjustments could affect the activity of the sympathetic nervous system as reflected by changes in skin temperature of the thoracic. Skin temperature and subjective fatigue on 16 subjects was measured before, within 10 sec, 10min, 20min and 30 min after a thoracic adjustment with Digital Infrared Thermal Imaging(DITI) and Visual Analogue Scale(VAS). The adjustments consisted of a straight posterior-to-anterior high-speed, low-amplitude thrust to the transverse process of T3-T10 using a reinforced hypothenar contact. The average temperature and fatigue changed when the spine was considered as an entire unit. These results illustrate that the blood flow through the soft tissue can be affected by specific adjustments to the spine. This study might be served as an useful baseline data for the changes of the circulation and fatigue after the chiropractic adjustments.

  • PDF