• Title/Summary/Keyword: Infrared thermal camera

Search Result 230, Processing Time 0.031 seconds

Analysis of Visible Light Communication Module Degraded by High Dose-Rate Gamma Irradiation using Thermal Infrared Image (적외선 열영상을 이용한 가시광 통신모듈의 고선량 감마선조사에 따른 열화 분석)

  • Cho, Jai-Wan;Hong, Seok-Boong;Koo, In-Soo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.12
    • /
    • pp.1203-1209
    • /
    • 2011
  • In this paper, the degradation evaluation method of VLC (Visible Light Communication) wireless module after high dose rate gamma-ray irradiation using the thermal infrared camera is proposed. First, the heating characteristics of the active devices embedded in the VLC wireless module during the condition of normal operation is monitored by thermal infrared camera. By the image processing technique, the trends of the intensity of the heat emitted by the active devices are calculated and stored. The feature of the blob area including the area of the active devices in the thermal infrared image is extracted and stored. The feature used in this paper is the mean value of the gray levels in the blob area. The same VLC module has been gamma irradiated at the dose rate of about 4.0 kGy/h during 72 hours up to a total dose of 288 kGy. And then, the heating characteristics of the active devices embedded in the VLC wireless module after high dose gamma ray irradiation is observed by thermal infrared camera. The high dose gamma-ray induced degradation of the active devices embedded in the VLC module was evaluated by comparing the mean value of the blob area to the one of the same blob area of the VLC module before the gamma ray irradiation.

Development of IR Thermal Camera Detector based on Smartphone Interlocking for Hidden Camera Crime Prevention (몰래카메라 범죄방지를 위한 스마트폰 연동 기반의 IR 열카메라 탐지기 개발)

  • Kang, Young-Gil;Cho, Pil-Gu;Kim, Young-Gon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.21 no.6
    • /
    • pp.1-8
    • /
    • 2021
  • The performance of hidden camera cameras is improving day by day due to miniaturization and advanced technology integration according to the speed of technological development of smartphones. As this external networking computing environment is advanced and diversified, exposure to hidden cameras in addition to general safety cameras is also increasing. On the other hand, the technology for detecting and preventing hidden cameras is not keeping up with the development and speed of these hidden cameras. Therefore, in this study, the heat of the hidden camera was detected using infrared thermal detection technology based on general image and thermal image synthesis technology, and the reflectance of each wavelength according to the difference in ambient temperature was analyzed to reduce the false positive rate.

A STUDY OF THERMAL ANALYSIS OF KAONICS (적외선 카메라 KAONICS의 열해석)

  • Kang, Ji-Na;Lee, Sung-Ho;Jin, Ho;Park, Soo-Jong;Moon, Bong-Kon;Kim, Sang-Ho;Park, Jang-Hyun
    • Journal of Astronomy and Space Sciences
    • /
    • v.21 no.4
    • /
    • pp.467-480
    • /
    • 2004
  • It is very important to eliminate thermal background radiation for the near infrared camera system such as KAONICS (KAO Near Infrared Camera System). Thermal background radiations which come from window and cryostat wall influence IR detector and decrease IR system performance. Therefore the cold box which contains optics and detector housing must be cooled down to eliminate thermal background radiation. We carried out quantitative analysis to determine internal cooling temperature to reduce thermal noise in the J, H, Ks, and L bandpass. Additionally, we estimated the incoming heat load and then chose the cryocooler adequate to KAONICS's requirements. The cooling time and the final cooling temperature of the cold box were calculated. These results were also implemented to the system design.

The design methods of Infrared Camera with Continuous zoom

  • Son, Seok-Hyeon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.12
    • /
    • pp.19-26
    • /
    • 2016
  • In this paper, we propose an efficient design method for a thermal camera with continuous zoom based on the research and manufacturing experience of the thermal camera. In addition, it is divided into system design method, optical design method, mechanical design method, and electronic design method. First, we propose an effective NUC compensation method and a lens-specific sensitivity design method in terms of system. Second, we propose a zoom trajectory design method considering the temperature effect on the optical aspect. Third, it suggests the minimization of optical axis shaking between magnification conversion in terms of mechanism. Finally, we propose a lens-specific temperature compensation method and a speed conversion algorithm according to the zoom interval as an electronic aspect.

Research on Measurement of Infrared Thermograpphy under High Temperature Condition (고온 환경에서의 적외선 열화상 측정에 관한 연구)

  • Jun-Sik Lee;Jae-Wook Jeon
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.27 no.1
    • /
    • pp.57-62
    • /
    • 2024
  • This study conducted a measurement method of high temeprature conditions using infrared termography. All objects emit infrared light, and this emissivity has a significant impact on the temperature measurements of infrared thermal imaging (IR) cameras. In order to measure the temperature more accurately with the IR camera, correction equations were derived by measuring the emissivity according to the temperature change of combustible metals in a high-temperature environment. Two combustible metals, Mg and Al, were used to measure emissivity with changing temperature. Each metal was heated, the emissivity was measured by comparing the temperature with IR camera and thermocouples so that the correlation between temperature and emissivity could be anslyzed. As a result of the experiment, the emissivity of the metals increases as the temperature increased. This can be interpreted as a result of increased radiation emission as the thermal movement of internal metal molecules increased.

A Study on the Best Applicationsof Infra-Red(IR) Sensors Mounted on the Unmanned Aerial Vehicles(UAV) in Agricultural Crops Field (무인기 탑재 열화상(IR) 센서의 농작물 대상 최적 활용 방안 연구)

  • Ho-Woong Shon;Tae-Hoon Kim;Hee-Woo Lee
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.6_2
    • /
    • pp.1073-1082
    • /
    • 2023
  • Thermal sensors, also called thermal infrared wavelength sensors, measure temperature based on the intensity of infrared signals that reach the sensor. The infrared signals recognized by the sensor include infrared wavelength(0.7~3.0㎛) and radiant infrared wavelength(3.0~100㎛). Infrared(IR) wavelengths are divided into five bands: near infrared(NIR), shortwave infrared(SWIR), midwave infrared(MWIR), longwave infrared(LWIR), and far infrared(FIR). Most thermal sensors use the LWIR to capture images. Thermal sensors measure the temperature of the target in a non-contact manner, and the data can be affected by the sensor's viewing angle between the target and the sensor, the amount of atmospheric water vapor (humidity), air temperature, and ground conditions. In this study, the characteristics of three thermal imaging sensor models that are widely used for observation using unmanned aerial vehicles were evaluated, and the optimal application field was determined.

A Composite Camera Calibration Technique for Thermal Deterioration Diagnosis of Power Distribution Line (배전 선로의 열화 진단을 위한 복합 카메라 보정기법)

  • Jung, Ha-Hyoung;Park, Jin-ha;Lyou, Joon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.6
    • /
    • pp.463-469
    • /
    • 2016
  • This paper presents a composite camera calibration method to determine thermal degradation of power distribution equipment by combining an infrared (IR) camera and a color camera. A calibration jig was first constructed to match the properties of the two cameras. Our calibration and visualization techniques allow for the display of two images, one from the color camera and the other from the IR camera with different field of views (FOVs), on the screen at the same time. To confirm its validity, several case studies have been developed to analyze thermal deterioration limits of indoor and outdoor power distribution facilities.

The Development of Infrared Thermal Imaging Safety Diagnosis System Using Pearson's Correlation Coefficient (피어슨 상관계수를 이용한 적외선 열화상 안전 진단 시스템 개발)

  • Jung, Jong-Moon;Park, Sung-Hun;Lee, Yong-Sik;Gim, Jae-Hyeon
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.6
    • /
    • pp.55-65
    • /
    • 2019
  • With the rapid development of the national industry, the importance of electrical safety was recognized because of a lot of new electrical equipment are installing and the electrical accidents have been occurring annually. Today, the electrical equipments is inspect by using the portable Infrared thermal imaging camera. but the most negative element of using the camera is inspected for only state of heating, the reliable diagnosis is depended with inspector's knowledge, and real-time monitoring is impossible. This paper present the infrared thermal imaging safety diagnosis system. This system is able to monitor in real time, predict the state of fault, and diagnose the state with analysis of thermal and power data. The system consists of a main processor, an infrared camera module, the power data acquisition board, and a server. The diagnostic algorithm is based on a mathematical model designed by analyzing the Pearson's Correlation Coefficient between temperature and power data. To test the prediction algorithm, the simulations were performed by damaging the terminals or cables on the switchboard to generate a large amount of heat. Utilizing these simulations, the developed prediction algorithm was verified.

Thermo-Analysis of Machining Center Main-Axis Thermo-Displacement for Infrared Rays Thermo-Image Camera (적외선 열화상 카메라를 이용한 머시닝 센터 주축 열변위에 관한 열해석)

  • Kim, Jae-Yeol;Yoon, Sung-Un;Yim, Noh-Bin;Yu, Sin;Ma, Sang-Dong;Yang, Dong-Jo;Song, In-Suk
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2001.04a
    • /
    • pp.125-130
    • /
    • 2001
  • Diagnosis or measurements using Infrared thermo-image hasn t been available. A quick diagnosis and thermal analysis can be possible when that kind of system is introduced to the investigation of each part. In this study, Infrared Camera, Thermo-vision 900 was used in order to investigate. Infrared Camera usually detects only Infrared wave from the light in order to illustrate the temperature distribution. Infrared diagnosis system can be applied to various field. Also, it is more effective to analyze temperature distribution on the machining center main-axis process.

  • PDF

Malfunction Detection of High Voltage Equipment Using Microphone Array and Infrared Thermal Imaging Camera (Microphone Array와 열화상 카메라를 이용한 고압설비 고장검출)

  • Han, Sun-Sin;Choi, Jae-Young;Lee, Jang-Myung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.1
    • /
    • pp.25-32
    • /
    • 2010
  • The paper proposes a hierarchical fault detection method for the high voltage equipment using a microphone array which detects the location of fault and the thermal imaging and CCD cameras which verifies the fault and stores the image, respectively. There are partial arc discharges on the faulty insulators, which generates a specific pattern of sound. Detecting the signal using the microphone array, the location of the faulty insulator can be estimated. The 6th band-pass filter was applied to remove noise signal from wind or external influence. When the mobile robot carries the thermal and CCD cameras to the possible place of the fault insulator, the fault insulators or power transmission wires can be detected by the thermal images, which are caused by the aging or natural erosion. Finally, the CCD camera captures the image of the fault insulator for the record. The detection scheme of fault location using the microphone array and the thermal images have been proved to be effective through the real experiments. As a result of this research, it becomes possible to use a mobile robot with the integrated sensors to detect the fault insulators instead of a human being.