• Title/Summary/Keyword: Infrared thermal

Search Result 1,308, Processing Time 0.029 seconds

Effect of Thermal Segregation Reduction in Asphalt Paving with MTV (MTV를 적용한 아스팔트 포설에서 열분리 저감 효과)

  • Kweon, Gichul
    • International Journal of Highway Engineering
    • /
    • v.20 no.4
    • /
    • pp.1-6
    • /
    • 2018
  • PURPOSES : The objective of this study is to evaluate of the effect of thermal segregation reduction in asphalt paving using material transfer vehicles (MTVs). METHODS : Asphalt paving using MTVs was carried out, and the paved surface temperature was measured using an infrared camera. The amount of thermal segregation was estimated from temperature variations. RESULTS : The transportation of hot mix asphalt (HMA) using dump trucks caused temperature segregation that persisted in the paving surface if an MTV was not used. The average temperature variation was 8.58% in paved surfaces where an MTV was not used. However, the temperature variation was 3.10%, 2.86%, and 4.53% for the base layer, inter-layer, and surface layer, respectively, when an MTV was used. CONCLUSIONS : The use of an MTV in asphalt paving reduces thermal segregation approximately 2.3 times in an asphalt mat via a remixing process and also allows for a smoother work process because the paver never needs to stop to receive HMA. However, MTV equipment without pre-heating devices requires careful temperature control during the warm up process at the MTV during construction in the winter.

Malfunction Detection of High Voltage Equipment Using Microphone Array and Infrared Thermal Imaging Camera (Microphone Array와 열화상 카메라를 이용한 고압설비 고장검출)

  • Han, Sun-Sin;Choi, Jae-Young;Lee, Jang-Myung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.1
    • /
    • pp.25-32
    • /
    • 2010
  • The paper proposes a hierarchical fault detection method for the high voltage equipment using a microphone array which detects the location of fault and the thermal imaging and CCD cameras which verifies the fault and stores the image, respectively. There are partial arc discharges on the faulty insulators, which generates a specific pattern of sound. Detecting the signal using the microphone array, the location of the faulty insulator can be estimated. The 6th band-pass filter was applied to remove noise signal from wind or external influence. When the mobile robot carries the thermal and CCD cameras to the possible place of the fault insulator, the fault insulators or power transmission wires can be detected by the thermal images, which are caused by the aging or natural erosion. Finally, the CCD camera captures the image of the fault insulator for the record. The detection scheme of fault location using the microphone array and the thermal images have been proved to be effective through the real experiments. As a result of this research, it becomes possible to use a mobile robot with the integrated sensors to detect the fault insulators instead of a human being.

Defect Detection of Impacted Composite Tubes by Lock-in Photo-Infrared Thermography Technique (위상잠금 열화상기법을 이용한 복합재 튜브 충격 손상 결함 측정)

  • Kim, Kyoung-Suk;Jeon, So-Young;Jung, Hyun-Chul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.2
    • /
    • pp.139-143
    • /
    • 2011
  • The problem of delamination of composite tubes by impact has been acknowledged in aerospace and automobile industry. Non-destructive testing(NDT) methods in composite material structure are important to evaluate reliability of composite structure. There are many kinds of NDT methods which can detect the inside defect of the composite material such as Infrared Thermography(IRT). Infrared thermal imaging of object is different from that of a defect, in heated composite tubes with an internal defect, and then location and size of a defect can be measured by the analysis of thermal imaging pattern. In this study, Lock-in Infrared thermography detect internal defects of Impacted composite tubes by the inspection of infrared lay radiated from the surface of composite tubes.

A Study on Vulcanization of EPDM by Far-infrared (원적외선에 의한 EPDM의 가교 특성 연구)

  • Bae, J.W.;Kim, J.S.;Lee, J.H.;Jung, W.S.;Park, H.C.;Kang, D.P.
    • Elastomers and Composites
    • /
    • v.43 no.1
    • /
    • pp.1-7
    • /
    • 2008
  • Far-infrared vulcanization of ethylene-propylene-diene terpolymer(EPDM) compounds has been studied in comparison with hot air vulcanization. Vulcanization characteristics of EPDM compounds were measured by degree of curing and temperature of specimens in vulcanization process. As a result, degree of curing by far-infrared of EPDM compounds was shown to be higher value than that by hot air at the same vulcanization temperature. Especially, degree of curing by far-infrared on 3 mm thickness of EPDM compounds was increased by two times compared to that by hot air. While the increase of thermal conductivity of EPDM compounds highly improved degree of curing by far-infrared, that hardly improved degree of curing by hot air.

Infrared Detector Using Pyroelectrics

  • Hur, Chang-Wu
    • Journal of information and communication convergence engineering
    • /
    • v.4 no.4
    • /
    • pp.147-150
    • /
    • 2006
  • The thin film of PbTiO3 is fabricated at substrate temperature of 100-150$^{\circ}C$. The infrared spectrum of the ferroelectric thin film is measured as temperature of thermal treatment, 400 - 550$^{\circ}C$. According to infrared spectrum analysis, there are absorption bands at a nearby wave number of 1000 $\sim$ 400 cm-l and the thin film treated by temperature of 550$^{\circ}C$ has absorption bands of wave number 500 cm-l similar to infrared response property of PbTiO3 powder. The pyroelectric infrared detector is fabricated after deposition of Pt and PbTiO3 thin film on Si wafer by sputtering machine. The measured remnant polarization are 11.5-12.5$\muC/cm2$, breakdown electric field Ec is 100-120KV/cm, and voltage responsivity and detectivity is -280V/W, -108cm Hz/W.

Hot Spot Analysis on Brake Disc Using Infrared Camera (적외선카메라를 이용한 제동 디스크 열크랙 분석)

  • Kim, Jeong-Guk;Goo, Byeong-Choon;Kwon, Sung-Tae
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.964-968
    • /
    • 2008
  • Infrared thermography using high-speed infrared camera has been recognized as a powerful method for various potential applications, such as nondestructive inspection, failure analysis, stress analysis, and medical fields, due to non-contact, high-speed, and high spatial resolution at various temperature ranges. In this investigation, damage evolution due to generation of hot spots on railway brake disc was investigated using the infrared thermography method. A high-speed infrared camera was used to measure the surface temperature of brake disc as well as for in-situ monitoring of hot spot evolution. From the thermographic images, the observed hot spots and thermal damage of railway brake disc during braking operation were qualitatively analyzed. Moreover, in this investigation, the previous experimental and theoretical studies on hot spots phenomenon were reviewed, and the current experimental results were introduced and compared with theoretical prediction.

  • PDF

The Effect of $MnO_{2}$ on the Characteristics of an Infrared Radiator of Cordierite System with Pressing Method (成形法에 따른 Cordierite系 赤外線 放射體의 諸特性에 미치는 $MnO_{2}$의 影響)

  • 강이국;신용덕
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.44 no.6
    • /
    • pp.799-805
    • /
    • 1995
  • An infrared radiator of cordierite system were manufactured byslurry casting anddry pressing method. The characteristics of cordierite (2MgO.2Al$_{2}$O$_{3}$.5SiO$_{2}$)+30wt% clay+Xwt% MnO$_{2}$ of infrared radiator have been investigated as a function of MnO$_{2}$ additives (X=0, 0.1, 0.25, 0.5, 1.0, 1.5, 2.0, 2.5). The thermal expansioncoefficient was decreased with increasing amounts of MnO$_{2}$ additives. Otherwise, the spectral emissivity was increased in the below 4.5.mu.m wavelength. Also, the infrared radiator of cordierite system which spectral emissivity was approximately 1.0 can be attainable at from 4.5.mu.m to 8.mu.m wavelength. The spectral emissivity was decreased from 8.mu.m to 14.mu.m above X=2.5.

  • PDF

THERMAL DESIGN OF A PROTOMODEL SPACE INFRARED CRYOGENIC SYSTEM (적외선 우주망원경 냉각시스템 시험모델 열설계)

  • Yang Hyung-Suk;Kim Dong-Lak;Lee Byoung-Seob;Kim Geon-Hee;Lee Dae-Hee;Pak Soo-Jong;Nam Uk-Won
    • Journal of Astronomy and Space Sciences
    • /
    • v.23 no.2
    • /
    • pp.153-160
    • /
    • 2006
  • A Protomodel Space Infrared Cryogenic System (PSICS) cooled by a stirling cry-ocooler has been designed. The PSICS has an IR sensor inside the cold box which is cooled by a stirling cryocooler with refrigeration capacity of 500mW at 80K in a vacuum vessel. It is important to minimize the heat load so that the background thermal noise can be reduced. In order to design the cryogenic system with low heat load and to reduce the remained heat load, we have performed numerical analyses. In this paper, we present the design factors and the results obtained by the thermal analysis of the PSICS.

A Study on the Infrared Thermographic Imaging in Diagnosis of the Central Type of Herniated Disc (중앙형 추간판탈출증의 진단에서 체열촬영의 의의)

  • Song Bong-Keun;Lee Jong-Duk;Pak Yong-Hyun;Song Un-Yong;Kim Jung-Gyl
    • Journal of Acupuncture Research
    • /
    • v.15 no.2
    • /
    • pp.301-310
    • /
    • 1998
  • Infrared thermographic imaging visualizes noninvasively various abnormal condition by detecting the skin temperature. As the imaging represents the objective condition by the changes in blood flow under the control of autonomic nervous system, it is used to diagnosis and monitor the lumboscral radiculopathy. And asymmetry is important in the diagnosis of disc herniation. The most common type of disc herniation occurs psoterolaterally. This frequently causes nerve root compression leading to a radiculopathy in the distribution of the involved nerve root, most of which also provoke the asymmetric changes in thermography. Central disc herniation, which accounts for 5% to 35% of disc herniation, is typically associated with low back pain. But radiculopathy is usually abscent unless central disc heriniaton is large enough to cause compression of the cauda equina. To evalute the diagnostic value of the thermographic imaging in the diagnosis of central disc herniation, the imaging of 15 normal subjects and 48 patients with central disc herniation documented by CT scan were analyzed. The patients had either bilateral radiculophathy or no radiculopathy. The imaging of patient group with non rediculopathy did not show any significant thermal difference to control. While bilateral radiculopathy group reveled hypothermic pattern compared twith control. Thermal difference between left and right side did not present any significance in non radiculopathy group but hypothermia in bilateral radiculopathy group. Large herniation group demonstrated hyperthemic pattern while the others showed no significant change. Cranial caudal thermal difference did not show any difference between experiment groups. These results shows that infrared thermographic imaging can be used central disc herniation with bilateral radiculopathy, while it seems to little useful on the diagnosis of non radiculopathic disc herniation.

  • PDF

Phenotyping of Low-Temperature Stressed Pepper Seedlings Using Infrared Thermography

  • Park, Eunsoo;Hong, Suk-Ju;Lee, Ah-Yeong;Park, Jongmin;Cho, Byoung-Kwan;Kim, Ghiseok
    • Journal of Biosystems Engineering
    • /
    • v.42 no.3
    • /
    • pp.163-169
    • /
    • 2017
  • Purpose: This study was performed to evaluate the feasibility of using an infrared thermography technique for phenotype analysis of pepper seedlings exposed to a low-temperature environment. Methods: We employed an active thermography technique to evaluate the thermal response of pepper seedlings exposed to low-temperature stress. The temperatures of pepper leaves grown in low-temperature conditions ($5^{\circ}C$, relative humidity [RH] 50%) for four periods (6, 12, 24, and 48 h) were measured in the experimental setting ($23^{\circ}C$, RH 70%) as soon as pepper seedling samples were taken out from the low-temperature environment. We also assessed the visible images of pepper seedling samples that were exposed to low-temperature stress to estimate appearance changes. Results: The greatest appearance change was observed for the low-temperature stressed pepper seedlings that were exposed for 12 h, and the temperature from these pepper seedling leaves was the highest among all samples. In addition, the thermal image of low-temperature stressed pepper seedlings for 6 h exhibited the lowest temperature. Conclusions: We demonstrated that the leaf withering owing to the water deficiency that occurred under low-temperature conditions could induce an increase in temperature in plant leaves using the infrared thermography technique. These results suggested that the time-resolved and averaged thermal signals or temperatures of plants could be significantly associated with the physiological or biochemical characteristics of plants exposed to low-temperature stress.