• Title/Summary/Keyword: Infrared thermal

Search Result 1,308, Processing Time 0.032 seconds

Studies on AlF3-(Mg+Sr+Ba)F2-P2O5 Glasses II. Effect of MgF2 Contents (AlF3-(Mg+Sr+Ba)F2-P2O5계 유리에 관한 연구 제2보 : MgF2의 영향)

  • 김정은;이종근
    • Journal of the Korean Ceramic Society
    • /
    • v.24 no.3
    • /
    • pp.277-281
    • /
    • 1987
  • The various contents of MgF2 from 0 to 12.5wt% are studied in the AlF3-(Mg+Sr+Ba)F2-P2O5 system for the effects of various properties in glasses and the atmosphere of melting was controlled by N2 and Ar gas respectively. Density, refractive index, infrared transmission, thermal conductivity and thermal expansion coefficient of glasses are determined. Density, refractive index and thermal conductivity are decreased, micro-hardness and thermal expansion coefficient are increased according to the increasing of MgF2 contents. Infrared transmittance decreases with increasing the MgF2 contents and it slightly dropped by air than N2 and Ar atmosphere. Other properties are not influenced by atmosphere control.

  • PDF

Thermal environment analysis of greenhouse using Thermo-tracer (Thermo-tracer를 이용한 온실의 열환경 분석)

  • 이석건;이종원;이현우;김란숙
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.230-236
    • /
    • 1998
  • Thermal environment of greenhouse was investigated by thermo-tracer in this study. The Thermo-tracer is a high-sensitivity infrared thermometer of non-contact type. The infrared energy emitted from the measured object is converted into an electrical signal by the detector(HgCdTe) and display as a color or black & white thermal image by way of optical scanning, The experiment was conducted for Venlo-type greenhouse with pad & fan system. The temperature difference between measured by Thermo-trace and measured by HOBO sensor is maximum 0.8$^{\circ}C$. Thermo-trace is possible to use for the thermal environment analysis and diagnosis of a cooling and heating system of greenhouse.

  • PDF

Contour Integral Method for Crack Detection

  • Kim, Woo-Jae;Kim, No-Nyu;Yang, Seung-Yong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.6
    • /
    • pp.665-670
    • /
    • 2011
  • In this paper, a new approach to detect surface cracks from a noisy thermal image in the infrared thermography is presented using an holomorphic characteristic of temperature field in a thin plate under steady-state thermal condition. The holomorphic function for 2-D heat flow field in the plate was derived from Cauchy Riemann conditions to define a contour integral that varies according to the existence and strength of a singularity in the domain of integration. The contour integral at each point of thermal image eliminated the temperature variation due to heat conduction and suppressed the noise, so that its image emphasized and highlighted the singularity such as crack. This feature of holomorphic function was also investigated numerically using a simple thermal field in the thin plate satisfying the Laplace equation. The simulation results showed that the integral image selected and detected the crack embedded artificially in the plate very well in a noisy environment.

Diagnostic of Cast Resin Using Active Infrared Thermal Testing Method (능동열시험법을 이용한 몰드변압기 진단)

  • Lim, Young-Bae;Jeong, Seung-Cheon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.481-484
    • /
    • 2004
  • A form of measured temperature distribution to estimate condition of a electrical apparatus is a absolute reference for condition of the apparatus, time rate of transition, and difference between reference and currently temperature. Because passive thermography which has not injection of external thermal stimulation shows difference of temperature being on surface of a structure and temperature difference between the structure and back ground, the result could apply only to estimation or monitor for condition of terminal relaxation and overload related with temperature rising. However, a thermal flow in active thermography is differently generated by structure and condition of surface and subsurface. This paper presents the nondestructive testing using the properties and includes the results by heat injection and cooling to the apparatus. The buried discontinuity of subsurface could be detected by these techniques.

  • PDF

The Friction Characteristic and Distribution of Temperature in The Continuous Braking Effort on The Train Control (열차 제어의 연속 제동시 마찰특성과 온도분포)

  • Choi K.S.;Lee S.W.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.55-58
    • /
    • 2005
  • During braking at a train, thermal energy is generated due to the frictions between disk and lining and wheel and shoe. In general, the braking transfers the kinetic energy into thermal energy. Therefore, the frictional characteristics are varied according to the braking force, the thermal resistance, and the thermostable, etc. Using a Dynamo testing we have studied the frictional characteristics and the thermal distribution to investigate a stable speed and to improve the testing method through comparing and analysing in the measurement of the thermocouple temperature and infrared camera.

  • PDF

An Experimental Study for Characteristics Evaluation of Cement Mortar Using Infrared Thermography Technique (적외선 화상기법을 이용한 시멘트 모르타르 특성의 실험적 평가)

  • Kwon, Seung-Jun;Maria, Q. Feng
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.1A
    • /
    • pp.53-59
    • /
    • 2010
  • Recently, NDTs (Non-Destructive Techniques) using infrared camera are widely studied for detection of damage and void in RC (reinforced concrete) structures and they are also considered as an effective techniques for maintenance of infrastructures. The temperature on concrete surface depends on material and thermal properties such as specific heat, thermal conductivity, and thermal diffusion coefficient. Different porosity on cement mortar due to different mixture proportions can show different heat behavior in cooling stage. The porosity can affect physical and durability properties like strength and chloride diffusion coefficient as well. In this paper, active thermography which uses flash for heat induction is utilized and thermal characteristics on surface are evaluated. Samples of cement mortar with W/C (water to cement ratio) of 0.55 and 0.65 are prepared and physical properties like porosity, compressive strength, and chloride diffusion coefficient are evaluated. Then infrared thermography technique is carried out in a constant room condition (temperature $20{\sim}22^{\circ}C$ and relative humidity 55-60%). The mortar samples with higher porosity shows higher residual temperature at the cooling stage and also shows reduced critical time which shows constant temperature due to back wall effect. Furthermore, simple equation for critical time of back wall effect is suggested with porosity and experimental constants. These characteristics indicate the applicability of infrared thermography as an NDT for quality assessment of cement based composite like concrete. Physical properties and thermal behavior in cement mortar with different porosity are analyzed in discussed in this paper.

A Comparative Study on Electron-Beam and Thermal Curing Properties of Epoxy Resins (에폭시 수지의 전자선 및 열경화 특성에 관한 연구)

  • 이재락;허건영;박수진
    • Polymer(Korea)
    • /
    • v.26 no.1
    • /
    • pp.80-87
    • /
    • 2002
  • A comparative study using electron-beam(EB) and thermal curing techniques was carried out to determine the effect of cure behavior and thermal stability of epoxy resins. In this work, benzylquinoxalinium hexafluoroantimonate(BQH) was used as a latent cationic catalyst for an epoxy resin. According to the thermogravimetric analysis(TGA), the decomposed activation energy based on Coats-Redfern method was higher in the case of thermal curing technique. This could be interpreted in terms of slow thermal diffusion rate resulted from high crosslink density of the thermally cured epoxy resin. However, the increase of hydroxyl group in the epoxy resin cured by EB technique was observed in near-infrared spectroscopy(NIRS) measurements, resulting in improving the stable short aromatic chain structure, integral procedural decomposition temperature, and finally ductile properties for high impact strengths.

Detection of Thermal Plume Signature in and around the Younggwang coastal waters of Korea using LANDSAT & NOAA Thermal Infrared Data

  • Ahn, Yu-Hwan;Shanmugam, P.;Lee, Jae-Hak;Kang, Yong Q.
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.869-872
    • /
    • 2003
  • The thermal contamination of the Younggwang coastal marine ecosystem has been investigated using space borne thermal infrared data acquired over the period 1985-2003 by the Landsat and NOAA satellites. The analysis of AVHRR data brought out the general pattern and extension of thermal plume while TM data yielded more accurate information about the plume shape, dimension, dispersion direction etc. The examination of sea surface temperature (SST) computed from these images clearly indicates that the thermal plume extends 70 to100km southward during summer and 50 to70km northwestward during winter monsoons. The maximum plume temperature was 29$^{\circ}C$ in summer and 12$^{\circ}C$ in winter. The comparative analysis shows that the temperature retrieved from TM is slightly higher (1.8$^{\circ}C$, 3$^{\circ}C$ and 2.2$^{\circ}C$ for the images of 98/11/10, 99/05/05 and 99/05/21 respectively) than those derived from AVHRR data. The correlation coefficient between the TM-derived SST and AVHRR-derived SST was 0.72.

  • PDF

Infrared Imaging for Screening Breast Cancer Metastasis Based on Abnormal Temperature Distribution

  • Ovechkin Aleck M.;Yoon Gilwon
    • Journal of the Optical Society of Korea
    • /
    • v.9 no.4
    • /
    • pp.157-161
    • /
    • 2005
  • Medical infrared imaging is obtained by measuring the self-emitted infrared radiance from the human body. Infrared emission is related to surface temperature and temperature is one of the most important physiological parameters related to health. Though recent applications such as security identification and oriental medicine have provided new fields of biomedical applications, infrared thermography has had ups and downs in its usages in cancer detection. Some of the main difficulties include finding proper applications and efficient diagnostic algorithms. In this study, infrared thermal imaging was used to detect regional metastasis of breast cancer. Our measurements were done for 110 women. From 63 individuals of a Healthy Group and a Benign Breast Disease Group, we developed algorithms for differentiating malignant regional metastasis based on temperature difference and asymmetry of temperature distribution. Testing with 47 cancer patients, we achieved a positive predictive value of $87.5\%$ and a negative predictive value of $95.6\%$. The results were better than for mammogram examination. A proper analysis of infrared imaging proved to be a highly informative and sensitive method for differentiating regional cancer metastasis from normal regions.

The Effectiveness of Infrared Thermography in Patients with Whiplash Injury

  • Lee, Young Seo;Paeng, Sung Hwa;Farhadi, Hooman F.;Lee, Won Hee;Kim, Sung Tae;Lee, Kun Su
    • Journal of Korean Neurosurgical Society
    • /
    • v.57 no.4
    • /
    • pp.283-288
    • /
    • 2015
  • Objective : This study aims to visualize the subjective symptoms before and after the treatment of whiplash injury using infrared (IR) thermography. Methods : IR thermography was performed for 42 patients who were diagnosed with whiplash injury. There were 19 male and 23 female patients. The mean age was 43.12 years. Thermal differences (${\Delta}T$) in the neck and shoulder and changes in the thermal differences (${\Delta}dT$) before and after treatment were analyzed. Pain after injury was evaluated using visual analogue scale (VAS) before and after treatment (${\Delta}VAS$). The correlations between ${\Delta}dT$ and ${\Delta}VAS$ results before and after the treatment were examined. We used Digital Infrared Thermal Imaging equipment of Dorex company for IR thermography. Results : The skin temperature of the neck and shoulder immediately after injury showed $1-2^{\circ}C$ hyperthermia than normal. After two weeks, the skin temperature was normal range. ${\Delta}T$ after immediately injuy was higher than normal value, but it was gradually near the normal value after two weeks. ${\Delta}dT$ before and after treatment were statistically significant (p<0.05). VAS of the neck and shoulder significantly reduced after 2 week (p=0.001). Also, there was significant correlation between ${\Delta}dT$ and reduced ${\Delta}VAS$ (the neck; r=0.412, p<0.007) (the shoulder; r=0.648, p<0.000). Conclusion : The skin temperature of sites with whiplash injury is immediately hyperthermia and gradually decreased after two weeks, finally it got close to normal temperature. These were highly correlated with reduced VAS. IR thermography can be a reliable tool to visualize the symptoms of whiplash injury and the effectiveness of treatment in clinical settings.