• 제목/요약/키워드: Infrared images(IR)

검색결과 123건 처리시간 0.03초

BMVT-M을 이용한 IR 및 SAR 융합기반 지상표적 탐지 (IR and SAR Sensor Fusion based Target Detection using BMVT-M)

  • 임윤지;김태훈;김성호;송우진;김경태;김소현
    • 제어로봇시스템학회논문지
    • /
    • 제21권11호
    • /
    • pp.1017-1026
    • /
    • 2015
  • Infrared (IR) target detection is one of the key technologies in Automatic Target Detection/Recognition (ATD/R) for military applications. However, IR sensors have limitations due to the weather sensitivity and atmospheric effects. In recent years, sensor information fusion study is an active research topic to overcome these limitations. SAR sensor is adopted to sensor fusion, because SAR is robust to various weather conditions. In this paper, a Boolean Map Visual Theory-Morphology (BMVT-M) method is proposed to detect targets in SAR and IR images. Moreover, we suggest the IR and SAR image registration and decision level fusion algorithm. The experimental results using OKTAL-SE synthetic images validate the feasibility of sensor fusion-based target detection.

컬러 영상과 근적외선 영상을 이용한 영상 융합 (Image Fusion using RGB and Near Infrared Image)

  • 길태호;조남익
    • 방송공학회논문지
    • /
    • 제21권4호
    • /
    • pp.515-524
    • /
    • 2016
  • 근적외선은 눈에 보이는 가시광선 파장 대역을 벗어난 빛으로 일반적인 디지털 카메라에서는 핫미러 필터에 의하여 차단된다. 하지만 근적외선으로부터 얻어지는 정보들은 영상의 전체적인 가시성을 향상시킬 수 있다고 알려져 있기 때문에 영상의 질 개선에 유용한 정보가 될 수 있다. 예를 들어 영상에 안개가 낀 경우, 근적외선은 가시광선보다 안개 입자에 대한 침투성이 더 강하다는 성질을 가지고 있기 때문에 근적외선 카메라로 영상을 촬영하면 일반적인 카메라 영상보다 더 선명한 영상을 얻을 수 있다. 본 논문은 실외 영상의 질을 높이기 위해 컬러 영상과 근적외선 영상을 융합하는 알고리즘을 제안한다. 첫 번째로, 본 논문은 컬러 영상과 근적외선 영상의 대비를 비교하여 가중치 맵을 구한다. 그 후, 이 가중치 맵을 이용하여 두 영상을 융합하는 과정을 거치게 된다. 본 논문은 실험 결과들을 통해서 제안하는 알고리즘이 효과적으로 영상의 질을 높이고, 또한 안개를 제거하는 것을 보여준다.

적응적 구조요소를 이용한 열림 연산자에 의한 적외선 영상표적 추출 (Shape Extraction of Near Target Using Opening Operator with Adaptive Structure Element in Infrared hnages)

  • 권혁주;배태욱;김병익;이성학;김영춘;안상호;송규익
    • 한국통신학회논문지
    • /
    • 제36권9C호
    • /
    • pp.546-554
    • /
    • 2011
  • 적외선 영상의 근거리 표적 (near targets)은 표적의 내부영역은 화소 값이 균일하고, 경계 영역은 배경과 인접해 있기 때문에 화소 값 변화가 불균일하다. 이러한 특성에 기초하여 본 논문은 적응적 구조요소 (adaptive structure element)를 이용한 열림 연산자에 의한 적외선 영상 표적 검출 기법을 제안한다 먼저, 국부 분산 가중치 정보 엔트로피 (weighted information entropy, WIE)를 이용하여 후보 표적군의 위치와 경계영역을 추출한 후, 이 경계 영역에 대하여 라벨링 연산을 수행하여 대략의 표적 영역을 검출한다. 이 대략의 표적 영역에 대하여 제한한 적응적 구조 요소를 이용한 열림 연산자를 수행함으로써 정확한 표적 모양을 검출한다. 이 구조 요소는 표적 경계 영역에서 필터창의 가중치 정보 엔트로피의 평균값을 계산함으로써 얻어진 표적 경계 폭에 의한 결정된다. 실험 결과로부터 제안한 방법이 기존의 방법에 비해 추출 성능이 뛰어남을 확인할 수 있었다.

밝기 차, 유사성, 근접성을 이용한 적응적 표적 검출 알고리즘 (Adaptive Target Detection Algorithm Using Gray Difference, Similarity and Adjacency)

  • 이은영;구은혜;유현정;박길흠
    • 한국통신학회논문지
    • /
    • 제38B권9호
    • /
    • pp.736-743
    • /
    • 2013
  • 적외선 탐색 및 추적 시스템에서 원거리에 표적이 존재할 경우 표적의 크기가 매우 작고, 해무와 같은 클러터와 다양한 센서 잡음으로 인해 표적의 검출이 매우 어렵다. 특히 표적의 화소 값과 유사한 잡음이나 클러터가 존재하는 경우 일반적인 임계화 기법을 적용하는 경우 표적의 오검출 위험이 매우 높다. 이러한 이유로 본 논문에서는 영상의 밝기 정보와 표적에 대한 사전 정보를 이용하여 최적의 표적 검출 결과를 도출하기 위한 적응적 임계화 기법을 제안한다. 소형 표적을 강조하기 위하여 인간 시각 시스템을 반영한 CSF(Contrast Sensitivity Function)를 적용하고, 표적이 강조된 영상에서 영상의 밝기 정보와 거리 정보를 이용하여 표적을 검출한다. 다양한 환경 조건에서 획득된 적외선 영상에 대한 실험 결과들은 제안 알고리즘의 견실한 성능을 보여준다.

IR 영상을 이용한 교통영상에서의 야간장애물 검지 기법 (Obstacle Detection in Nighttime Traffic Scenes using IR Images)

  • 박동렬;박영태
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 추계종합학술대회 논문집
    • /
    • pp.633-636
    • /
    • 1999
  • We present a robust scheme of detecting obstacles such as vehicles, human beings, and other artificial structures that may cause serious traffic accidents in the nighttime driving. Obstacle regions are detected by the evidential reasoning rules that combine the isolated regions obtained by the phase-directed edge-linking and the hot evidence information. Preliminary experimental results show that the performance is robust to nighttime infrared scenes having various types of obstacles

  • PDF

Adaptive Histogram Projection And Detail Enhancement for the Visualization of High Dynamic Range Infrared Images

  • Lee, Dong-Seok;Yang, Hyun-Jin
    • 한국컴퓨터정보학회논문지
    • /
    • 제21권11호
    • /
    • pp.23-30
    • /
    • 2016
  • In this paper, we propose an adaptive histogram projection technique for dynamic range compression and an efficient detail enhancement method which is enhancing strong edge while reducing noise. First, The high dynamic range image is divided into low-pass component and high-pass component by applying 'guided image filtering'. After applying 'guided filter' to high dynamic range image, second, the low-pass component of the image is compressed into 8-bit with the adaptive histogram projection technique which is using global standard deviation value of whole image. Third, the high-pass component of the image adaptively reduces noise and intensifies the strong edges using standard deviation value in local path of the guided filter. Lastly, the monitor display image is summed up with the compressed low-pass component and the edge-intensified high-pass component. At the end of this paper, the experimental result show that the suggested technique can be applied properly to the IR images of various scenes.

Common Optical System for the Fusion of Three-dimensional Images and Infrared Images

  • Kim, Duck-Lae;Jung, Bo Hee;Kong, Hyun-Bae;Ok, Chang-Min;Lee, Seung-Tae
    • Current Optics and Photonics
    • /
    • 제3권1호
    • /
    • pp.8-15
    • /
    • 2019
  • We describe a common optical system that merges a LADAR system, which generates a point cloud, and a more traditional imaging system operating in the LWIR, which generates image data. The optimum diameter of the entrance pupil was determined by analysis of detection ranges of the LADAR sensor, and the result was applied to design a common optical system using LADAR sensors and LWIR sensors; the performance of these sensors was then evaluated. The minimum detectable signal of the $128{\times}128-pixel$ LADAR detector was calculated as 20.5 nW. The detection range of the LADAR optical system was calculated to be 1,000 m, and according to the results, the optimum diameter of the entrance pupil was determined to be 15.7 cm. The modulation transfer function (MTF) in relation to the diffraction limit of the designed common optical system was analyzed and, according to the results, the MTF of the LADAR optical system was 98.8% at the spatial frequency of 5 cycles per millimeter, while that of the LWIR optical system was 92.4% at the spatial frequency of 29 cycles per millimeter. The detection, recognition, and identification distances of the LWIR optical system were determined to be 5.12, 2.82, and 1.96 km, respectively.

적외선 센서 교정용 위성 탑재 흑체 시스템의 궤도 환경 열성능 평가 시험 (Thermal Performance Test of the On-Board Blackbody System in the orbital environment for Non-Uniformity Correction of an Infrared Sensor)

  • 최필경;김혜인;오현웅;유병철;이경묵;홍진석
    • 항공우주시스템공학회지
    • /
    • 제16권6호
    • /
    • pp.90-98
    • /
    • 2022
  • EO/IR 위성에 탑재된 적외선 센서(IR Sensor)는 궤도환경에서 임무기간 동안 복사 에너지에 대한 센서 출력의 변화가 발생한다. 고품질 영상을 획득하기 위해 출력을 교정할 수 있는 주기적인 교정이 필요하며, 센서의 주기적이고 정밀한 교정을 위해 탑재체 내부에 흑체 시스템이 적용하였다. 우주 환경에서 사용되는 모든 시스템은 궤도환경에서의 목표 성능을 검증하기 위해 지상에서의 성능시험이 요구되고 있다. 흑체 시스템은 운용환경에서 목표 온도 범위에서 대표추정온도 오차와 흑체 표면온도균일도 성능의 시험적 검증이 요구되고 있다. 본 연구에서는, 궤도환경으로 우주배경복사 냉각이 모사된 열진공 시험을 통해 제안된 흑체 시스템의 대표추정온도 오차 교정 및 성능 검증을 진행하였다.

Neurilemmoma of Deep Peroneal Nerve Sensory Branch : Thermographic Findings with Compression Test

  • Ryu, Seung Jun;Zhang, Ho Yeol
    • Journal of Korean Neurosurgical Society
    • /
    • 제58권3호
    • /
    • pp.286-290
    • /
    • 2015
  • We report a case of neurilemmoma of deep peroneal nerve sensory branch that triggered sensory change with compression test on lower extremity. After resection of tumor, there are evoked thermal changes on pre- and post-operative infrared (IR) thermographic images. A 52-year-old female presented with low back pain, sciatica, and sensory change on the dorsal side of the right foot and big toe that has lasted for 9 months. She also presented with right tibial mass sized 1.2 cm by 1.4 cm. Ultrasonographic imaging revealed a peripheral nerve sheath tumor arising from the peroneal nerve. IR thermographic image showed hyperthermia when the neurilemoma induced sensory change with compression test on the fibular area, dorsum of foot, and big toe. After surgery, the symptoms and thermographic changes were relieved and disappeared. The clinical, surgical, radiographic, and thermographic perspectives regarding this case are discussed.

Development of PKNU3: A small-format, multi-spectral, aerial photographic system

  • Lee Eun-Khung;Choi Chul-Uong;Suh Yong-Cheol
    • 대한원격탐사학회지
    • /
    • 제20권5호
    • /
    • pp.337-351
    • /
    • 2004
  • Our laboratory originally developed the compact, multi-spectral, automatic aerial photographic system PKNU3 to allow greater flexibility in geological and environmental data collection. We are currently developing the PKNU3 system, which consists of a color-infrared spectral camera capable of simultaneous photography in the visible and near-infrared bands; a thermal infrared camera; two computers, each with an 80-gigabyte memory capacity for storing images; an MPEG board that can compress and transfer data to the computers in real-time; and the capability of using a helicopter platform. Before actual aerial photographic testing of the PKNU3, we experimented with each sensor. We analyzed the lens distortion, the sensitivity of the CCD in each band, and the thermal response of the thermal infrared sensor before the aerial photographing. As of September 2004, the PKNU3 development schedule has reached the second phase of testing. As the result of two aerial photographic tests, R, G, B and IR images were taken simultaneously; and images with an overlap rate of 70% using the automatic 1-s interval data recording time could be obtained by PKNU3. Further study is warranted to enhance the system with the addition of gyroscopic and IMU units. We evaluated the PKNU 3 system as a method of environmental remote sensing by comparing each chlorophyll image derived from PKNU 3 photographs. This appraisement was backed up with existing study that resulted in a modest improvement in the linear fit between the measures of chlorophyll and the RVI, NDVI and SAVI images stem from photographs taken by Duncantech MS 3100 which has same spectral configuration with MS 4000 used in PKNU3 system.