• 제목/요약/키워드: Infrared curing

검색결과 64건 처리시간 0.021초

Effects of radiant exposure and wavelength spectrum of light-curing units on chemical and physical properties of resin cements

  • Lima, Adriano Fonseca;Formaggio, Stephanie Ellen Ferreira;Zambelli, Ligia Franca Aires;Palialol, Alan Rodrigo Muniz;Marchi, Giselle Maria;Saraceni, Cintia Helena Coury;de Oliveira, Marcelo Tavares
    • Restorative Dentistry and Endodontics
    • /
    • 제41권4호
    • /
    • pp.271-277
    • /
    • 2016
  • Objectives: In this study, we evaluated the influence of different radiant exposures provided by single-peak and polywave light-curing units (LCUs) on the degree of conversion (DC) and the mechanical properties of resin cements. Materials and Methods: Six experimental groups were established for each cement (RelyX ARC, 3M ESPE; LuxaCore Dual, Ivoclar Vivadent; Variolink, DMG), according to the different radiant exposures (5, 10, and $20J/cm^2$) and two LCUs (single-peak and polywave). The specimens were made (7 mm in length ${\times}$ 2 mm in width ${\times}$ 1 mm in height) using silicone molds. After 24 hours of preparation, DC measurement was performed using Fourier transform infrared spectrometry. The same specimens were used for the evaluation of mechanical properties (flexural strength, FS; elastic modulus, E) by a three-point bending test. Data were assessed for normality, after which two-way analysis of variance (ANOVA) and post hoc Tukey's test were performed. Results: No properties of the Variolink cement were influenced by any of the considered experimental conditions. In the case of the RelyX ARC cement, DC was higher when polywave LCU was used; FS and E were not influenced by the conditions evaluated. The LuxaCore cement showed greater sensitivity to the different protocols. Conclusions: On the basis of these results, both the spectrum of light emitted and the radiant exposure used could affect the properties of resin cements. However, the influence was material-dependent.

Evaluation of physical property and cytotoxicity of resin infiltrant based on a triethylene glycol dimethacrylate (TEGDMA)

  • Min, Ji-Hyun;Roh, Ji-Yeon;Kim, Ki-Rim
    • 한국치위생학회지
    • /
    • 제19권2호
    • /
    • pp.173-181
    • /
    • 2019
  • Objectives: The resin infiltration technique is a promising alternative therapy for arresting the early dental caries. However, there are very few reports on the safety and biocompatibility of this technique. We evaluated various properties of resin infiltrant (RI) based on a triethylene glycol dimethacrylate (TEGDMA).The water sorption (Wsp) and water solubility (Wsl) was assessed. Additionally, the cytotoxicity of RI against both animal and human fibroblast cell lines was investigated. Methods: The RI of the $Icon^{(R)}$, the first product developed for resin infiltration, is mainly composed of TEGDMA in the resin matrix. The Wsp and Wsl for the RI were measured in accordance with ISO 4049 specifications. Fourier-transform infrared spectroscopy (FTIR) was used for analyzing the polymerization before and after curing of RI. The cytotoxicity of RI against the mouse fibroblasts (L929) and human gingival fibroblasts (hTERT-hNOF) was evaluated using MTT [3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide] assay and the data were analyzed using one-way analysis of variance. Results: Wsp and Wsl of the RI specimens were $53.37{\mu}g/mm^3$ and $10.6{\mu}g/mm^3$, respectively. FTIR analysis revealed a slightly higher degree of curing with longer irradiation time. The degree of conversion for RI was high (80.9%) after 40 seconds of light curing. There was a significant decrease in the viability of L929 and hTERT-hNOF cells at RI extraction solution concentrations above 50%, respectively, compared to that in the negative control (p< 0.05). Conclusions: Even though the RI exhibited positive effect on the early prevention of dental caries, the clinicians should also consider the toxicity of RI on periodontal tissues.

백회와 사신총 혈위에 적합한 침구 소자의 개발 (The Development of Acupuncture- Moxibustion Device for 4 points around GV20(Baihui))

  • 조봉관
    • 대한한의진단학회지
    • /
    • 제19권2호
    • /
    • pp.101-108
    • /
    • 2015
  • Objectives This paper focused on developing the acupuncture-moxibustion device for head. Disadvantages of the existing devices for head moxibustion are its hume and inconvenience in operating because of the hair. Methods The proposed acupuncture-moxibustion device for GV20(Baihui) is 10mm long as needle body and 6mm long as needle root whose feature are 1~2 turns spiral coil. The spiral coil contains the moxa in order not to drop the moxa while operating Results The direct temperature on the burning moxa were measured by TK-305 infrared thermometer. But the direct temperature on the needle of acupuncture-moxibustion device were not able to measure by TK-305 infrared thermometer. By definition equation, the indirect temperatures on the needle of acupuncture-moxibustion device were able to be calculated. Conclusion A very safe, small and cheap acupuncture-moxibustion device for GV20(Baihui) of head is proposed. It will be useful to generate the heat shock protein and to operate in preventing and curing the Alzheimer's disease.

조사광이 통과하는 치질의 두께와 광조사시간에 따른 광중합형 복합레진의 중합률에 관한 연구 (A STUDY ON THE DEGREE OF CONVERSION OF LIGHT CURING COMPOSITE RESIN ACCORDING TO THE THICKNESS OF TOOTH STRUCTURE PENETRATED BY LIGHT AND APPLIED LIGHT CURING TIME)

  • 황기환;장인호;이세준;이광원
    • Restorative Dentistry and Endodontics
    • /
    • 제27권1호
    • /
    • pp.16-23
    • /
    • 2002
  • Physical properties of composite resins such as strength, resistance to wear, discoloration, etc depend on the degree of conversion of the resin components. The purpose of this study was to evaluate the degree of conversion of the composite resins according to the thickness of tooth structure penetrated by light and applied light curing time. The coronal portions of extracted human teeth (one anterior tooth, three posterior tooth) was embedded by pink denture material. the mounted teeth were cut into three illumination sections (1mm thickness enamel section, 1mm thickness dentin section, 2mm thicknes dentin section) and one backing section with cutting wheel. Thin resin films were made by using 6kg pressure between slide glass during 5 minutes Thin resin film was light cured on coupled illumination section during 40sec, 80sec and 120sec. each illumination section was coupled as follows; no tooth structure(X), ename section(E), enamel section + 1mm dentin section(ED1), enamel section + 2mm dentin section(ED2), enamel section + 1mm dentin section + 2mm dentin section(EDD). To simulate the clinical situation more closely, thin resin films was cured against a backing section of tooth structure. The degree of conversion of carbon double bonds to single bonds in the resin films were examined by means of Fourier Transform Infrared Spectrometer. The results were obtained as follows ; 1 As curing time was increased, conversion rate was increased and as tooth thickness which was penetrated by curing light was increased, conversion rate was decreased. 2. At all tooth thickness groups, conversion rate between 80sec and 120sec was not significantly increased(P>0.05). 3. At 40sec group and 80sec, conversion rate between no tooth structure(X) group and 1mm enamel section(E) group was not significantly decreased(P>0.05). 4. At 80sec group and 120sec, conversion rate between 1mm enamel section(E) group and 1mm enamel section + 1mm dentin section(ED1) group was not significantly decreased(P>0.05).

중합시간과 중합방법에 따른 자가중합형 상교정용 레진의 중합률의 비교에 관한 연구 (A STUDY ON THE DEGREE OF POLYMERIZATION OF AUTOPOLYMERIZED RESIN FOR REMOVABLE ORTHODONTIC APPLIANCE ACCORDING TO CURING TIME AND CURING METHOD)

  • 유종욱;장기택;김종철
    • 대한소아치과학회지
    • /
    • 제26권2호
    • /
    • pp.296-309
    • /
    • 1999
  • 가철성 상교정 장치에 많이 사용되는 자가중합형 상교정용 레진의 미반응 단량체는 레진의 물성과 생물학적인 면에 많은 영향을 끼친다. 따라서 미반응 단량체를 최소화하고 중합률을 최대로 하는 중합방법에 대한 연구는 중요한 의의를 갖는다. 저자는 자가중합형 상교정용 레진의 중합시간과 중합방법에 따른 중합률을 비교해보기 위해 시편을 다음과 같이 5군으로 나누어 연구를 진행하였다. 상교정용 레진의 분말과 용액을 혼합하여 제 1군은 $28^{\circ}C$의 공기중에 보관하였고, 제 2군은 $28^{\circ}C$의 물에, 제 3군은 $28^{\circ}C$의 물과 30psi의 압력에, 제 4군은 $43^{\circ}C$의 물에, 제 5군은 $43^{\circ}C$의 물과 30psi의 압력하에 각각 보관하였고, 10분, 1시간, 12시간, 1일, 3일 경과 후에 각 시편을 Fourier 변환적외선분광법을 이용하여 중합률을 측정하여 다음과 같은 결론을 얻었다. 1. 모든 군에서 중합시간이 경과함에 따라 중합률도 지속적으로 증가하는 양상을 보였다. 10분 경과 후의 결과와 비교하여 볼 때, 제 1군은 12시간 경과 후부터 중합률의 증가가 유의성이 있었고, 제 2군과 3군, 4군, 5군은 1시간 경과 후부터 유의성이 있었다(p<0.05). 2. 10분과 1일, 3일 경과 후에 제 5군, 제 4군, 제 3군, 제 2군, 제 1군의 순서대로 중합률이 높았다. 3. 중합시 온도에 따른 비교에서, 1일 경과 후를 제외하고는 모든 시간에서 $43^{\circ}C$에서 중합시킨 군의 중합률이 $28^{\circ}C$에서 중합시킨 군의 중합률 보다 유의성 있게 높았다(p<0.05). 4. 압력은 12시간 경과 후를(p<0.05) 제외하고는 중합률에 영향을 주지 못했다. 5. 보관방법은 1시간 경과 후를(p<0.05) 제외하고는 중합률에 영향을 주지 못했다.

  • PDF

Preparation of New Polyenaminonitriles Containing Cyclic and Methylene Units and Their Thermal Properties

  • Cho, Jeong-Hyun;Gong, Myoung-Seon
    • Macromolecular Research
    • /
    • 제8권5호
    • /
    • pp.209-214
    • /
    • 2000
  • Polyenaminonitriles containing cycloaliphatic and aliphatic units were prepared by interfacial or solution polymerization reaction of p-bis(1-chloro-2,2-dicyanovinyl) benzene (1) with 4-aminobenzyl-amine, 1-(2-aminoethyl)piperazine, 2-(aminomethyl)pyrrolidine and 4-(aminomethyl)piperidine. The chemical structure of the polymers was confirmed through a syntheses of the model compound. The resulting polymers possessed inherent viscosities of 0.29∼0.62 dL/g and they were easily soluble in polar aprotic solvents and common organic solvents. Thermal properties of the polymers such as curability and stability were studied by differential scanning calorimetry (DSC), thermogravimetric analysis (TGA) and infrared spectroscopy. The polymers exhibited a large exotherm in DSC analyses and underwent a curing reaction around 340-370$\^{C}$ to form insoluble materials. The polymers showed 70-80% residual weight at 600 $\^{C}$ under nitrogen.

  • PDF

Photocure Reactions of Photoreactive Prepolymers with Cinnamate Groups

  • Kim, Whan-Gun
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권3호
    • /
    • pp.993-999
    • /
    • 2011
  • The photoreactive prepolymers with multifunctional cinnamate and bisphenol Atype cinnamate groups that could perform photodimerization without photoinitiators were synthesized by the reaction of t-cinnamic acids (CAs) and epoxy resins. Their photocure reaction rates and the extent of reaction conversion were measured with Fourier transform infrared spectroscopy, and these increased with the intensity of UVirradiation. The experimental data of these reaction rates showed the characteristics of nth-order kinetics reaction, and all kinetic constants of each photoreactive polymer with this equation were summarized. Although the GTR-1800-HCA and KWG1-EP-HCA with hydroxyl group substituted cinnamate showed lower reaction conversion rates and rate constant than GTR-1800-CA and KWG1-EP-CAwith an unsubstituted cinnamate group, GTR-1800-MCAand KWG1-EP-MCAwith methoxy group substituted cinnamate showed similar and higher reaction conversion rates than the former, respectively. These results were explained in terms of segmental mobility for photopolymerization by molecular interactions.

요통치료에서 보법의 영향 (The Influence of Walking on Low Back Pain)

  • 박서희;장상철;나삼식;안훈모
    • 대한의료기공학회지
    • /
    • 제14권1호
    • /
    • pp.63-82
    • /
    • 2014
  • This study is aimed to verify effects of Walking in treating hospitalized patients with low back pain in the Korean medicine hospital. The method of this study is choosing patients whose chief complaints were low back pain in the Korean medicine hospital in Gyeonggi Province. People who agreed to take Walking treatment were classified into experimental group and control group. Both experimental group and control group were treated with Korean medicine. In addition, experimental group performed Walking program more often. Changes of temperature difference taken by digital infrared thermal imaging(DITI) were used as measuring tools. The summary of this study's result is as in the following. There was significant difference in the experimental group which performed Walking treatments but not in the control group resulting from examining the change of temperature difference between left and right Yongchon. As known from the results above, Walking program is meaningful in curing the low back pain.

Sawdust reinforced polybenzoxazine composites: Thermal and structural properties

  • Garigipati, Ravi Krishna Swami;Malkapuram, Ramakrishna
    • Advances in materials Research
    • /
    • 제9권4호
    • /
    • pp.311-321
    • /
    • 2020
  • In this study, Mangifera Indica tree sawdust reinforced bisphenol-A aniline based benzoxazine composites were prepared by varying the sawdust from 20 wt% to 45 wt%. Thermogravimetric analysis of composites revealed excellent compatibility between polybenzoxazine and sawdust from the remarkable growth in char yield from 22% (neat resin) to 36% (for highly filled) and glass transition temperature from 151 to 165℃. Ultimate weight loss of the composites evaluated from the Derivatives of TG plots. Limiting oxygen index values of the composites reported considerable growth i.e.,from 28 to 32 along with the increase in filler content. Differential scanning calorimetry results showed that sawdust particles have an insignificant effect on curing temperature (219℃) for the raise in sawdust content. Structure of the sawdust, benzoxazine monomer, polybenzoxazine and composites were studied using Fourier transformation infrared spectroscopy. Overall, polybenzoxazine composites with sawdust as filler showed improved thermal properties when compared with pure polybenzoxazine.

도재인레이 하방에서 광중합형 복합레진과 이중중합형 복합레진시멘트의 미세경도와 중합률에 관한 연구 (THE MICROHARDNESS AND THE DEGREE OF CONVERSION OF LIGHT CURED COMPOSITE RESIN AND DUAL CURED RESIN CEMENTS UNDER PORCELAIN INLAY)

  • 김승수;조성식;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제25권1호
    • /
    • pp.17-40
    • /
    • 2000
  • Resin cements are used for cementing indirect esthetic restorations such as resin or porcelain inlays. Because of its limitations in curing of purely light cured resin cements due to attenuation of the curing light by intervening materials, dual cured resin cements are recommended for cementing restorations. The physical properties of resin cements are greatly influenced by the extent to which a resin cures and the degree of cure is an important factor in the success of the inlay. The purpose of this study was to evaluate the influence of porcelain thickness and exposure time on the polymerization of resin cements by measuring the microhardness and the degree of conversion, to investigate the nature of the correlation between two methods mentioned above, and to determine the exposure time needed to harden resin cements through various thickness of porcelain. The degree of resin cure was evaluated by the measurements of microhardness [Vickers Hardness Number(VHN)] and degree of conversion(DC), as determined by Fourier Transform Infrared Spectroscopy(FTIR) on one light cured composite resin [Z-100(Z)] and three dual cured resin cements [Duo cement(D), 3M Resin cement(R), and Dual cement(DA)] which were cured under porcelain discs thickness of 0mm, 1mm, 2mm, 3mm with light exposure time of 40sec, 80sec, 120sec, and regression analysis was performed to determine the correlation between VHN and DC. In addition, to determine the exposure time needed to harden resin cements under various thickness of porcelain discs, the changes of the intensity of light attenuated by 1mm, 2mm, and 3mm thickness of porcelain discs were measured using the curing radiometer. The results were obtained as follows ; 1. The values of microhardness and the degree of conversion of resin cements without intervening porcelain discs were 31~109VHN and 51~63%, respectively. In the microhardness Z was the highest, followed by R, D, DA. In the degree of conversion, D and DA was significantly greater than Z and R(p<0.05). 2. The microhardness and the degree of conversion of the resin cements decreased with increasing thickness of porcelain discs, and increased with increasing exposure time, D and R showed great variation with inlay thickness and exposure time, whereas, DA showed a little variation. 3. The intensity of light through 1mm, 2mm, and 3mm porcelain inlays decreased by 0.43, 0.25, and 0.14 times compared to direct illumination, and the respective needed exposure times are 53 sec, 70 sec, and 93 sec. In D and R, 40 sec of light irradiation through 2mm porcelain disc and 80 sec of light irradiation through 3mm porcelain disc were not enough to complete curing. 4. The microhardness and the degree of conversion of the resin cements showed a positive correlationship(R=0.791~0.965) in the order of R, D, Z, DA. As the thickness of porcelain discs increased, the decreasing pattern of microhardness was different from that of the degree of conversion, however.

  • PDF