• 제목/요약/키워드: Infrared camera

검색결과 712건 처리시간 0.024초

적외선 방사 카메라를 이용한 PMMA 트래킹 열화에 관한 연구 (A Study on the Tracking Aging of PMMA using Infrared Radiation Camera)

  • 이학현;임장섭;소순열;이진
    • 한국전기전자재료학회논문지
    • /
    • 제20권2호
    • /
    • pp.188-193
    • /
    • 2007
  • Tracking and erosion of Poly Methyl Methacrylate (PMMA) and the suppression mechanism of alumina trihydrate were investigated in the present study The conventional testing as IEC-60587 is widely used in surface aging measurement of outdoor insulator those testing can carry out very short time for Lab testing. Also IEC-60587 testing is able to offer the standard judgement of relative degradation level of outdoor HV system. Therefore it is very useful method compare to previous conventional tracking testing method, But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IRR-Camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis. In this paper, SD occurred from IEC-60587 is measured with the surface temperature of weibull distribution in real time, the degradation grade of SD is analyzed through produced patterns in IEC-60587 using Infrared Radiation(IRR) camera.

적외선 온도 카메라를 이용한 분할형 전기히터 가열 및 유동 조건에 따른 전기히터와 매연필터 표면에서의 온도 분포에 관한 연구 (A Study on the Temperature Distribution at the Surface of Diesel Particulate Filter and Partitioned Electric Heater according to the Conditions of Heating and Flow using an Infrared Temperature Camera)

  • 이충근;박성천
    • 한국안전학회지
    • /
    • 제23권5호
    • /
    • pp.7-14
    • /
    • 2008
  • The temperature distribution in a surface of diesel particulate filter(DPF) was measured using an infrared temperature camera. In order to regenerate the DPF, five partitioned electric heaters were used for heating the ceramic filter. The five partitioned heaters were switched on/off with some time interval one the other. The surface temperature distribution in the ceramic filter and electric heaters were measured with varying both the electrical power supply to the heaters and the mass flow rate of the air supply from a blower. The higher mass flow rate in the DPF system enhanced the uniformity in the surface temperature distribution of the ceramic filter due to effective convection heat transfer. The flow in the monolith ceramic structure of the DPF move mainly in the axial direction, which could be identified from the surface temperature of the ceramic filter.

곡물선별기의 선별력 향상을 위한 근거리적외선 영상보드 개발 (Development of Near Infrared Radiation Image Board for Performace Improvement of Grain Sorter)

  • 이채욱
    • 융합신호처리학회논문지
    • /
    • 제18권1호
    • /
    • pp.25-30
    • /
    • 2017
  • 현재 곡물선별기는 대부분 CCD 광학카메라를 이용하여 불량품을 찾아내고 있다. 본 논문에서는 CCD 카메라를 이용함과 동시에 근거리적외선 센서의 수분측정 방법을 추가하여 곡물선별기의 선별력향상을 목표로 한다. 그리고 구현한 알고리즘을 곡물선별기에 실제로 적용할 수 있도록 근거리적외선 영상보드 시스템을 개발하여, 원료의 내부 수분 함량을 고속으로 체크하여 일정함량 미달인 경우 불량으로 간주하여, 불량품을 실시간으로 제거하는 곡물선별기 시스템을 개발하고자 한다.

  • PDF

열화상 카메라를 이용한 검도 동작의 온도 특성 분석 기초 연구 (A Basic Study on Temperature Characteristic Analysis of Kumdo Motion by Infrared Rays Camera)

  • 이규선;남중웅;석강훈;김정배
    • 융복합기술연구소 논문집
    • /
    • 제2권1호
    • /
    • pp.18-23
    • /
    • 2012
  • The purpose of this study is to visually confirm on variation of temperature changes according to the basic of Kumdo by using infrared rays camera and to obtain the difference of temperature distribution according to the warm up procedure. We selected randomly two Kumdo players, and recorded twice continuously their actions of three basic(Head Hitting, Wrist Hitting, Waist Hitting) motions of Kumdo. In other to obtain the effect of warm up procedure, we recorded again their actions including warm-up motions. Four measuring points on the body were selected in each motion considering the error on continuous recoding. Temperature distributions of the before and after warming up procedure were analyzed at two measuring point. Skin temperature distributions of the players's body in two cases are shown a similar tendency. It can be predicted that the parts of large physical movement result in the large changes of temperature according to the warm up motion.

  • PDF

열화상 카메라를 이용한 택견 동작의 온도 특성 분석 기초 연구 (A Basic Study on Temperature Characteristic Analysis of Taekgyeon Motion by Infrared Rays Camera)

  • 이규선;남중웅;석강훈;김정배
    • 융복합기술연구소 논문집
    • /
    • 제2권1호
    • /
    • pp.31-37
    • /
    • 2012
  • The purpose of this study is to visually confirm on variation of temperature changes according to the basic of Taekgyoen by using infrared rays camera and to obtain difference of temperature distribution according to the warm up procedure. We selected randomly two Taekgyeon players, and recorded twice continuously their actions of three basic motions of Taekgyeon. In other to obtain effect of warm up procedure, we recorded again their actions including warm-up motions. Four measuring points on the body were selected in each motion considering the error on continuous recoding. Temperature distributions of the before and after warming up procedure were analyzed at two measuring point. Temperature distributions of skin of players body in two cases are shown a similar tendency. It can be predicted that the parts of large physical movement result in the large changes of temperature according to the warm up motion.

  • PDF

비디오투시연하검사 스크리닝을 위한 근적외선 기술 조사 (Investigation of Near Infrared Radiation Based Screening for Video-Fluoroscopy Swallowing Studies)

  • 박지수;정영진
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권1호
    • /
    • pp.9-14
    • /
    • 2021
  • With the recent advances in radiological science, there was radiographic techniques development and several researches to diagnosing dysphagia. We proposed the new Imaging technology based on Near Infrared radiation (NIR) for video fluoroscopic swallowing study (VFSS). To reduce the risk of the VFSS examination for swallowing rehabilitation, multi-NIR camera system comprised. Based on the multi-NIR camera imaging system, Computational simulation was conducted to identify the potential of the multi-NIR camera imaging system as a clinical tool (screening system). As a result of the simulation applied in this study, the proposed system has a potential to be a clinical solution although there is a few of limitations. we believe that it will be a good tool to support the VFSS as a screening technology in clinical fields.

적외선 탐지소자의 내방사선화 연구 (A Study on Radiation Hardening of a Infrared Detector)

  • 이남호;김승호;김영호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권11호
    • /
    • pp.490-492
    • /
    • 2005
  • A study on radiation hardening of infrared(IR) detector, the chief component of IR camera was performed. The radiation test on IR sensor passivated with the ZnS by Co$^{60}$ gamma-ray over 1 Mrads showed the reduction in Ro by 1/100 which was related to the noise level. This effect that was caused by carrier trapping in the ZnS passivation layer increased the leakage current and resulted in degradation in the device performance. For the radiation hardening of IR devices we suggested the ones with CdTe passivation layer which had a tendency to reluctant to carrier trapping in its layer and developed test patterns. Radiation test to the patterns showed that the our CdTe passivated device could survived over 1 Mrad gamma-ray dose.

Infrared LED-Based Arcade Gun System for Wide Screen

  • Choi, YoSeph;Kang, DuCheol;Yun, TaeSoo
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제3권5호
    • /
    • pp.306-312
    • /
    • 2014
  • The arcade gun has been a popular game controller in the video game market from the 1970s. The arcade gun, which is used partially in game centers and domestic games, recently is utilized as the interface for the interactive system and tangible media. On the other hand, the existing arcade gun has limits on hardware so it is unsuitable for wide screens. In addition, being platform-dependent, it is inapplicable to various types of content as a single module. This study suggests a correction algorithm that establishes an arcade gun system based on an infrared camera to solve those drawbacks and apply to possibly numerous surroundings.

Temperature Measurement of Photovoltaic Modules Using Non-Contact Infrared System

  • Jovanovic, Ugljesa;Mancic, Dragan;Jovanovic, Igor;Petrusic, Zoran
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.904-910
    • /
    • 2017
  • This paper presents temperature measurement of solar photovoltaic modules using the custom-made system composed of an infrared temperature sensor and a microcontroller. The obtained measurement results are processed, displayed and stored on a PC using the custom-made virtual instrument. The proposed system overcomes some of the problems related to the contact sensor application, and at the same time offers accurate readings and better flexibility. The proposed system is especially suitable for applications where the cost is a limiting factor in the choice of measuring system. The conducted analysis and the obtained results have shown an excellent accuracy of the proposed system in comparison to a high quality thermal imaging camera used as the reference instrument.

CURRENT STATUS OF THE INSTRUMENTS, INSTRUMENTATION AND OPEN USE OF OKAYAMA ASTROPHYSICAL OBSERVATORY

  • YOSHIDA MICHITOSHI
    • 천문학회지
    • /
    • 제38권2호
    • /
    • pp.117-120
    • /
    • 2005
  • Current instrumentation activities and the open user status of Okayama Astrophysical Observatory (OAO) are reviewed. There are two telescopes in operation and one telescope under reforming at OAO. The 188cm telescope is provided for open use for more than 200 nights in a year. The typical over-subscription rate of observation proposals for the 188cm telescope is ${\~}$ 1.5 - 2. The 50cm telescope is dedicated to $\gamma$-ray burst optical follow-up observation and is operated in collaboration with Tokyo Institute of Technology. The 91cm telescope will become a new very wide field near-infrared camera in two years. The high-dispersion echelle spectrograph (HIDES) is the current primary instrument for the open use of the 188cm telescope. Two new instruments, an infrared multi-purpose camera (ISLE) and an optical low-dispersion spectrograph (KOOLS), are now under development. They will be open as common use instruments in 2006.