• Title/Summary/Keyword: Infrared analysis system

검색결과 432건 처리시간 0.023초

적외선 열화상 카메라를 이용한 용접 비드의 열 해석 (Heat Analysis of Welding-bead using Infrared Thermoimage Camera)

  • 김재열;심재기;양동조;유신
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2000년도 추계학술대회논문집 - 한국공작기계학회
    • /
    • pp.57-62
    • /
    • 2000
  • Diagnosis or measurements using Infrared thermoimage hasn't been available. A quick diagnosis and thermal analysis can be possible when that kind of system is introduced to the investigation of each part. In this study, Infrared Camera, Thermovision 900 was used in order to investigate. Infrared Camera usually detects only Infrared wave from the light in order to illustrate the temperature distribution. Infrared diagnosis system can be applied to various field. Also, it is more effective to analyze temperature distribution on the welding parts during welding process. Especially, diagnosis using Infrared camera plays an important role on thermal analysis of Axle Casing Nut for Commercial Vehicles.

  • PDF

적외선 열화상 카메라를 이용한 수전설비 온도분포해석 (The Analysis of Temperature Distribution Electric incoming Apparatus Using a Infrared Thermal Imaging System)

  • 정승천;임용배
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1113-1116
    • /
    • 2004
  • This paper presents the method for analyzing surface temperature of Electric incoming Apparatus. For the experiment, the surface temperature of electric power apparatus was measured and analyzed by using a infrared thermal imaging system. Surface Discharges(SD) have very complex characteristics of discharge patterns, therefore it requires the development of precise analysis methods. recently, studies on infrared thermal imaging system are carried out to analyze temperature distribution of power equipments through condition diagnosis and to diagnose the degradation of power equipments. The changes in suface temperature was measured by using the infrared thermal imaging system under hot line condition. The system was set up based on the diagnostic method of the electric incoming apparatus.

  • PDF

적외선 검출기 개발가능성 및 대안 분석 연구 (A Study on Feasibility Analysis and Alternatives for Infrared Detector Development)

  • 김경수;민성기;김철환
    • 시스템엔지니어링워크숍
    • /
    • 통권4호
    • /
    • pp.123-134
    • /
    • 2004
  • This paper deals with the feasibility analysis and alternatives for infrared detector development. The purpose of this paper analyze development requirement and feasibility study in both technology and cost. We get raw input data for system engineering process from development and technical expert, and then analyze cost and technology for development feasibility, and alternative study. Infrared Detector is core component of Thermal Imaging System and developed by ADD from 2006 to 2008 year. Technical level is analyzed by TRL(Technical Readiness Level) and AOA(Analysis of Alternative) is done by development and production cost estimate. We use SEER-H tool for cost estimate, that is parametric cost estimate tool based on Knowledge Base. Also this paper presents risk analysis for project management because it is necessary to risk driver management during the infrared detector development. The result of IR Detector feasibility and alternative study will be used in technical and cost analysis. This study can help those who are related to the cost analysis and development feasibility of other weapons

  • PDF

적외선 열화상 카메라를 이용한 머시닝 센터 주축 열변위에 관한 열해석 (Thermo-Analysis of Machining Center Main-Axis Thermo-Displacement for Infrared Rays Thermo-Image Camera)

  • 김재열;윤성운;임노빈;유신;마상동;양동조;송인석
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2001년도 춘계학술대회 논문집(한국공작기계학회)
    • /
    • pp.125-130
    • /
    • 2001
  • Diagnosis or measurements using Infrared thermo-image hasn t been available. A quick diagnosis and thermal analysis can be possible when that kind of system is introduced to the investigation of each part. In this study, Infrared Camera, Thermo-vision 900 was used in order to investigate. Infrared Camera usually detects only Infrared wave from the light in order to illustrate the temperature distribution. Infrared diagnosis system can be applied to various field. Also, it is more effective to analyze temperature distribution on the machining center main-axis process.

  • PDF

적외선 영상해석을 이용한 이중목적탄 자탄계수 계측기법연구 (DPICM subprojectile counting technique using image analysis of infrared camera)

  • 박원우;최주호;유준
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.11-16
    • /
    • 1997
  • This paper describes the grenade counting system developed for DPICM submunition analysis using the infrared video streams, and its some video stream processing technique. The video stream data processing procedure consists of four sequences; Analog infrared video stream recording, video stream capture, video stream pre-processing, and video stream analysis including the grenade counting. Some applications of this algorithms to real bursting test has shown the possibility of automation for submunition counting.

  • PDF

근적외분광분석법을 이용한 인도메타신의 정량분석 (Quantitative Analysis of Indomethacin by the Portable Near-Infrared (NIR) System)

  • 김도형;우영아;김효진
    • 약학회지
    • /
    • 제47권5호
    • /
    • pp.261-265
    • /
    • 2003
  • Near-infrared (NIR) system was used to determine rapidly and simply indomethacin in buffer solution for a dissolution test of tablets and capsules. Indomethacin standards were prepared ranging from 10 to 50 ppm using the mixture of phosphate buffer (pH 7.2) and water (1 : 4). The near-infrared (NIR) transmittance spectra of indomethacin standard solutions were collected by using a quartz cell in 1 mm and 2 mm pathlength. Partial least square regression (PLSR) was explored to develop calibration models over the spectral range 1100∼1700 nm. The model using 1 mm quartz cell was better than that using 2 mm quartz cell. The PLSR models developed gave standard error of prediction (SEP) of 0.858 ppm. In order to validate the developed calibration model, routine analysis was performed using another standard solutions. The NIR routine analysis showed good correlation with actual values. Standard error of prediction (SEP) is 1.414 ppm for 7 indomethacin samples in routine analysis and its error was permeable in the regulation of Korean Pharmacopoeia (VII). These results show the potential use of the real time monitoring for indomethacin during a dissolution test.

원적외선 온열이 인체 자율신경기능에 미치는 영향에 관한 연구 (A Study on Human Autonomic Nervous System Activities by Far-Infrared Ray Hyperthermia)

  • 박찬욱;장윤호;민세동;강세구;이충근;이명호
    • 대한의용생체공학회:의공학회지
    • /
    • 제25권6호
    • /
    • pp.623-628
    • /
    • 2004
  • 본 논문에서는 원적외선 온열효과가 자율 신경계에 미치는 영향을 심박변동(HRV)을 이용하여 평가 하였다. 측정된 심박변동신호를 FFT 의한 전력스펙트럼을 구함으로써 자율 신경계의 반응 특성을 고찰하고 Poincare plot 분석 방법을 이용하여 결과를 비교 분석하였다. 실험을 통해 심박변동 신호분석해보면 원적외선 온열에 노출되기 전에 비해 노출된 후에 매우 복잡한 모습임을 관찰 할 수 있었는데 이것은 자율신경계가 관여하는 심혈관계 제어 메커니즘이 원적외선 온열에 노출되기 전보다 노출된 후에 더욱 복잡함을 반영하는 것으로 분석된다.

NEW DEVELOPED PORTABLE NEAR INFRARED (NIR) SYSTEM USING MICROSPECTROMETER

  • Woo, Young-Ah;Ha, Tae-Kyu;Kim, Jae-Min;Kim, Hyo-Jin
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1123-1123
    • /
    • 2001
  • In recent years, a miniature spectrometer has been extensively developed due to the marriage of fiber optics and semiconductor detector array. This type of miniature spectrometer has advantages of low price and robustness due to the capability of mass production and no moving parts are required such as lenses, mirrors and scanning monochromator. These systems are ideal for use in teaching labs, process monitoring and field analyses. A portable near infrared (NIR) system has been developed for qualitative and quantitative analysis. This system includes a tungsten halogen lamp for light source, a fiber optics connected a light source, and a sample module to the microspectrometer, The size of spectrometer can be as small as 2.5 cm x 1.5 cm x 0.1 cm. Wavelength ranges can be chosen as 360-800 nm, 800-1100 nm and 1100-1900 nm depending on the type of detector. The software consists of various tools for multivariate analysis and pattern recognition techniques. To evaluate the system, long and short-term stability, wavelength accuracy, and stray light have been investigated and compared with conventional scanning type NIR spectrometer. This developed system can be sufficiently used for quantitative and qualitative analysis for various samples such as agricultural product, herbal medicine, food, petroleum, and pharmaceuticals, etc.

  • PDF

열화상 영상을 이용한 래들의 내화물 열화도 분석 (Analyzing Refractory Bricks of Ladles using Infrared Images)

  • 이상준;전용주;김상우
    • 제어로봇시스템학회논문지
    • /
    • 제21권4호
    • /
    • pp.291-300
    • /
    • 2015
  • In the steel manufacturing process heat-endurance deterioration of a ladle used to cause a big accident. In this paper, an infrared imaging system and image analyzing procedure are proposed for inspecting refractory bricks of a ladle. The proposed algorithm contains following three parts: two-stage image selection procedure, reference point detection, and analysis of heat-endurance deterioration. Experiments were conducted with real data from a steel plant and detailed configuration of infrared imaging system was presented.

850 nm 파장대 근적외선과 갈바닉 전류기반의 눈가 주름 치료기 개발 및 영상 분석을 통한 치료성능 검증 (Design of 850 nm Near Infrared and Galvanic Current Based Eyeglass-Type Device for Periorbital Wrinkle Treatment and Verification of Treatment Performance through Image Analysis)

  • 안성수;권기진
    • 한국멀티미디어학회논문지
    • /
    • 제21권12호
    • /
    • pp.1379-1386
    • /
    • 2018
  • In this paper, we proposed eyeglass type periorbital wrinkle treatment device for reducing and improving periorbital wrinkles using near infrared LED of 850nm wavelength and galvanic current. The proposed periorbital wrinkle treatment device is equipped with a control system based on F-PCB. It consists of eight near-infrared LEDs and four indicator LEDs for treatment of right and left periorbital wrinkles. The eyeglass frame is coated with conductive material, so galvanic current can flow to the skin of periorbital wrinkle contacted to it. One male adult in the mid-40s was allowed to use the device for 10 minutes every day for 4 weeks. After 4 weeks, image analysis using optical equipment for measuring wrinkles indicated that wrinkle indexes were reduced.