• Title/Summary/Keyword: Infrared Temperature Mapping

Search Result 16, Processing Time 0.024 seconds

Image Processing using Thermal Infrared Image (열적외선 이미지를 이용한 영상 처리)

  • Jeong, Byoung-Jo;Jang, Sung-Whan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.7
    • /
    • pp.1503-1508
    • /
    • 2009
  • This study applied image processing techniques, constructed to real-time, to thermal infrared camera image. Thermal infrared image data was utilized for hot mapping, cool mapping, and rainbow mapping according to changing temperature. It was histogram image processing techniques so that detected shade contrast function of the thermal infrared image, and the thermal infrared image's edge was extracted to classification of object. Moreover, extraction of temperature from image was measured by using the image information program.

Measurements of Film Thickness and Temperature Distribution in Dimple Zone Developed in EHL Point Contact at High Slip Ratios (높은 미끄럼 비의 점 접촉 EHL 하에서 발생하는 딤플 영역의 온도 분포와 유막 두께 분포의 측정)

  • Kim, Sung-Gi;Kazuyuki Yagi;Tsunamitsu Nakahara;Keizi Kyougoku;Kim, Kyung-Woong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.4
    • /
    • pp.479-484
    • /
    • 2003
  • In this paper, film thickness and temperature distribution are measured in EHL point contact at high slip ratios. Infrared temperature mapping with two band pass fillers. proposed by Ausherman (1976). is used to measure temperature distribution. And the optical interferornetric method with two filters (red and green filters) is used to measure film thickness. Result of experiment showed that temperature rising at film and ball surface occurred very dramatically in Dimple zone. As slip velocity, slip ratio and load increased, size of Dimple and temperature rising became more large In addition, Position and shape of Dimple we changed by slip ratios, and increasing of Dimple size decreased traction coefficient. In short, it is appointed that the Dimple phenomenon be developed by the effect of viscosity wedge.

Measurements of film thickness and temperature distribution in EHL point contact at high roll/slip ratios (높은 구름/미끄럼 비를 갖는 점 접촉 EHL 하에서의 온도분포와 유막 두께 분포의 측정)

  • Kim, Sung-Gi;Yagi, Kazuyuki;Nakahara, Tsunamitsu;Kyougoku, Keizi;Kim, Kyung-Woong
    • Proceedings of the KSME Conference
    • /
    • 2001.06c
    • /
    • pp.293-298
    • /
    • 2001
  • In this paper, film thickness and temperature distribution are measured in EHL point contact at high roll/slip ratios. Infrared temperature mapping with two band pass filters, proposed by Ausherman (1976), is used to measure temperature distribution. And the optical interferometric method with two filters (red and green filters) is used to measure film thickness. Result of experiment showed that temperature rising at film and ball surface occurred very dramatically in Dimple zone. As slip velocity, roll/slip ratio and load increased, size of Dimple and temperature rising became more large. In addition, position and shape of Dimple were changed by roll/slip ratios, and increasing of Dimple size decreased traction coefficient. In short, it is appointed that the Dimple phenomenon be developed by the effect of viscosity wedge.

  • PDF

A Study of a Heat Flux Mapping Procedure to Overcome the Limitation of Heat Flux Gauges in Fire Tests (화재실험시 열유속 센서 사용의 단점을 보완한 Heat Flux Mapping Procedure에 관한 연구)

  • Choi, Keum-Ran
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.4 s.72
    • /
    • pp.171-179
    • /
    • 2005
  • It is essential to understand the role of wall lining materials when they are exposed to a fire from an ignition source. Full-scale test methods permit an assessment of the performance of a wall lining material. Fire growth models have been developed due to the costly expense associated with full-scale testing. The models require heat flux maps from the ignition burner flame as input data. Work to date was impeded by a lack of detailed spatial characterization of the heat flux maps due to the use of limited instrumentation. To increase the power of fire modeling, accurate and detailed heat flux maps from the ignition burner are essential. High level spatial resolution for surface temperature can be provided from an infrared camera. The objective of this study was to develop a heat flux mapping procedure for a room test burner flame to a wall configuration with surface temperature information taken from an infrared camera. A prototype experiment was performed using the ISO 9705 test burner to demonstrate the developed heat flux mapping procedure. The results of the experiment allow the heat flux and spatial resolutions of the method to be determined and compared to the methods currently available.

The Detection of Yellow Sand with Satellite Infrared bands

  • Ha, Jong-Sung;Kim, Jae-Hwan;Lee, Hyun-Jin
    • Korean Journal of Remote Sensing
    • /
    • v.22 no.5
    • /
    • pp.403-406
    • /
    • 2006
  • An algorithm for detection of yellow sand aerosols has been developed with infrared bands. This algorithm is a hybrid algorithm that has used two methods combined. The first method used the differential absorption in brightness temperature difference between $11{\mu}m\;and\;12{\mu}m\;(BTD1)$. The radiation at $11{\mu}m$ is absorbed more than at $12{\mu}m$ when yellow sand is loaded in the atmosphere, whereas it will be the other way around when cloud is present. The second method uses the brightness temperature difference between $3.7{\mu}m\;and\;11{\mu}m(BTD2)$. This technique is sensitive to dust loading, which the BTD2 is enhanced by reflection of $3.7{\mu}m$ solar radiation. First the Principle Component Analysis (PCA), a form of eigenvector statistical analysis from the two methods, is performed and the aerosol pixel with the lowest 10% of the eigenvalue is eliminated. Then the aerosol index (AI) from the combination of BTD 1 and 2 is derived. We applied this method to Multi-functional Transport Satellite-l Replacement (MTSAT-1R) data and obtained that the derived AI showed remarkably good agreements with Ozone Mapping Instrument (OMI) AI and Moderate Resolution Imaging Spectroradiometer (MODIS) aerosol optical depth.

Infrared Imaging and a New Interpretation on the Reverse Contrast Images in GaAs Wafer (GaAs 웨이퍼의 적외선 영상기법 및 콘트라스트 반전 영상에 대한 새로운 해석)

  • Kang, Seong-jun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.11
    • /
    • pp.2085-2092
    • /
    • 2016
  • One of the most important properties of the IC substrate is that it should be uniform over large areas. Among the various physical approaches of wafer defect characterization, special attention is to be payed to the infrared techniques of inspection. In particular, a high spatial resolution, near infrared absorption method has been adopted to directly observe defects in semi-insulating GaAs. This technique, which relies on the mapping of infrared transmission, is both rapid and non-destructive. This method demonstrates in a direct way that the infrared images of GaAs crystals arise from defect absorption process. A new interpretation is presented for the observed reversal of contrast in the infrared absorption of nonuniformly distributed deep centers, related to EL2, in semi-insulating GaAs. The low temperature photoquenching experiment has demonstrated in a direct way that the contrast inverse images of GaAs wafers arise from both absorption and scattering mechanisms rather than charge re-distribution or local variation of bandgap.

An Investigation on the Surface Flow Characteristics of Ogive-cylinder using the Infrared Ray Thermogram 3D Mapping Technique (적외선 온도 측정 3차원 매핑 기법을 이용한 오자이브 실린더 표면 유동 특성 파악)

  • LEE, Jaeho
    • Journal of Aerospace System Engineering
    • /
    • v.12 no.4
    • /
    • pp.57-63
    • /
    • 2018
  • IR thermography is a non-invasive method and used for the visualization of the surface temperature of the model. However, this technique only derives 2D results and not quantitative data. The goal of this study is to apply the 3D mapping technique for IR thermography. The wind tunnel model is an ogive-cylinder with a wind speed of 20 m/s ~ 80 m/s and the angle of attack ranging from $0^{\circ}$ to $90^{\circ}$. The real location of the model was made to correspond with the position of the IR image using the makers. Based on this result, quantitative results were obtained. The 3D mapping method was verified by comparing the separation point and the theoretical value.

Predicting lipoabdominoplasty complications with infrared thermography: a delta-R analysis

  • Resende, Patricia Rodrigues;Brioschi, Marcos Leal;Meneck, Franciele De;Neves, Eduardo Borba;Teixeira, Manoel Jacobsen
    • Archives of Plastic Surgery
    • /
    • v.48 no.5
    • /
    • pp.553-558
    • /
    • 2021
  • The diagnosis of the main complications resulting from lipoabdominoplasty has not yet been standardized. Infrared thermal imaging has been used to assess possible complications, such as necrosis and changes in micro- and macro-circulation, based on perforator mapping techniques, among others. The objective of this study was to present two clinical cases involving thermal imaging monitoring of the healing process of lipoabdominoplasty in the immediate postoperative evaluation and its preliminary results. Infrared thermography was performed 24 hours after the operation and on postoperative days 5, 25, and 27. In clinical case 1, it was found that the delta-R (∆TR)-defined as the difference in minimum temperature between the highest and lowest points in the SA3 region (caution suction area) following the classification established by Matarasso-was 0.4℃ at 24 hours after surgery and decreased to 0.1℃ on a postoperative day 5. There were no complications in this case. In contrast, in clinical case 2, the ∆TR was 1.7℃ at 24 hours after surgery (upon hospital discharge) and remained high, at 2.2℃, on postoperative day 5. A higher ∆TR was found in the second patient, who developed necrosis of the surgical wound. The ∆TR thermal index may be a new tool for predicting possible complications, complementing the clinical evaluation and therapeutic decision-making.

A SEARCH FOR MOLECULAR CLOUDS AT HIGH GALACTIC LATITUDE

  • Chi Seung-Youp;Park Yong-Sun
    • Journal of The Korean Astronomical Society
    • /
    • v.39 no.1
    • /
    • pp.19-24
    • /
    • 2006
  • We carried out CO survey toward IR-excess clouds using SRAO 6-m telescope in search of molecular $H_2$. These clouds, which show far-infrared excess over what is expected from HI column density, are considered to be candidates of molecular clouds. In order to find new high Galactic latitude clouds, we made mapping observations for 14 IR-excess clouds selected from Reach et al.(1998) in $^{12}CO$ J = 1 - 0 line, supplementing the similar survey in southern hemisphere (Onishi et al. 2001). $^{12}CO$ emission is detected from three IR-excess clouds among 14 objects. Three newly detected clouds exhibit somewhat clumpy morphology and column densities amount to ${\sim}10^{21}\;cm^{-2}$. One of three clouds, DIR120-28, show discrepancy between IR-excess center and CO emission center. It seems that IR-excess may not be an effective tracer of molecular gas. Instead, optical depth$(\tau)$ excess, i.e., IR-excess corrected for temperature dependence, may be more effective tracer of molecular clouds, since, by combining statistics from both hemispheres, we found that the detection rate is higher for IR-excess clouds with lower dust temperature.

Conservation State of Mural Paintings of Royal Tombs in Neungsan-ri, Korea (능산리고분군 동하총 벽화 보존상태 진단)

  • Lee, Sang Ok;Bae, Go Woon;Namgung, Hun;Nam, Do Hyeon;Choi, Yoon Gwan;Chung, Kwang Yong
    • Journal of Conservation Science
    • /
    • v.34 no.5
    • /
    • pp.333-343
    • /
    • 2018
  • This study was conducted to evaluate the conservation environment by monitoring temperature and humidity for two years and mapping the remaining pigments of mural paintings to diagnose the conservation state of mural paintings of Royal Tombs in Neungsan-ri. We evaluated the characteristics of condensation in the tomb. Compared with the results of a 2008 survey, we conducted state change of mural paintings in the tomb. The temperature in the main room, which has an annual average soil temperature distribution at 5 m depth in Korea, is maintained at $13{\sim}18^{\circ}C$. The temperature range of the main room was between less than $0.1^{\circ}C$ to $0.5^{\circ}C$, and the diurnal variation of temperature between summer (June to September) and winter (December to January) is the greatest. Condensation is more concentrated in the summer because the outdoor air was typically at higher temperatures than the main room inflows in the tomb. Mapping the remaining pigment composition and particle distribution of mural paintings showed that it was in the range of 36.72~39.53% of the wall area. The pigment range was confirmed to be the same as it was in 2008, through ultraviolet fluorescence reaction and infrared ray investigation. Therefore, the underground environment that receives dew condensation in the summer has been stable since 2008. However, continuous monitoring is needed because the deterioration of mural painting proceeds considerably after excavation and only a small percentage of the pigments survive.