• Title/Summary/Keyword: Infrared Optics

Search Result 219, Processing Time 0.04 seconds

Infrared Dual-field-of-view Optical System Design with Electro-Optic/Laser Common-aperture Optics

  • Jeong, Dohwan;Lee, Jun Ho;Jeong, Ho;Ok, Chang Min;Park, Hyun-Woo
    • Current Optics and Photonics
    • /
    • v.2 no.3
    • /
    • pp.241-249
    • /
    • 2018
  • We report a midinfrared dual-field-of-view (FOV) optical system design for an airborne electro-optical targeting system. To achieve miniaturization and weight reduction of the system, it has a common aperture and fore-optics for three different spectral wavelength bands: an electro-optic (EO) band ($0.6{\sim}0.9{\mu}m$), a midinfrared (IR) band ($3.6{\sim}4.9{\mu}m$), and a designation laser wavelength ($1.064{\mu}m$). It is free to steer the line of sight by rotating the pitch and roll axes. Our design co-aligns the roll axis, and the line of sight therefore has a fixed entrance pupil position for all optical paths, unlike previously reported dual-FOV designs, which dispenses with image coregistration that is otherwise required. The fore-optics is essentially an achromatized, collimated beam reducer for all bands. Following the fore-optics, the bands are split into the dual-FOV IR path and the EO/laser path by a beam splitter. The subsequent dual-FOV IR path design consists of a zoom lens group and a relay lens group. The IR path with the fore-optics provides two stepwise FOVs ($1.50^{\circ}{\times}1.20^{\circ}$ to $5.40^{\circ}{\times}4.32^{\circ}$), due to the insertion of two Si lenses into the zoom lens group. The IR optical system is designed in such a way that the location and f-number (f/5.3) of the cold stop internally provided by the IR detector are maintained when changing the zoom. The design also satisfies several important performance requirements, including an on-axis modulation transfer function (MTF) that exceeds 10% at the Nyquist frequency of the IR detector pitch, with distortion of less than 2%.

Reagentless Determination of Human Serum Components Using Infrared Absorption Spectroscopy

  • Hahn, Sang-Joon;Yoon, Gil-Won;Kim Gun-Shik;Park Seung-Han
    • Journal of the Optical Society of Korea
    • /
    • v.7 no.4
    • /
    • pp.240-244
    • /
    • 2003
  • Simultaneous determination of concentrations for four major components in human blood serum was investigated using a Fourier-transform mid-infrared spectroscopy. Infrared spectra of human blood serum were measured in 8.404 ∼ 10.25 ${\mu}m$ range where the highest absorption peaks of glucose are located. A partial least square (PLS) algorithm was utilized to establish a calibration model for determining total protein, albumin, globulin and glucose levels which are commonly measured metabolites. The standard error of cross validation obtained from our multivariate calibration model was 0.24 g/dL for total protein, 0.15 g/dL for albumin, 0.17 g/dL for globulin, and 6.68 mg/dL for glucose, which are comparable with or meet the criteria for clinical use. The results indicate that the infrared absorption spectroscopy can be used to predict the concentrations of clinically important metabolites without going through a chemical process with a reagent.

NEW DEVELOPED PORTABLE NEAR INFRARED (NIR) SYSTEM USING MICROSPECTROMETER

  • Woo, Young-Ah;Ha, Tae-Kyu;Kim, Jae-Min;Kim, Hyo-Jin
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1123-1123
    • /
    • 2001
  • In recent years, a miniature spectrometer has been extensively developed due to the marriage of fiber optics and semiconductor detector array. This type of miniature spectrometer has advantages of low price and robustness due to the capability of mass production and no moving parts are required such as lenses, mirrors and scanning monochromator. These systems are ideal for use in teaching labs, process monitoring and field analyses. A portable near infrared (NIR) system has been developed for qualitative and quantitative analysis. This system includes a tungsten halogen lamp for light source, a fiber optics connected a light source, and a sample module to the microspectrometer, The size of spectrometer can be as small as 2.5 cm x 1.5 cm x 0.1 cm. Wavelength ranges can be chosen as 360-800 nm, 800-1100 nm and 1100-1900 nm depending on the type of detector. The software consists of various tools for multivariate analysis and pattern recognition techniques. To evaluate the system, long and short-term stability, wavelength accuracy, and stray light have been investigated and compared with conventional scanning type NIR spectrometer. This developed system can be sufficiently used for quantitative and qualitative analysis for various samples such as agricultural product, herbal medicine, food, petroleum, and pharmaceuticals, etc.

  • PDF

CHALLENGING APPLICATIONS FOR FT-NIR SPECTROSCOPY

  • Goode, Jon G.;Londhe, Sameer;Dejesus, Steve;Wang, Qian
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.4112-4112
    • /
    • 2001
  • The feasibility of NIR spectroscopy as a quick and nondestructive method for quality control of uniformity of coating thickness of pharmaceutical tablets was investigated. Near infrared spectra of a set of pharmaceutical tablets with varying coating thickness were measured with a diffuse reflectance fiber optic probe connected to a Broker IFS 28/N FT-NIR spectrometer. The challenging issues encountered in this study included: 1. The similarity of the formulation of the core and coating materials, 2. The lack of sufficient calibration samples and 3. The non-linear relationship between the NIR spectral intensity and coating: thickness. A peak at 7184 $cm^{-1}$ was identified that differed for the coating material and the core material when M spectra were collected at 2 $cm^{-1}$ resolution (0.4 nm at 7184 $cm^{-1}$). The study showed that the coating thickness can be analyzed by polynomial fitting of the peak area of the selected peak, while least squares calibration of the same data failed due to the lack of availability of sufficient calibration samples. Samples of coal powder and solid pieces of coal were analyzed by FT-NIR diffuse reflectance spectroscopy with the goal of predicting their ash content, percentage of volatile components, and energy content. The measurements were performed on a Broker Vector 22N spectrometer with a fiber optic probe. A partial least squares model was constructed for each of the parameters of interest for solid and powdered sample forms separately. Calibration models varied in size from 4 to 10 PLS ranks. Correlation coefficients for these models ranged from 86.6 to 95.0%, with root-mean-square errors of cross validation comparable to the corresponding reference measurement methods. The use of FT-NIR diffuse reflectance measurement techniques was found to be a significant improvement over existing measurement methodologies in terms of speed and ease of use, while maintaining the desired accuracy for all parameters and sample forms.(Figure Omitted).

  • PDF

LABORATORY EXPERIMENTS OF OFF-AXIS MIRROR OPTICS OF ALUMINUM FOR SPACE INFRARED MISSIONS

  • Oseki, Shinji;Oyabu, Shinki;Ishihara, Daisuke;Enya, Keigo;Haze, Kanae;Kotani, Takayuki;Kaneda, Hidehiro;Nishiyama, Miho;Abe, Lyu;Yamamuro, Tomoyasu
    • Publications of The Korean Astronomical Society
    • /
    • v.32 no.1
    • /
    • pp.359-361
    • /
    • 2017
  • We report our research on aluminum mirror optics for future infrared astronomical satellites. For space infrared missions, cooling the whole instrument is crucial to suppress the infrared background and detector noise. In this aspect, aluminum is appropriate for cryogenic optics, because the same material can be used for the whole structure of the instrument including optical components thanks to its excellent machinability, which helps to mitigate optical misalignment at low temperatures. We have fabricated aluminum mirrors with ultra-precision machining and measured the wave front errors (WFEs) of the mirrors with a Fizeau interferometer. Based on the power spectral densities of the WFEs, we confirmed that the surface accuracy of all the mirrors satisfied the requirements for the SPICA Coronagraph Instrument. We then integrated the mirrors into an optical system, and examined the image quality of the system with an optical laser. As a result, the total WFE is estimated to be 33 nm (rms) from the Strehl ratio. This is consistent with the WFEs estimated from the measurement of the individual mirrors.

Development of a MTF Measurement System for an Infrared Optical System (적외선 광학계용 MTF 측정장치 개발)

  • Son, Byoung-Ho;Lee, Hoi-Yoon;Song, Jae-Bong;Yang, Ho-Soon;Lee, Yun-Woo
    • Korean Journal of Optics and Photonics
    • /
    • v.26 no.3
    • /
    • pp.162-167
    • /
    • 2015
  • In this paper, we developed a MTF (Modulation Transfer Function) measurement system using a knife-edge scanning method for infrared optics. It consists of an objective part to generate the target image, a collimator to make the beam parallel, and a detector to analyze the image. We used a tungsten filament as the light source and MCT (Mercury Cadmium Telluride) to detect the mid-infrared(wavelength $3-5{\mu}m$) image. We measured the MTF of a standard lens (f=5, material ZnSe) to test this instrument and compared the result to the theoretical value calculated using the ZEMAX commercial software. It was found that the difference was within ${\pm}0.035$ at the cut-off frequency (50 1/mm). Also, we calculated the A-type measurement uncertainty to check the reliability of the measurement. The result showed only 0.002 at 20 1/mm in spatial frequency, which means very little variation in the MTF measurement under the same conditions.

A Compact Top-View Conformal Optical System Based on a Single Rotating Cylindrical Lens with Wide Field of Regard

  • Yu, Linyao;Wei, Qun;Zheng, Jinggao;Ge, Mingda;Zhang, Tianyi
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.1
    • /
    • pp.64-69
    • /
    • 2016
  • A new compact conformal dome optical system was established, and the aberration characteristics of the dome were investigated using Zernike aberration theory. The aberrations induced by the dome at different fields of regard (FORs) from 30° to 100° were effectively balanced by a rotating cylindrical lens. This kind of optical system can be widely used in top-view optical searching devices. A design method was introduced and the optimization results analyzed in detail. The results showed that the Zernike aberrations produced by the conformal dome were decreased dramatically. Also, a complete conformal optical system was designed, to further illustrate the aberration correction effect of the rotating cylindrical lens. Using a cylindrical lens not only provided a large FOR, but also simplified enormously the structure of the conformal optical system.

Development of Inspection System With Optical Scanning Mechanism and Near-Infrared Camera Optics for Solar Cell Wafer (광학스캐닝 메커니즘 및 근적외선 카메라 광학계를 이용한 태양전지 웨이퍼 검사장치 개발)

  • Kim, Gyung Bum
    • Journal of the Semiconductor & Display Technology
    • /
    • v.11 no.3
    • /
    • pp.1-6
    • /
    • 2012
  • In this paper, inspection system based on optical scanning mechanism is designed and developed for solar cell wafer. It consists of optical scanning mechanism, NIR camera optics, machinery and control system, algorithm of defect detection and software. Optical scanning mechanism is composed of geometrical camera optics and structured hybrid illumination system. It is used to inspection of surface defects. NIR camera optics is used for inspection of defects inside solar cell wafer. It is shown that surface and internal micro defects can be detected in developed inspection system for solar cell wafer.

Magnetic Resonance Imaging Meets Fiber Optics: a Brief Investigation of Multimodal Studies on Fiber Optics-Based Diagnostic / Therapeutic Techniques and Magnetic Resonance Imaging

  • Choi, Jong-ryul;Oh, Sung Suk
    • Investigative Magnetic Resonance Imaging
    • /
    • v.25 no.4
    • /
    • pp.218-228
    • /
    • 2021
  • Due to their high degree of freedom to transfer and acquire light, fiber optics can be used in the presence of strong magnetic fields. Hence, optical sensing and imaging based on fiber optics can be integrated with magnetic resonance imaging (MRI) diagnostic systems to acquire valuable information on biological tissues and organs based on a magnetic field. In this article, we explored the combination of MRI and optical sensing/imaging techniques by classifying them into the following topics: 1) functional near-infrared spectroscopy with functional MRI for brain studies and brain disease diagnoses, 2) integration of fiber-optic molecular imaging and optogenetic stimulation with MRI, and 3) optical therapeutic applications with an MRI guidance system. Through these investigations, we believe that a combination of MRI and optical sensing/imaging techniques can be employed as both research methods for multidisciplinary studies and clinical diagnostic/therapeutic devices.