• Title/Summary/Keyword: Infrared: imaging

Search Result 763, Processing Time 0.021 seconds

Design of a Light and Small Dual-band Airborne Despun Optical System

  • Luqing Zhang;Ning Zhang;Xiping Xu;Kailin Zhang;Yue Zhang;Jiachong Li
    • Current Optics and Photonics
    • /
    • v.8 no.1
    • /
    • pp.97-104
    • /
    • 2024
  • In aerial cameras, image quality is easily affected by weather, temperature, and the attitude of the aircraft. Aiming at this phenomenon, based on the theory of two-step zoom optical systems, a dual-band optical-despun two-step zoom optical system is designed. The system has a small field of view of 2.00° × 1.60°, and a large field of view of 4.00° × 3.20°. In the zoom process, the wavelength range is 0.45-0.70 ㎛ and 0.75-1.10 ㎛, and the size of the optical system is 168 mm (L) × 90 mm (W) × 60 mm (H). The overall lens weight is only 170.8 g, which has advantages for miniaturization and light weight. At the Nyquist frequency of 104 lp/mm, the modulation transfer function of the visible-light optical system is more than 0.44, and that of the near-infrared optical system is more than 0.30, both of which have good imaging quality and tolerance characteristics in the range of -45 to 60 ℃.

A Potential New Mouse Model of Axial Spondyloarthritis Involving the Complement System

  • V. Michael Holers;Francisco G. La Rosa;Nirmal K. Banda
    • IMMUNE NETWORK
    • /
    • v.21 no.6
    • /
    • pp.45.1-45.13
    • /
    • 2021
  • Many mouse models of rheumatoid arthritis have been identified, but only a limited number are present for axial spondyloarthritis (AxSpA). Collagen Ab-induced arthritis (CAIA) is one of the most widely used mouse models of arthritis, and it is complement-dependent. We found that mice developing CAIA also developed spinal lesions similar to those found in AxSpA. To induce CAIA, mice were injected intraperitoneally at day 0 with anti-collagen Abs, followed by LPS injection at day 3. CAIA mice demonstrated a significant kyphosis through the spine, as well as hypertrophic cartilage and osseous damage of the intravertebral joints. Immunohistochemical staining of the kyphotic area revealed increased complement C3 deposition and macrophage infiltration, with localization to the intravertebral joint margins. Near Infrared (NIR) in vivo imaging showed that anti-collagen Abs conjugated with IRDye® 800CW not only localized to cartilage surface in the joints but also to the spine in arthritic mice. We report here a novel preclinical mouse model in which, associated with the induction of CAIA, mice also exhibited salient features of AxSpA; this new experimental model of AxSpA may allow investigators to shed light on the local causal mechanisms of AxSpA bone and soft tissue changes as well as treatment.

Development of Passive Millimeter-wave Security Screening System (수동 밀리미터파 보안 검색 시스템 개발)

  • Yoon, Jin-Seob;Jung, Kyung Kwon;Chae, Yeon-Sik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.7
    • /
    • pp.138-143
    • /
    • 2016
  • The designed and fabricated millimeter-wave security screening system receives radiation energy from an object and a human body. The imaging system consist of sixteen array antennas, sixteen four-stage LNAs, sixteen detectors, an infrared camera, a CCD camera, reflector, and a focusing lens. This system requires high sensitivity and wide bandwidth to detect the input thermal noise. The LNA module of the system has been measured to have 65.8 dB in average linear gain and 82 GHz~102 GHz in bandwidth to enhance the sensitivity for thermal noise, and to receive it over a wide bandwidth. The detector is used for direct current (DC) output translation of millimeter-wave signals with a zero bias Schottky diode. The lens and front-end of the millimeter-wave sensor are important in the system to detect the input thermal noise signal. The frequency range in the receiving sensitivity of the detectors was 350 to 400 mV/mW at 0 dBm (1 mW) input power. The developed W-band imaging system is effective for detecting and identifying concealed objects such as metal or plastic.

Current on the Heat Loss in Greenhouses during Winter Season - Case Study Based on Gyeongnam Area - (동절기 온실의 열 손실에 관한 실태조사 - 경남지역을 중심으로 -)

  • Im, Jae Un;Yun, Sung Wook;Kim, Hyeon Tae;Yoon, Yong Cheol
    • Journal of Bio-Environment Control
    • /
    • v.22 no.1
    • /
    • pp.73-79
    • /
    • 2013
  • An experiment was conducted to study incidences of heat loss in greenhouse in Gyeongnam province using thermal imaging camera in order to determine ways minimizing greenhouse heat loss. Measurements of this work showed that temperature differences between two experiment zones before and after installation of thermal curtains were about $2.0{\sim}3.0^{\circ}C$ and $1.0{\sim}2.0^{\circ}C$ respectively. There was a high correlation between the temperature data measured using a thermal imaging camera and a temperature sensor. There was no serious difference among areas, but between places on the first and second floor with thermal curtains for heat insulation, there was a relatively larger heat loss on the first floor than the second floor. Then in general the greenhouse types had no particular bearing on this matter, there was a relatively large heat loss in the parts of side wall window, the gaps and the parts folded of horizontal thermal curtains, the gutter parts, and the gaps of thermal curtain in the side wall window and facade back side for heat insulation, aren't completely sealed. It was found that there was a substantial heat loss due to infiltration through cracks on covering material, doors, ventilating openings, roof gables and floors, in particular.

Inter-Annual Variability of Ice Cap in Himalaya (히말라야산맥의 만년설 경년변화 연구)

  • Lee, Chang-Suk;Han, Kyung-Soo;Yeom, Jong-Min;Lee, Ga-Lam;Song, Bong-Guen
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.11 no.4
    • /
    • pp.32-40
    • /
    • 2008
  • In this study, we monitor ice cap using calculated NDSI from September to December in 2001, 2003, 2006, 2007 and snow cover area in 2007 decrease by compare with 2001. Global warming is one of the most important issue in this world. Because global-warming is the reason of various meteorological disasters and extreme weather events in these days and snow and glaciers showed that global warming effect most easily. Snow and glaciers play an important role in Earth cooling system because of their high reflectance. The present study has been carried out monitoring ice cap in Himalayas, using MODIS(Moderate Resolution Imaging Spectroradiometer)data. Indicator to monitoring ice cap, NDSI(Normalized Differenced Snow Index) was used in this study. The NDSI is a spectral band ratio that takes advantage of the spectral differences of snow in visible and short-wave infrared domain to detect snow cover area versus non-snow cover area in a scene. This study is quantitative evaluation about effect of global warming for icecap.

  • PDF

A Study on the Design and Implementation of a Thermal Imaging Temperature Screening System for Monitoring the Risk of Infectious Diseases in Enclosed Indoor Spaces (밀폐공간 내 감염병 위험도 모니터링을 위한 열화상 온도 스크리닝 시스템 설계 및 구현에 대한 연구)

  • Jae-Young, Jung;You-Jin, Kim
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.12 no.2
    • /
    • pp.85-92
    • /
    • 2023
  • Respiratory infections such as COVID-19 mainly occur within enclosed spaces. The presence or absence of abnormal symptoms of respiratory infectious diseases is judged through initial symptoms such as fever, cough, sneezing and difficulty breathing, and constant monitoring of these early symptoms is required. In this paper, image matching correction was performed for the RGB camera module and the thermal imaging camera module, and the temperature of the thermal imaging camera module for the measurement environment was calibrated using a blackbody. To detection the target recommended by the standard, a deep learning-based object recognition algorithm and the inner canthus recognition model were developed, and the model accuracy was derived by applying a dataset of 100 experimenters. Also, the error according to the measured distance was corrected through the object distance measurement using the Lidar module and the linear regression correction module. To measure the performance of the proposed model, an experimental environment consisting of a motor stage, an infrared thermography temperature screening system and a blackbody was established, and the error accuracy within 0.28℃ was shown as a result of temperature measurement according to a variable distance between 1m and 3.5 m.

Assembly and Testing of a Visible and Near-infrared Spectrometer with a Shack-Hartmann Wavefront Sensor (샤크-하트만 센서를 이용한 가시광 및 근적외선 분광기 조립 및 평가)

  • Hwang, Sung Lyoung;Lee, Jun Ho;Jeong, Do Hwan;Hong, Jin Suk;Kim, Young Soo;Kim, Yeon Soo;Kim, Hyun Sook
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.3
    • /
    • pp.108-115
    • /
    • 2017
  • We report the assembly procedure and performance evaluation of a visible and near-infrared spectrometer in the wavelength region of 400-900 nm, which is later to be combined with fore-optics (a telescope) to form a f/2.5 imaging spectrometer with a field of view of ${\pm}7.68^{\circ}$. The detector at the final image plane is a $640{\times}480$ charge-coupled device with a $24{\mu}m$ pixel size. The spectrometer is in an Offner relay configuration consisting of two concentric, spherical mirrors, the secondary of which is replaced by a convex grating mirror. A double-pass test method with an interferometer is often applied in the assembly process of precision optics, but was excluded from our study due to a large residual wavefront error (WFE) in optical design of 210 nm ($0.35{\lambda}$ at 600 nm) root-mean-square (RMS). This results in a single-path test method with a Shack-Hartmann sensor. The final assembly was tested to have a RMS WFE increase of less than 90 nm over the entire field of view, a keystone of 0.08 pixels, a smile of 1.13 pixels and a spectral resolution of 4.32 nm. During the procedure, we confirmed the validity of using a Shack-Hartmann wavefront sensor to monitor alignment in the assembly of an Offner-like spectrometer.

Conservation and Scientific Analysis of Human Bone Excavated in Sabi Period of Baekje from Eungpyeong-ri, Buyeo (부여 응평리 출토 백제 사비기 인골 보존처리 및 과학적 분석)

  • KIM, Mijeong;LEE, Yunseop;CHO, Eunmin;PARK, Sujin;MOON, Minseong
    • Korean Journal of Heritage: History & Science
    • /
    • v.55 no.1
    • /
    • pp.305-321
    • /
    • 2022
  • The stone chamber tomb in Eungpyeong-ri, Buyeo, is a joint tomb that contains the bodies of two individuals. This paper investigates the relationship between the buried persons and the characteristics of the stone chamber tomb. Based on the geographical location, relics, and the excavated human bones, it was determined that the tomb was built during the Sabi Period of the Baekje Dynasty and that the buried individuals were most probably residents of high stature or government officials. To study the excavated bones, the remains were carefully collected and conservation was carried out. Before collecting samples from the human bones for the analytical research, the results of near-infrared analysis were used to collect the samples for the isotope analysis and DNA analysis. The most important issue when handling the excavation site was the reinforcing agent and the concentration of the agent used. In situations like this, Paraloid B-72 is the most suitable agent. When the shape of human bones was difficult to distinguish from the soil, conservation was performed using X-ray and CT imaging data. The same chemical used for the reinforcement of the site was used to complete a minimum level of conservation to the surface areas where the conservation treatment of removing foreign substances, the reinforcement areas, and bonded areas were carried out. The collagen yield from the sample obtained at selected position was 3.8% to 6.1%. The results of analyzing the stable isotopes of carbon and nitrogen found in the extracted collagen showed that the stable isotope ratios came out to δ13C -18.3‰±0.1‰, -19.0‰±0.1‰ for EBW and δ15N 10.7‰±0.5‰, 10.6‰±0.1‰ for EBE. It is believed the two individuals consumed small amounts of minor cereals, mainly from C3 plants, and protein was obtained from eating terrestrial animals. What's more, the deviations in data obtained from the two individuals were so small that it could be inferred that the individuals ate similar foods. Considering the preservation state of the sample, amplifying DNA for the DNA analysis would have been very difficult since the amount of surviving DNA was so deficient. For DNA analysis, it is anticipated that the results could be derived by applying improved extraction methods that will be developed in the future. In this research, any association between scientific analysis(DNA and stable isotope ratio) and near-infrared spectroscopy was difficult to establish. Further research is needed on the utilization of near-infrared analysis for gathering samples from human bones.

Comparative Evaluation of UAV NIR Imagery versusin-situ Point Photo in Surveying Urban Tributary Vegetation (도심소하천 식생조사에서 현장사진과 UAV 근적외선 영상의 비교평가)

  • Lee, Jung-Joo;Hwang, Young-Seok;Park, Seong-Il;Um, Jung-Sup
    • Journal of Environmental Impact Assessment
    • /
    • v.27 no.5
    • /
    • pp.475-488
    • /
    • 2018
  • Surveying urban tributary vegetation is based mainly on field sampling at present. The tributary vegetation survey integrating UAV NIR(Unmanned Aerial Vehicle Near Infrared Radiance) imagery and in-situ point photo has received only limited attentions from the field ecologist. The reason for this could be the largely undemonstrated applicability of UAV NIR imagery by the field ecologist as a monitoring tool for urban tributary vegetation. The principal advantage of UAV NIR imagery as a remote sensor is to provide, in a cost-effective manner, information required for a very narrow swath target such as urban tributary (10m width or so), utilizing very low altitude flight, real-time geo-referencing and stereo imaging. An exhaustive and realistic comparison of the two techniques was conducted, based on operational customer requirement of urban tributary vegetation survey: synoptic information, ground detail and quantitative data collection. UAV NIR imagery made it possible to identify area-wide patterns of the major plant communities subject to many different influences (e.g. artificial land use pattern), which cannot be acquired by traditional field sampling. Although field survey has already gained worldwide recognition by plant ecologists as a typical method of urban tributary vegetation monitoring, this approach did not provide a level of information that is either scientifically reliable or economically feasible in terms of urban tributary vegetation (e.g. remedial field works). It is anticipated that this research output could be used as a valuable reference for area-wide information obtained by UAV NIR imagery in urban tributary vegetation survey.

An Analysis of Spectral Characteristic Information on the Water Level Changes and Bed Materials (수위변화에 따른 하상재료의 분광특성정보 분석)

  • Kang, Joongu;Lee, Changhun;Kim, Jihyun;Ko, Dongwoo;Kim, Jongtae
    • Ecology and Resilient Infrastructure
    • /
    • v.6 no.4
    • /
    • pp.243-249
    • /
    • 2019
  • The purpose of this study is to analyze the reflectance of bed materials according to changes in the water level using a drone-based hyperspectral sensor. For this purpose, we took hyperspectral images of bed materials such as soil, gravel, cobble, reed, and vegetation to compare and analyze the spectral data of each material. To adjust the water level, we constructed an experimental channel to control the discharge and installed the bed materials within the channel. In this study, we configured 3 cases according to the water level (0.0 m, 0.3 m, 0.6 m). After the imaging process, we used the mean value of 10 points for each bed material as analytical data. According to the analysis, each material showed a similar reflectance by wavelength and the intrinsic reflectance characteristics of each material were shown in the visible and near-infrared region. Also, the deeper the water level, the lower the peak reflectance in the visible and near-infrared region, and the rate of decrease differed depending on the bed material. We expect the intrinsic properties of these bed materials to be used as basic research data to evaluate river environments in the future.