• Title/Summary/Keyword: Infrared: imaging

Search Result 763, Processing Time 0.032 seconds

The Study About the Correlation between Assessment Instruments of Knee OA and DITI (퇴행성 슬관절염 평가도구와 적외선 체열촬영과의 상관관계 연구)

  • Kim, Hyee-Kwon;Lee, Sang-Hoon;Seo, Jung-Chul;Lee, Seung-Deok;Choi, Sun-Mi;Kim, Yong-Seok
    • Journal of Acupuncture Research
    • /
    • v.23 no.1
    • /
    • pp.155-164
    • /
    • 2006
  • Objectives : The aim of this study is to validate the correlation between Assessment Instruments of Knee OA and digital infrared thermographic imaging(DITI) and to find out the methods to assess knee OA by DITI. Methods : 60 subjects were evaluated. They were asked to answer VAS pain scale, WOMAC, KHAQ and LFI. Correlation was assessed by examining the spearman's rank correlation coefficients. Results : VAS, WOMAC and LFI was correlated with not only the thermal difference between Ant. knee and Post. knee, but also the lowest temperature of Ant. knee. Conclusion: DITI value was useful for evaluating the degree of OA. And we should find out that decrease of pain is correlated with change of DITI value.

  • PDF

Case Report of Korean Medical Treatment on Acute Peroneal Nerve Palsy Patient Caused by Prolonged Immobilization (장시간 부동 자세로 야기된 급성 비골신경 마비 환자의 한방치료 증례보고)

  • Kim, Min-Soo;Kim, Jin-Hee;Lee, Ji-Young;Yeom, Seung-Ryong;Kwon, Young-Dal
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.25 no.3
    • /
    • pp.127-136
    • /
    • 2015
  • Objectives This study was carried out to investigate the clinical effects of Korean medical treatment on acute peroneal nerve palsy caused by prolonged immobilization. Methods One patient with acute peroneal nerve palsy was treated with various korean medical techniques such as acupuncture, moxibustion, cupping and herbal medicine, bee-venom acupuncture for 12 weeks. Manual Muscle Test, Range of motion, Numerical Rating Scale, Ankle-hindfoot scale, Digital infrared thermographing imaging system were used to evaluate treatment effect. Results After treatment, all the scales mentioned above were improved significantly. Conclusions This result showed that Korean medical treatment is effective on acute peroneal nerve palsy caused by prolonged immoblization.

The Clinical Study on a Case of Fibromyalgia Syndrome Patient by Korean Medicine Treatment (섬유근통 환자의 한의학적 치료 효과 증례보고)

  • Lee, Ji-Young;Kim, Min-Su;Yeom, Seung-Ryong;Kwon, Young-Dal
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.26 no.4
    • /
    • pp.127-136
    • /
    • 2016
  • The purpose of this study is to report a clinical progress of fibromyalgia syndrom patient treated by Korean Medicine treatment. The patient was treated with acupuncture, acupotomy, pharmacopuncture (Bee venom, Hwangryun, Hominis Placental), herbal medicine, moxibustion, cupping treatment. We measured Visual Analogue Scale (VAS), American College of Rheumatology Preliminary Diagnostic Criteria (ACR, 2010), Fibromyalgia Impact Qustionnaire (FIQ), and observed the change in body temperature using Digital Infrared Thermal Imaging (DITI). After Korean Medicine treatment, pain was controlled and VAS, ACR, FIQ were decreased. The result showed that Korean Medicine treatment is effective in fibromyalgia syndrome.

Study on spaceborne telescope structure with high stability using new composite materials (신소재 복합재료를 이용한 우주용 카메라 구조의 고안정화 설계에 관한 연구)

  • EUNG-SHIK LEE;SUN-HEE WOO
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2003.10a
    • /
    • pp.132-136
    • /
    • 2003
  • A Multi-Spectral Camera (MSC) is the payload of KOMPSAT-2 which is designed for earth imaging in visible and near-Infrared region on a sun-synchronous orbit. The telescope in the MSC is a Ritchey-Chretien type with large aperture. The telescope structure should be well stabilized and the optical alignment should be kept steady so that best images can be achieved. However, the MSC is exposed to adverse thermal environment on the orbit which can give impacts on optical performance. Metering structure which is exposed to adverse space environment should have tight requirement of low thermal expansion and hygroscopic stability. In order to meet those stability requirements in addition to fundamental structural ones telescope structure was designed with newly developed graphite-cyanate composite which has high tensile modulus, high thermal conductivity and low moisture absorption compared with conventional graphite-epoxy composite. In this paper, space-borne telescope structure with new composite material will be presented and fulfillment of stability requirements will be verified with designed structure.

  • PDF

Characteristics of Heat Generation in time of High-speed Machining using Infrared Thermal Imaging Camera (적외선 열화상 카메라를 이용한 고속가공에서의 열 발생 특성)

  • Lee, Sang-Jin;Park, Won-Kyu;Lee, Sang-Tae;Lee, Woo-Young;Ha, Man-Kyung
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.2 no.3
    • /
    • pp.26-33
    • /
    • 2003
  • The term 'High Speed Machining' has been used for many years to describe end milling with small diameter tools at high rotational speeds, typically 10,000-100,000rpm. The process was applied in the aerospace industry for the machining of light alloys, notably aluminum. In recent year, however, the mold and die industry has begun to use the technology for the production of components, including those manufactured from hardened tool steels. With increasing cutting speed used in modern machining operation, the thermal aspects of cutting become more and mole Important. It not only directly influences in rate of tool weal, but also affects machining precision recognized as thermal expansion and the roughness of the surface finish. Hence, one needs to accurately evaluate the rate of cutting heat generation and temperature distributions on the machining surface. To overcome the heat generation, we used to cutting fluid. Cutting fluid plays a roles in metal cutting process. Mechanically coupled effectiveness of cutting fluids affect to friction coefficient at tool-workpiece interface and cutting temperature and chip control, surface finish, tool wear and form accuracy. Through this study, we examined the behavior of heat generation in high-speed machining and the cooling performance of various cooling methods.

  • PDF

The Results of Yangdorak(良導絡) and D.I.T.I,, according to Deficiency or Excess(虛實) of Acne Patients (여드름 환자의 허실(虛實)에 따른 양도락(良導絡) 및 적외선체열진단 결과 분석)

  • Jung, Min-Young;Kim, Dae-Su;Park, Su-Yeon;Kim, Jong-Han;Choi, Jeong-Hwa;Park, Yong-Ho
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.20 no.2 s.33
    • /
    • pp.171-178
    • /
    • 2007
  • Objective : The aim of this study was to evaluate Yangdorak and D.I.T.I. for analysis of Symptom-complexes. Method : This study was selected 26 acne patients in Dongshin University Oriental Medical Hospital. We used Yangdorak (SME5800N, Sord Medicom Co., Korea) and D.I.T.I. (Digital Infrared Thermal Imaging 256, Dorex Inc, Orange CA, USA) and investigated the results of Yangdorak and D.I.T.I.. We made a comparison according to Deficiency or Excess(虛實) of acne patients. Result : In comparing Yangdorak results according to Deficiency or Excess(虛實) of acne patients, Triple-energizer(三焦), Intestine(大腸), Liver(肝), Stomach(胃) meridian in Excess group are higher than Deficiency group, and Kidney(腎) meridian in Deficiency group are lower than Excess group. D.I.T.I. reveald hyperthemia of face and chest on acne patients. The temperature of face and chest on Excess group is higher than Deficiency group. There is no statistically significant value compared with data of other group.

  • PDF

Dust Properties in Afterglow of GRB071025 at z~5: Evidence for Supernovae-produced Dust in the Early Universe

  • Jang, Min-Sung;Im, Myung-Shin;Lee, In-Duk;Urata, Y.;Huang, L.;Fan, Xiaohui;Jiang, Lihua
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.2
    • /
    • pp.35.2-35.2
    • /
    • 2010
  • It is crucial to understand the dust properties in the early universe since they provide important clues about how the early cosmic star formation should be interpreted in the presence of dust extinction. GRB 071025 is an unusually red GRB that occured at high redshift, offering an unique opportunity to study the dust properties in the early universe. We investigate the extinction properties of GRB 071025 through the analysis of RIJHK data obtained with the 1-m telescope at Mt. Lemmon Optical Astronomy Observatory (LOAO) and Simultaneous Quad Infrared Imaging Device (SQIID) on the Kitt-Peak Mayall 4-m telescope. Our dataset is independent from that in a previous work (Perley et al. 2010) where a small systematic photometric errors could complicate the interpretation. After determining the temporal power law exponent with five I-band frames from LOAO, we construct a multi-band monochromatic SED of the GRB afterglow. By using various extinction laws, we find that the SED is best fitted with models that incorporate SNe II dust and derive a photometric redshift of 4.99(+0.12/-0.03). Our results strongly support the prior claim that dusts in GRB 071025 originate mainly from supernovae, implying SNe II predominantly contributed to the dust enrichment in the early universe (z ~ 5).

  • PDF

Survey of Electro-Optical Infrared Sensor for UAV

  • Jang, Seung-Won;Kim, Joong-Wook
    • Current Industrial and Technological Trends in Aerospace
    • /
    • v.6 no.1
    • /
    • pp.124-134
    • /
    • 2008
  • The rising demand for the high efficiency and high covertness in UAV motivates the miniature design of the high performing mission sensors, or payloads. One of the promising payload sensors, EO/IR sensor has evolved satisfying its demands and became the main stand-alone mission sensor for 200kg-range UAV. One aspect in development of EO/IR sensor concerns lack of specification criterions to represent its performance. Even though the high demand and competition among each manufacturer caused EO/IR features subject to rapid change collateral to new technology, the datasheets maintained the conventional outdated formats which leave some of the major components in ambiguity. Making comparisons or predicting actual performance with such datasheets is hardly worthwhile; yet, they could be important reference guide for the potential customers what to expect for the upcoming EO/IR. According to UAS Roadmap 2007-2032 published by DoD, one of the main potential customers as well as a main investor of EO/IR technology, EO/IR is expected to play key roll in solving urgent problems, such as see and avoid system. This paper will examine the recent representative EO/IR specialized in UAS missions through datasheets to find out current trend and eventually extrapolate the possible future trend.

  • PDF

Manufacture of Aspheric Lens Using Thermal Image Optics (열영상 광학계용 비구면 렌즈 제작)

  • Kim, Dae-Jung;Gu, Hal-Bon;Kim, Shang-Suk;Kim, Jeong-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.191-194
    • /
    • 2003
  • Through using aspheric lens can result in advantages such as an improved optical transfer function, a reduced distortion path or the realization of special image field curvatures. Using the diamond turning method for generating aspherics, the company claim to be able to generate surfaces with a form error of less than $0.33\;{\mu}\;m$ and a surface roughness of less than $0.025\;{\mu}\;m$. In this paper, we are manufacturing thermal image aspheric lens. Thermal image system is electro-optical imaging device which can make visible the difference of infrared energy naturally emitted by objected. In the result of aspherical surface, the form accuracy of about $0.24\;{\mu}\;m$ P-V was obtained and the surface roughness Ra $0.004\;{\mu}\;m$. Also, a brief review of Ultra-precision system Korea photonics technology institute(KOPTI) is present in this paper.

  • PDF

Case Report of Unspecified Tremor with Xerostomia Resulting from Psychometric Drug Intake Treated by Traditional Korean Medicine (한방치료로 호전된 상세불명의 떨림과 동반된 정신과계통 약물유발성 구강건조증 치험 1례)

  • Jung, Yu-jin;Kim, Minserh;Hong, Sang-hoon
    • The Journal of Internal Korean Medicine
    • /
    • v.39 no.5
    • /
    • pp.914-928
    • /
    • 2018
  • Objectives: This case report examines the effects of traditional Korean medicine for unspecified tremor with xerostomia caused by psychometric drug intake. Methods: A patient who suffered from unspecified tremor with xerostomia caused by psychometric drug intake was treated with acupuncture, pharmacopuncture, and traditional Korean medicine for 30 days. We provided the patient with herbal medicines including Ondam-tang-gagam (溫膽湯加減), Pumsimgieum-gagam (忿心氣陰加減), and Hoichunyanggyeok-san-gami (回春凉隔散加味). Symptoms were charted and evaluated using the Yin-deficiency questionnaire score, Yin-deficiency scale score, dry mouth symptom questionnaire, and visual analogue scale. Results: After treatment with Korean Medicine and pharmacopuncture, the frequency and degree of tremor has decreased, and degree of Xerostomia also improved. The Scores of Yin-deficiency questionnaire score, Yin-deficiency scale score, dry mouth symptom questionnaire, and visual analogue scale were also improved. And we could see reduction in the level of distribution of gastrointestinal heat at Digital Infrared Thermal Imaging test. The patient's Symtoms (Xerostomia as well as unspecified tremor) were improved after treated with Korean Medicine and pharmacopuncture. Conclusion: Korean medicine treatments may be valuable for xerostomia caused by psychometric drug intake.