• Title/Summary/Keyword: Infrared: imaging

Search Result 763, Processing Time 0.023 seconds

Development of Drought Stress Measurement Method for Red Pepper Leaves using Hyperspectral Short Wave Infrared Imaging Technique (초분광 단파적외선 영상 기술을 이용한 고추의 수분스트레스 측정 기술 개발)

  • Park, Eunsoo;Cho, Byoung-Kwan
    • Journal of Bio-Environment Control
    • /
    • v.23 no.1
    • /
    • pp.50-55
    • /
    • 2014
  • This study was conducted to investigate the responses of red pepper (Hongjinju) leaves under water stress. Hyperspectral short wave infrared (SWIR, 1000~1800 nm) reflectance imaging techniques were used to acquire the spectral images for the red pepper leaves with and without water stress. The acquired spectral data were analyzed with a multivariate analysis method of ANOVA (analysis of variance). The ANOVA model suggested that 1449 nm wavebands was the most effective to determine the stress responses of the red pepper leaves exposed to the water deficiency. The waveband of 1449 nm was closely related to the water absorption band. The processed spectral image of 1449 nm could separate the non-stress, moderate stress (-20 kPa), and severe stress (-50 kPa) groups of red pepper leaves distinctively. Results demonstrated that hyperspectral imaging technique can be applied to monitoring the stress responses of red pepper leaves which are an indicator of physiological and biochemical changes under water deficiency.

Infrared Thermal Imaging for Quantification of HIFU-induced Tissue Coagulation (적외선 이미징 기반 HIFU 응용 조직 응고 정량화 연구)

  • Pyo, Hanjae;Park, Suhyun;Kang, Hyun Wook
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.5
    • /
    • pp.236-240
    • /
    • 2017
  • In this paper, we investigate the thermal response of skin tissue to high-intensity focused ultrasound (HIFU) by means of infrared (IR) thermal imaging. For skin tightening, a 7-MHz ultrasound transducer is used to induce irreversible tissue coagulation in porcine skin. An IR camera is employed to monitor spatiotemporal changes of the temperature in the tissue. The maximum temperature in the tissue increased linearly with applied energy, up to $90^{\circ}C$. The extent of irreversible tissue coagulation (up to 3.2 mm in width) corresponds well to the spatial distribution of the temperature during HIFU sonication. Histological analysis confirms that the temperature beyond the coagulation threshold (${\sim}65^{\circ}C$) delineates the margin of collagen denaturation in the tissue. IR thermal imaging can be a feasible method for quantifying the degree of thermal coagulation in HIFU-induced skin treatment.

PANORAMIC MID-INFRARED VIEWS OF DISTANT CLUSTERS OF GALAXIES WITH AKARI

  • Koyama, Yusei
    • Publications of The Korean Astronomical Society
    • /
    • v.32 no.1
    • /
    • pp.287-291
    • /
    • 2017
  • We present the results of our mid-infrared (MIR) observations of distant clusters of galaxies with AKARI. The wide-field of view of IRC/AKARI ($10^{\prime}{\times}10^{\prime}$) is ideally suited for studying dust-obscured star-formation (SF) activity of galaxies along the cosmic web in the distant universe. We performed a deep and wide-field $15{\mu}m$ (rest-frame ${\approx}8{\mu}m$) imaging observation of the RXJ1716+6708 cluster (z = 0.81) with IRC. We find that $15{\mu}m$-detected cluster member galaxies (with total infrared luminosities of $L_{IR}{\geq}10^{11}L_{\odot}$) are most preferentially located in the cluster outskirt regions, whilst such IR-luminous galaxies avoid the cluster centre. Our $H{\alpha}$ follow-up study of this field confirmed that a significant fraction of $15{\mu}m$-detected cluster galaxies are heavily obscured by dust (with $AH{\alpha}$>3 mag in extreme cases). The environment of such dusty star-burst galaxies coincides with the place where we see a sharp "break" of the colour-density relation, suggesting an important link between dust-obscured SF activity and environmental quenching. We also report the discovery of a new cluster candidate around a radio galaxy at z = 1.52 (4C 65.22), where we obtained one of the deepest IRC imaging datasets with all the nine filters at $2-24{\mu}m$. This field will provide us with the final, excellent laboratory for studying the dust-enshrouded SF activity in galaxies along the cosmic web at the critical epoch of cluster galaxy evolution with AKARI.

Thermal Analysis of MIRIS Space Observation Camera for Verification of Passive Cooling

  • Lee, Duk-Hang;Han, Won-Yong;Moon, Bong-Kon;Park, Young-Sik;Jeong, Woong-Seob;Park, Kwi-Jong;Lee, Dae-Hee;Pyo, Jeong-Hyun;Kim, Il-Joong;Kim, Min-Gyu;Matsumoto, Toshio
    • Journal of Astronomy and Space Sciences
    • /
    • v.29 no.3
    • /
    • pp.305-313
    • /
    • 2012
  • We conducted thermal analyses and cooling tests of the space observation camera (SOC) of the multi-purpose infrared imaging system (MIRIS) to verify passive cooling. The thermal analyses were conducted with NX 7.0 TMG for two cases of attitude of the MIRIS: for the worst hot case and normal case. Through the thermal analyses of the flight model, it was found that even in the worst case the telescope could be cooled to less than $206^{\circ}K$. This is similar to the results of the passive cooling test (${\sim}200.2^{\circ}K$). For the normal attitude case of the analysis, on the other hand, the SOC telescope was cooled to about $160^{\circ}K$ in 10 days. Based on the results of these analyses and the test, it was determined that the telescope of the MIRIS SOC could be successfully cooled to below $200^{\circ}K$ with passive cooling. The SOC is, therefore, expected to have optimal performance under cooled conditions in orbit.

FABRICATION AND ALIGNMENT OF PARTS OF THE KASINICS OFFNER SYSTEM (KASINICS 오프닝 광학계의 부품 가공 및 정렬)

  • Mok, Seung-Won;Lee, Sung-Ho;Yuk, In-Soo;Park, Young-Sik;Jin, Ho;Han, Jeong-Yeo;Moon, Bong-Kon;Cha, Sang-Mok;Kim, Geon-Hee;Im, Myung-Shin
    • Publications of The Korean Astronomical Society
    • /
    • v.21 no.2
    • /
    • pp.43-49
    • /
    • 2006
  • The KASINICS (KASI Near Infrared Camera System) is a ground-based Near-Infrared (NIR) imaging instrument developed by the Korea Astronomy and Space Science Institute (KASI). In this paper, we report the test results of the KASINICS camera optics system which is comprised of a 1-1 Offner relay. We measure that the surface RMS fluctuations of the Offner mirrors are at the level of $10^{-1}-10^{-2}$ of the target wavelengths, showing that the mirrors are sufficiently smooth for NIR observations. The alignment of the Offner optics system has been checked too. Our ray-tracing simulations find that the image quality should not degrade more than the pixel size of the KASINICS ($40{\mu}m$), if a de-centering or a tilt of the Offner mirrors are within 5mm, or $2.5^{\circ}$. Our measurement shows that the de-centering or the tilt of the Offner mirrors are less than 1 mm or $0.5^{\circ}$, assuring that the KASINICS image quality are not affected by the alignment errors. We have also measured that the optics resolution is $20{\mu}m$ and it does not degrade more than 10% over the detector surface area of 14.3 mm ${/times}$ 14.3mm. Overall, we conclude that the KASINICS optics system satisfies the design requirements for NIR imaging observations.

Predicting lipoabdominoplasty complications with infrared thermography: a delta-R analysis

  • Resende, Patricia Rodrigues;Brioschi, Marcos Leal;Meneck, Franciele De;Neves, Eduardo Borba;Teixeira, Manoel Jacobsen
    • Archives of Plastic Surgery
    • /
    • v.48 no.5
    • /
    • pp.553-558
    • /
    • 2021
  • The diagnosis of the main complications resulting from lipoabdominoplasty has not yet been standardized. Infrared thermal imaging has been used to assess possible complications, such as necrosis and changes in micro- and macro-circulation, based on perforator mapping techniques, among others. The objective of this study was to present two clinical cases involving thermal imaging monitoring of the healing process of lipoabdominoplasty in the immediate postoperative evaluation and its preliminary results. Infrared thermography was performed 24 hours after the operation and on postoperative days 5, 25, and 27. In clinical case 1, it was found that the delta-R (∆TR)-defined as the difference in minimum temperature between the highest and lowest points in the SA3 region (caution suction area) following the classification established by Matarasso-was 0.4℃ at 24 hours after surgery and decreased to 0.1℃ on a postoperative day 5. There were no complications in this case. In contrast, in clinical case 2, the ∆TR was 1.7℃ at 24 hours after surgery (upon hospital discharge) and remained high, at 2.2℃, on postoperative day 5. A higher ∆TR was found in the second patient, who developed necrosis of the surgical wound. The ∆TR thermal index may be a new tool for predicting possible complications, complementing the clinical evaluation and therapeutic decision-making.

A Case of Intra-thyroidal Parathyroid Adenoma Confirmed by Intraoperative Near-infrared Autofluorescence (수술 중 근적외선 자가형광으로 확인된 갑상선 내부의 부갑상선 선종 1예)

  • Dong Gyu Choi;Jun Sang Cha;Yeong Joon Kim;Hyoung Shin Lee;Kang Dae Lee
    • Korean Journal of Head & Neck Oncology
    • /
    • v.39 no.1
    • /
    • pp.53-57
    • /
    • 2023
  • In general, the anatomical location and number of parathyroid glands are well known, but they are often found in a variety of locations, making it difficult to find parathyroid glands during surgery. Besides Intra-thyroidal parathyroid adenoma is extremely rare case, and it is harder to identify in surgery. We encountered a 51-year-old patient with a thyroid nodule. The results of the additional blood test and the Tc-99m MIBI were combined to determine that the left lower lobe parathyroid adenoma was highly likely. This patient was treated with left thyroid lobectomy with parathyroid identification using Near-infrared (NIR) imaging. Afterwards, the biopsy confirmed that it was a parathyroid adenoma, and has since been monitored through outpatient observation without any problem. We present this rare case with a review of related literatures.

Correlation Analysis of Reflectance and Turbidity through Spectral Characteristics of Near-Infrared (근적외선의 분광특성 분석을 통한 반사율과 탁도의 상관관계 분석)

  • Lee, So-Jin;Jeong, Gyo-Cheol;Lee, Chang-Ju;Kim, Jong-Tae
    • The Journal of Engineering Geology
    • /
    • v.32 no.1
    • /
    • pp.101-111
    • /
    • 2022
  • This study analyzed the relationship between water turbidity and its reflectance, as measured using hyperspectral imaging. First, samples of turbid water were generated in boxes. This was followed by drone-based hyperspectral imaging and analysis of the correlation between the samples' measured turbidity and hyperspectral reflectance. The nine boxes for turbidity measurement were made of black acrylic that absorbed all light turbidity was induced using soil collected near Changhacheon, which causes turbidity in Imha Lake. The results indicate that the reflectance of wavelengths in the near-infrared region followed a pattern of increase with increasing soil content for each box. Analysis of this correlation between the turbidity and average reflectance measured in each box yielded a very high R2 value of 0.8702, indicating that reflectance is a suitable proxy for turbidity.

A Study on Measuring the Temperature and Revising the Result When Measuring the Temperature of NPP Pipes Using Infrared Thermography (적외선 열화상 기술을 이용한 원자력 배관의 온도측정과 보정에 관한 연구)

  • Kim, Kyeong-Suk;Jung, Hyun-Chul;Pack, Chan-Joo;Kim, Dong-Soo;Jung, Duk-Woon;Chang, Ho-Sub
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.5
    • /
    • pp.421-426
    • /
    • 2009
  • The emissivity is different because the emitted angle changes according to the position of the infrared thermography camera and object. Because of this, the temperature distribution expressed when measuring the temperature by using the infrared thermography system is not the accuracy temperature. Although the real surface temperature is constant, the temperature measured by using infrared thermography camera have error in accordance with the value of emissivity. In this paper, the temperatures of the round cylindrical object and the flat square object that heated to the equal temperature were measured by infrared thermography camera. The emissivity calibration formula and correction table are made with the affect of the view angle and emission angle form the surface temperature value. The error of measured temperature values are corrected by using the emissivity calibration formula and correction table, and apply to defect detection of the nuclear power plant pipe. From the calibration method, reliability surface temperature values were obtained.

Quantitative Analysis on Near Band Edge Images in GaAs Wafer (GaAs 웨이퍼의 대역단 영상에 대한 정량적 해석)

  • Kang, Seong-jun;Na, Cheolhun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.5
    • /
    • pp.861-868
    • /
    • 2017
  • Near band infrared imaging technique has adopted for imaging EL2 and shallow level distributions in undoped semi-insulating LEC GaAs. This technique, which relies on the mapping of near bandgap infrared transmission, is both rapid and non-destructive. Until now no quantitative analysis has been reported for near band edge region which gives the reverse contrast on EL2 absorption images. This paper presents the spectral, spatial and temperature dependence of photoquenching forward and inverse mechanism in the band edge domain for cells and walls and for direct and inverted contrast conditions during transitory regimes. The difference in the threshold for the EL2w and EL2b defects could be attributed to the contribution of a different electrical assistance due to a different species of impurities. Quantitative analysis results show an increased density of EL2w and a small reduction of EL2b in the region of the walls where there is a high density of dislocations.