• Title/Summary/Keyword: Infra Red

Search Result 484, Processing Time 0.028 seconds

Test Research Using an IR Thermography Technique in a Supersonic Wind Tunnel (초음속 풍동에서의 IR Thermography 기법을 활용한 시험연구)

  • Kim, Ikhyun;Lee, Jaeho;Park, Gisu;Byun, Yunghwan;Lee, Jongkook
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.2
    • /
    • pp.99-107
    • /
    • 2016
  • Test research on Infra-Red Thermography(IRT) technique in a supersonic wind tunnel has been conducted. Inadvertent technical difficulties and their solutions associated with the technique in running of the facility were examined. Two flow conditions at Mach number of 3 and 4 were considered. A double compression ramp model, that replicates realistic high-speed vehicle configuration, was used as test model. The present IR data were compared with shadowgraph visualization images and laminar computational fluid dynamics(CFD) results. It has been shown that the IRT technique can be used in quantifying various fluid dynamic features such as flow transition, separation and three-dimensional phenomena around the double compression ramp model.

Research of Developing of Standards for Electronic Thermometers (전자식체온계 기준규격 개발 연구)

  • Kim, E.J.;Lee, M.J.;Lee, B.Y.;Park, K.G.;Kim, D.S.;Lee, I.S.;Park, H.D.;Jeong, H.K.
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.2
    • /
    • pp.123-128
    • /
    • 2010
  • The thermometers is widely used in diagnostic medical devices, and the safety and accurate performance of these devices are important in the diagnosis and monitoring of personal health. Especially, the accuracy of infra-red thermometer is highly emphasized. Here two typical thermometers are utilized for this purpose: the electronic thermometers measure body temperature by contacting to subject while infra-red thermometers measure by no contacting to subject. Therefore, the evaluating items of each thermometer are different, and the standard for each temperature is highly needed. But, there have been no international standards of each thermometer such as IEC. In this paper, we developed the standards of electronic and infra-red thermometer based on national standards such as KS, ASTM, EN, JIS and FDA guidance. The new standards focused on the safety and suitable performance for health care. This standards were applied to enact and revise the electronic medical device standards. So it can be applied to evaluate the safety and performance on technical file review. We predict that this standard will improve the quality of diagnostic medical devices (thermometers) and increase the international competitive power of domestic product.

Cleanliness Test by Spray-Type Cleaning Agent for Electronic and Semiconductor Equipment (전자·반도체용 스프레이 분사형 세정제에 대한 청정도 평가)

  • Heo, Hyo Jung;Row, Kyung Ho
    • Korean Chemical Engineering Research
    • /
    • v.47 no.6
    • /
    • pp.688-694
    • /
    • 2009
  • A spray-type cleaning agent in utilizing dust-remover on PCB was chosen to study the cleanliness test and efficiency. In order to choose alternative environmental-friendly cleaning agents, it is important that the systematic selection procedures should be introduced and applied through the evaluation of their cleaning ability, environmental characteristics, and economical factors, and that the objective and effective evaluation methods of cleanliness should be established for the industry. A novel cleaning evaluation method with scanning electron microscopy/energy-dispersive X-ray analysis of surface observation evaluation method and an infra-red thermography camera(THERMOVISION A20 model) was studied in this work. The sound card(CT-2770 model) cut by $2{\times}2cm$ size was used as a part, and before and after the spray cleaning, the cleanliness was observed by the image analyzer of SEM and further the removal efficiency of dust was quantitatively evaluated by the component analysis of EDX. For the parts of P4TE model motherboard and IPC-A-36 PCB plate, before and after the spray cleaning, temperature differences were measured and compared at room temperature and 50 oven temperature by an infra-red thermography camera in the contaminants of dust and iron powder.

Implementation on Wi-Fi/IR Gateway and Smartphone Application for Integration and Control of Consumer Appliances (가전제품 통합 제어를 위한 Wi-Fi/IR 게이트웨이 및 스마트폰 애플리케이션 구현)

  • Ryu, Won Jae;Chae, Seog;Shin, Soo Young;Kim, Young Hyung;Jung, Dong Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.42 no.4
    • /
    • pp.879-888
    • /
    • 2017
  • Recently, the Smart household appliances to provide Smart services have been actively spreaded by providing IoT(Internet of Things). Also, the appliances which Wi-Fi and Bluetooth can directly control are preferred. But until now, the most household appliances are based on IR(InfraRed) and the each procotols of them are different. In this paper, to solve these problems, we suggested the system to control both smart appliances and general appliances by using Smart phone. The system is "Wi-Fi to IR" gateway which receives the Wi-Fi signal to convert to IR signal and transmit it. Also, we made the remote control function in specific brands' appliances possible to most brands without limitation and tried to control not only one remote controller for one TV brand but also for all brand without limitation.

Photoluminescence of the Single Crystal MnF2(1.5% EuF3) (단결정 MnF2(1.5% EuF3)의 Photoluminescence)

  • Kwon, Soon-Hyuk;Nahm, Kyun;Kim, Chul-Koo
    • Journal of the Korean Magnetics Society
    • /
    • v.17 no.1
    • /
    • pp.1-5
    • /
    • 2007
  • The 1R(Infra-Red) spectrum and PL(Photoluminescence) of the antiferromagnetic pure $MnF_2$ and the single crystal $MnF_2(1.5%\;EuF_3)$ with the rutile structures were measured. The detailed analysis of the measured PL data showed the differences of the optical property between the single crystal $MnF_2(1.5%\;EuF_3)$ and the pure $MnF_2$. It was found that the additional PL peak by the doping of the $EuF_3$ in $MnF_2$ is originated from the f-d transition of $Eu^{3+}$ from the temperature dependent intensity measurement.

An Experimental Study on the Dispersion Characteristics of Seawater Injection Nozzle for Hull Cooling (선체냉각을 위한 해수분사노즐의 산포특성에 관한 실험 연구)

  • Yoon, Seoktae;Jung, Hoseok;Cho, Yongjin
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.767-773
    • /
    • 2017
  • Infrared stealth is an important technology for naval ships. This technology helps improve the anti-detection performance and survivability of naval ships. In general, the infrared signature of naval ships are categorized into internal and external heat source. External signature are generated by ship surface heating by solar flux as well as the complicated heat transfer process with the surrounding weather condition. Modern naval ships are equipped with seawater injection nozzles on the outside for nuclear, biological and, chemical, and these nozzles are used to control external signature. Wide nozzle placement intervals and insufficient injection pressure, however, have reduced seawater dispersion area. To address this problem, nozzle installation standards must be established. In this study, an actual-scale experimental system was implemented to provide the evidence for nozzle installation standards in order to reduce the infrared signature of naval ships. In addition, the environmental conditions of the experiment were set up through computational fluid dynamics considering the ocean climate data and naval ship management conditions of South Korea. The dispersion distance was measured using a high-resolution thermography system. The flow rate, pipe pressure, and dispersion distance were analyzed, and the evidence for the installation of seawater injection nozzles and operation performance standards was suggested.

The Characteristics of Visible Reflectance and Infra Red Band over Snow Cover Area (적설역에서 나타나는 적외 휘도온도와 반사도 특성)

  • Yeom, Jong-Min;Han, Kyung-Soo;Lee, Ga-Lam
    • Korean Journal of Remote Sensing
    • /
    • v.25 no.2
    • /
    • pp.193-203
    • /
    • 2009
  • Snow cover is one of the important parameters since it determines surface energy balance and its variation. To classify snow and cloud from satellite data is very important process when inferring land surface information. Generally, misclassified cloud and snow pixel can lead directly to error factor for retrieval of surface products from satellite data. Therefore, in this study, we perform algorithm for detecting snow cover area with remote sensing data. We just utilize visible reflectance, and infrared channels rather than using NDSI (Normalized Difference Snow Index) which is one of optimized methods to detect snow cover. Because COMS MI (Meteorological Imager) channels doesn't include near infra-red, which is used to produce NDSI. Detecting snow cover with visible channel is well performed over clear sky area, but it is difficult to discriminate snow cover from mixed cloudy pixels. To improve those detecting abilities, brightness temperature difference (BTD) between 11 and 3.7 is used for snow detection. BTD method shows improved results than using only visible channel.

Intercomparison of Satellite-based Climate Hazards Group InfraRed Precipitation with Stations (CHIRPS) Gridded Dataset and Rain Gauge Data over Korea (Climate Hazards Group InfraRed Precipitation with Station (CHIRPS)와 한반도 지상관측 강수량 자료의 비교 평가)

  • Jeon, Min-Gi;Nam, Won-Ho;Mun, Young-Sik;Kim, Taegon;Hong, Eun-Mi
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.197-201
    • /
    • 2018
  • 인공위성 기반의 원격탐사자료는 홍수, 가뭄 등 자연재해에 대한 모니터링 및 예측에 활용되어 왔으며, 특히 인공위성을 이용한 광역적 강수량 추정 자료는 지형적 제약을 받는 지상관측자료와 비교하여 시공간적으로 연속적이고 균질한 강수량 자료 취득이 가능하다는 장점이 있다. 우리나라의 경우 상대적으로 조밀한 지상관측망이 구축되어 있어 공간적으로 상세한 강수량 정보를 생산할 수 있는 여건을 갖추고 있지만, 북한 지역의 경우 기상, 수문, 통계자료에 관한 자료의 접근 및 품질의 제한성으로 인해 미계측 지역에 대한 강수량의 추정에 한계가 있다. CHIRPS (Climate Hazards Group InfraRed Precipitation with Stations) 데이터는 1999년부터 미국국제개발처 (U.S. Agency for International Development, USAID), 미국항공우주국 (National Aeronautics and Space Administration, NASA), 미국해양대기청 (National Oceanic and Atmospheric Administration, NOAA)의 지원으로 개발된 전지구 강우데이터 자료이다. CHIRPS는 1981년부터 현재까지 전지구 강우자료를 0.05도 격자 해상도로 제공하고 있으며, 강수량의 추세 분석 및 가뭄 모니터링을 위해 활용되고 있다. 본 연구에서는 CHG (Climate Hazards Group)에서 제공하고 있는 인공위성을 이용한 광역적 강수량 추정 자료인 CHIRPS와 남한 및 북한의 지상관측 강수량 자료와의 비교를 통해 위성으로부터 유도된 격자 강수량자료의 정확도 및 지역적인 강수추정의 불확실성을 평가하고, 수자원 및 재해 분야 이용 가능성을 검토하고자 한다.

  • PDF

Application of Meteorological Drought Index using Climate Hazards Group InfraRed Precipitation with Station (CHIRPS) Based on Global Satellite-Assisted Precipitation Products in Korea (위성기반 Climate Hazards Group InfraRed Precipitation with Station (CHIRPS)를 활용한 한반도 지역의 기상학적 가뭄지수 적용)

  • Mun, Young-Sik;Nam, Won-Ho;Jeon, Min-Gi;Kim, Taegon;Hong, Eun-Mi;Hayes, Michael J.;Tsegaye, Tadesse
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.2
    • /
    • pp.1-11
    • /
    • 2019
  • Remote sensing products have long been used to monitor and forecast natural disasters. Satellite-derived rainfall products are becoming more accurate as space and time resolution improve, and are widely used in areas where measurement is difficult because of the periodic accumulation of images in large areas. In the case of North Korea, there is a limit to the estimation of precipitation for unmeasured areas due to the limited accessibility and quality of statistical data. CHIRPS (Climate Hazards Group InfraRed Precipitation with Stations) is global satellite-derived rainfall data of 0.05 degree grid resolution. It has been available since 1981 from USAID (U.S. Agency for International Development), NASA (National Aeronautics and Space Administration), NOAA (National Oceanic and Atmospheric Administration). This study evaluates the applicability of CHIRPS rainfall products for South Korea and North Korea by comparing CHIRPS data with ground observation data, and analyzing temporal and spatial drought trends using the Standardized Precipitation Index (SPI), a meteorological drought index available through CHIRPS. The results indicate that the data set performed well in assessing drought years (1994, 2000, 2015 and 2017). Overall, this study concludes that CHIRPS is a valuable tool for using data to estimate precipitation and drought monitoring in Korea.

Performance Evaluation of Measuring Instrument for Infra-Red Signature Suppression System Model Test (적외선 신호저감 장치 모형시험을 위한 계측기의 성능평가)

  • SeokTae Yoon
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.28 no.6
    • /
    • pp.21-27
    • /
    • 2023
  • Modern naval ships install an Infra-Red Signature Suppression system (IRSS) in their exhaust pipe to reduce infrared signature emitted to the outside. In addition, naval ships are strategic assets with a very long life cycle, so high reliability of the performance of the equipment on board must be guaranteed. Therefore, equipment such as IRSS is evaluated for performance through model testing at the design stage. A variety of measuring instruments are used in IRSS model testing, and the reliability of these instruments must also be guaranteed. In this paper, a study was conducted to evaluate the reliability of measurement equipment used in IRSS model testing. The test equipment and instruments used were a hot gas wind tunnel, pitot tube, digital differential pressure gauge, thermocouple sensor, and digital recorder. As the fan speed of the hot gas wind tunnel increased, the measurement deviation of the flow decreased, and the temperature output of the thermocouple sensor showed differences in response time and stability depending on the method used.