• Title/Summary/Keyword: Infra Red

Search Result 484, Processing Time 0.036 seconds

Performance Analysis of DSRC Transmission Efficiency at MAC Layer (MAC 계층에서의 DSRC 전송 효율 분석)

  • Kwag Su-Jin;Ahn Jin-Ho;Lee Sang-Sun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.6B
    • /
    • pp.527-533
    • /
    • 2006
  • In this paper, we analyze the performance of MAC (Media Access Control) layer in DSRC (Dedicated Short Range Communication). It will be widely applied for ITS (Intelligent Transportation System) services; for example ETC (Electric Toll Control), BIS (Bus Information System) etc., needed to small packet size. But If ITS service is evolving to advance ITS, ADIS (Advanced Driver Information Systems) and AVHS (Advanced Vehicle Highway System) etc, be needed larger packet size. In the future, it may offer more various services such as traffic information, collection, and multimedia information. There are two kind of physical media, IR(Infrared) and RF(Radio frequency). And each system has their own protocol that is adaptive in special characteristics of physical medium for using efficiently limited radio resources. In this paper, we analyze the special characteristics of each system. And we study practical use of some related services expected to be used in the near future, by analyzing the transmission efficiency in each DSRC system.

Flight Model Development of the MIRIS, the Main Payload of STSAT-3

  • Han, Won-Yong;Lee, Dae-Hee;Park, Young-Sik;Jeong, Woong-Seob;Moon, Bong-Kon;Park, Kwi-Jong;Park, Sung-Joon;Pyo, Jeong-Hyun;Lee, Duk-Hang;Nam, Uk-Won;Park, Jang-Hyun;Seon, Kwang-Il;Yang, Sun-Choel;Park, Jong-Oh;Rhee, Seung-Wu;Lee, Hyung-Mok;Matsumoto, Toshio
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.1
    • /
    • pp.65.1-65.1
    • /
    • 2012
  • MIRIS (Multipurpose Infra-Red Imaging System) is the first Korean Infrared Space Telescope developed by KASI (Korea Astronomy and Space Science Institute), and is the main payload of STSAT-3 (Science and Technology Satellite-3). The FM (fight model) of MIRIS has been recently completed, and various performance tests have been made to measure system parameters such as readout noise, system gain, linearity, and dark current. Final thermal-vacumm test of the MIRIS and the vibration test of the electronics box have been performed. Band response tests showed good agreement with the initial design requirements. No significant dark difference was measured within the expected temperature variation range during observation in orbit. Using Pa-alpha band from a uniform source, the readout noise and system gain were measured by mean variance test. To obtain uniform flat image, flat fielding tests were made for each band, and the data will be compared to that obtained in orbit for calibration. The final version of MIRIS FM will be delivered in March, and it will be integrated into the satellite system for the AIT (Assembly Integration, Test) procedure. The launch of MIRIS is expected in November 2012.

  • PDF

Modeling of THz Frequency Spectrum via Optical Rectification in THz Time Domain Spectroscopy (테라헤르츠 시간 영역 분광의 광정류시 발생하는 테라헤르츠 스펙트럼 모델링)

  • Lee, Kang-Hee;Yi, Min-Woo;Ahn, Jea-Wook
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.2
    • /
    • pp.119-124
    • /
    • 2008
  • In recent years, gradually increasing interest has been directed to the use of terahertz technology in nondestructive testing and non-invasive measurements, and terahertz time domain spectroscopy (THz-TDS) has become a key technology in such applications. This paper deals with the terahertz pulse generation from cadmium telluride via optical rectification process of femto-second infrared laser pulses. The measured terahertz spectrum is compared with the result of model calculation based on space-time domain nonlinear Maxwell equations for coherent frequency mixing process. The propagation process of terahertz and infra-red pulses in the material as well as the surface interference and free space diffraction effects are also considered. The experimental results are in good agreements with the calculated spectrum.

Bactericidal and wound disinfection efficacy of nanostructured titania

  • Azad, Abdul-Majeed;Aboelzahab, Asem;Goel, Vijay
    • Advances in materials Research
    • /
    • v.1 no.4
    • /
    • pp.311-347
    • /
    • 2012
  • Infections are caused due to the infiltration of tissue or organ space by infectious bacterial agents, among which Staphylococcus aureus bacteria are clinically most relevant. While current treatment modalities are in general quite effective, several bacterial strains exhibit high resistance to them, leading to complications and additional surgeries, thereby increasing the patient morbidity rates. Titanium dioxide is a celebrated photoactive material and has been utilized extensively in antibacterial functions, making it a leading infection mitigating agent. In view of the property amelioration in materials via nanofication, free-standing titania nanofibers (pure and nominally doped) and nanocoatings (on Ti and Ti6Al4V implants) were fabricated and evaluated to assess their efficacy to mitigate the viability and growth of S. aureus upon brief (30 s) activation by a portable hand-held infrared laser. In order to gauge the effect of exposure and its correlation with the antibacterial activities, both isolated (only titania substrate) and simultaneous (substrate submerged in the bacterial suspension) activations were performed. The bactericidal efficacy of the IR-activated $TiO_2$ nanocoatings was also tested against E. coli biofilms. Toxicity study was conducted to assess any potential harm to the tissue cells in the presence of photoactivated materials. These investigations showed that the photoactivated titania nanofibers caused greater than 97% bacterial necrosis of S. aureus. In the case of titania-coated Ti-implant surrogates, the bactericidal efficacy exceeded 90% in the case of pre-activation and was 100% in the case of simultaneous-activation. In addition to their high bactericidal efficacy against S. aureus, the benignity of titania nanofibers and nanocoatings towards tissue cells during in-vivo exposure was also demonstrated, making them safe for use in implant devices.

Design and fabrication of a zoom optics having 20 magnification range for mid-IR(3.7-4.8$\mu$m) FLIR system (3.7-4.8$\mu$m 파장대역 FLIR 시스템을 위한 20:1 줌 렌즈 광학계 설계 및 제작)

  • 김현숙;김창우;홍석민
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.6
    • /
    • pp.462-467
    • /
    • 1999
  • This paper describes the design and fabrication of mid-IR $(3.7-4.8{\mu}m)$ zoom optics which is used for FUR (Forward Looking Infra-Red) system with 320 $\times$ 240 focal plane arrays. The zoom optics has 20 magnification range and maximun 40$^{\circ}$$\times$30$^{\circ}$ of super wide field of view. The locus of zoom is almost linear, which gives easy access of mechanical and electro-mechanical design. The on-axis MTF of zoom optics has been measured and it shows diffraction limited optical performance. For example, it gives 0.692 at 24 cycles/mm at highest magnification, and 7.6 cycles/mradof resolving power is achieved with the operation of attached micro-scanning system.system.

  • PDF

Development of the Near Infrared Camera System for Astronomical Application

  • Moon, Bong-Kon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.39.2-39.2
    • /
    • 2010
  • In this paper, I present the domestic development of near infrared camera systems for the ground telescope and the space satellite. These systems are the first infrared instruments made for astronomical observation in Korea. KASINICS (KASI Near Infrared Camera System) was developed to be installed on the 1.8m telescope of the Bohyunsan Optical Astronomy Observatory (BOAO) in Korea. KASINICS is equipped with a $512{\times}512$ InSb array enable L band observations as well as J, H, and Ks bands. The field-of-view of the array is $3.3'{\times}3.3'$ with a resolution of 0.39"/pixel. It employs an Offner relay optical system providing a cold stop to eliminate thermal background emission from the telescope structures. From the test observation, limiting magnitudes are J=17.6, H=17.5, Ks=16.1 and L(narrow)=10.0 mag at a signal-to-noise ratio of 10 in an integration time of 100 s. MIRIS (Multi-purpose InfraRed Imaging System) is the main payload of the STSAT-3 in Korea. MIRIS Space Observation Camera (SOC) covers the observation wavelength from $0.9{\mu}m$ to $2.0{\mu}m$ with a wide field of view $3.67^{\circ}{\times}3.67^{\circ}$. The PICNIC HgCdTe detector in a cold box is cooled down below 100K by a micro Stirling cooler of which cooling capacity is 220mW at 77K. MIRIS SOC adopts passive cooling technique to chill the telescope below 200K by pointing to the deep space (3K). The cooling mechanism employs a radiator, a Winston cone baffle, a thermal shield, MLI of 30 layers, and GFRP pipe support in the system. Opto-mechanical analysis was made in order to estimate and compensate possible stresses from the thermal contraction of mounting parts at cryogenic temperatures. Finite Element Analysis (FEA) of mechanical structure was also conducted to ensure safety and stability in launching environments and in orbit. MIRIS SOC will mainly perform the Galactic plane survey with narrow band filters (Pa $\alpha$ and Pa $\alpha$ continuum) and CIB (Cosmic Infrared Background) observation with wide band filters (I and H) driven by a cryogenic stepping motor.

  • PDF

Selection of High Redshift Quasars with Infrared Medium-deep Survey

  • Jeon, Yi-Seul;Im, Myung-Shin;Park, Won-Kee;Kim, Ji-Hoon;Jun, Hyun-Sung;Choi, Chang-Su
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.77.2-77.2
    • /
    • 2010
  • A high redshift quasar is useful to investigate the early part of our universe. Since they are one of the brightest objects in the early universe, they can provide us with clues of the growth of super massive black holes and the early metal enrichment history. To discover the high redshift quasars, we designed a survey of wide area and moderate depth; Infrared Medium-deep Survey (IMS), a J-band imaging survey of ~200 $deg^2$ area where the multi-wavelength data sets exist. To obtain the J-band data, we are using the United Kingdom Infra-Red Telescope (UKIRT), and so far we have covered ~20 $deg^2$ with Y- or J-bands over three observing runs during 2009. We used color-color diagrams of multi-wavelength bands including i, z, Y, J, K, $3.6{\mu}m$ and $4.5{\mu}m$ to select high redshift quasars. The major challenge in the selection is many M/L/T dwarfs, low redshift galaxies, and instrumental defects that can be mistaken as a high redshift quasar. We describe how such contaminating sources can be excluded by adopting multiple color-color diagrams and eye-ball inspections. So far, our selection reveals two quasar candidates at z~7.

  • PDF

Current Status of the High Redshift Quasars Selection from Infrared Medium-deep Survey

  • Jeon, Yi-Seul;Im, Myung-Shin;Park, Won-Kee;Kim, Ji-Hoon;Jun, Hyun-Sung;Choi, Chang-Su
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.2
    • /
    • pp.37.1-37.1
    • /
    • 2010
  • A high redshift quasar is useful to investigate the early part of our universe. Since they are one of the brightest objects in the early universe, they can provide us with clues of the growth of super massive black holes and the early metal enrichment history. To discover the high redshift quasars, we designed a survey of wide area and moderate depth; Infrared Medium-deep Survey (IMS), a J-band imaging survey of ~200 deg2 area where the multi-wavelength data sets exist. To obtain the J-band data, we are using the United Kingdom Infra-Red Telescope (UKIRT), and so far we have covered~40 deg2 with Y- or J-bands over 36 observing nights. We used color-color diagrams of multi-wavelength bands including i, z, Y, J, K, $3.6{\mu}m$ and $4.5{\mu}m$ to select high redshift quasars. The major challenge in the selection is many M/L/T dwarfs, low redshift galaxies, and instrumental defects that can be mistaken as a high redshift quasar. We describe how such contaminating sources can be excluded by adopting multiple color-color diagrams and eye-ball inspections. So far, our selection reveals one quasar candidates at z~7 and a few candidates at z~6. In this poster presentation, we will update the current status of the quasar selection in the IMS fields.

  • PDF

MIRIS 우주관측 카메라 비행모델 Passive Cooling Test

  • Park, Yeong-Sik;Mun, Bong-Gon;Cha, Sang-Mok;Lee, Deok-Haeng;Lee, Dae-Hui;Han, Won-Yong;Jeong, Ung-Seop;Lee, Chang-Hui;Park, Seong-Jun;Nam, Uk-Won;Ga, Neung-Hyeon;Park, Jang-Hyeon;Lee, Seung-U;Matsumoto, Toshio
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.2
    • /
    • pp.56.1-56.1
    • /
    • 2010
  • MIRIS(Multipurpose InfraRed Imaging System)는 과학기술위성 3호의 주 탑재체로서 2011년 발사예정인 다목적 적외선 카메라 시스템이다. MIRIS는 우주관측 카메라와 지구관측 카메라로 구성되어 있으며, 우주관측 카메라는 $0.9-2.0{\mu}m$ 영역에서 3.67 deg. x 3.67 deg. FOV로 우리 은하평면 survey 관측과 우주배경복사(CIB) 관측을 수행할 것이다. 현재 MIRIS는 비행모델 개발 마무리 단계에 있으며, 검교정 시험, 열-진공 시험, 진동 시험 등을 수행하고 나면 2010년 말 위성 본체와의 조립을 진행할 것이다. 우주관측 카메라는 궤도상에서 태양, 지구의 적외선 복사와 망원경과 검출기 주변에서 발생하는 열잡음을 줄이기 위해 냉각이 필요하며, 제한된 위성의 무게와 부피, 전력등의 요구조건들 때문에 망원경 및 구조체의 복사냉각(Passive Cooling) 방법을 선택하였다. Passive cooling으로 우주관측 카메라의 망원경이 200K 이하로 냉각되면, dewar에 설치된 소형 냉각기를 가동하여 적외선 센서를 80K로 냉각한다. 위성체 내벽과 우주관측카메라의 각 구조체들 사이의 복사를 차단하기위해 30층의 MLI를 적용 하였고, 각 구조체들간의 열전도를 최소화하기위해 GFRP supporter를 적용하였다. 이 실험은 천문(연)에서 자체 제작한 열-진공 챔버를 활용하여 진행하였으며, 이미 인증모델에 대한 passive cooling 실험을 두 차례 실시하였고, 그 실험 결과를 반영하여 최종 비행모델에 대한 실험을 수행하였으며, 그 실험 결과에 대해 논의 하고자 한다.

  • PDF

Development of A Biotelemetry System for A Totally Implantable Artificial Heart (완전이식 인공심장용 무선정보 전송장치의 개발)

  • Choi, Won-Woo;Kang, Dong-Woo;Park, Seong-Keun;Choi Jae-Soon;Kim, Hee-Chan;Min, Byoung-Goo
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.1
    • /
    • pp.57-66
    • /
    • 1996
  • In this paper, a new biotelemetry system for a transcutaneous data communication between an implanted artificial heart with a control system and an external human-interfaced management system has been developed. A radio telemetry using radio frequency is a commonly used method in the conventional telemetry systems. But, it is not suitable for the medical applications because of not only an interference due to a radio broadcasting but also a harmfulness to the human body. In this paper, therefore, a new biotelemetry system applied to an artificial heart has been developed with the results of the recent research for an optical telemetry system based on the infrared light transmission with good skin permeability. The performance of the biotelemetry system developed has been assessed through mock circulatory experiments, and the clinical applicability has been also confirmed with the successful results in the animal experiments.

  • PDF