• 제목/요약/키워드: Information transmission

검색결과 9,151건 처리시간 0.036초

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

Helicobacter pylori 감염의 유병률과 관련요인에 관한 연구 (The Seroprevalence and Related Factors of Helicobacter pylori Infection)

  • 김영욱;이수일;조병만;고광욱;김영실;강수용;차애리;김돈균
    • Journal of Preventive Medicine and Public Health
    • /
    • 제29권3호
    • /
    • pp.669-678
    • /
    • 1996
  • Helicobacter pylori 감염은 만성 위염과 소화성 궤양의 원인인자로 작용하며 위암과도 강한 상관관계가 있는 것으로 증명되어 기존의 위 십이지장 질환의 치료와 관리에 많은 변화를 가져오고 있다. 저자들은 Helicobacter pylori 감염의 유병률을 측정하고 유병상태와 관련되는 요인을 조사할 목적으로 부산광역시와 경상남도에 거주하는 소아 몇 청년 552명을 대상으로 1996년 4월부터 6월에 걸쳐 본 연구를 시행했다. 연구 대상자들의 혈청에 존재하는 Helicobacter pylori Ig G 항체는 Enzyme Linked Immunosorbent Assay(ELISA) 방법으로 측정했으며 설문조사를 통해 기본적인 인구학적 특성, 유병상태와 관련되는 요인에 관한 정보를 얻었다. 연구 대상자들의 총 Helicobacter pylori 감염률은 25.7%였고 $1\sim3$세군에서의 5.8%에서 $20\sim29$세군의 44.4%까지 연령이 증가함에 따라 유병률도 비례해 증가하는 양상을 보였다($\chi^2$ for trend=57.9, p<0.0001). 특히 학동기 전 연령인 $4\sim6$세 군에서 초등학교 1, 2, 3학년 연령인 $7\sim9$세 군간에 유병률의 급격한 상승이 관찰되어 이 시기에 Helicobacter pylori 감염이 본격적으로 발생하는 것으로 추측된다. 다변량 로지스틱 회귀 모델에서 연령, 가족수 및 거주하는 주택의 형태가 유병상태와 유의한 상관관계를 보였으며 각각의 교차비(95% 신뢰구간)는 연령 $1\sim9$세를 기준으로 $10\sim19$$3.6(2.0\sim6.4)$, $20\sim29$$7.3(4.1\sim13.1)$ 였고, 가족수 $1\sim3$명을 기준으로 $4\sim5$$2.1(1.3\sim5.4)$, 6명 이상 $2.7(1.3\sim5.4)$였으며 주택의 형태는 아파트 거주를 기준으로 일반주택 및 연립주택 $1.9(1.1\sim3.5)$ 이었다.

  • PDF

퇴비에서 온도조건에 따른 Salmonella enterica와 Staphylococcus aureus의 내열성 변화 (Effect of Temperature on Survival of Salmonella enterica and Staphylococcus aureus)

  • 정규석;허성기;노은정;장미나;이동환;최재혁;이선영;윤종철;김계훈
    • 한국토양비료학회지
    • /
    • 제45권4호
    • /
    • pp.555-559
    • /
    • 2012
  • 본 연구는 국내에서 유통되는 가축분 퇴비를 대상으로 온도에 따른 병원성 미생물 (S. enterica, S. aureus)의 생존능 및 생존기간을 조사하고 농산물의 안전성을 확보하기 위하여 안전한 가축분 퇴비의 생산과 이용에 도움을 주고자 수행하였다. 국내 유통되는 가축분 퇴비에 S. enterica를 접종하여 온도에 따른 생존 변화양상을 조사한 결과, 처리온도에 따라서 다른 경향을 나타내었는데 $10^{\circ}C$에서 가장 오래 생존하였고, $55^{\circ}C$에서는 하루 만에 사멸하였다. 처리온도 $10^{\circ}C$에서 초기농도 $7.58log\;CFU\;g^{-1}$이었고 그 이후 점점 감소하기 시작하여 140일에는 $4.90log\;CFU\;g^{-1}$였는데 감소폭이 낮았다. 처리온도 $25^{\circ}C$에서 초기농도는 $7.83log\;CFU\;g^{-1}$이었고 0~60일까지는 급격히 감소하다가 그 이후로 거의 변화가 없었고 140일에는 모두 사멸하였다. $35^{\circ}C$에서는 0~20일까지 급격히 감소하였고 그 이후 60일 까지는 일정한 수준을 유지하다가 70일에 전부 사멸하였다. $55^{\circ}C$에서는 접종 1일 경과 후에 모두 사멸하였다. 생존기간은 처리온도 10, 25, 35, $55^{\circ}C$ 순이었는데 고온일수록 빨리 사멸하는 결과를 보였다. 가축분 퇴비 내 S. aureus의 생존변화를 실험한 결과, 처리온도 $10^{\circ}C$에서 초기농도 $7.87log\;CFU\;g^{-1}$이었고 그 이후 점점 감소하기 시작하여 90일에는 전부 사멸하였다. 처리온도 $25^{\circ}C$에서 초기농도는 $7.70log\;CFU\;g^{-1}$이었고 0~15일까지는 급격히 감소하다가 그 이후로 거의 변화가 없었으며 70일에는 모두 사멸하였다. $35^{\circ}C$에서는 0~7일까지 급격히 감소하였고 그 이후 35일까지는 약간 증가 후 감소하는 경향을 보였으며 40일 정도에 전부 사멸하였다. $55^{\circ}C$에서는 접종 1일 경과 후에 모두 사멸하였다. 생존기간은 처리온도 10, 25, 35, $55^{\circ}C$ 순이었는데 S. enterica와 비슷하게 온도가 높아질수록 사멸속도가 빨라지는 결과를 볼 수 있었다. 오염퇴비를 통해서 신선상태의 채소류 등에 전이가 될 경우는 식중독 사고의 잠정적인 위험인자가 될 수 있을 것이므로 퇴비제조 시 병원성 미생물이 사멸할 수 있는 부숙과정을 거치거나 부숙 후 퇴비의 위생적인 관리가 필요하다고 판단된다.

통시적 원형경관 해석을 통해 본 강진 백운동 원림의 복원 방향 (A Study on the Direction of Restoration for Baegun-dong Garden in Gangjin through a Diachronic Interpretation of the Prototype Scenery)

  • 하혜경;소현수
    • 한국조경학회지
    • /
    • 제45권3호
    • /
    • pp.116-128
    • /
    • 2017
  • 본 연구는 백운동 원림의 승경을 읊은 연작시(連作詩)로서 이담로(李聃老, 1627~1701)의 "백운동 8영", 송익휘(宋翼輝, 1701~?)의 "백운동 10수", 정약용(丁若鏞, 1762~1836)의 "백운동 12경"과 이시헌(李時憲, 1803~1860)의 "백운동 14경"에서 시원적 원형경관과 시대적 원형경관의 구성요소들을 추출, 통합하여 백운동 원림의 통시적 원형경관을 해석하였다. 이를 복원된 현장과 비교 분석한 후 향후 복원의 방향을 제안하였으며, 연구의 결과는 다음과 같다. 첫째, 백운동 원림의 통시적 원형경관은 옥판봉 아래 계곡에 별서를 만들고, 동백나무 숲길, 이담로의 '백운동' 바위글씨, 정약용이 붉은 글씨를 썼던 '창하벽', 폭포와 단풍나무숲, 오동나무가 어우러진 모습이었다. 별서 담장 밖에 홍매화숲, 소나무숲, 왕대나무숲이 있고, 옥판봉이 조망되는 정선대가 있었다. 별서 마당에는 취미선방, 죽각, 평상을 놓고, 연꽃이 심겨진 방지와 곡수거를 조성하였으며, 화계에 모란, 영산홍, 국화, 난초류, 수선화를 심고, 학을 키웠다. 둘째, 백운동 원림의 통시적 원형경관과 복원 현장을 비교한 결과, 백운동 계곡의 수원 확보, 죽각 복원과 '창하벽' 바위글씨의 각인 및 정선대에서 옥판봉을 조망할 수 있도록 수목 관리가 필요하다는 사실을 파악하였다. 더불어 홍매화, 소나무, 오동나무, 영산홍, 국화, 난초류, 수선화, 연꽃 등의 식재를 보강하여 다채로운 계절 경관을 제공하고, 효율적인 정보 전달을 위한 통합 안내시스템의 도입이 필요하다는 점을 제안하였다.

지상파 DMB를 이용한 클립캐스트 서비스 설계 및 구현 (Design and Implementation of Clipcast Service via Terrestrial DMB)

  • 조석현;서종수
    • 방송공학회논문지
    • /
    • 제16권1호
    • /
    • pp.23-32
    • /
    • 2011
  • 본 논문에서는 지상파 DMB를 이용하여 동영상, mp3, 텍스트, 정지영상 등 파일의 일부분인 클립을 전송하고 단말기에서 수신하는 클립캐스트 서비스를 위한 시스템 설계를 제안하고 구현하였다. 지상파 DMB 클립캐스트를 위해서는 데이터 채널의 별도 할당이 필요하며 이를 위해서는 기존 대역의 재조정이 필요하다. 클립캐스트는 지상파 DMB 시청이 적은 심야시간 (03:00~04:00)에 콘텐츠를 전송하며 비디오 서비스의 비트율을 352 Kbps로 낮추고 TPEG 서비스 대역을 이용하면 320 Kbps의 비트율로 클립캐스트 전송이 가능하다. 또한 단말기의 DMB 프로그램 구동을 위해 SMS(Short Message Service) 구동 방식과 EPG(Electronic Program Guide) 구동방식을 제안하였다. 클립캐스트 서비스는 멀티미디어 객체를 전송하는 MOT 프로토콜을 이용하며 파일의 안정적인 전송을 위하여 카루젤 형태로 2번 반복하여 전송한다. 이럴 경우 1시간 동안 전송 가능한 데이터 용량은 72 Mbyte로서, 500 Kbps급의 동영상을 시청할 경우 약 20분 정도의 동영상 서비스가 가능하다. 지상파 DMB 데이터 채널로 전송되는 클립을 표출할 때에는 CMS(Content Management Server)와 통신하여 각 클립의 길이에 대한 정보를 전달받은 후, 에러 없이 전송된 파일에 대해서만 표출해 준다. 각 콘텐츠는 사용자에게 미리보기 형식으로 제공이 가능하고 해당 콘텐츠 전체를 이용하기 위해서는 해당 콘텐츠에 할당된 URL로 접속하여 과금 과정을 거친 후 콘텐츠 다운로드가 가능하게 된다. 본 논문에서는 클립캐스트 서비스를 위한 지상파 DMB 시스템 설계를 제안하고 이를 구현함으로써 MediaFLO, DVB-H 등 타 모바일 방송에서 서비스하고 있는 파일 다운로드 서비스의 구현이 가능하게 되었다. 클립캐스트 서비스를 위한 단말기의 구동으로 타 모바일 방송에서는 EPG 구동 방식만 구현한데 비해 본 시스템에서는 EPG 보다 수신 신뢰성이 높은 SMS를 이용한 구동 방식을 제안함으로써 보다 안정된 서비스 제공이 가능하게 되었다. 이에 따라 클립캐스트 서비스에서 SMS와 EPG를 같이 이용하여 단말기를 구동시키는 하이브리드 구동 방식도 가능하게 되었다.

높은 LO-RF 격리 특성의 W-band MIMIC Single-balanced 믹서 (High LO-RF Isolation W-band MIMIC Single-balanced Mixer)

  • 안단;이복형;임병옥;이문교;이상진;진진만;고두현;김성찬;신동훈;박형무;박현창;김삼동;이진구
    • 대한전자공학회논문지TC
    • /
    • 제42권6호
    • /
    • pp.67-74
    • /
    • 2005
  • 본 논문에서는 branch line coupler과 $\lambda$/4 전송라인을 이용하여 W-band MIMIC(Millimeter-wave Monolithic Integrated Circuit) single-balanced 믹서를 설계 및 제작하였다. Single-balanced 믹서의 설계를 위해 branch line coupler와 $\lambda$/4 전송라인 이용한 94 GHz 발룬 회로를 설계하였으며, 시뮬레이션 결과 94 GHz에서 반사계수는 -27.9 dB를 얻었으며, coupling은 4.26 dB, thru 특성은 -3.77 dB의 결과를 얻었다. 격리도와 위상차는 94 GHz에서 각각 23.5 dB 및 $180.2^{\circ}$의 결과를 얻었다. MIMIC single-balanced 믹서는 0.1 $\mu$m InGaAs/InAlAs/GaAs Metamorphic HEMT (High Electron Mobility Transistor) 다이 오드를 이용하여 설계 및 제작되었다. 제작된 MHEMT는 fT는 189 GHz, fmax는 334 GHz의 양호한 성능을 나타내었다. 설계된 믹서는 본 연구에서 개발된 MHEMT MIMIC 공정을 이용해 제작되었다. 94 GHz MIMIC single-balanced 믹서의 측정결과 변환손실 특성은 94 GHz에서 23.1 dB의 특성을 나타내었으며, 입력 Pl dB는 10 dBm, 출력 Pl dB는 -13.9 dBm의 결과를 얻었다. Single-balanced 믹서의 LO-RF 격리도는 94.19 GHz에서 45.5 dB의 높은 LO-RF 격리도 특성을 나타내었다. 본 논문에서 설계 및 제작된 W-band MIMIC Single-balanced 믹서는 기존의 밀리미터파 대역 믹서와 비교하여 높은 LO-RF 격리도 특성을 나타내었다.

IC-임베디드 PCB 공정을 사용한 DVB-T/H SiP 설계 (Design of DVB-T/H SiP using IC-embedded PCB Process)

  • 이태헌;이장훈;윤영민;최석문;김창균;송인채;김부균;위재경
    • 대한전자공학회논문지SD
    • /
    • 제47권9호
    • /
    • pp.14-23
    • /
    • 2010
  • 본 논문에서는 유럽에서 사용되는 이동형 디지털 방송인 DVB-T/H 신호를 수신 및 신호처리 가능한 DVB-T/H SiP를 제작하였다. DVB-T/H SiP는 칩이 PCB 내부에 삽입될 수 있는 IC-임베디드 PCB 공정을 적용하여 설계되었다. DVB-T/H SiP에 삽입된 DVB-T/H IC는 신호를 수신하는 RF 칩과 어플리케이션 프로세서에서 활용할 수 있도록 수신된 신호를 변환하는 디지털 칩 2개를 원칩화한 모바일 TV용 SoC 이다. SiP 에는 DVB-T/H IC를 동작하기 위해 클럭소스로써 38.4MHz의 크리스탈을 이용하고, 전원공급을 위해 3MHz로 동작하는 DC-DC Converter와 LDO를 사용하였다. 제작된 DVB-T/H SiP는 $8mm{\times}8mm$ 의 4 Layer로 구성되었으며, IC-임베디드 PCB 기술을 사용하여 DVB-T/H IC는 2층과 3층에 배치시켰다. 시뮬레이션 결과 Ground Plane과 비아의 확보로 RF 신호선의 감도가 개선되었으며 SiP로 제작하는 경우에 Power 전달선에 존재하는 캐패시터와 인덕터의 조정이 필수적임을 확인하였다. 제작된 DVB-T/H SiP의 전력 소모는 평균 297mW이며 전력 효율은 87%로써 기존 모듈과 동등한 수준으로 구현되었고, 크기는 기존 모듈과 비교하여 70% 이상 감소하였다. 그러나 기존 모듈 대비평균 3.8dB의 수신 감도 하락이 나타났다. 이는 SiP에 존재하는 DC-DC Converter의 노이즈로 인한 2.8dB의 신호 감도 저하에 기인한 것이다.

출생 및 영아사망 신고체계 및 전산정보체계 개발 (Birth and Infant Death Reporting System via Computer Network)

  • 박정한;이영숙;이정애;조현;정영해;박순우;전혜리
    • 보건행정학회지
    • /
    • 제8권2호
    • /
    • pp.125-148
    • /
    • 1998
  • Accurate vital statistics are essential for a national health planning and evaluation. Among various vital statistics, birth and death rates, and infant and matemal mortality rates together with the causes of death are the very basic ones for above purposes as well as for the maternal and child health management. These statistics are based on the birth and death reports. It is required by law to report every birth and death within one month after its occurrence. However, in case of a neonatal death occurring prior to the birth report, most of the birth and death are not reported. Thus accurate infant and maternal mortality rates are not available yet in Korea. The main objective of this study is to develop a birth and infant death reporting system via computer network. We designed a new birth report form based on the current form and data from the analysis of medical record forms of 14 hospitals. A new form is basically addition of essential medical information to the current birth report form. Since a revision of the rules and regulations related wtih the birth report is necessary to use a new form, we kept the current from intact to make it acceptable to the government office for a field trial. We also developed computer programs for data input for birth and death reports at a medical faciltiy, data processing for production of maternal and child health indices at a health center, and management of maternal and child health services including immunization and postantal care at health center. The birth certificate and birth report can be printed out at a medical facility. The computer packages were programmed by Borland Delphi 3.0 and can be run under Windows 95 system. We proposed a new birth and death reporting system via computer network after a field trial for data input, transmission, and processing. The medical and demographic data o birth and death at medical facilities will be sent to health centers directly via computer network. The health center will retain the medical data for analysis and forward only the data for birth and death reports required by current regulations to the Dong, Up, or Myun Office. Once the birth or death is reported via computer network to the Dong Office, then the Dong Office will notify the baby's mother of the birth report and request to submit the baby's name by mail. When the baby's name its submitted. the Dong Office will forward the birth reports to the Common Court and Statistics Agency in the same way as the current system, Upon the completion of birth registration of the Common Court, the court will issue the birth certificate to mother which will be used in lieu of the family record. The advantages of proposed birth and death reporting system via computer network ar as follows ; I) The accuracy, timing, and completeness of reporting will be improved and more accurate maternal and child health indices can be obtained, ii) The maternal and child health services of health center will be obtained, iii) Epidemiologic data for pregnancy and birth can be obtained, iv) Manpower for birth and death reporting will be saved.

  • PDF

흰쥐의 삼차신경절에서 Transient receptor potential ankyrin 1 (TRPA1)의 발현 특성에 관한 연구 (Characterization of Trigeminal Ganglion Neurons Expressing Transient Receptor Potential Ankyrin 1 (TRPA1) in the Rat)

  • 백상규;나연경;김윤숙
    • Applied Microscopy
    • /
    • 제42권1호
    • /
    • pp.27-33
    • /
    • 2012
  • Transient receptor potential ankyrin 1 (TRPA1)은 $17^{\circ}C$보다 낮은 유해한 온도 및 자극적인 화합물에 의해 활성화되며 통각을 조절한다. 그러나 TRPA1에 의한 통각정보가 어떻게 처리되는지에 대한 정보는 많이 알려져 있지 않다. 본 연구에서는 흰쥐의 삼차신경절에서 TRPA1을 발현하는 신경세포의 특성을 규명하기 위해서, 면역형광기법을 사용하여 TRPA1을 발현하는 신경세포에서 다른 통각수용기들에서 발현되며, 특징적인 기능을 수행하는 수용기인 transient receptor potential vanilloid 1 (TRPV1)와 $P2X_3$와의 발현양상을 조사하였다. TRPA1을 발현하는 신경세포에서 열감각수용기이며, 통각표지자인 TRPV1과의 공존을 조사해 본 결과, TRPA1 면역양성 신경세포 중에서 58.8% (328/558)가 TRPV1을 동시에 발현하였으며, 41.2% (230/558)가 TRPA1만 발현하고 TRPV1을 발현하지 않았다. TRPA1을 발현하는 신경세포 중 TRPV1을 동시에 발현하는 신경세포는 대부분 작거나 중간크기였다. 또한 TRPA1과 조직의 손상, 그리고 염증 시 분비되는 ATP와 결합하는 $P2X_3$와의 공존을 조사해 본 결과, TRPA1 면역양성 신경세포 중에서 26.1% (310/1186)의 신경세포에서 $P2X_3$을 동시에 발현하였으며, 73.9% (876/1186)의 신경세포에서 TRPA1만 발현하였다. TRPA1을 발현하는 신경세포 중 $P2X_3$을 동시에 발현하는 신경세포는 대부분 작거나 중간크기였다. 이러한 결과는 TRPA1을 발현하는 신경세포가 TRPV1 또는 $P2X_3$를 동시에 발현함으로써 동일한 신경세포가 구강안면영역에서의 냉통각 및 열통각을 조절할 뿐 아니라, 냉통각 및 염증성동통을 동시에 전달하는 등 하나의 신경세포가 여러 가지 통각의 전달에 관여하는 것을 시사한다.

ALI 배양법 이용한 비강 점막 상피세포의 미세구조와 $^{14}C$-mannitol 투과도 (Ultra-Structures And $^{14}C$-Mannitol Transport Study of Human Nasal Epithelial Cells Using ALI Culture Technique)

  • 곽경록;황지윤;이지석;박혜경;김윤성;이민기;박순규;김유선;노환중
    • Tuberculosis and Respiratory Diseases
    • /
    • 제50권2호
    • /
    • pp.205-212
    • /
    • 2001
  • 연구배경 : 비강 점막을 통한 약물의 이동이나 대사 등은 실험 동물을 이용한 약력학적인 연구가 이루어져 왔으나 사람의 비강 점막 상피세포의 투과에 대한 연구는 없는 실정이다. 따라서 저자 등은 air-liquid interface (ALI) 방법으로 세포를 배양하여 그 미세구조와 in vitro에서 비강점막 상피세포에 대한 mannitol의 투과도를 알아보고자 하였다. 방 법 : 만성 부비동염 환자의 내시경을 이용한 부비동 수술시 정상 하비갑개의 조직을 채취하여 ALI 방법을 이용하여 transwell내에 monolayer로 상피세포를 배양하였으며 blank filter, 배양 5일째 및 7일째에 transepithelial electrical resistance (TEER) 값을 측정하고 투과전자현미경을 이용하여 견고연접(tight junction)의 형성을 확인하였다. 배양된 세포의 mannitol의 투과도를 알아보기 위해 12일째에 $^{14}C$가 부착된 mannitol $4{\mu}mol$을 배양액과 함께 투여하고 1시간 동안 10분 간격으로 % leakage를 측정하였다. 결 과 : 사람의 비강 상피세포는 7일 내에 confluent monolayer로 배양되었으며 투과전자현미경상 섬모와 견고 연접의 형성이 잘 관찰되었다. TEER 값은 blank filter는 $108.5\;ohm.cm^2$, 배양 5일째는 $141\;ohm.cm^2$, 배양 7일째는 $177.5\;ohm.cm^2$로 측정되었다. Mono-layer를 통한 $^{14}C$-mannitol의 % leakage는 10분, 20분, 30분, 40분, 50분, 60분에 각각 $35.67{\pm}5.43$, $34.42{\pm}5.60$, $32.75{\pm}5.71$, $31.76{\pm}4.22$, $30.96{\pm}3.49$, $29.60{\pm}3.68%$로 나타났다. 결 론 : ALI 방법으로 배양된 사람의 정상 비강점막 상피세포는 생체와 유사하게 배양되어 세포의 투과도(transcellular permeability) 를 알아보는데 적합하며 in vitro에서 비강점막을 통한 약물의 transport에 대한 연구에 도움이 될 것으로 생각된다.

  • PDF