• Title/Summary/Keyword: Influent sewage water

Search Result 86, Processing Time 0.023 seconds

The Development of An Environmentally Friendly Constructed Wetland System (친환경형 식물 정화조 시스템 개발)

  • Lee, Eun-Heui;Rhee, In-Sook;Jung, Dong-Sun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.7 no.4
    • /
    • pp.61-68
    • /
    • 2004
  • The purpose of this study was to develop environmentally friendly constructed wetland system in order to improve the environment. This system was constructed with two constructed wetlands andone pond. The size of the first and second wetland was 2.5m in length, 2.5m in width and 0.7m in depth for the first wetland and 0.6m in depth for the second wetland. Those were filled with pebbles with about 16~32mm in diameter from bottom to 20cm depth and onto the pebbles with about 0.5 mm in diameter sand in depth 40cm. The first constructed Wetland was planted with pragmites communis. The second was planted with Iris pseudoacorus and Acorus calamus var. aneustatus.A vertical flow system was used in the first constructed wetland and a horizontal flow system in the second. The water of outflow from the second wetland flowed into the pond. This system was installed in Yangpyeong, Kyunggi Province. The Quality of inflow and outflow were analyzed at the first time from May 20 to May 30, 2002 and at second time from June 10 to July 18, 2002. At the second period wetland was implanted with microbes in order to improve the efficiency of constructed wetlands. Following standard methods for wastewater, BOD, COD, SS, T-N and T-P were analyzed. This system was effective in reducing COD, BOD, SS, T-N and T-P level. The result shows that wastewater was purified through constructed wetland system with plants and highly purified with microbes especially in T-P. The Average total phosphorous concentration of influent and effluent in constructed wetland with microbes was 2.8mg/${\ell}$ L and 0.21mg/${\ell}$ respectively. This system can be used in rural community because this is not only effective on purification of sewage but also is harmonized with the surrounding nature.

Best Buffer Width of Riparian Buffer Zone using a Pilot with Different Plant Species for Reduction of Non-point Pollutant Loading (비점오염저감을 위한 수변완충지대의 적정 설계)

  • Kim, Sung-Won;Choi, I-Song;Oh, Jong-Min
    • Journal of Environmental Impact Assessment
    • /
    • v.17 no.1
    • /
    • pp.1-9
    • /
    • 2008
  • Non-point pollution is caused by many diffusive sources, unlike a point pollution derived from industrial wastewater treatment plants or sewage treatment plants. Runoff of non-point pollutants is originated from rainfall or thawing in short period of time moving over and through the a ground surface. They cause ill effect on the quality of neighboring aquatic environment. To prevent effectively the wash off from non-point pollutant, it should be immediately reduced at the source or be treated after gathering of runoff water. This study has been carried out for the best width of riparian buffer zone. So we implemented the experiment in terms of its depth, width and kind of vegetations and calculated the reduction of pollutants loading. The experimental zone encompasses the watershed of Namhan River (Kyunggido Yangpyunggun Byungsanri). The region was divided into 5 land cover sectors : grass, reed, pussy willow, mixed(grass+pussy willow) and natural zone to compare effectiveness of vegetation. Water samples from four points have been collected in different depths. And the pollutant removal efficiency by sectors with different plant species was yielded through influent with one of each sample. And we obtained the correlation between the width of riparian buffer zone and the removal efficiency of pollutants. Using correlation result, the width of riparian buffer zones which needs to improve the water quality of river could be derived.

The Effect of Sulfur/Limestone Ratio on the Efficiency of Sulfur-Utilizing Denitrification (황/석회석 충전비가 황-이용 탈질효율에 미치는 영향)

  • Shin, Hyung-Soon;Lee, Il-Su;Hwang, Yong-Yoo;Bae, Jae-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.14 no.3
    • /
    • pp.271-280
    • /
    • 2000
  • This study was conducted to determine the applicable loading rate and to evaluate the possibility of using limestones as an alkalinity source for the removal of ${NO_3}^{-}-N$ remaining after denitrification/nitrification process with the down-flow sulfur packed bed reactor(SPBR). The pretreated sewage was fed to SPBR. Three SPBRs were filled with elemental sulfur particles and limestones and the volumetric ratios of sulfur to limestone were 0%, 12.5% and 25% for R-0%, R-12.5% and R-25%, respectively. The applicable loading rate was evaluated increasing flow rate with influent ${NO_3}^{-}-N$ concentration of 20 mg/L. For R-0% with external alkalinity supply, denitrification efficiency was greater than 96% up to loading rate of $354.8g\;{NO_3}^{-}-N/m^3{\cdot}day$, and corresponding EBCT was 1.4hr. For R-12.5% and R-25%, where alkalinity was supplied by the limestone filled in the reactor, denitrification efficiency was greater than 94% up to loading rate of $283.8g\;{NO_3}^{-}-N/m^3{\cdot}day$, and corresponding EBCT was 1.7hr. The slightly better performance of R-12.5 compared to R-25 suggests that the volumetric sulfur to limestone ratio of 12.5% was enough for the supply of alkalinity required for sulfur-utilizing denitrification. DO was appeared not showing inhibitory effect on sulfur-utilizing denitrification. The clogging of SPBR caused by the produced gas can effectively be eliminated by regular introduction of treated water in up-flow mode.

  • PDF

Pollutant Removal in Variable HRT Using the Aerobic Biofilm (호기성 생물막을 이용한 HRT 변화에 따른 오염물질 제거)

  • Ahn, Kwang-Ho;Ko, Kwang-Baik;Kim, I-Tae;Kim, Kwang-Soo
    • Journal of Environmental Science International
    • /
    • v.21 no.12
    • /
    • pp.1495-1501
    • /
    • 2012
  • In this study, an experiment was conducted on influent water with low concentrations of organic matter, such as river water or secondary treatment water of a sewage treatment plant, according to HRT changes by using aerobic biofilm. In the biofilm process, as the biofilm increases in thickness, the inner membrane can be low in oxygen transfer rate and become anaerobic conditions, while the detachment of biomass from biofilm occurs. To overcome these limitations in the detachment of microorganisms in biofilm, the yarn, which was made from poly propylene(PP), was weaved and manufactured into a tube. Then, a test was carried out by injecting air so that the interior of the biofilm could create aerobic conditions. The results of the experiment showed that the removal efficiency of $TCOD_{cr}$ reached 66.1~81.2% by HRT 2hr, and 50.9 ~61.8% after HRT 1 hr. The removal efficiency of $SCOD_{cr}$ was 45.9 to 55.1% by HRT 1hr, and 26.1% in HRT 0.5hr, showing the highest removal efficiency in HRT 1hr. The SS removal efficiency was at 81.8 to 94.6%, and the effluent SS concentration was very low, indicating less than 2.2 mg/L in all HRT's. As a result, the $SCOD_{cr}$ and $NH_4{^+}$-N that were removed per specific surface area and attached to microbial biofilm showed the highest efficiency in HRT 1hr with 8.37 $gSCOD_{cr}/m^2{\cdot}d$, 2.93 $gNH_4{^+}-N/m^2{\cdot}d$. From the result of reviewing the characteristics of biofilm growth, microorganisms were found to be attached, and increased by 36 days. Later, they decreased in number through detachment, but showed a tendency to increase again 41 days later due to microbial reproduction.

Feasibility Study of Wetland-pond Systems for Water Quality Improvement and Agricultural Reuse (습지-연못 연계시스템에 의한 수질개선과 농업적 재이용 타당성 분석)

  • Jang, Jae-Ho;Jung, Kwang-Wook;Ham, Jong-Hwa;Yoon, Chun-Gyeong
    • Korean Journal of Ecology and Environment
    • /
    • v.37 no.3 s.108
    • /
    • pp.344-354
    • /
    • 2004
  • A pilot study was performed from September 2000 to April 2004 to examine the feasibility of the wetland-pond system for the agricultural reuse of reclaimed water. The wetland system was a subsurface flow type, with a hydraulic residence time of 3.5 days, and the subsequent pond was 8 $m^3$ in volume (2 m ${\times}$ 2 m ${\times}$ 2 m) and operated with intermittent-discharge and continuous flow types. The wetland system was effective in treating the sewage; median removal efficiencies of $BOD_5$ and TSS were above 70.0%, with mean effluent concentrations of 27.1 and 16.8 mg $L^{-1}$, respectively, for these constituents. However, they did often exceed the effluent water quality standards of 20 mg $L^{-1}$. Removal of T-N and T-P was relatively less effective and mean effluent concentrations were approximately 103.2 and 7.2 mg $L^{-1}$, respectively. The wetland system demonstrated high removal rate (92 ${\sim}$ 90%) of microorganisms, but effluent concentrations were in the range of 300 ${\sim}$ 16,000 MPN 100 $mL^{-1}$ which is still high for agricultural reuse. The subsequent pond system provided further treatment of the wetland effluent, and especially additional microorganisms removal in addition to wetland-pond system could reduce the mean concentration to 1,000 MPN 100 $mL^{-1}$ from about $10^5$ MPN 100 $mL^{-1}$ of wetland influent. Other parameters in the pond system showed seasonal variation, and the upper layer of the pond water column became remarkably clear immediately after ice melt. Overall, the wetland system was found to be adequate for treating sewage with stable removal efficiency, and the subsequent pond was effective for further polishing. This study concerned agricultural reuse of reclaimed water using natural systems. Considering stable performance and effective removal of bacterial indicators as well as other water quality parameters, low maintenance, and cost-effectiveness, wetland- pond system was thought to be an effective and feasible alternative for agricultural reuse of reclaimed water in rural area.

Factors Affecting Microbial Respiration (MR) by Rapid Oxygen Uptake Rate (OUR) Monitoring (급속 OUR 모니터링을 이용한 Microbial Respiration (MR) 영향인자 평가)

  • Park, Se-Yong;Mo, Kyung;Kim, Youn-Kwon;Kim, Moon-Il
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.9
    • /
    • pp.630-635
    • /
    • 2011
  • As this study was estimation of factors of rapid OUR (Oxygen Uptake Rate) monitoring method. Experiment for estimating factors of optimal microorganism activity was carried out in this study. In addition to comparison and estimation of SCOD variation by OUR variation using real wastewaters. In consequence OUR value was highest when F/M ratio, pH and temperature were 0.03~0.05, 6.0~8.5 and $20{\sim}30^{\circ}C$ respectively. Oxygen consumption by nitrification was incomplete. OUR variation of SCOD was recognizable difference of degradable rate at before and after of inflection point OUR. This study used an experimental method for real time prediction of the influent of the sewage treatment plant for optimal operation is expected to be able to do.

A Study on the Sludge-reduced Sewage Treatment Process Combined with Sludge Solubilization Technique Using Alkalophiles (호알칼리미생물을 이용한 슬러지감량형 하수처리공정 연구)

  • Shin, Kyung-Sook;Kim, Yoon-Seok;Han, Dae-Hoon;Han, Woon-Woo;Rhee, Young-Ha;Hur, Hyung-Woo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.6
    • /
    • pp.737-744
    • /
    • 2007
  • Recently, one of the most interesting topic in the field of wastewater treatment is the disposal of excess sludge. The new concept of excess sludge reduction with recirculation of solubilized sludge via effective microorganisms for cell disruption within the wastewater treatment process has been developed in this study. The alkalophiles for degradation of sludge cell wall were isolated as Exiguobacterium sp., which could be more effectively solubilized sludge in the anaerobic condition. The SCOD of solubilized excess sludge by Exiguobacterium sp. was up to about 2,000mg/L and average TN and TP concentration of solubilized component were 117mg/L and 58mg/L, respectively and C/N ratio was more than 17. To investigate the effects of solubilized sludge by alkalophiles on excess sludge reduction and nutrient removal efficiency, the pilot plant of $DF^{(S)}-MBR$ process, combined with membrane bioreactor and sludge solubilization tank, was operated. In the control run(without sludge solubilization), the daily sludge production was about 4.54 kgMLVSS/day. However, in the $DF^{(S)}-MBR$(with sludge solubilization), the daily sludge production was decreased to 1.39kgMLVSS/day. The effluent quality satisfied the effluent regulation in both cases. Furthermore, the $DF^{(S)}-MBR$ showed relatively better TN removal efficiency in spite of high influent loading. So we concluded that the solubilized excess sludge by alkalophiles was effectively degraded in the MBR process as the carbon source and 70% of sludge reduction efficiency can be achieved.

Identifying Cost and Benefit Items of Investment Projects to Offer New Public Services By the Use of Food Waste Disposers and the Direct Input of Feces in Sewers (주방오물분쇄기 사용 및 수세분뇨의 직투입에 따른 「새로운 공공하수도 서비스」제공을 위한 투자사업의 비용과 편익 항목 식별)

  • Oh, Hyun-Taek;Park, Kyoo-Hong;Kim, Sung Tai;Lim, Byung In
    • Journal of Convergence for Information Technology
    • /
    • v.10 no.5
    • /
    • pp.117-125
    • /
    • 2020
  • Our study identifies a cost and a benefit incurred in implementing an investment project to offer new public services by use of food waste disposers and direct input of feces in sewers. This is done with identifying costs of each processing division and benefits of the project by objective statistical data and engineering perspective. In summary, cost items identified are as follows: there are house laterals, removal of septic tanks, etc. for sewer pipes system. As to water quality conservation, cost incurs in storm water outfalls and divert chambers, sewage storage tanks, equipment to treat sewer overflows, and so on. With respect to sewage treatment plants(STPs), there are so many items as increase of contaminant loads in influent of STPs, and other items. There are benefit items in health improvement due to odor mitigation, increase of energy productivity, saving cost of food waste treatment and cleaning septic tanks, etc. These estimates will be used as a basic data for its economic effect.

Analysis of Water bady Damage at Osu Stream Using the Flow-Loading Equation and 8-Day Intervals Cumulative Flow Duration Curve (유량-부하량 관계식과 8일 간격 누적유량지속곡선을 이용한 오수천의 수체 손상도 분석)

  • Lee, Young Sung;Kim, Young Suk;Han, Sung Wook;Seo, kwon ok;Lim, chang bok;Lee, Yeong Jae;Kim, Kyunghyun;Jung, Kang-Young
    • Journal of Environmental Science International
    • /
    • v.27 no.12
    • /
    • pp.1179-1193
    • /
    • 2018
  • The purpose of this study at water quality pollutants to propose proper management method for the Osu-A unit watershed which is the influent tributary located upstream of the Sumjin -river among the 13 unit watersheds in the Sumjin-river water system. Analyzed the correlation between flow-pollution loading and the correlation between land use type, BOD and TP items, and analyzed 8-day intervals Cumulative Flow Duration Curve (CFDC) and Load Duration Curve (LDC) to evaluate water quality damage. As a result, both BOD and TP were larger than 1 and the concentration of water pollutants increased with increasing flow. BOD was positively correlated with Urban and Field, and TP was positively correlated with Field with 0.710. As a result of the LDC, BOD was analyzed that the target water quality was achieved with the excess rate of less than 50%, and TP exceeded the target water quality by 50.1%. BOD usually exceeded the standard value (exceedance probability 50%) at low flow zone and On the other hand, TP usually exceeded the standard value at high flow zone. Monthly BOD (April to June) and TP (May to August) exceeded the standard. Sewage Wastewater treatment and non-point pollution control is Osu-A unit watersheds are effective in improving BOD and TP.

Development of BNR(Biological Nutrient Removal) Process Using Expanded Polystylene(EPS) Media (Expanded Polystylene(EPS) 여재를 이용한 BNR(Biological Nutrient Removal) 공정 개발)

  • Ryu, Hong-Duck;Min, Kyung-Kook;Lee, Jeong-Hun;Choi, Kyoung-Young;Lim, Heun-Eun;Kim, Chul-Hwan;Lee, Sang-Ill
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.1
    • /
    • pp.1-6
    • /
    • 2006
  • Biological nutrient removal(BNR) process used in this study, which was packed with EPS(expanded polystylene) media, has more many advantages in aspect of reducing hydraulic retention time(HRT) of the process and having less effect of temperature in the winter season than commercial process in the present. Bench-scale study was performed using domestic wastewater. In the results, it was observed that the T-N removal efficiencies in HRT 6 hr and HRT 4 hr were 55% and 51%, respectively, showing the small reduction (about 4%) of T-N removal efficiency according to shortening of HRT. In comparison of T-N removal characteristic in summer and winter seasons, it showed that T-N removal efficiencies in summer and winter seasons were 65% and 54%, respectively, showing the 11% lower T-N removal efficiency in winter season than in summer season due to deterioration of nitrification in winter season. In the studies of influent loading rate and C/N ratio, the process showed stable effluent quality under the condition of broad influent loading rate and C/N ratio. Therefore, it is anticipated that the developed process in this study could be applicable to small wastewater treatment plant in nutrient removal.