Browse > Article
http://dx.doi.org/10.4491/KSEE.2011.33.9.630

Factors Affecting Microbial Respiration (MR) by Rapid Oxygen Uptake Rate (OUR) Monitoring  

Park, Se-Yong (Department of Civil and Environmental Engineering, Hanyang University)
Mo, Kyung (Department of Civil and Environmental Engineering, Hanyang University)
Kim, Youn-Kwon (K-water Institute, K-water)
Kim, Moon-Il (Department of Civil and Environmental Engineering, Hanyang University)
Publication Information
Abstract
As this study was estimation of factors of rapid OUR (Oxygen Uptake Rate) monitoring method. Experiment for estimating factors of optimal microorganism activity was carried out in this study. In addition to comparison and estimation of SCOD variation by OUR variation using real wastewaters. In consequence OUR value was highest when F/M ratio, pH and temperature were 0.03~0.05, 6.0~8.5 and $20{\sim}30^{\circ}C$ respectively. Oxygen consumption by nitrification was incomplete. OUR variation of SCOD was recognizable difference of degradable rate at before and after of inflection point OUR. This study used an experimental method for real time prediction of the influent of the sewage treatment plant for optimal operation is expected to be able to do.
Keywords
Rapid OUR (Oxygen Uptake Rate); Optimal Microorganism Activity; Factors;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 한국수자원공사, "자가진단형 하수처리장 운영관리시스템 (상용화버전)의 개발 및 실규모 하수처리장 현장적용 연구 (2차년도)," K-water 연구원(2009).
2 Spanjers, H., Takeks, I. and Brouwer, H., "Direct parameter extraction form respirograms for wastewater and biomass characterization", Water. Sci. Technol., 39(4), 137-145(1999).   DOI   ScienceOn
3 Wentzel, M. C., Mbewe, A. and Ekama G. A., "Batch test for measurment of readily biodegradable COD and active organism concentration in municipal wastewaters," Water SA., 21 (2), 117-124(1995).
4 정형석, "호흡률 측정법을 이용한 생물학적 질소 제거공정의 모니터링과 시뮬레이션," 한국과학기술원 석사학위 논문, pp. 1-5(2000).
5 Vanrolleghem, P. A., van Daele, M. and Dochin, D., "Preactical identifiability of a bioinetic model of activated sludge respiration," Water. Res. 29(11), 2561-2570(1997).
6 Sperandio Mathieu and Paul Etienne, "Estimation of wastewater biodegradable COD fraction by combing respirometric experiments in variors SO/XO ratios," Waste. Res., 34(4), 1233-1246(2000).
7 Cheryl, M. Kussow, Weichang Zhou, David, M. Gryte and Wei-Shou Hu, "Monitoring of mammalian cell growth and virus production process using on-line oxygen uptake rate measurement," Enzyme Microb. Technol., 17, 779-783(1995).   DOI   ScienceOn
8 Chudoba, P., Capdeville, B. and Chudoba, J., "Explanation of biological meaning of the So/Xo ratio in batch cultivation," Water. Sci. Technol., 26, 743-751(1992).
9 "Standard methods for the examination of water and wastewater," APHA, AWWA, WEF, 21th edition, Washington, D. C (2005).
10 김 철, "호흡도 기법을 통한 폐수내 COD 분율 예측," 한양대학교 석사학위 논문, pp. 28-33(2000).
11 성낙창 외, "폐수의 활성슬러지 처리," 신광문화사, p. 341 (2000).
12 Bruce, E. Rittmann, Perry, L. McCarty, "Environmental Biotechnology: Principles and Applications," Mcgraw-Hill, 324-326(2001).
13 Orhon, D. and Cokgor, E. U., "COD fractionation wastewater characterization-The state of the art," J. Chem. Technol. Biotechnol, 68, 283-293(1997).   DOI   ScienceOn
14 Henze, M., Gujer W., Mino, T. and van Loosdrecht M. C. M., "Activated sludge models ASM 1, ASM 2, ASM 2d, and ASM 3," IWA Scientific and Tech Report., No. 9(2000).
15 Chung, J. W., "Factors affecting nitroe accumulation and process optimization in a shortcut biological nitrogen removal hybrid reactor", ph. D. thesis. Hanyang University, Department of Civil and Environmental Engineering, Korea, pp. 225-231(2001).
16 김연권, 문용택, 김지연, 서인석, "pH 조절을 통한 폐활성 슬러지의 COD 가용화 및 감량화 평가," 상하수도학회지, 21(5), 551-558(2007).
17 Kim, Y. K., "Respirometric monitoring of microbial behavioral characteristics change through the retrofitting process," Ph. D. Thesis. Hanyang University, Department of Civil and Environmental Engineering, Korea, pp. 210-214(2003).