• Title/Summary/Keyword: Influent and effluent

Search Result 364, Processing Time 0.023 seconds

Assessment of Degradation Rate Coefficient and Temperature Correction Factor by Seasonal Variation of Concentration and Temperature in Livestock Wastewater Treatment in Field Scale (현장수준의 축산폐수처리에 있어서 계절별 농도 및 온도변화에 따른 분해반응계수 및 온도보정계수의 산정)

  • 박석환
    • Journal of Environmental Health Sciences
    • /
    • v.22 no.2
    • /
    • pp.90-95
    • /
    • 1996
  • This study was performed to calculate the degration rate coefficient, operating parameters to meet the effluent standards, and the temperature adjustment coefficients to each parameter of pollution by seasonal variation of concentration and temperature of influent in livestock wastewater treatment by sequencing batch reactor process in field scale. The followings are the conclusions that were derived from this study. 1. In the field, temperature of livestock wastewater in reactor was 20.3$\circ$C in summer and 6.0$\circ$C in winter. The ratio of BOD:TKN: T-P in influent was 100:80:7. BOD loadings in winter and spring were 0.26 and 0.43 kg $BOD/m^3$ day, respectively. Those in summer and fall were 0.25 and 0.13 kg $BOD/m^3$ day, respectively. 2. The degradation rate coefficient for TKN was larger in summer and fall in which temperature was high than that in which temperature was high than that in winter and spring in which concentration was high. On the contrary, the phosphorus uptake rate was larger in winter and spring than that in summer and fall. 3. The hydraulic retention time in winter and spring was longer than that in summer and fall. Especially, in order to meet the standard for TKN of 120 mg/l in winter in which temperature of wastewater was 6.0$\circ$C, as the MLSS concentration was increased from 4, 000 to 7, 000 mg/l, the hydraulic retention time was increased from 212 to 121 hours. But, in order to shorten that less than 121 hours for the economical wastewater treatment, countermeasure to increase temperature of wastewater in the reactor should be considered. 4. the temperature adjustment coefficients for BOD, $COD_{Mn}$, TKN and T-P were 1.0241, 1.0225, 1.0541 and 1.0495, respectively. Namely, the treatment of TKN was most sensitively affected by temperature. For the purpose of the effective removal of nitrogen and phosphorus which are sensitive to temperature, it is necessary to keep the temperature of livestock wastewater more than 20$\circ$C which is the temperature of it in summer.

  • PDF

Study on the applicability of the ozone / AOP and activated carbon process for the removal of trace organic contaminants and taste odor causing substances (미량오염물질 및 맛 냄새유발물질의 제거를 위한 오존/AOP 및 활성탄 공정의 적용성에 관한 연구)

  • Ha, Jeongtae;Im, Jiyeol;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.17 no.2
    • /
    • pp.155-162
    • /
    • 2015
  • This study was conducted to assess the removal characteristics of taste and odor causing compounds(2-MIB and geosmin) and micro organic matters. GAC and BAC process consisting of Ozone/AOP and activated carbon was applied. As a result, the influent concentration of 2-MIB 159 ng/L and geosmin 371 ng/L were removed 42% and 86% by ozone 1.0 mg/L, and 58%, 90% by AOP(ozone 1.0 mg/L + $H_2O_2$ 0.5 mg/L). Also it showed less than 2 ng/L effluent in GAC process and 99.8% removal efficiency in BAC process. Therefore, BAC process combining ozone/AOP and GAC is effective for persistent removal of micro organic matters, taste and odor. It is needed for optimization of Ozone/AOP process according to influent concentrations.

Status of Marine Environment of Olive Flounder, Paralichythys olivaceus, Culture Ground in Jeju-do - Focus on Kudoa septempunctata positive and negative farm - (제주도 육상 넙치양식장의 해양환경현황 - 쿠도아 양성양식장과 음성양식장을 중심으로 -)

  • OH, Hyun-Taik;YI, Yong-Min;CHO, Yun-Sik;KIM, Jin-Ho;LEE, Kyu-Hyun
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.28 no.3
    • /
    • pp.746-759
    • /
    • 2016
  • In this study, we monitored the status of marine environment of olive flounder, Paralichythys olivaceus, culture ground in Jeju-do, Republic of Korea. It reported the consumption of raw olive flounder meat containing of Kudoa, Kudoa septempunctata, could induce vomitting and diarrhea in Japan. The Kudoa is a new mycosporean species, researchers found Kudoa from the muscles of olive flounder cultured at western Japan and imported from Jeju-do. We choose two Kudoa positive farms and two negative farms in the mid of concern about the relation between Kudoa and habitat. We found two marine invasive species at the water-pumping seabed at one of the Kudoa positive farm. The concentration of pH and DO at on-growing flounder farms showed the decreasing pattern along side the raceway (influent sea waters > on growing sea waters > outfluent sea waters). The TN and TP values increased gradually following to the raceway (influent sea waters < on growing sea waters < outfluent sea waters). The concentration of COD and SS were in the range of $0.100-2.581mg{\cdot}L^{-1}$, $1.00-12.70mg{\cdot}L^{-1}$, respectively. The calculated residence time was 4hr 32minutes at F1, 11hr 21minutes at F2, and 9hr 50minutes at F3, respectively. It was calculated same distance of 4 km away from effluent pipes. Although direct relation between Kudoa and marine environment could not define well based on this study result, the more studies on marine environmental stressors for olive flounder are required to conduct as a reliable method including socio-economic group and environmental group.

Application of SBR Process to Treat Pickling Wastewater including the High Nitrate and Ca+2 (고농도 질산성질소와 Ca+2을 함유한 산세폐수의 효과적인 처리를 위한 SBR 공정의 적용)

  • Kim, Seung-jun;Choi, Yong-su;Bae, Woo-keun
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.2
    • /
    • pp.215-221
    • /
    • 2006
  • This research presents results from laboratory and pilot-scale experiments to remove high-nitrate in pickling wastewater using the sequencing batch reactor (SBR) as a biological method. During the experimental periods, the influent concentrations of NOx-N and $Ca^{+2}$ were analyzed to be 350-1,600 and 700-800 mg/L, respectively. In order to provide carbon source for denitrification, methanol has been added in proportion to the influent nitrate loading. The mean concentrations of MLSS and MLVSS, the fraction of volatile solids in sludge and the sludge volume index were measured to be 27 g/L, 5 g/L, 18.5% and 7.5, respectively. The solid retention time was kept in the range of 18 to 22 days, specific denitrification rate ($U_{dn}$) was $0.301g{NO_3}^--N/gVSS/day$. The oxidized nitrogen concentration of effluent ranged 2-34 mg/L with an average of 5.2 mg/L, the overall reduction in total nitrogen was more than 99.2%. In order to treat the pickling wastewater including the high concentration of nitrate and $Ca^{+2}$, the continuous flow process is not suitable because the specific gravity of the sludge is considerably increased by $Ca^{+2}$, thus the SBR process is shown to be very effective to treat the pickling wastewater.

Improvement of Single Anaerobic Reactor for Effective Nitrogen Removal (효율적 질소제거를 위한 단일 혐기성반응조의 개선)

  • 한동준;류재근;임연택;임재명
    • Journal of environmental and Sanitary engineering
    • /
    • v.12 no.3
    • /
    • pp.9-17
    • /
    • 1997
  • This research aims to remove nitrogen in the piggery wastewater by combined process with upflow anaerobic sludge blanket (UASB) and biofilm process. For the effective denitrification. anaerobic and anoxic reactors were connected to a reactor. The effluent of aerobix reactor was recycled equally with influent in the upper filter of anaerobic reactor for denitrification and outlet of UBF reactor was connected to the settling tank with $1.5{\;}{\ell}$ capacity and the settling sludge was repeatedly recycled to UASB zone. The organic loading rate of total reactor was operated from 0.4 to $3.1kgCOD/m^{3}/d$ and it was observed that the removal rate of TCOD was 80 to 95 percentage. Ammonia nitrogen was removed over 90 percentage in the less volumetric loading rate than $0.1{\;}kgN/m^{3}/d$. But because of non-limitation of organic materials, it was reduced to 70 percentage in the more volumetric loading rate than $0.6{\;}kgN/m^{3}/d$. But denitrification rate was observed 100 percentage in the all of loading rate. This is caused by the maintenance of optimum temperature, sufficient carbon source, and competition of electron acceptors. The results of COD mass balance at the $1.21{\;}kgCOD/m^{3}/d$ was observed with the 71.7% percentage of influent COD. It was revealed that the most part of organic materials was removed in the aerobic and the anaerobic reactor because 38.4 percentage was conversed into $CH_{4}$ gas and 11 percentage was removed in the aerobic reactor with cell synthesis and metabolism. Besides, 5.7% organics was used to denitrification reaction and 3.7% organics related to sulfate reduction.

  • PDF

Effect of Pollutant Loading and Flow Distance to Wastewater Treatment Efficiency in the Constructed Wetland System (오염부하량 및 유하거리가 인공습지에 의한 폐수처리 효율에 미치는 영향)

  • 김형중;김선주;윤춘경
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.39 no.5
    • /
    • pp.97-108
    • /
    • 1997
  • Natural wastewater treatment systems using the constructed wetland system were evaluated for the wastewater from the industrial complex in rural areas. For the treatment of wastewater from the industrial complex in rural area, a pilot plant of the constructed wetland system was installed at Baeksuk agri-industrial complex in ChunahnCity, Chunchungnam-Do. The experiment with this pilot plants was performed for 1996 and 1997. Results of the study were summarized as follows. For the BOD and COD, when the pollutant loading of them was about 1 3.8g/$m^2$. day (the concentration was l24.0mg/${\ell}$) arid 24.4g/$m^2$.day(the concentration was 220.Omg/${\ell}$), the removal rate of them was high, 90.2% and 93.4%, respectively. For the SS, the effluent concentration was consistently lower than the water quality standard even though the influent concentration varied significantly, which showed that SS was removed by the system effectively which consist of soil and plants. For the T-N and T-P, when the influent pollutant loading of them were moderately high, 2.8g/$m^2$.day to 7.4g/$m^2$. day(concentration 25.0mg/${\ell}$ to 49.7mg/${\ell}$) for T-N and 1.0g/$m^2$.day to 2.6g /$m^2$.day(concentration 8.6mg/${\ell}$ to 14.7mg/${\ell}$) for T-P, the removal rate of them were 86.5% and 94.0%, respectively. The removal rate by the flow distance increased rapidly in the first 4m from the inlet zone, and gradually there after. The width of system was 2m. Overall, the result showed that constructed wetland system is a feasible alternative for the treatment of wastewater from industrial complex in rural areas. Compared to existing systems, this system is quite competitive because it requires low capital cost, almost no energy and maintenance, and therefore, very cost effective.

  • PDF

The syudy of reaction kinetics in the thermophilic aerobic digestion process of piggery wastewater (축산폐수의 고온호기성 소화공정에서의 반응동력학 연구)

  • Kim, Yong-Kwan;Kim, Seok-Won;Kim, Baek-Jae
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2007.11a
    • /
    • pp.97-102
    • /
    • 2007
  • The piggery wastewater is the major source of the water pollution problem in the rural area. The treatment alternatives for piggery wastewater are limited by the characteristics of both high organic and nitrogen(N) content. In order to investigate an efficient N removal system, the thermophilic aerobic digestion process was examined. The experiment was investigated organic and nitrogen removal efficiency at various HRTs and air supply volume. The results of semi-continuous experiment indicated that a higher removal of the soluble portion of COD was achieved with the longer HRTs. However, the inert portion of COD in piggery wastewater was not much changed by thermophilic aerobic digestion. In addition, with the higher HRT of 3 days, up to 79% of NH4-N removal efficiency was achieved. Lower the HRTs, a decrease of NH4-N removal was founds. The gas samples from the lab reactor were analyzed along with the N content in influent and effluent. The N2O formation in our system indicates a novel aerobic deammonification process occurred during the thermophilic aerobic digestion. Both N02 and N03 were not presented in the effluent of thermophilic aerobic digester. With the HRT of 3 days, 36.4% of influent N(or 57.5% removal N) was aerobically converted to N2O gas. The ammonium conversion to N2O gas significantly decrease to 4.5% at low HRT of .05 day..

  • PDF

High-Rate Nitrogen Removal using a Submerged Module of Sulfur-Utilizing Denitrification (침지형 황 탈질 모듈을 이용한 고속의 질소제거)

  • Moon, Jin-Young;Hwang, Yong-Woo;Ga, Mi-Sun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.4
    • /
    • pp.429-437
    • /
    • 2007
  • This study aims to develop a sulfur-using denitrification process which is possible a renovation to advanced treatment plant submerging a simple module in activated sludge aeration tank. At first, the impact factor of sulfur-using denitrification was appreciated by the batch test. Secondly, reflecting a dissolved oxygen effect of sulfur-using denitrification that was confirmed by the batch test, in a continuous nitrification/sulfur-using denitrification, high-rate nitrogen removal reaction was induced at optimum condition controlling DO concentration according to phases. Also, inside and outside of sulfur-using denitrification module was covered with microfilter and the module was considered as an alternative of clarifier. Result of batch test for sulfur-using denitrification, $NO_2{^-}N$ was lower for consumption of alkalinity and sulfur than that of $NO_3{^-}-N$. These results revealed the accordance of theoretical prediction. In continuous nitrification/sulfur-using denitrification experiment, actual wastewater was used as a influent, and influent nitrogen loading rates were increased 0.04, 0.07, 0.11, $0.14kg\;N/m^3-day$ by changing hydraulic retention times. At this time, nitrogen loading rates of packed sulfur were increased 0.23, 0.46, 0.69, $0.93kg\;N/m^3-day$. As a result, nitrification efficiency was about 100% and denitrification efficiency was 93, 81, 79, 72%. Accordingly, nitrogen removal was a high-rate. Also the module of sulfur-using denitrification covered with microfilter did not make a fouling phenomena according to increased flux. And the module was achieved effluent suspended solids of below 10 mg/L without a clarifier. In conclusion, it is possible a renovation to advanced treatment plant submerging a simple module packed sulfur in activated sludge aeration tank of traditional facilities. And the plant used the module packed sulfur is expected as a effective facilities of high-rate and the smallest.

Performance Evaluation of Advanced Municipal Wastewater Tretment by Phased Isolation Intrachannel Clarifier Ditch (침전지내장형 상분리 산화구공정에 의한 하수 고도처리특성 평가)

  • Hong, Ki-Ho;Chang, Duk;Han, Sang-Bae
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.6
    • /
    • pp.563-570
    • /
    • 2004
  • Phased isolation intrachannel clarifier ditch process developed in this study is an enhanced biological nutrient removal process employing two ditches with intrachannel clarifiers. Bench-scale phased isolation ditch process was used to evaluate the system performance on municipal wastewater and detailed assessment of internal behavior in a ditch and each reactions. When the system was operated at the HRTs of 6~12hours, SRTs of 9~31 days, and cycle times of 4hours, the system showed removals of BOD, TN, and TP as high as 88~97%, 73~78%, and 65~90%, respectively. The internal behavior were well matched on each reactions such as nitrification, denitrification, and phosphorus release and uptake. As the SRT became longer, TN removal increased gradually, whereas TP removal decreased contrarily. However, the system was capable of producing an effluent TP concentration 1mg/L or less even at longer SRTs except the case of solids discharge by malfunction of intra-clarifier occurred by its geometrical limit. The system performance slightly decreased by hydraulic shock loading(increasing of influent flowrate and decreasing of system HRT). However, the higher system performance could be achieved again after four cycles. Thus, the system reliability could be successfully achieved short-term hydraulic shock loading that occurred in medium- and small-sized wastewater treatment plants suffering fluctuation of influent quality and flowrate during wet season.

A Study on the Behaviour of Organics and Nitrogen Using Upflow Anaerobic Reactor When Acid Fermenter is Added (상향류식 혐기성반응조와 산발효조의 병합처리시 유기물질과 질소거동에 관한 연구)

  • Oh, Dae-Min;Lee, Young-Shin
    • Journal of Environmental Science International
    • /
    • v.18 no.3
    • /
    • pp.325-331
    • /
    • 2009
  • This study was aimed to behaviour of organics and nitrogen on the upflow anaerobic reactor when a acid fermenter is added. Up flow anaerobic reactor (UAR) reaction will result which operates, COD removal efficiencies of reactor with nitrate loading rate 0.11, 0.66g/L/d were over 77%, but one with 1.0g/L/d was 73.5%. Especially, on NLR 0.11g/L/d, COD removal was 77% and nitrate removal efficiency was 93% simultaneously. The other side upflow anaerobic reactor and acid fermenter (UAR+AF) reaction will result witch operates, COD removal efficiencies of reactor with nitrate loading rate 0.11, 0.66g/L/d were over 85%, but one with 1.0g/L/d was 80%. Especially, on NLR 0.11g/L/d, COD removal was 85% and nitrate removal efficiency was 98% simultaneously. Also, without in reaction condition increase of influent nitrate concentration resulted in the linear decrease of nitrate removal efficiency and nitrate removal efficiency at influent nitrate-nitrogen 800mg/L was 50%. Alkalinity was increased theoretically by denitrification at low nitrate-N concentration, however, it was not increased theoretically at high nitrate-No 40% nitrate-N of UAR was denitrified until 70% height of reactor and 90% nitrate-N of UAR+AF was denitrified until 30% height of reactor Upflow anaerobic reactor was to occur accumulate acid, which TVA/Alkalinity is 0.3$\sim$0.47. Increase of NLR resulted increase of effluent alkalinity and TVA production