• 제목/요약/키워드: Influent and effluent

검색결과 364건 처리시간 0.023초

축산분뇨 혐기성 처리수에서 미세조류의 성장특성 (Characteristics of Microalgal Growth on Anaerobic Effluent of Animal Waste)

  • 임병란;이기세;노성유;박기영
    • 한국물환경학회지
    • /
    • 제24권3호
    • /
    • pp.306-310
    • /
    • 2008
  • Characteristics of microalgal growth was investigated using anaerobic effluent from two-phase animal waste digestor as substrate. Batch experiments were carried out to investigate the effect of the initial nitrogen and phosphorus concentrations on growth of Microcystis aeruginosa, Chlorella sp. and Euglena gracilis. In 400 times diluted anaerobic effluent (TN 3 mg/L), single cell growth of the Euglena gracilis population increased twice without delay, although Chlorella sp. and Microcystis aerugenos take over 144 hours. Similar appearance with single cell growth was observed in mixed cultures. However, microalgae population did not increase under condition of 10 times diluted influent (TP 3 mg/L) in both pure and mixed cultures, which was affected by high organic and nitrogen concentration. Logistic growth model successfully fitted to determine biokinetic parameters such as ${\lambda}$: lag time, ${\mu}m$: maximal specific growth rate, A: asymptote of growth.

철전기분해장치(FNR)에서 단위공정에 따른 질소와 인의 제거 (A Study on Phosphorus and Nitrogen Removal with Unit Operation in the Ferrous Nutrient Removal Process)

  • 김수복;김영규
    • 한국환경보건학회지
    • /
    • 제39권1호
    • /
    • pp.83-89
    • /
    • 2013
  • Objectives: The purpose of this experiment was to illuminate the relationship between the phosphorus removal rate of unit operation and the phosphorus removal rate of phosphorus volume loading in the Ferrous Nutrient Removal process, which consists of an anoxic basin, oxic basin, and iron precipitation apparatus. Methods: This study was conducted in order to improve the effect of nitrogen and phosphorus removal in domestic wastewater using the FNR (Ferrous Nutrient Removal) process which features an iron precipitation reactor in anoxic and oxic basins. The average concentration of TN and TP was analyzed in a pilot plant ($50m^3/day$). Results: The removal rate of T-N and T-P were 66.5% and 92.8%, respectively. The $NH_3-N$ concentration of effluent was 2.62 mg/l with nitrification in the oxic basin even though the influent was 17.7 mg/l. The $NO_3$-N concentration of effluent was 5.83 mg/l through nitrification in oxic basin even though the influent and anoxic basin were 0.82 mg/l and 1.00 mg/l, respectively. The specific nitrification of the oxic basin ($mg.NH_3$-Nremoved/gMLVSSd) was 16.5 and specific de-nitrification ($mg.NO_3$-Nremoved/gMLVSSd) was 90.8. The T-P removal rate was higher in the oxic basin as T-P of influent was consumed at a rate of 56.3% in the anoxic basin but at 90.3% in the oxic basin. The TP removal rate (mg.TP/g.MLSS.d) ranged from 2.01 to 4.67 (3.06) as the volume loading of T-P was increased, Conclusions: The test results showed that the electrolysis of iron is an effective method of phosphorus removal. Regardless of the temperature and organic matter content of the influent, the quality of phosphorus in the treated water was both relatively stable and high due to the high removal efficiency. Nitrogen removal efficiency was 66.5% because organic matter from the influent serves as a carbon source in the anoxic basin.

여과초기에서의 탈착된 입자의 거동 (Role of Detached Particles During Initial Filtration Phase)

  • 김자겸
    • 상하수도학회지
    • /
    • 제19권1호
    • /
    • pp.16-24
    • /
    • 2005
  • Mathematical model was developed to verify a sequential particle removal taking place in a granular media gravity filter. Consequential multi-layer filtration cycle model was applied to verify the fraction of filter effluent particles that are filter influent particles that were never removed as well as the fraction of filter effluent particles that were detached after deposition were performed through laboratory experiments. Three sizes of marker particles were injected ahead of the filter column as a pulse in the presence of four sizes of polystyrene particles that were used as a primary source of particles in the raw suspension to investigate particle attachment alone in contrast to net removal from attachment and detachment. Microscopic counting of filter effluent particles was assumed to reflect attachment. Experimental results indicated that particle detachment is significant beginning from the early phase of filtration. For each size of fluorescent microspheres at one filter depth, fluorescent microsphere removal increased with filter runtime to a maximum due to ripening. The detached fraction of effluent particles increased with particle size and filter depth. The presence of detached particles and the increasing fraction of detached particles in deeper bed were confirmed.

활성슬러지공정 하수종말처리장의 단위공정별 세균 제거효율 (Bacterial Removal Efficiencies by Unit Processes in a Sewage Treatment Plant using Activated Sludge Process)

  • 이동근;정미라;성기문;박성주
    • 한국물환경학회지
    • /
    • 제26권5호
    • /
    • pp.871-879
    • /
    • 2010
  • To figure out the removal efficiency of indicator and pathogenic bacteria by unit processes of a sewage treatment plant using activated sludge process, analyses were done for incoming sewage, influent and effluent of primary clarifier, aeration tank, secondary clarifier and final discharge conduit of the plant. A matrix of bacterial items (average of bacterial reduction [log/ml], p value of paired t-test, number of decreased cases of twenty analyses, removal percentage only for decreased cases) between incoming sewage and final effluent of the plant were heterotrophic plate counts (1.54, 0.000, 20, 95.01), total coliforms (1.38, 0.000, 19, 83.94), fecal coliforms (0.90, 0.000, 20, 94.84), fecal streptococci (0.90, 0.000, 20, 98.08), presumptive Salmonella (0.23, 0.561, 7, 99.09), and presumptive Shigella (1.02, 0.002, 15, 92.98). Total coliforms, fecal coliforms, heterotrophic plate counts, and fecal streptococci showed highest decrease through secondary clarifier about 1-log (p<0.001) between 88% and 96%, and primary clarifier represented the significant (p<0.05) decrease. However, final effluent through discharge conduit showed higher total coliforms and fecal streptococci than effluent of secondary clarifier (p<0.05). In addition, final effluent once violated the water quality standard while effluent of secondary clarifier satisfied the standard. Hence some control measures including elimination of deposits in discharge conduit or disinfection of final effluent are necessary.

우리나라 공공하수처리시설의 TOC 배출특성 및 관리방안 연구 (Characteristics of TOC in effluent discharge from public sewage treatment works in korea)

  • 정동환;최인철;조양석;안경희;정현미;권오상;박후원;신현상;허진
    • 상하수도학회지
    • /
    • 제28권6호
    • /
    • pp.657-668
    • /
    • 2014
  • Under Korea's Enforcement Decree of the Framework Act on Environmental Policy amended in 2013, total organic carbon (TOC) is newly added as water quality parameter to assess organic pollution in water and aquatic ecosystem. To meet the TOC requirement and improve quality of effluent discharged into public watershed, it is also necessary to develop standards for TOC in effluent from public sewage treatment works (PSTWs). In this study, we reviewed the characteristics and removal efficiency of TOC in influent and effluent of PSTWs. The study found that phosphorus treatment process removed not only soluble phosphorus but also a portion of TOC remaining after the secondary treatment process. TOC concentration in effluent from PSTWs operated in tandem with industrial wastewater treatment work was higher due to influx of insoluble substances from the industrial wastewater treatment work. In order to lay a foundation for the management of TOC from PSTWs, it is necessary to carry out research on TOC from different perspectives. For example, studies on the generation mechanism of TOC and the impact of TOC on drinking water resources, assessment of effluent qualities through monitoring, and development of measures to control TOC for the preservation of aquatic ecosystem are needed.

고도폐수처리장에서 원생동물을 이용한 수질예측 (Protozoa as an Indicator of Effluent Quality at Advanced Wastewater Treatment Plants)

  • 이찬형;문경숙;박상정;이은주;조재근;진익렬
    • 대한환경공학회지
    • /
    • 제28권4호
    • /
    • pp.389-396
    • /
    • 2006
  • 고도폐수처리장의 원생동물의 분포를 주별로 조사하였다. 통계방법을 이용하여 원생동물의 개체수와 운영조건, 유출수질을 분석하였다. 유입수의 성상과 처리장의 운영조건에 영향을 받아 처리장별로 원생동물 분포가 다르게 나타났다. 통계분석을 통해, 원생동물의 분포로 현재 운영중인 처리장의 운영조건을 알 수 있고 가까운 미래의 유출수질을 예측할 수 있었다. 처리장의 원생동물 분포, 유출수질, 운영조건 자료들이 충분히 확보되면 원생동물 관찰에 의해 처리장의 운영현황 및 가까운 미래의 수질예측이 가능해진다. 수질예측이 가능함으로 운영조건을 조기변동 하여 처리수질을 양호하게 유지할 수 있다. 장기적으로는 가장 좋은 유출수질때 나타나는 원생동물의 분포를 얻을 수 있도록 처리장의 운영조건을 변경함으로 좋은 유출수질을 얻을 수 있다.

SBR을 이용한 하수와 우사폐수로 구성된 혼합폐수의 영양소 제거 (The Nutrient Removal of Mixed Wastewater composed of Sewage and Stable Wastewater using SBR)

  • 김홍태
    • 한국환경과학회지
    • /
    • 제8권5호
    • /
    • pp.617-623
    • /
    • 1999
  • This study was carried out to obtain the optimal operating parameter on organic matters and nutrient removal of mixed wastewater which was composed of sewage and stable wastewater using SBR. A laboratory scale SBR was operated with An/Ae(Anaerobic/Aerobic) ratio of 3/3, 2/4 and 4/2(3.5/2.5) at organic loading rate of 0.14 to 0.27 kgBOD/$m^3$/d. TCOD/SCOD ratio of mixed wastewater was 3, so the important operating factor depended upon the resolving the particulate parts of wastewater. Conclusions of this study were as follows: 1) For mixed wastewater, BOD and COD removal efficiencies were 93-96% and 85-89%, respectively. It was not related to each organic loading rate, whereas depended on An/Ae ratio. During Anarobic period, the amount of SCOD consumption was very little, because ICOD in influent was converted to SCOD by hydrolysis of insoluble matter. 2) T-N removal efficiencies of mixed wastewater were 55-62% for Exp. 1, 66-76% for Exp. 2, and 67-81% for Exp. 3, respectively. It was found that nitrification rate was increased according to organic concentration in influent increased. Therefore, the nitrification rate seemed to be achieved by heterotrophs. During anoxic period, denitrification rate depended on SCOD concentration in aerobic period and thus, was not resulted by endogenous denitrification. However, the amount of denitrification during anaerobic period were 3.5-14.1 mg/cycle, and that of BOD consumed were 10-40 mg/cycle. 3) For P removal of mixed wastewater, EBPR appeared only Mode 3($3^*$). It was found that the time in which ICOD was converted to VFA should be sufficient. For mode 3 in each Exp., P removal efficiencies were 74, 87, and 81%, respectively. But for 45-48 of COD/TP ratio in influent, P concentration in effluent was over 1 mg/L. It was caused to a large amount of ICOD in influent. However, as P concnetration in influent was increased, the amounts of P release and uptake were increased linearly.

  • PDF

습식 사이클론을 이용한 하수슬러지내 무기성분 및 MAP 분리 (Separation of Inorganic Sludge and MAP from Municipal Wastewater Sludge Using Hydrocyclone)

  • 이동우;배강형;조건상;김성홍
    • 상하수도학회지
    • /
    • 제28권1호
    • /
    • pp.135-142
    • /
    • 2014
  • The performance of inorganic sludge separation system is evaluated. Anaerobic digester effluent sludge is used for feed sludge of this system and hydrocyclone is used for inorganic sludge separation. For phosphorus removal and recovery $MgCl_2$ is pumped into MAP growth tank, a component of inorganic sludge separation system. Using this system inorganic sludge which contained less than 40 % of organic matter can be discharged stably and the maximum amount of separated inorganic sludge is 13.4 % of influent sludge based on dry solid. The amount of phosphorus recovered as MAP(as P) is 16.7 % to influent T-P.

인공습지 실험시설의 5년간 결과 및 고찰(지역환경 \circled3) (Review of 5-year Experimental Data from Treatment Wetland)

  • 김민희;윤춘경
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2000년도 학술발표회 발표논문집
    • /
    • pp.649-654
    • /
    • 2000
  • Field experiment was performed from August 1996 to June 2000. The pilot plant was installed in Konkuk University and the effluent from septic tank of school building was used as an influent to the treatment basin. The treatment basin was composed of sand and reed. Average removal rate of BOD, SS was about 75.9%, 73.4%, respectively. T-P removal rate was about 47.3%, and T-N removal rate was 19.6%. The reason for poor T-N removal might be due to high influent concentration and short retention times. As operation period increased, BOD removal rates were increased, and SS and T-P removal rates did not change significantly, but T-N removal rates were decreased.

  • PDF

역 유동층 생물막 반응기에서 액체순환속도가 생물막에 미치는 영향 (Effect of the Liquid Circulation Velocity on the Biofilm Development in an IFBBR)

  • 김동석;윤준영
    • 한국환경과학회지
    • /
    • 제3권1호
    • /
    • pp.49-56
    • /
    • 1994
  • Effect of the liquid circulation velocity on the biofilm development was investigated in an inverse fluidized bed biofilm reactor(IFBBR). To observe the effect of the influent COD concentration on biofilm simultaneously, the influent COD value was adjusted to 1000mg/1 f for 1st reactor, and 2500mg/l for 2nd reactor. The liquid circulation velocity was adjusted by controlling the initial liquid height. As the liquid circulation velocity was decreased, the settling amount of biomass was increased and the amount of effluent biomass was decreased. Since the friction of liquid was decreased by the decrease of liquid circulation velocity, the biofilm thickness was increased and the biofilm dry density was decreased. In the 1st reactor the SCOD removal efficiency was constant regardless of the variation of the liquid circulation velocity, but it was increased by the decrease of the liquid circulation velocity because of more biomass population in 2nd reactor.

  • PDF