• Title/Summary/Keyword: Influent

Search Result 842, Processing Time 0.032 seconds

A Study on the Treatment Efficiency of Sequencing Batch Reactor with the Livestock Nightsoil Organic Loading Rate Variance (가축분뇨 유기물질부가별 연속회분식반응조 효율에 관한 연구)

  • 여운호
    • Journal of Environmental Health Sciences
    • /
    • v.21 no.4
    • /
    • pp.32-36
    • /
    • 1995
  • This study was carried out to investigate the treatment efficiency of sequencing batch reactor when the livestock nightsoil organic loading rate was varied. Sequencing batch reactor was operated with the variance of influent BOD concentration and operating cycle. The average influent BOD concentrations in this study were 150 mg/l, 200 mg/l, 250 mg/l, 300 mg/l, 350 mg/l, 400 mg/l, 450 mg/l and 500 mg/l in the condition of 1~3 cycles/day. The treatment efficiency of sequencing batch reactor is good at the volumetric loading of 0.05~0.20 kg $BOD/m^3\cdot day$. Therefore, sequencing batch reactor process would become an effective alternative for the process of small scale livestock nightsoil treatment plants.

  • PDF

HRT and Influent Concentration Effects on Swine Wastewater Treatment Using UASB (UASB의 HRT와 원수의 농도가 양돈폐수 처리에 미치는 영향 연구)

  • Park, Jong-Hoon;Kang, Seon-Hong
    • Journal of Korean Society on Water Environment
    • /
    • v.18 no.4
    • /
    • pp.365-370
    • /
    • 2002
  • This study aims to study the effect of HRT and influent concentration on swine wastewater treatment using UASB(Upflow Anaerobic Sludge Blanket). Sample was separately collected from the piggery farm; urine(liquid part) and solid part to compare their treatment characteristics. Reactors were used two UASB(3.2 L) in this research under constant temperature ($35^{\circ}C$). Their operating conditions were as follows; Run 1(UASB ; HRT 6-days, 1 cycle/d), Run 2(UASB ; HRT 3-days, 1 cycle/d). Biogas was collected and analyzed using GC(HP-6890). By comparing the results of Run 1 and Run 2, the effect of HRT was investigated. The treatment efficiency of Run 1 which had longer HRT was higher than that of Run 2 in both solid and liquid parts of piggery sample. Methane content in collected biogas is more than 80%.

Study on the Characteristics of Nitrification and Denitrification using Attached Microorganism (부착성 미생물을 이용한 질산화 및 탈질특성에 관한 연구)

  • Kwon, Moonsun;Lee, Euisin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.8 no.3
    • /
    • pp.19-25
    • /
    • 1994
  • In this research, characteristics of nitrification and denitrification using the microorganism attached on sponge and plates were examined. The denitrification and nitrification performance were investigated under the anaerobic and aerobic condition for about 2 months. Because the basins of denitrification and nitrification were connected in series, wastewater was flowed from denitrification basin to nitrification one. The 90% of influent flowrate was returned from nitrification basin to denitrification one. Most of organic material was removed in nitrification basin, wherease the only exact amount of organics required in denitrification process was removed in denitrification one. This experiment resulted in that heterotrophic bacteria existing in aerobic basin governed the removal efficiency of organic compounds. In case the influent BOD concentration into nitrification basin was 80mg/l, it did not affect to accumulation of nitrifying bacteria, the balance of heterotrophic bacteria was proved to be an important factor in nitrification/denitrification method such as anaerobic and aerobic cycling type.

  • PDF

Separation of Inorganic Sludge and MAP from Municipal Wastewater Sludge Using Hydrocyclone (습식 사이클론을 이용한 하수슬러지내 무기성분 및 MAP 분리)

  • Lee, Dong-Woo;Bae, Kang-Hyeong;Cho, Kun-Sang;Kim, Sung-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.1
    • /
    • pp.135-142
    • /
    • 2014
  • The performance of inorganic sludge separation system is evaluated. Anaerobic digester effluent sludge is used for feed sludge of this system and hydrocyclone is used for inorganic sludge separation. For phosphorus removal and recovery $MgCl_2$ is pumped into MAP growth tank, a component of inorganic sludge separation system. Using this system inorganic sludge which contained less than 40 % of organic matter can be discharged stably and the maximum amount of separated inorganic sludge is 13.4 % of influent sludge based on dry solid. The amount of phosphorus recovered as MAP(as P) is 16.7 % to influent T-P.

고정화 질화세균을 이용한 저농도 암모니아의 고도처리 (II) 초기 암모니아 농도, 온도 그리고 pH의 영향

  • Lee, Jeong-Hun;Kim, Byeong-Jin;Lee, Min-Su;Na, In-Geol;Seo, Geun-Hak
    • 한국생물공학회:학술대회논문집
    • /
    • 2002.04a
    • /
    • pp.346-348
    • /
    • 2002
  • This study estimated the effect of influent TAN concentration. temperature and pH in the airlift bioreactor(aeration rate; 1.5 vvm, HRT 0.35hr) using immobilized nitrifiers by PVA. At the effect of influent TAN concentration, removal rate was increased with increasing it and removal efficiency maintained 93${\pm}$2%. The optimum temperature for nitrification was $30^{\circ}C$ and at this point. removal efficiency was 95.5${\pm}$1.5%. It was effective to nitrify at $10^{\circ}C$ of low temperature. In the pH range from 7 to 9 in the bioreactor. removal rate and removal efficiency was 310${\pm}$10 $g/m^3$ day and 94${\pm}$3%.

  • PDF

Assessment of Free Water Surface Constructed Wetland Design Parameters for the Reduction of Agricultural Nonpoint Source Pollution (농업유역 비점원오염 저감을 위한 자유수면형 인공습지 설계인자 평가)

  • Jang, Jeong-Ryeol;Kwun, Soon-Kuk;Choi, Sun-Hwa
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2005.10a
    • /
    • pp.637-642
    • /
    • 2005
  • The objective of this study is to evaluate design parameters of free water surface constructed wetland for the reduction of agricultural nonpoint source pollution. From literature review, the key design parameters were selected as influent concentration, influent water volume, hydraulic retention time and wetland system arrangement. The design value for each parameter was established after pilot study. Full-scale constructed wetland on the basis of the designed values was constructed to evaluate those reasonableness. The results of this study showed that the designed values for free water surface constructed wetland were appropriate for the reduction of agricultural nonpoint source pollution.

  • PDF

Review of 5-year Experimental Data from Treatment Wetland (인공습지 실험시설의 5년간 결과 및 고찰(지역환경 \circled3))

  • 김민희;윤춘경
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.649-654
    • /
    • 2000
  • Field experiment was performed from August 1996 to June 2000. The pilot plant was installed in Konkuk University and the effluent from septic tank of school building was used as an influent to the treatment basin. The treatment basin was composed of sand and reed. Average removal rate of BOD, SS was about 75.9%, 73.4%, respectively. T-P removal rate was about 47.3%, and T-N removal rate was 19.6%. The reason for poor T-N removal might be due to high influent concentration and short retention times. As operation period increased, BOD removal rates were increased, and SS and T-P removal rates did not change significantly, but T-N removal rates were decreased.

  • PDF

Safety Investigation of Tap Water and Biofilm by Isolated Bacteria (수돗물과 생물막의 세균분포를 통한 안전성 조사)

  • Lee, Dong-Geun
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.3
    • /
    • pp.207-213
    • /
    • 2004
  • For investigation of the food safety and influence of biofilm on the bacterial quality of tap water, it was detected by selective media, and identified by API kit and MIDI system. Biofilm and effluent showed much more colonies than influent. Although there were many presumptive positive colonies, no pathogenic bacterium detected. However opportunistic pathogens, such as Pseudomonas aeruginosa and Aeromonas species, and members of family Enterobacteriaceae were detected. Compared to influent, biofilm and effluent showed more diverse bacteria. This study implies that there would be the negative influence of biofilm on the bacterial qualities of tap water.

Automatic Addition Control of the External Carbon Source by the Measurement of ORP in Biological Nitrogen Removal Process (생물학적 질소 제거공정에서 ORP 측정을 통한 외부탄소원의 자동 주입 제어)

  • Shin, Choon-Hwan
    • Journal of Environmental Science International
    • /
    • v.21 no.3
    • /
    • pp.383-390
    • /
    • 2012
  • For the cost-effective biological nitrogen removal (BNR) process whose characteristics of influent have low COD/N ratios, the automatic control system for the addition of external carbon based on oxidation-reduction potential (ORP) data in an anoxic reactor has been developed. In this study, it was carried out with a pilot-scale Bardenpho process which was consisted of anoxic 1, aerobic 1, aerobic 2, anoxic 2, aerobic 3 tank and clarifier. Firstly, the correlation coefficient ($R^2$) of the dosage of external carbon source and ORP value was about 0.97. Consequently, the automatic control system using ORP showed that the dosage of external carbon source was decreased by about 20% compared with a stable dosage of 75 mg/L based on the COD/N ratio of the anoxic influent.

Performance of Microbial Fuel Cell Integrated with Anaerobic Membrane Filter for Continuous Sewage Treatment with Stable Effluent Quality (안정적 유출수질의 연속 하수처리를 위한 혐기성 멤브레인 필터와 통합된 미생물연료전지의 성능 평가)

  • Lee, Yunhee;Oa, Seong-Wook
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.6
    • /
    • pp.808-812
    • /
    • 2013
  • A new type of microbial fuel cell (MFC) with anaerobic membrane filter was designed to produce bioelectricity and to treat domestic sewage at relatively high organic loading rate (OLR) of $6.25kgCOD/m^3/day$ and short hydraulic retention time (HRT) of 1.9 h. A following aeration system was applied to ensure effluent water quality in continuous operation. Glucose was supplemented to increase the influent concentration of domestic sewage. Influent substrate of 95% was removed via the MFC and following aeration system and the corresponding maximum power density was $25.6mW/m^3$. External resistor of $200{\Omega}$ and air-cathode system contributed better MFC performance comparing to $2000{\Omega}$ and dissolved oxygen as a catholyte.