• 제목/요약/키워드: Inflow of groundwater

검색결과 156건 처리시간 0.024초

터널내 구간별 지하수 유입량 산정방법 : 유속계의 이용 (Calcu;ation of Groundwater Inflow Rates with respect to the Subusection of Tunnel: Application of the Current Meter)

  • 조병욱
    • 자원환경지질
    • /
    • 제32권6호
    • /
    • pp.661-667
    • /
    • 1999
  • Estimation of inflow rates into subsection of a tunnel is establishing the proposed grouting part, measuring the degree of grouting, and settling the dispute over deplrtion of groundwater which may be resulted from tunneling. A current meter was used to calculate inflow rates of groundwater to each subsection of the tunnel. The study area is composed of section 1 and 2 of Imha-Youngchun waterway trnnel which has 32.976km length, with each section having 3,745m and 4,079m, respectively. The depth from groung surface to tunnel ranges from 122.45m to 358.3m. Total inflow rates of groundwater into each section measured three times by the current meter, together with bottle and eye measurement, were compared with groundwater inflow rates of each section measured by datalogger. The calcuated inflow rates of the sections by bottle and eye measurement were 8.8%∼54.7% of inflow rate (averaging 27,4%), whwewas those by the current meter were 76.9%∼110.6%(averaging 92.9%). Therfore, the current meter is regarded as useful method to calculate groundwater inflow rates into subsections of a tunnel.

  • PDF

Change of groundwater inflow by cutoff grouting thickness and permeability coefficient

  • Kim, Youngsang;Moon, Joon-Shik
    • Geomechanics and Engineering
    • /
    • 제21권2호
    • /
    • pp.165-170
    • /
    • 2020
  • The groundwater during tunnel excavation not only affects the stability of the tunnel and constructability but also causes the subsidence of the upper ground due to the lowering of groundwater. Generally, the cutoff grouting is applied as a countermeasure to reduce the groundwater inflow during tunnel excavation, and the cutoff grouting is often applied in the range of plastic zone around the tunnel. However, grouting in the plastic zone is only appropriate for ground reinforcement purposes, and guidelines for the application range of cutoff grouting and the targeted permeability coefficient of the grouting zone are required. In this study, the relationship between groundwater inflow into tunnel and application range of cutoff grouting and permeability coefficient is proposed and compared with numerical analysis results. It was found that grouting with tunnel radius thickness is appropriate to reduce the groundwater inflows effectively. More than 90% reduction in groundwater inflow can be achieved when the annular area of the tunnel radius thickness is grouted with a permeability reduction ratio of 1/50~1/200.

Correlation analysis and time series analysis of Ground-water inflow rate into tunnel of Seoul subway system

  • 김성준;이강근;염병우
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 추계학술발표회
    • /
    • pp.254-257
    • /
    • 2003
  • Statistical analysis is performed to estimate the correlations between geological or geographical factor and groundwater inflow rates in the Seoul subway system. Correlation analysis shows that among several geological and geographical factors fractures and streams have most strong effects on inflow rate into tunnels. In particular, subway line 5∼8 are affected more by these factors than subway line 1∼4. Time series analysis is carried out to forecast groundwater inflow rate. Time series analysis is a useful empirical method for simulation and forecasts in case that physical model can not be applied to. The time series of groundwater inflow rates is calculated using the observation data. Transfer function-noise model is applied with the precipitation data as input variables. For time series analysis, statistical methods are performed to identify proper model and autoregressive-moving average models are applied to evaluation of inflow rate. Each model is identified to satisfy the lowest value of information criteria. Results show that the values by result equations are well fitted with the actual inflow rate values. The selected models could give a good explanation of inflow rates variation into subway tunnels.

  • PDF

도시지역의 지하수수지 (Groundwater Balance in Urban Area)

  • 이승현;배상근
    • 한국환경과학회지
    • /
    • 제20권12호
    • /
    • pp.1553-1560
    • /
    • 2011
  • The study analyzes groundwater balance with regard to the water recharge and discharge which contain urbanization components in Suyeong-gu, Busan. It also verifies the reliability and accuracy improvement on the analysis of the balance. The result of the study is viewed as preliminary data which are useful to develop, utilize and manage groundwater. The average quantity of groundwater recharge is 6,014.1 $m^3$/day in the research area during the last ten year period(from 1998 to 2007). The outflow from drainage areas to rivers and coasts is 149.3 $m^3$/day, the inflow from rivers and coasts to drainage area is 439.9 $m^3$/day. The use of the water is 4,243.0 $m^3$/day. The outflow caused by subway in line No.2 and No.3 through Suyeong-gu and the one by building an underground electric complex is 1,500.0 $m^3$/day. The leakage of water works is 6514.9 $m^3$/day. The inflow and outflow of sewerage is 5082.2 $m^3$/day from groundwater to sewer. The amount of groundwater recharge, the inflow from rivers and coasts to drainage area, and the leakage of water works belong to the amount of groundwater inflow and the total amount is 12,968.9 $m^3$/day. The amount of outflow from drainage area to rivers and coasts, the use of groundwater, outflow by subway and underground electric complex tunnel and the amount of inflow of the water to sewerage belong to the amount of outflow of groundwater and the sum amount is 13,031.5 $m^3$/day. The gap between the amount of inflow and outflow of groundwater is 62.6 $m^3$/day, which is considered to reflect the trend that the short term drop in the amount of rainfall results in the amount of groundwater recharge and that the amount of outflow from drainage area to rivers and coasts decreases.

수리지화학적 추적자(222Rn, 주요용존이온)와 미생물 군집 분석을 통한 도심 지역 하천에서의 지하수 유출 특성 평가 (Determining Characteristics of Groundwater Inflow to the Stream in an Urban Area using Hydrogeochemical Tracers (222Rn and Major Dissolved Ions) and Microbial Community Analysis)

  • 오용화;김동훈;이수형;문희선;조수영
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제25권2호
    • /
    • pp.16-23
    • /
    • 2020
  • In this work, 222Rn activity, major dissolved ions, and microbial community in ground- and surface waters were investigated to characterize groundwater inflow to the stream located in an urban area, Daejeon, Korea. The measured 222Rn activities in groundwater and stream water ranged from 136 to 231 Bq L-1 and 0.3 to 48.8 Bq L-1, respectively. The spatial distributions of 222Rn activity in the stream strongly suggested groundwater inflow to the stream. The change of geochemical composition of the stream water indicated the effect of groundwater discharge became more pronounced as the stream flows downstream. Furthermore, microbial community composition of the stream water had good similarity to that of groundwater, which is another evidence of groundwater discharge. Although groundwater inflow could not be estimated quantitatively in this study, the results can provide useful information to understand interactions between groundwater and surface water, and determine hydrological processes governing groundwater recharge and hydrogeological cycles of dissolved substances such as nutrients and trace metals.

Estimation of groundwater inflow into an underground oil storage facility in granite

  • Wang, Zhechao;Kwon, Sangki;Qiao, Liping;Bi, Liping;Yu, Liyuan
    • Geomechanics and Engineering
    • /
    • 제12권6호
    • /
    • pp.1003-1020
    • /
    • 2017
  • Estimation of groundwater inflow into underground opening is of critical importance for the design and construction of underground structures. Groundwater inflow into a pilot underground storage facility in China was estimated using analytical equations, numerical modeling and field measurement. The applicability of analytical and numerical methods was examined by comparing the estimated and measured results. Field geological investigation indicated that in local scale the high groundwater inflows are associated with the appearance of open joints, fractured zone or dykes induced by shear and/or tensile tectonic stresses. It was found that 8 groundwater inflow spots with high inflow rates account for about 82% of the total rate for the 9 caverns. On the prediction of the magnitude of groundwater inflow rate, it was found that could both (Finite Element Method) FEM and (Discrete Element Method) DEM perform better than analytical equations, due to the fact that in analytical equations simplified assumptions were adopted. However, on the prediction of the spatial distribution estimation of groundwater inflow, both analytical and numerical methods failed to predict at the present state. Nevertheless, numerical simulations would prevail over analytical methods to predict the distribution if more details in the simulations were taken into consideration.

터널굴착 중 지하수위 강하 및 깊이별 투수계수 변화를 적용한 지하수 유입량 변화 분석 (Assessment of groundwater inflow rate into a tunnel considering groundwater level drawdown and permeability reduction with depth)

  • 문준식;쩡안치;장서용
    • 한국터널지하공간학회 논문집
    • /
    • 제19권2호
    • /
    • pp.109-120
    • /
    • 2017
  • 터널 내 지하수 침투는 터널붕괴와 그에 따른 지반침하의 주요 원인 중 하나이다. 따라서 터널굴착 중 시간에 따른 지하수 침투량과 간극수압 변화를 적절히 예측하는 것이 중요하다. 실무에서는 균질한 지반조건으로 가정하는 Goodman의 산정법을 사용하여 지하수 침투량을 계산하지만, 터널굴착 중 지하수위 강하와 깊이에 따른 투수계수 변화를 고려하지 않아 설계단계에서 지하수 유입량을 과다하게 산정할 우려가 있다. 따라서 본 연구에서는 지하수위 강하 및 깊이별 투수계수의 감소를 적용한 매개변수분석을 통해 지하수 유입량 변화를 분석 비교하였으며, 시간에 따른 지하수 침투량 변화와 지하수위 및 간극수압 분포 변화를 분석하기 위해 비정상류 해석을 수행하였다.

제주도 관정 공벽 내 오염물질 유입 구간 탐지 및 차단 사례 (Case for Detection and Prevention of Inflow Section for Contaminant through Annular Space in Borehole, Jeju Island)

  • 송성호;황보동준;김진성;양원석
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제27권3호
    • /
    • pp.1-10
    • /
    • 2022
  • Most wells developed in Jeju island before the enactment of the Groundwater Management Ordinance in 2002 are vulnerable to aquifer contamination due to inflow of upper groundwater having the high concentration of nitrate nitrogen, likely due to incomplete grouting in upper section of the wells. Although these wells require entire reinstallation, it is often necessary to rehabilitate the existing wells due to various constraints. Therefore, to identified the inflow section of contaminants, the thermal level sensor (TLS) technique was firstly applied for three wells, which enables to monitor temperature variations in every 50 cm depth. Then, the grouting material was injected to the upper section to prevent the inflow of upper contaminated groundwater into the entire aquifer. By applying TLS technique, it was found that the temperature deviations in the upper groundwater inflow section decreased sharply. Moreover, both the change in the concentration of nitrate nitrogen in the rainy/dry seasons and the average concentrations were found to decrease rapidly after grouting material injection. Consequently, the application of TLS proposed in the study turned out to be appropriate to prevent aquifer contamination.

청송군 현서면 일대 도수로터널내 지하수 유입량과 수리지질 특성의 관련성 (Relation between Groundwater Inflow into the Waterway Tunnel and Hydrogeological Characteristics in Hyeonseo-myeon, Cheongsong-gun, Korea)

  • 박재현;함세영;성익환;이병대;정재열
    • 지질공학
    • /
    • 제11권2호
    • /
    • pp.141-152
    • /
    • 2001
  • 영천댐 도수로 터널 중 청송군 현서면 지역의 터널 구간(연장 1,484m)에 대한 터널내 유입량과 수리지질학적 특성간의 관계를 연구하였다. 본 연구에서는 터널내로 유입되는 초기 유입량(라이닝 및 그라우팅 이전의 유입량)과 터널지역의 사암층, 절리빈도, 절리간극 및 간격, 단층, 수리전도도간의 관계를 분석하였다. 그리고 절리빈도와 수리전도도의 관계도 고찰하였다. 본 연구지역에서는 단층폭과 터널내 지하수 유입량의 관련성이 가장 크며, 사암의 두께, 수리전도도, 절리빈도순으로 관련성이 낮아지는 것으로 판단된다.

  • PDF

CONSTRUCTION MANAGEMENT OF TUNNELLING IN SEVERE GROUNDWATER CONDITION

  • Young Nam Lee;Dae Young Kim
    • 국제학술발표논문집
    • /
    • The 1th International Conference on Construction Engineering and Project Management
    • /
    • pp.655-661
    • /
    • 2005
  • For a hydro power plant project, the headrace tunnel having a finished diameter of 3.3m was constructed in volcanic rocks with well-developed vertical joint and high groundwater table. The intake facility was located 20.3 km upstream of the powerhouse and headrace tunnel of 20 km in length and penstock of 440 m in height connected the intake and the powerhouse. The typical caldera lake, Lake Toba set the geology at the site; the caving of the ground caused tension cracks in the vertical direction to be developed and initial stresses at the ground to be released. High groundwater table(the maximum head of 20 bar) in the area of well-connected vertical joints delayed the progress of tunnel excavation severely due to the excessive inflow of groundwater. The excavation of tunnel was made using open-shield type TBM and mucking cars on the rail. High volume of water inflow raised the water level inside tunnel to 70 cm, 17% of tunnel diameter (3.9 m) and hindered the mucking of spoil under water. To improve the productivity, several adjustments such as modification of TBM and mucking cars and increase in the number of submersible pumps were made for the excavation of severe water inflow zone. Since the ground condition encountered during excavation turned out to be much worse, it was decided to adopt PC segment lining instead of RC lining. Besides, depending on the conditions of the water inflow, rock mass condition and internal water pressure, one of the invert PC segment lining with in-situ RC lining, RC lining and steel lining was applied to meet the site specific condition. With the adoption of PC segment lining, modification of TBM and other improvement, the excavation of the tunnel under severe groundwater condition was successfully completed.

  • PDF