• 제목/요약/키워드: Inflow condition

검색결과 344건 처리시간 0.028초

균일 및 난류 입구조건이 램프 후류 형상 및 성장에 미치는 영향 (Effects of Uniform and Turbulent Inflow Conditions on Wake Topology and Vortex Growth Behind a Ramp)

  • 구티 로키시 카리안;요시프 무스타파;임희창
    • 한국가시화정보학회지
    • /
    • 제21권2호
    • /
    • pp.24-33
    • /
    • 2023
  • This work is to observe the wake flow generated behind a ramp. We have conducted a large eddy simulation with two ramp models having different heights with two different inflow conditions. Reynolds number based on the height of the large ramp (LR) and small ramp (SR) are Reh = 2.8×104 and 1.4×104 respectively. The wake flow visualization shows the formation of streamwise counter-rotating vortices pairs at the downstream of the obstacle. These primary vortices are stretched and lifted up when moving downstream. In order to observe the effect of the inflow condition on the wake transition, two different inlet flow conditions are given on the inlet section as an inlet boundary condition. Induced counter-rotating vortices pairs due to sharp-edged triangular ramp obstacles are developed and propagated downstream. In the result, the large ramp shows a more complicated wake structure of the boundary layer than the small ramp.

산성 및 유기성 가스의 동시제거를 위한 준건식 세정시스템의 적정 운전 조건 (Optimal Operation Condition of Spray Drying Sorber for Simultaneous Removal of Acidic and Organic Gaseous Pollutants)

  • 백경렬;구자공
    • 한국환경과학회지
    • /
    • 제10권1호
    • /
    • pp.59-64
    • /
    • 2001
  • The effect of major operating parameters in spray drying sorber(=SDS) for automatic control for the simultaneous removal of acidic and organic gaseous pollutants from solid waste incinerator was performed. The field experiment was carried out in pilot scale test for the quantification of major operating parameters of hydrophilic and the hydrophobic pollutants. The removal efficiencies of $SO_2$and HCI in the 5wt% slurry condition were being increased with the increase of the stoichiometric ration which is the molecular ratio of lime to the pollutant concentration, and with the decrease of inflow flue gas temperature in the pilot SDS reactor. The removal efficiency along the height of spray drying sorber was closely related to the temperature profile, and more than 90% of total removal efficiency was achieved in an absorption region. For the removal of acidic gas the optimum operating condition considering the economics and a stable operation is the 5wt% of slurry concentration, 1.2 of stoichiometric ratio and 25$0^{\circ}C$ of inflow flue gas temperature. For the organic gases of benzene and toluene the removal efficiencies were 20-60% which is much lower than that of acidic gas. The best removal efficiency was obtained at 1.5 of stoichiometric ratio and 25$0^{\circ}C$ of inflow flue gas temperature. The organic\`s removal efficiency along the height of spray drying sorber was quite different from that of acidic gas, that is, more than 60% of the total removal efficiency for benzene and 90% of the total removal for toluene were achieved in the dried adsorption region, which was formed at the lower or exit part of the reactor.

  • PDF

관개저수지의 홍수유입량 예측 (Forecasting the Flood Inflow into Irrigation Reservoir)

  • 문종필;엄민용;박철동;김태얼
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 1999년도 Proceedings of the 1999 Annual Conference The Korean Society of Agricutural Engineers
    • /
    • pp.512-518
    • /
    • 1999
  • Recently rainfall and water evel are monitored via on -line system in real-time bases. We applied the on-line system to get the rainfall and waterlevel data for the development of the real-time flood forecasting model based on SCS method in hourly bases. Main parameters for the model calibration are concentration time of flood and soil moisture condition in the watershed. Other parameters of the model are based on SCS TR-%% and DAWAST model. Simplex method is used for promoting the accuracy of parameter estimation. The basic concept of the model is minimizing the error range between forcasted flood inflow and actual flood inflow, and accurately forecasting the flood discharge some hours in advance depending on the concentration time. The flood forecasting model developed was applied to the Yedang and Topjung reservoir.

  • PDF

주기적 불안정성을 가지는 충격파 유도 연소의 무차원 해석 (Nondimensional Analysis of Periodically Unstable Shock-Induced Combustion)

  • 최정열;정인석;윤영빈
    • 한국연소학회지
    • /
    • 제1권2호
    • /
    • pp.41-49
    • /
    • 1996
  • A numerical study is conducted to investigate the periodically unstable shock induced combustion around blunt bodies in stoichiometric hydrogen-air mixtures. Euler equations are spatially discretized by upwind-biased third order scheme and temporally integrated by Runge-Kutta method. Chemistry model used in this study involves 8 elementary kinetics steps and 7 species. At a constant Mach number, the effects of projectile size, inflow pressure and inflow temperature are examined with Lehr#s experimental condition as a reference. In addition to oscillation frequency, characteristic distances and time averaged values are found from the result to find an relation with dimensionless parameters. As a result, it is found that the effects of inflow pressure and body size are very similar and $Damk{\ddot{o}}hler$ number plays an important role in determining the instability characteristics.

  • PDF

수계별 소수력자원의 수문학적 성능특성 (Hydrologic Performance Characteristics of Small Hydro Power Resources for River Systems)

  • 박완순;이철형
    • 한국태양에너지학회 논문집
    • /
    • 제30권2호
    • /
    • pp.65-71
    • /
    • 2010
  • The hydrologic performance characteristics of small hydro power(SHP) sites located in four major river systems have been studied. The model, which can predict flow duration characteristic of stream, was developed to analyze the variation of inflow caused from rainfall condition. And another model to predict hydrologic performance for SHP plants is established. Monthly inflow data measured at Andong dam for 32 years were analyzed. The predicted results from the developed models in this study showed that the data were in good agreement with measured results of long term inflow at Andong dam. The results from hydrologic performance analysis for SHP sites located on five major river systems based on the models developed in this study show that the specific design flowrate and specific output of SHP site have large difference between the river systems.

RMR 및 Q 분류시 지하수 조건 평가방법에 관한 사례 연구 (A Case Study for Evaluating Groundwater Condition in RMR and Q Rock Mass Classification on Bard Rock Tunnel)

  • 이대혁;이철욱;김호영
    • 터널과지하공간
    • /
    • 제13권5호
    • /
    • pp.353-361
    • /
    • 2003
  • 터널 조사계획 혹은 공사중, RMR 및 Q분류법에 따라 암반분류를 수행하는데 있어 지하수조건에 대한 평가는 가능한 조건들의 제약 때문에 경험적 방법에 의존하고 있다. 절리 수압 및 지하수 유입량 측정, 수리전도도 모델 산정, 3차원 수치해석 및 해석해 방법을 사용한 대전 LNG Pilot Cavern의 결과를 바탕으로, 지하수 조건 평가에 관한 합리적인 접근 방법을 비교 검토하였다. 그 결과, Raymer(2001) 이론해 방법이 예비 조사단계에서 유용한 도구로 활용될 수 있음을 검증하였다.

뇌의 기능영상에 있어서 자화율효과와 혈류효과 연구 (Susceptibility Effects v.s Flow Effects in Functional MRI)

  • 박종배;정순철;박세혁;노용만;조장희
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1993년도 추계학술대회
    • /
    • pp.23-26
    • /
    • 1993
  • In MR functional imaging, it is shown that the signal change during photic activation is composed of two terms, i.e. the inflow effect and the susceptibility effect. Relatively the inflow effect affects the data obtained by CGE on the condition of short $T_E$(15ms) and large $\alpha$(90degree). The susceptibility effect, however, mainly contributes to the data on the condition of large $T_E$(35ms) and small $\alpha$(30degree). In this apper, we will discriminate the susceptibility effect for the intermingled data affected both flow effect and susceptibility effect. Finally susceptibility only functional imaging is proposed by using TRFGE.

  • PDF

터널굴착 중 지하수위 강하 및 깊이별 투수계수 변화를 적용한 지하수 유입량 변화 분석 (Assessment of groundwater inflow rate into a tunnel considering groundwater level drawdown and permeability reduction with depth)

  • 문준식;쩡안치;장서용
    • 한국터널지하공간학회 논문집
    • /
    • 제19권2호
    • /
    • pp.109-120
    • /
    • 2017
  • 터널 내 지하수 침투는 터널붕괴와 그에 따른 지반침하의 주요 원인 중 하나이다. 따라서 터널굴착 중 시간에 따른 지하수 침투량과 간극수압 변화를 적절히 예측하는 것이 중요하다. 실무에서는 균질한 지반조건으로 가정하는 Goodman의 산정법을 사용하여 지하수 침투량을 계산하지만, 터널굴착 중 지하수위 강하와 깊이에 따른 투수계수 변화를 고려하지 않아 설계단계에서 지하수 유입량을 과다하게 산정할 우려가 있다. 따라서 본 연구에서는 지하수위 강하 및 깊이별 투수계수의 감소를 적용한 매개변수분석을 통해 지하수 유입량 변화를 분석 비교하였으며, 시간에 따른 지하수 침투량 변화와 지하수위 및 간극수압 분포 변화를 분석하기 위해 비정상류 해석을 수행하였다.

도심지 강우 특성을 고려한 투수성 보도블록의 배수 특성 (Characteristics of Drainage Pervious Block Considering Urban Rainfall)

  • 서다와;윤태섭;염광수;정상섬;문성호
    • 한국지반공학회논문집
    • /
    • 제31권1호
    • /
    • pp.53-64
    • /
    • 2015
  • 본 연구는 도심지 내 집중 강우 특성을 고려한 투수성 보도블록의 배수 특성을 알아보기 위하여 2 가지 골재크기에 대하여 강도, 투수성, 증발 및 배수실험을 실시하였다. 강도의 경우 골재크기와 무관하게 한국산업표준(KS) 규격을 만족시킨 반면, 작은 골재로 구성된 투수성 보도블록의 경우 단위시간당 유량이 작은 경우에도 표면유출이 발생하였다. 큰 골재는 초기 우수조건에서의 배수는 원활한 반면 일정시간이 지난 후 동일한 유량의 배수실험에서 표면유출이 관찰되었다. 이는 간극 내부의 물이 투수성을 저감시키는 역할로 작용한 것으로, 투수성 보도블록의 투수성과 배수 성능은 간극비나 간극연결도 만으로 결정되는 것이 아니고 시간에 따른 증발, 선행우수조건에 의해 좌우됨을 나타낸다. 또한 초기 포화도보다는 이중선형 형태의 시간당 증발 양상과 유입량과 증발로 인한 내부 포화도 변화가 표면유출에 미치는 영향이 큰 것으로 나타났다.

Dilemma of a small dam with large basin area under climate change condition

  • Jeong-Hyeok Ma;Chulsang Yoo;Tae-Sup Yun;Dongwhi Jung
    • Computers and Concrete
    • /
    • 제33권5호
    • /
    • pp.559-572
    • /
    • 2024
  • Problems of under-sized dams (small dams with large basin area) could get worse under the global warming condition. This study evaluates the possible change of these problems with the Namgang Dam, an under-sized dam in Korea. For this purpose, first, this study simulates the dam inflow data using a rainfall-runoff model, which are then used as input for the reservoir operation. As a result, daily dam storage, dam release, and dam water supply are derived and compared for both past observed period (1973~2022) and future simulated period (2006~2099) based on the global warming scenarios. Summarizing the results are as follows. First, the inflow rate in the future is expected to be increased significantly. The maximum inflow could be twice of that observed in the past. As a result, it is also expected that the frequency of the water level reaching the high level is increasing. Also, the amount and frequency of dam release are to be increased in the future period. More seriously, this increase is expected to be concentrated on rather extreme cases with large dam release volume. Simply, the condition for flood protection in the downstream of the Namgang Dam is becoming worse and worse. Ironically, the severity of water shortage problem is also expected to become much worse. As the most extreme case, the frequency of no water supply was zero in the observed period, but in the future period, it becomes once every five years. Both the maximum consecutive shortage days and the total shortage volume are expected to become more than twice in the future period. To prevent or mitigate this coming problem of an under-sized dam, the only countermeasure at this moment seems to be its redevelopment. Simply a bigger dam with larger dam reservoir can handle this adverse effect more easily.