• 제목/요약/키워드: Infiltration Ratio

검색결과 228건 처리시간 0.027초

Early Detection of Intravenous Infiltration Using Multi-frequency Bioelectrical Impedance Measurement System: Pilot Study

  • Kim, Jaehyung;Shin, Beumjoo;Jeon, Gyerok
    • Journal of information and communication convergence engineering
    • /
    • 제15권2호
    • /
    • pp.123-130
    • /
    • 2017
  • The early detection of intravenous (IV) infiltration is necessary to minimize the injury caused by the infiltration, which is one of the most important tasks for nurses. For detecting early infiltration in patients receiving invasive vein treatment, bioelectrical impedance was measured using multi-frequency bioelectrical impedance. The impedance decreased significantly at infiltration, and then decreased gradually over time after infiltration. The relative impedance at 20 kHz decreased remarkably at infiltration, and then gradually decreased thereafter. In addition, the impedance ratio increased temporarily at infiltration and then gradually decreased over time. Furthermore, the impedance at each frequency decreased quantitatively over time. This indicates that IV solution leaking from the vein due to infiltration accumulates in the subcutaneous tissues. Moreover, slopes of log Z vs. log f differently decreased with increasing log f, indicating that the impedance exhibits different responses depending on the frequency.

무가압침투법에 의한 $Al_2O_3/Al$ 복합재료의 제조특성 (Fabrication of $Al_2O_3/Al$ Composites by Pressureless Infiltration Technique)

  • 김재동;김형진;고성위
    • 동력기계공학회지
    • /
    • 제3권2호
    • /
    • pp.57-63
    • /
    • 1999
  • The fabrication of $Al_2O_3/Al$ composites by pressureless infiltration technique was made to investigate the effects of processing variables such as content of Mg, processing temperature and time on the infiltration behavior of molten Al and microstructure. When the pure Al was infiltrated into mixtures of Mg and $Al_2O_3$ powder, processing temperature required to spontaneous infiltration was decreased and critical processing temperature and Mg content were $700^{\circ}C$ and 3wt% respectively. The content of Mg was found the most powerful variable for infiltration of molten Al. The infiltration ratio increased with Mg content and processing temperature, however the $Al_2O_3/Al$ composites which were fabricated by high Mg content and processing temperature resulted in non uniform dispersion of $Al_2O_3$ particles by excessive interfacial reaction. XRD pattern indicated that $MgAl_2O_4$ and AIN was observed at the interface of $Al_2O_3$ particles and in the Al matrix as reaction products.

  • PDF

불포화투수계수를 이용한 지반의 연속 침투능 산정 (Estimation of Continuous Infiltration Process by Unsaturated Permeability)

  • 한희수;이정식;장진욱;양남용
    • 지질공학
    • /
    • 제20권2호
    • /
    • pp.137-146
    • /
    • 2010
  • 강우시 침투량 산정을 위하여 일반적으로 기존의 침투능 산정식인 Horton 공식 및 Green-Ampt 공식으로 지반 내 침투능을 산정해 왔다. 하지만, 실제 강우로 인한 지반 침투는 연속적으로 침투가 이루어지므로, 이와 같은 불연속적인 침투량 산정공식의 단점을 보완하고자 연속적인 침투능 산정공식을 새로이 유도하여, 침투능 및 침투량을 비교 분석하고자 하였다. 유도된 식 및 기존의 침투공식을 검증하기 위한 침투실험을 행하여 각 식의 결과들을 비교 분석하였다. 함수비 혹은 포화도의 함수인 불포화투수계수는 직접적으로 침투능 및 침투량에 영향을 끼치므로, 새로이 유도된 식은 침투과정에 따른 불포화투수계수의 변화를 이용하여 보다 정확한 침투능 및 침투량을 산정하고자 하였으며, 침투로 인한 구조물의 안정 및 지하수 거동을 보다 정확히 해석하기 위한 것이다.

석회석 미분말 혼합 콘크리트의 염소이온 침투 저항 특성 (Characteristic on the Resistance of Chloride Infiltration in Concrete Containing Limestone Powder)

  • 구봉근;라재웅;류택은;이재범;이현석;이기호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.75-80
    • /
    • 2002
  • This study is to investigate the characteristic on the resistance of chloride infiltration concrete containing limestone powder The variables are the substitution ratio of slag powder and limestone powder. In order to study the effect slag powder and limestone powder, all mixtures were prepared at a fixed water/cement ratio, slump, and entrained air quantity. As results show that the strength and the resistance of chloride infiltration in concrete substitution 10%, 20% limestone powder, and 30%, 40% slag powder are positive.

  • PDF

장기 모니터링 자료를 활용한 침입수 산정 방법론별 특성 분석 (Characterization of Infiltration Analyses Using Long-Term Monitoring Flow Data)

  • 이재현;김인섭;오재일;박철휘
    • 한국물환경학회지
    • /
    • 제25권3호
    • /
    • pp.411-418
    • /
    • 2009
  • The analysis of characteristics of water use evaluation and nighttime domestic flow evaluation was performed by using result from flow monitoring and surveying water supply records and nighttime domestic flow for a year. The analysis of correlations showed that, for both sites, the infiltration ratio and wastewater flow have shown a good relationship with high correlation factor and that the calculation of wastewater flow was highly affected by monthly rainfall depth as well as number of rain days. From this result, it was concluded that the measurement of infiltration should be performed when the rainfall does not significantly affect the sewer flow. Also, it is notable that each value of calculated using method for infiltration evaluation are not comparable to each other, but independent methods. In selecting of evaluation method for infiltration, therefore, a great emphasis should be imposed to the character of area and the seasonal factor in order to select optimal one. It is desirable way for evaluating infiltration and reduction ratio using result from an optimal method.

반응결합 소결에 의한 TiC-Co/Al 복합체의 미세구조 및 기계적 특성 (Microstructure and Mechanical Properties of TiC-Co/Al Composites Prepared by Reaction-Bonded Sintering)

  • 한인섭;남기웅;정윤중
    • 한국세라믹학회지
    • /
    • 제32권2호
    • /
    • pp.257-269
    • /
    • 1995
  • The TiC-Co/Al reaction-sintered products were prepared by the infiltration of various Co/Al metal mixture into the preform, and their microstructure, phases, and mechanical properties were investigated. With increasing the atomic ratio of Co/Al, tiC grain shape was changed from spherical to platelet particles, and the grain size increased. The crystalline phases found in the liquid matrix formed by the infiltration of Co/Al metal mixture were determined to be Al5Co2 and AlCo by EDS and XRD, and the two crystalline phases were located dominantly between TiC grains, when the Co/Al atomic ratio was lower than an unity. There was a tendency that the density, bending strength and fracture toughness increase with Co/Al atomic ratio until the infiltrated metal was 100% Co. The maximum value was achieved by the composition containing 100% Co infiltrated metal. The Vickers hardness decreased as Co/Al atomic ratio increased.

  • PDF

유출저감을 위한 유역내 침투시설의 적용 (An Application of Infiltration Facilities for Reducing the Runoff in the Basin)

  • 이재준;설지수
    • 한국방재학회 논문집
    • /
    • 제11권3호
    • /
    • pp.133-141
    • /
    • 2011
  • 유역의 도시화는 유출총량과 첨두유량의 증가와 도달시간이 감소시키며, 홍수피해의 위험성을 더욱 크게 만든다. 침투시설은 도시유역의 유출총량과 첨두유량을 감소시킬 수 있고, 그 종류에는 침투트렌치와 투수성 포장재 등이 있다. 본 연구에서는 침투시설 설치에 따른 우수유출저감효과를 알아보기 위하여 경북 구미시 옥계동의 $0.18km^2$와 공단동의 $0.67km^2$의 면적을 가진 도시유역을 대상으로 하여 각각의 유역특성을 분석하고, 유출총량 및 첨두유량의 저감량을 WinSLAMM 모형을 이용하여 분석하였다. 또한, 침투시설 설치에 따른 첨두유량저감효과를 분석하였고, 침투시설 면적비와 유출저감률과의 관계식을 도출하였다.

광센서 기반 휴대형 침윤 조기 감지기 개발 (A Development of Portable Early Detector of Intravenous Infiltration based on Optical Sensor)

  • 이성진;신범주;정인숙
    • 한국멀티미디어학회논문지
    • /
    • 제21권6호
    • /
    • pp.705-711
    • /
    • 2018
  • Intravenous(IV) therapy being in use for many patients may cause serious side effects such as infiltration, extravasation. To minimize such side effects, it is important to detect symptoms appearing when fluid escapes from blood vessel to tissue as soon as possible. This paper describes a device which has been developed to detect IV infiltration early using optical sensor. The device detects IV infiltration as measuring intensity of lights reflected from that lights after emitting lights in IV therapy site. The lights are consisted of 4 different waves which provide different reflection ratio depending the fluid used in IV therapy. The experimental results show that the device can be used to detect IV infiltration early.

W-Cu 계에서 W 분말골격의 in-situ 구조 변화와 Cu의 용침 kinetics (In-situ Structure Modification of W powder Skeleton and related Cu Infiltration Kinetics in W-Cu)

  • 이재성
    • 한국분말재료학회지
    • /
    • 제6권1호
    • /
    • pp.36-41
    • /
    • 1999
  • The present work has attempted to investigate the dependence of Cu infiltration kinetics on in-situ structure modification of W powder skeleton in W-Cu system. In-situ structure modification of W skeleton by addition of 0.3wt%Ni-P eutectic alloy was designed to proceed during heat-up of the W compact for Cu infiltration process. It was found that the Ni-P added W skeleton underwent remarkable stucture change only during heating-up. its structure was composed of large necks of W particles above 0.5 in the ratio of neck to particle size and smooth pore channels. The infiltration experiment showed that the infiltration kinetics for the W-Ni-P followed well the linear relationship of h vs. $t^{1/2}$ the rate constant K of which was in good agreement with the theoretical value. On the other hand, in case of the pure W skeleton a lower K value by 20% than the theoretical one was obatined. Such discrepancy is discussed in terms of skeleton structure induced infiltration mechanics.

  • PDF