• Title/Summary/Keyword: Inertial measurement unit(IMU)

Search Result 220, Processing Time 0.024 seconds

A Strap-Down Inertial Measuring Unit for Motion Measurement of an AUV (AUV의 운동계측을 위한 스트랩-다운형 관성계측장치(IMU)의 개발)

  • 이판묵;전봉환;이종식;오준호;김도현
    • Journal of Ocean Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.95-105
    • /
    • 1997
  • This paper presents a Inertial Measuring Unit(IMU) for motion measurement of an AUV. The IMU is composed of three parts: inertial sensors with three servo accelerometers and three rate gyros, an analog/digital interface board, and a signal processing board with TMS320C31 DSP processor. The IMU is a class of strap-down inwetial navigation system does not applicable directly to the navigation system in consequence of the AUV and integrated sensors for an integrated navigation system of the AUV. Fast calculstion of direction cosine matrix for the coordinate transformation body to reference is obtained through the DSP processor. A switching algotrithm is used to lessen the low frequency drift effect of the gyros in the vertical plane with use of low pass filtering of the signal of the accelerometers.

  • PDF

Evaluation and Selection of MEMS-Based Inertial Sensor to Implement Inertial Measurement Unit for a Small-Sized Vessel (소형 선박용 관성측정장치 개발을 위한 MEMS 기반 관성 센서의 평가와 선정)

  • Yim, Jeong-Bin
    • Journal of Navigation and Port Research
    • /
    • v.35 no.10
    • /
    • pp.785-791
    • /
    • 2011
  • This paper describes the evaluation and selection of MEMS(Micro-Elect Mechanical System) based inertial sensor to fit to implement the Inertial Measurement Unit(IMU) for a small-sized vessel at sea. At first, the error model and the noise model of the inertial sensors are defined with Euler's equations and then, the inertial sensor evaluation is carried out with Allan Variance techniques and Monte Carlo simulation. As evaluation results for the five sensors, ADIS16405, SAR10Z, SAR100Grade100, LIS344ALH and ADXL103, the combination of gyroscope and accelerometer of ADIS16405 is shown minimum error having around 160 m/s standard deviation of velocity error and around 35 km standard deviation of position error after 600 seconds. Thus, we select the ADIS16405 inertial sensor as a MEMS-based inertial sensor to implement IMU and, the error reducing method is also considered with the search for reference papers.

Education Equipment and Its Application for Indoor Position Recognition Using Inertial Measurement Unit Sensor (IMU센서를 이용한 실내 위치 인식 교육용 장비 및 응용)

  • Seo, Bo-In;Yu, YunSeop
    • Journal of Practical Engineering Education
    • /
    • v.10 no.2
    • /
    • pp.119-124
    • /
    • 2018
  • Educational equipment that enables the user or device to recognize the indoor position by using the acceleration and angular velocity of the IMU (Inertial Measurement Unit) sensor is introduced. With this educational equipment, various position recognition and tracking algorithms can be learned and creative engineering design works can be realized. The data value of the IMU sensor is transmitted to the MCU (microcontroller unit) through $I^2C$ (Inter-Integrated Circuit), and the indoor position recognition algorithm is applied by processing the data value through the filter and numerical method. It is then designed to use wireless communication to send and receive processed values and to be recognized by the user. As an example using this equipament, the case of "Implementation and recognition of virtual position using computation of moving direction and distance using IMU sensor" is introduced, and various creative engineering design application is discussed.

A review on measuring cervical range of motion using an inertial measurement unit (관성측정장치를 이용한 경추 가동범위 측정에 대한 고찰)

  • Yim, Juhyuk;Kim, Hyunho;Park, Young-Jae;Park, Young-Bae
    • The Journal of Korean Medicine
    • /
    • v.38 no.1
    • /
    • pp.56-71
    • /
    • 2017
  • Objectives: The purpose of this study was to review the article using an IMU(Inertial Measurement Unit) for measuring the cervical range of motion and to evaluate the feasibility of using an IMU for measuring the cervical range of motion. Method: Scopus was used to search for the articles relating to the inclusion criteria. Which is measuring the cervical range of motion using an IMU. A total of 15 articles were selected through discussion. Degree and the reliability of the cervical range of motion and the validity of the data within the articles were extracted. Results: The measurement of the cervical range of motion using an IMU were $92.25^{\circ}$ to $138.2^{\circ}$, $122.4^{\circ}$ to $154.9^{\circ}$, $73.75^{\circ}$ to $93.1^{\circ}$ on the sagittal plane, transverse plane, and coronal plane respectively. 38 of the 43 values showed good reliability. They were larger than 0.75. 5 of the 43 values showed reliability less than 0.75. They were measured by smart phone. 16 of the 21 values showed good validity. The remaining 5 were measured by smart phone. The lower reliability and validity of smart phone were related to the protocol. The IMU can measure the coupling motion and may be used in various situations. Conclusion: The IMU may become a gold standard for measuring the cervical range of motion. The IMU measured not only the cervical range of motion but also the coupling motion. Furthermore, IMU may be used in various situations. Therefore, IMU must be considered a valuable measurement device.

Systematic Review on the Type and Method of Convergence Study of Inertial Measurement Unit (관성 측정 장치의 융합연구 형태와 방법에 관한 체계적 고찰)

  • Lee, Hey-Sig;Park, Hae-Yean
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.3
    • /
    • pp.119-126
    • /
    • 2020
  • The purpose of this study is to identify trends in the type and method of Inertial Measurement Unit (IMU) by investigating studies on the type and method of convergence study of the IMU by systematic review. The study was conducted using PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. 23 studies that meet the selection criteria were selected from 630 studies identified by three databases. As a result of this study, showed that various research using IMU was being conducted around the world, and the type of IMU was strap, full body suit, belt, wrist watch, shoes and glove. Among them, the number of strap-type IMUs was the largest at 11. The IMU's strengths were simplicity, real-time data collection and ease of application, which were used as measurement methods such as task, walking, and range of joint. The result of this study is expected to be used as basic data for experts in the medical and rehabilitation fields that conduct IMU research.

A Strap-Down Inertial Measuring Unit for Motion Measurement of an AUV (AUV의 운동계측을 위한 스트랩-다운형 관성계측장치(IMU)의 개발)

  • Lee, Pan-Muk;Jeon, Bong-Hwan;Lee, Jong-Sik;Oh, Jun-Ho;Kim, Do-Hyeon
    • Journal of Ocean Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.96-96
    • /
    • 1997
  • This paper presents a Inertial Measuring Unit(IMU) for motion measurement of an AUV. The IMU is composed of three parts: inertial sensors with three servo accelerometers and three rate gyros, an analog/digital interface board, and a signal processing board with TMS320C31 DSP processor. The IMU is a class of strap-down inwetial navigation system does not applicable directly to the navigation system in consequence of the AUV and integrated sensors for an integrated navigation system of the AUV. Fast calculstion of direction cosine matrix for the coordinate transformation body to reference is obtained through the DSP processor. A switching algotrithm is used to lessen the low frequency drift effect of the gyros in the vertical plane with use of low pass filtering of the signal of the accelerometers.

Feasibility on Evaluation of Movement System Impairment Syndromes by MEMS-IMU (관성측정장치를 이용한 동태손상증후군의 평가 가능성에 관한 고찰)

  • Kim, Hyun-Ho;Kim, Jeong-Kyun;Seo, Jae-Ho;Park, Young-Jae;Park, Young-Bae
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.15 no.3
    • /
    • pp.223-234
    • /
    • 2011
  • Objectives: This study shows feasibility and suitability of a microelectromechanical system inertial measurement unit(MEMS-IMU) as a helpful measurement device for evaluating movement system impairment syndrome. Methods: We reviewed articles of two fields in this study. First, we reviewed articles about movement system impairment syndrome(MSIS) as a brand new viewpoint of diagnosing and treating musculoskeletal pain. Second, we reviewed articles about conventional motion analysis system and inertial measurement unit(IMU) to show the superiority of IMU in analyzing the human movement. All papers were searched by SciVerse, world largest search engine and database about many academic fields including engineering and medicine. Results: Some physical quantities of human motions can be useful to the diagnosis of MSIS, and those data can be obtained by the MEMS-IMU without the weak points of the conventional motion analysis systems. Conclusions: Using MEMS-IMU as a measurement unit for diagnosing and evaluating MSIS is feasible and can be extended to many further studies.

Ackermann Geometry-based Analysis of NHC Satisfaction of INS for Vehicular Navigation according to IMU Location

  • Cho, Seong Yun;Chae, Myeong Seok
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.11 no.1
    • /
    • pp.29-34
    • /
    • 2022
  • In this paper, we analyze the Non-Holonomic Constraint (NHC) satisfaction of Inertial Navigation System (INS) for vehicular navigation according to Inertial Measurement Unit (IMU) location. In INS-based vehicle navigation, NHC information is widely used to improve INS performance. That is, the error of the INS can be compensated under the condition that the velocity in the body coordinate system of the vehicle occurs only in the forward direction. In this case, the condition that the vehicle's wheels do not slip and the vehicle rotates with the center of the IMU must be satisfied. However, the rotation of the vehicle is rotated by the steering wheel which is controlled based on the Ackermann geometry, where the center of rotation of the vehicle exists outside the vehicle. Due to this, a phenomenon occurs that the NHC is not satisfied depending on the mounting position of the IMU. In this paper, we analyze this problem based on Ackermann geometry and prove the analysis result based on simulation.

IMU-Barometric Sensor-based Vertical Velocity Estimation Algorithm for Drift-Error Minimization (드리프트 오차 최소화를 위한 관성-기압센서 기반의 수직속도 추정 알고리즘)

  • Ji, Sung-In;Lee, Jung Keun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.11
    • /
    • pp.937-943
    • /
    • 2016
  • Vertical velocity is critical in many areas, such as the control of unmanned aerial vehicles, fall detection, and virtual reality. Conventionally, the integration of GPS (Global Positioning System) with an IMU (Inertial Measurement Unit) was popular for the estimation of vertical components. However, GPS cannot work well indoors and, more importantly, has low accuracy in the vertical direction. In order to overcome these issues, IMU-barometer integration has been suggested instead of IMU-GPS integration. This paper proposes a new complementary filter for the estimation of vertical velocity based on IMU-barometer integration. The proposed complementary filter is designed to minimize drift error in the estimated velocity by adding PID control in addition to a zero velocity update technique.

A Calibration Technique for a Redundant IMU Containing Low-Grade Inertial Sensors

  • Cho, Seong-Yun;Park, Chan-Gook
    • ETRI Journal
    • /
    • v.27 no.4
    • /
    • pp.418-426
    • /
    • 2005
  • A calibration technique for a redundant inertial measurement unit (IMU) containing low-grade inertial sensors is proposed. In order to calibrate a redundant IMU that can detect and isolate faulty sensors, the fundamental coordinate frames in the IMU are defined and the IMU error is modeled based on the frames. Equations to estimate the error coefficients of the redundant IMU are formulated, and a test sequence using a 2-axis turntable is also presented. Finally, a redundant IMU with cone configuration is implemented using low-grade inertial sensors, and the performance of the proposed technique is verified experimentally.

  • PDF