• 제목/요약/키워드: Industrial thermometer

검색결과 20건 처리시간 0.029초

Analysis of characteristics of discharge in liquid

  • Kim, Ju-Sung;Min, Boo-Ki;Hong, Young-June;Kang, Seong-Oun;Choi, Eun-Ha
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.209.2-209.2
    • /
    • 2016
  • Up to now, Plasma applications are thought as a leading technology in industrial, chemical and even medical and biological field. Especially, Due to direct discharge in liquid with reaction in ambient solution, plasma in liquid is useful plasma technology. Such as electro-surgery, water purification, radical generation for synthesis. For using those plasma applications efficiently, plasma characteristics should be understood in advance. But discharge in liquid is not much well-known about its characteristics. And plasma discharge in solution is difficult to generate and analysis due to electrolysis, vaporization and radical generation. So, We make stable plasma discharge in solution(saline 0.9%) without input gas. We also analyze new type of plasma source in thermal and electrochemical view. And we check characteristics of plasma in liquid. For example, plasma density and radical density(OH) with optical emission, thermal energy with thermometer, electrical energy with oscilloscope and so on. And we try to explain the bubble and plasma formation with circuit analysis.

  • PDF

저온프로세스를 이용한 고분자필름의 플라즈마 표면처리 (Plasma Surface Treatment of the Polymeric Film with Low Temperature Process)

  • 조욱;양성채
    • 한국전기전자재료학회논문지
    • /
    • 제21권5호
    • /
    • pp.486-491
    • /
    • 2008
  • The plasma processing is applied to many industrial fields as thin film deposition or surface treatment technique. In this study, we investigated large-area uniformed surface treatment of PET film at low temperature by using Scanning Plasma Method(SPM). Then, we measured difference and distribution of temperature on film's surface by setting up a thermometer. We studied the condition of plasma for surface treatment by examining intensity of irradiation of uniformed plasma. And we compared contact angles of treated PET film by using Ar and $O_2$ plasma based low temperature. In our result, surface temperature of 3-point of treating is low temperature about $22^{\circ}C$, in other hands, there is scarcely any variation of temperature on film's surface. And by using Ar plasma treatment, contact angle is lower than untreatment or $O_2$ plasma treatment. In case of PET film having thermal weak point, low temperature processing using SPM is undamaged method in film's surface and uniformly treated film's surface. As a result, Ar plasma surface treatment using SPM is suitable surface treatment method of PET film.

특이점 분석에 의한 노건조된 흙의 건조무게 측정에 관한 실험적 연구 (Experimental Study of the Oven Dried Soil Weight Measurement Using Singularity Analysis)

  • 김석주
    • 한국지반환경공학회 논문집
    • /
    • 제24권3호
    • /
    • pp.5-14
    • /
    • 2023
  • 흙의 건조단위중량은 노건조된 흙의 무게를 측정하여 구할 수 있다. 한국산업표준(KS F)의 규정에 의해 110±5℃로 노건조된 흙은 공기 중에 노출 시 무게가 지속적으로 증가한다. 그러나, 노건조된 흙의 무게 측정 시간에 대한 규정이 없어 정확한 건조무게를 측정하는데 어려움이 있다. 본 연구에서는 무게 측정 시 나타나는 무게 특이점의 분석을 통해 건조무게를 쉽게 결정할 수 있는 방법을 제시하였다. 무게 특이점은 측정된 무게 중 가장 작은 값을 나타내며, 시료의 공기 중 수분 흡수의 영향이 최소화된 무게이다. 실험 과정에서 통계적 분석법을 이용하여 용기를 선택하였고, 광학현미경을 사용하여 시료의 사진을 제시하였다. 또한, 비접촉식 적외선 온도계를 사용하여 무게 특이점의 발생 온도를 측정하였다. 주문진 모래와 내성천 모래, 예천 화강풍화토, 제주도 모래, 사브카 모래, 울릉도 모래 등 6종류의 흙에 대하여 무게 특이점을 분석한 결과, 노건조된 각 시료의 무게 특이점은 무게 측정 후 8~27초 사이에서, 온도는 103.4~108.13℃의 범위에서 나타났다. 특이점의 무게 감소율은 흙 시료에 따라 0.0066~0.0085%로 나타났다.

드론을 활용한 교면포장 품질관리 방안에 관한 연구 (A Study on the Quality Control Plan for Bridge Pavement using drones)

  • 송미화;길흥배
    • 한국융합학회논문지
    • /
    • 제13권5호
    • /
    • pp.1-8
    • /
    • 2022
  • 국내에서는 4차 산업혁명의 핵심기술인 드론 등을 이용하여 사회기반시설(SOC)를 디지털화하는 한국판뉴딜 정책을 추진 중에 있고, 국외에서도 열화상카메라 등 융복합센서를 드론에 탑재하여 다양한 산업 분야에서 활용하는 사례가 증가하고 있다. 본 연구에서는 고속도로 교면포장 공사에서 포장 품질을 개선하기 위하여 드론에 열화상 카메라를 탑재하여 포장 작업 구간에 대한 온도 측정 및 검증을 수행하였다. 기존의 방식인 레이저 온도계를 활용한다면 포장 온도를 부분적으로만 측정이 가능하지만, 제안된 방식을 활용하면 포장 작업 구간 전체에 대한 실시간 온도 모니터링 뿐 아니라 온도 분포 확인을 통한 균일성 검증이 가능한 것을 확인하였다. 제안된 방식을 현장에 적용한다면 도로 개방 시기(포장 표면온도≦40℃)에 대한 오판의 가능성을 낮춰줌에 따라 고속도로 포장 품질관리 제고 및 신속한 교통 개방 시기 결정이 가능할 것으로 기대된다.

강제 흡출식 복사선 차폐장치가 온실의 기온측정에 미치는 영향 (Effects of an Aspirated Radiation Shield on Temperature Measurement in a Greenhouse)

  • 정영균;이종구;윤성욱;김현태;안은기;서재석;윤용철
    • 생물환경조절학회지
    • /
    • 제28권1호
    • /
    • pp.78-85
    • /
    • 2019
  • 본 연구에서는 본 연구실에서 자체적으로 제작한 비교적 제작이 간편하고 비용이 저렴한 강제 흡출식 복사선차폐장치(Aspirated Radiation Shield; ARS)로 측정한 실측 데이터를 바탕으로 장치의 성능과 온도 및 상대습도의 측정오차에 대하여 보고하고자 연구를 수행하였다. 그 결과를 요약하면 다음과 같다. ARS장치와 진주기상대에서 측정한 최대, 평균 및 최저온도의 범위는 각각 $2.0{\sim}34.1^{\circ}C$$0.4{\sim}31.5^{\circ}C$, $-6.1{\sim}22.2^{\circ}C$$-5.8{\sim}22.0^{\circ}C$, $-14.1{\sim}16.3^{\circ}C$$-14.0{\sim}15.1^{\circ}C$범위로 나타났다. 최대기온의 최저 및 최고온도에서 각각 $1.6^{\circ}C$$2.6^{\circ}C$정도 교내에서 측정한 값이 약간 높게 나타난 것을 제외하면, 두 기관에서 측정한 온도에 큰 차이가 없는 것을 알 수 있었다. 표준온도계의 측정값과 검증한 결과, ARS장치로 측정한 온도가 표준온도계에 비해 $-2.0^{\circ}C$정도 낮거나 $1.8^{\circ}C$보다 높게 나타나났다. 표준온도계와 상관분석 한 결과, 결정계수는 0.99정도였다. 팬의 유무에 따른 온도의 경우, 전체적으로 팬이 없는 경우가 최고, 평균 및 최저온도가 각각 $0.5{\sim}7.6^{\circ}C$, $0.3{\sim}4.6^{\circ}C$$0.5{\sim}3.9^{\circ}C$정도 높게 나타났다. 그리고 ARS장치와 진주기상대에서 측정한 일평균 상대습도는 전체적으로 ARS장치로 측정한 값이 약간 높은 경향이 있고, 특히 상대적으로 6월 27일, 7월 26일, 29일, 8월 20일에 측정한 값이 각각 5.7%, 5.2%, 9.1% 및 5.8%정도로 다소 높게 나타났지만, 두 기관의 월별 평균치는 2.0~3.0%정도로 미미한 수준이었다. 또한 ARS장치와 아스만 통풍습도계로 측정한 상대습도는 전체적으로 -3.98~+7.78%정도의 범위 내에 있는 것으로 나타났다. 진주기상대와 아스만 통풍습도계로 측정한 상대습도를 상관분석 결과, 결정계수가 각각 0.94 및 0.97정도로써 높은 상관관계를 보였다.

스위칭 잡음 감소기법을 이용한 10비트 80MHz CMOS D/A 변환기 설계 (Design of The 10bit 80MHz CMOS D/A Converter with Switching Noise Reduction Method)

  • 황정진;선종국;박리민;윤광섭
    • 대한전자공학회논문지SD
    • /
    • 제47권6호
    • /
    • pp.35-42
    • /
    • 2010
  • 본 논문에서는 무선 통신 응용 시스템에 적합 하도록 10비트 80MHz 전류구동 방식의 D/A 변환기를 제안하였다. 제안한 회로는 $0.18{\mu}m$ CMOS n-well 1-poly 6-metal 공정을 이용하여 구현하였다. 10비트 중에서 LSB 4비트는 이진 디코더를 사용 하였으며, ULSB 3비트와 MSB 3비트는 온도계 디코더를 사용한 혼합구조를 채택하였다. 구현된 D/A 변환기의 측정결과, 샘플링 주파수가 80MHz, 입력 주파수 1MHz에서 SFDR은 60.42 dBc, 유효비트수는 8.75 비트를 보여주었다. INL/DNL은 ${\pm}$0.38LSB/${\pm}$0.32LSB로 측정되었으며, 글리치 에너지는 4.6 $pV{\cdot}s$로 나타났다. 전력 소모는 1.8V 전원전압에서 최대 속도인 80MHz일 때 48mW로 측정되었다.

가열 처리에 따른 커틀릿의 식품안전성 확보 조건 - 내부 중심온도, 색도 및 위생지표미생물을 중심으로 - (Effect of Cooking on the Food Safety of Cutlet - Changes of Internal Temperature, Color, and Indicator Organisms -)

  • 김종규;김중순
    • 한국환경보건학회지
    • /
    • 제41권2호
    • /
    • pp.82-89
    • /
    • 2015
  • Objectives: This study was performed to investigate the effect of cooking time on the internal temperature and color of cutlets and the reduction of indicator organisms in cutlets by cooking. Methods: Three kinds of commercially packed frozen cutlets (pork, chicken and fish cutlets), were purchased from local markets. The cutlets were cooked in a frying pan at $180^{\circ}C$ for four minutes. Internal temperature was measured with a food thermometer. Color was measured using a Hunter spectrocolorimeter. Aerobic colony counts, coliforms, and Escherichia coli were determined according to the Food Code of Korea. Results: The internal cooked temperature of every cutlet reached over $74^{\circ}C$, the temperature considered safe, after three minutes, while external temperature reached this level in two minutes (p < 0.001). The instrumental color value as lightness (L) in the cooked cutlets significantly changed (p < 0.001) after one minute. The level of aerobic colony counts of fresh cutlets was under the specification and was reduced to one tenth its level in the cooked cutlets. Coliforms and E. coli were not detected in all samples. The internal temperature of the cutlets was significantly affected by cooking time and weight (p < 0.001). The interaction effect of time and weight was also significant (p < 0.001), and time was the more influential factor. Conclusion: The results of this study indicate that the sampled cutlets should be cooked for a minimum of three minutes or more in order to ensure food safety. The results also indicate that if consumers cease cooking based on external temperature or color, there will be a risk of inadequate cooking.

조리과정 중 중심부 온도의 변화 - 만두를 중심으로 (Changes of Internal Temperature during the Cooking Process of Dumpling (Mandu))

  • 김종규;김중순
    • 한국생활과학회지
    • /
    • 제22권3호
    • /
    • pp.485-492
    • /
    • 2013
  • The temperature changes of dumpling(mandu) during cooking process were examined and the effects of time-temperature and/or time-size interactions on internal temperature were studied. Mandu was purchased from local markets and classified by its weight(small, medium, and large). Boiling, steaming, pan frying, and deep fat frying were adopted. Internal temperature was measured with a food thermometer in every one minute. The internal temperature of mandu increased over time in every cooking process(p<0.05). After three minutes the internal temperature of mandu in boiling, pan frying, and deep fat frying reached over at $74^{\circ}C$, which is high enough temperature to kill the harmful bacteria, but not in steaming. The internal temperature of mandu was significantly affected by cooking time, size, and both in boiling, steaming, and deep fat frying(p<0.05). There were significant differences between the internal and surface temperatures of mandu in the cooking processes except pan frying in three minutes(p<0.05). The results of this study indicate three minutes' cooking of the mandu by boiling, pan frying, and deep fat frying is safe enough to eat. However, longer steaming time is needed in order to reach safe temperature. This study also indicates the cooking time and size of mandu appear to be major factors in determining the internal temperature achieved at $74^{\circ}C$. More research is needed to check time to reach a safe temperature in the cooking process of mandu by steaming.

마이크로 프로세서 기반 Lock-In-Amp를 이용한 텍스타일 직물전극의 체온 측정에 관한 연구 (A Study on Body Temperature Measurement of Woven Textile Electrode Using Lock-In-Amp based on Microprocessor)

  • 이강휘;이성수;이정환;송하영
    • 전기학회논문지
    • /
    • 제66권7호
    • /
    • pp.1141-1148
    • /
    • 2017
  • Generally, a thermistor made by sintering a metal oxide is widely used to measure the ambient temperature. This thermistor is widely used not only for industrial use but also for medical use because of its excellent sensitivity, durability, temperature change characteristics and low cost. In particular, the normal body temperature is 36.9 degrees relative to the armpit temperature, and it is most closely related to the circulating blood flow. Previous studies have shown that body temperature changes during biomechanical changes and body temperature changes by anomalous signs or illnesses. Therefore, in this study, we propose a Lock-In-Amp design to detect minute temperature changes of clothing and thermistor wired by a preacher as a method to regularly measure body temperature in daily life. Especially, it is designed to measure the minute resistance change of the thermistor according to body temperature change even in a low-cost microprocessor environment by using a micro-processor-based Lock-In-Amp, and a jacquard and the thermistor is arranged so as to be close to the side, so that the reference body temperature can be easily measured. The temperature was measured and stored in real time using short-range wireless communication for non - restraint temperature monitoring. A baby vest was made to verify its performance through temperature experiments for infants. The measurement of infant body temperature through the existing skin sensor or thermometer has limitations in monitoring infant body temperature for a long time without restriction. However, it can be overcome by using the embroidery fabric based micro temperature monitoring wireless monitoring device proposed in this study.

옥상 색상에 따른 쿨루프 성능평가를 위한 여름철 옥상 표면 및 실내온도 비교 분석 : 무인항공기에 장착된 열적외선 카메라를 이용하여 (Comparison of Rooftop Surface Temperature and Indoor Temperature for the Evaluation of Cool Roof Performance according to the Rooftop Colors in Summer: Using Thermal Infrared Camera Mounted on UAV)

  • 이기림;성지훈;한유경;이원희
    • 한국측량학회지
    • /
    • 제37권1호
    • /
    • pp.9-18
    • /
    • 2019
  • 전 세계적으로 지구온난화현상이 심화되고 있으며, 특히 우리나라의 경우 급격한 산업 발전 등으로 인해 도시화가 진행되면서 도시열섬현상까지 발생되고 있다. 이렇게 도시의 온도가 상승하게 되면 주거 생활의 쾌적성 및 냉방부하와 같은 문제 등을 야기한다. 본 연구에서는 이러한 문제를 줄이기 위해 지붕 색상에 따른 쿨루프 성능 평가를 진행하였으며, 기존의 평지붕 축소 모형, 손잡이 형태의 열화상 카메라 또는 레이저 온도계를 이용하지 않고, 실제 건물과 UAV에 열적외선 카메라를 장착하여 원격탐사 기법으로 옥상 색상 (흰색, 회색, 초록색, 청색, 갈색, 검은색)에 따른 표면 온도를 취득하였다. 그 결과 흰색을 적용한 표면 온도가 다른 색상보다 11도에서 20도 낮게 나타났으며, 에어컨의 실내 온도와 디지털 온도계의 실내 온도 또한 흰색의 색상이 다른 색상보다 약 1.5도에서 4.4도, 약 1.5도에서 3.5도 낮게 측정되었다. 이를 통해 흰색이 쿨루프 성능이 가장 좋음을 확인할 수 있었으며, UAV와 열적외선 카메라를 통해 기존 다른 연구에서 사용했던 방법보다 신속하고, 편리하게 쿨루프 성능 평가가 가능함을 확인할 수 있었다.