• Title/Summary/Keyword: Industrial point source

Search Result 169, Processing Time 0.025 seconds

A Software Vulnerability Analysis System using Learning for Source Code Weakness History (소스코드의 취약점 이력 학습을 이용한 소프트웨어 보안 취약점 분석 시스템)

  • Lee, Kwang-Hyoung;Park, Jae-Pyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.11
    • /
    • pp.46-52
    • /
    • 2017
  • Along with the expansion of areas in which ICT and Internet of Things (IoT) devices are utilized, open source software has recently expanded its scope of applications to include computers, smart phones, and IoT devices. Hence, as the scope of open source software applications has varied, there have been increasing malicious attempts to attack the weaknesses of open source software. In order to address this issue, various secure coding programs have been developed. Nevertheless, numerous vulnerabilities are still left unhandled. This paper provides some methods to handle newly raised weaknesses based on the analysis of histories and patterns of previous open source vulnerabilities. Through this study, we have designed a weaknesses analysis system that utilizes weakness histories and pattern learning, and we tested the performance of the system by implementing a prototype model. For five vulnerability categories, the average vulnerability detection time was shortened by about 1.61 sec, and the average detection accuracy was improved by 44%. This paper can provide help for researchers studying the areas of weaknesses analysis and for developers utilizing secure coding for weaknesses analysis.

Management of Nonpoint Sources in Watershed - with reference to Daechong Reservoir in Korea (수계의 비점오염원 관리 - 대청호를 중심으로)

  • Lee, Jong-Ho
    • Journal of Environmental Impact Assessment
    • /
    • v.9 no.3
    • /
    • pp.163-176
    • /
    • 2000
  • The purpose of this study is to analyze the pollutant loads and its distribution, and to suggest the management of nonpoint sources in Daechong Reservoir. The loads from point and nonpoint sources such as population, industry, livestock and land use were calculated per stream or river with topography(1:25,000) of the watershed of Daechong Reservoir. The generating pollutant loads were obtained through multiplication of pollutant sources by generating pollutant quantity per unit pollutant source. The effluent point sources loads is defined as loads from wastewater treatment facilities such as domestic, industrial and livestock wastewater treatment facilities, which were calculated through multiplication of effluent flowrates by water quality constituents concentration. Untreated point sources loads were estimated to be 35 % of total point sources loads. The effluent nonpoint sources pollutant loads were obtained through the multiplication of generating nonpoint sources loads by effluent ratios based on previous studies. The effluent nonpoint sources loads have the ratio of 26.2% of total BOD effluent loadings, 20.1% of total T-N effluent loadings, and 10.5% of total T-P effluent loadings. For the reduction of nonpoint sources loads in Daechong Reservoir, silviculture, artificial wet land, and grassed waterways could be applied. And untreated livestock waste scattered can result in nonpoint loadings, so required the livestock wastes treatment facilities and purifying facilities together with the management of shed, pasture, livestock waste storage site and composting site. Finally, remote sensing and GIS should be applied to the identification of distribution of water quality, watershed, the location and scale of nonpoint sources, effluent process during rainfall, for more detailed analysis of nonpoint sources.

  • PDF

DC-link Voltage Control of Grid Connected PV System using Quasi Z-Source Inverter (QZSI를 이용한 계통연계형 태양광발전 시스템의 직류단 전압제어)

  • Park, Jong-Hyoung;Kim, Heung-Geun;Nho, Eui-Cheol;Chun, Tae-Won;Cha, Honnyong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.3
    • /
    • pp.201-210
    • /
    • 2014
  • In this paper, dc-link voltage control of a grid-connected QZSI is presented. Since the input current of the ZSI is discontinuous, a capacity with relatively large capacitance should be connected to the output of the PV array in order to reduce the current ripple. Due to the presence of the impedance network inductor in series with the PV array, the QZSI can achieve continuous input current flow. Several dc-link voltage control methods are compared and the method for power quality improvement is also presented. The performance of the proposed method is verified through both simulation and experimental results.

Characteristics on the Neutral Point Potential of Line-to-Ground Voltage according to Line-to-Ground Fault in Resistance Ground System for Ships (선박의 저항접지 시스템에서 지락 고장에 따른 대지전압 중성점 전위 특성)

  • Lee, Yun-Hyung;Ryu, Ki-Tak
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.5
    • /
    • pp.689-696
    • /
    • 2018
  • System grounding is applied to the neutral point of a power source to secure the from any abnormal voltage and/or grounding fault. System grounding, which is applied mainly in ships is an ungrounded and resistance grounded system. Vessels using the MV power system with 3.3kV, 6.6kV, and 11kV mainly adopt a high resistance grounding system among the resistance grounding systems. The ground fault accounts for 95% of all faults occurring in the electrical system and when a fault occurs, the line-to-ground voltage of the power system is increased excessively, which adversely affects the onboard insulation system. This study analyzed the variation characteristics of the line-to-ground voltage neutral point according to the degree of ground fault in a resistance ground system applied in vessels. For this purpose, the characteristics of the grounding system were first explained, and the modeling of the neutral point potential of the line-to-ground voltage of the resistance grounding system in the vessels was derived. Finally, this study examined how the line-to-ground voltage, line voltage, and neutral point change according to various variable environments through MATLAB simulations.

Case Analysis on High Concentration of SO2 and Review on Its Reduction Policy in the Ulsan Metropolitan Area since 2001 (울산 지역에서 2001년 이후 이산화황(SO2)의 고농도 사례 분석과 저감 정책 방안의 검토)

  • Moon, Yun-Seob
    • Journal of Environmental Science International
    • /
    • v.17 no.4
    • /
    • pp.423-437
    • /
    • 2008
  • Until comparatively lately, the annual time series of the $SO_2$ concentration had been shown in a decreasing trend in Ulsan as well as other Korean cities. However, the high concentration of $SO_2$ was frequently found in the specific countermeasure region including the national industrial complex such as Mipo and Onsan in the Ulsan city for the period of $2001{\sim}2004$. There are many conditions that can influence the high concentration of $SO_2$ at monitoring sites in Ulsan, such as: First, annual usage of the fuel including sulfur increased in comparison with the year before in spite of the fuel conversion policy which wants to use low sulfur oil less than 3% and LNG. Second, point source, such as the power plants and the petroleum and chemistry stacks, was the biggest contributor in $SO_2$ emission, as a analyzed result of both the air quality modeling and the stack tole-monitoring system (TMS) data. And third, the air pollutants that occurred in processes of homing and manufacturing of the fuel including sulfur were transported slow into a special monitoring site by accumulating along the frontal area of see-breeze. It was concluded that Ulsan's current environmental policy together with control methods should be changed into the regulation on total amount of emission, including a market-based emission trading with calculating of atmospheric environmental critical loads, for the $SO_2$ reduction like the specific countermeasure for the $O_3$ and PM10 reduction in the Seoul metropolitan area. And this change should be started in the big point sources of $1{\sim}3$ species because they are big contributors of Ulsan's $SO_2$ pollution. Especially it is necessary to revitalize of the self-regulation environmental management. Other control methods for sustaining the $SO_2$ reduction are as follows: maintenance of the fuel conversion policy, reinforcement of the regional stationary source emission standard, and enlargement of the stack TMS.

Management of water quality by estimated the point source in Mokpo inner bay (점 오염원 조사를 통한 목포 내항의 수질관리)

  • Kim, Do-Hee;Lee, Ha-Ju
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2006.05a
    • /
    • pp.121-128
    • /
    • 2006
  • The results of COD researched on August of 2004 were 6.8 ppm in North Mokpo inner Bay, 4.4 ppm in front of YongSang Bank and 4.6 ppm in front of ShinAn Beach Hotel which is over III level Marine-Environmental Standard. The other five stations sea water quality of Mokpo inner bay were reached II-III level. Concentration of total nitrogen range from 1.23 ppm to 3.56 ppm and total phosphorous was range from 0.07 ppm to 0.12 ppm which were II-III level. This results show that the Mokpo inner bay is unsuitable for aquaculture and growth of fish and for use of marine resort, it can be only available for industrial and harbour use. In results of estimated point source flow into Mokpo inner bay, the occupation ratio from YoungSang river in total inflow of TN and TP were up to 49-89 % respectively. It is indicate that in order to improve the water quality of MokPo inner bay have to control the discharge from YoungSang river first of all, then control the discharge from North Harbour domestic wastewater treatment, InAm river and NamHae domestic wastewater treatment.

  • PDF

Management of Water Quality by the Point Source in Mokpo Inner Bay (점 오염원 조사를 통한 목포 내항의 수질관리)

  • Kim, Do-Hee
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.12 no.4 s.27
    • /
    • pp.273-283
    • /
    • 2006
  • The results of COD concentration on August of 2004 were 6.80 ppm in North Mokpo Inner Bay, 4.42 ppm un front of YongSang Bank and 4.60 ppm in front of ShinAn Beach Hotel which is over III level Marine Environmental Standard. The others researched five stations sea water quality of Mokpo inner bay are reached II-III level. The concentration of total nitrogen range from 1.23 ppm to 3.56 ppm and total phosphorous concentration was range from 0.07 ppm to 0.12 ppm which are to be II-III level. This results show that the Mokpo inner bay is unsuitable for aquaculture and for use of marine resort, it can be only avaliable for industrial and harbour port use. In this study, we researched 12 point source flow into Mokpo Inner bay. The rate from YoungSang river in total inflow of TN was up to 70-93 % and rate of TP was up to 31-91 % respectively. In this results, we have to control the discharge from YoungSang river first of all then control the discharge from North Harbour domestic wastewater treatment, InAm river and NamHae domestic wastewater treatment in order to improve the water quality of Mokpo Inner bay.

  • PDF

Effects of the Brazing Bonding between Al2O3 and STS304 with an Ion Beams (이온빔을 이용한 STS304와 알루미나 브레이징 접합효과)

  • Park, Il-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.12
    • /
    • pp.8679-8683
    • /
    • 2015
  • Using a surface modification technique, ion beam assisted deposition (IBAD) of Ti thin film it becomes possible to prepare an active ceramic surface to braze $Al_2O_3$-STS304 with conventional Ag-Cu eutectic composition filler metal. Researches on bonding formations at interfaces of ceramic joints were mainly related on the development of filler metals to ceramic, the process parameters, and clarifications of reaction products. From the results, the reactive brazing is a very convenient technique compared to the conventional Mn-Mo method. However melting point of reactive filler is still higher than that of Ag-Cu eutectic and it forms the brittle inter metallic compound. Recently several new approaches are introduced to overcome the main shortcomings of the reactive metal brazing in ceramic-metal, metal vapor vacuum arc ion source was introduced to implant the reactive element directly into the ceramics surface, and sputter deposition with sputter etching for the deposition of active material.

Status of Water Quality and Future Plans in the Philippines (필리핀의 수질현황 및 미래 관리계획)

  • Gorme, Joan B.;Maniquiz, Marla C.;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.11 no.3
    • /
    • pp.89-103
    • /
    • 2009
  • The Philippines is abundant with rich natural resources such as water. Because of rapid urbanization in the country, most of the water bodies are polluted as a result of domestic, agricultural and industrial activities. The Environmental Management Bureau (EMB) is the main government arm responsible for monitoring and inspection of affected water bodies. Only water bodies with at least four sampling events during dry and wet seasons were included in the assessment of water bodies that passed the DAO 90-34 water quality criteria. Water bodies were monitored for dissolved oxygen (DO), biochemical oxygen demand (BOD), total suspended solids (TSS), and total dissolved solids (TDS), heavy metals, fecal coliform contamination and nitrates. High pollutant concentrations from domestic, agricultural, industrial and nonpoint sources were observed from monitoring events due to inadequate sewage services and treatment facilities in the country. The objective of this paper was to present and evaluate the quality of the water bodies in the Philippines.

  • PDF

Performance Evaluation of Multi-path Source Routing Protocol according to Mobility Model (이동성 모델에 따른 다중경로 소스 라우팅 프로토콜의 성능평가)

  • Kim, Su-Sun;Kim, Moon Jeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.8
    • /
    • pp.5559-5564
    • /
    • 2015
  • A variety of routing protocols targeted specifically at mobile ad-hoc network environments have been developed. Mobile ad-hoc network is a self-organizing temporary network, operating without the aid of any established wired infrastructure. The proposed protocol supports seamless communication services between the mobile hosts within a mobile ad-hoc network environments. In particular, our protocol makes faster route re-establishment possible by maintaining multiple paths in each mobile host, and also, the protocol provides reliable communication environments. We compare the performance of RWP model with that of LW model. This paper shows delivery ratio with single path and non-disjoint multiple path according to mobility model and node numbers.