• Title/Summary/Keyword: Industrial energy demand

Search Result 305, Processing Time 0.03 seconds

Effect of economic growth, industrial structure, efficiency improvement, decarbonization of power sector and fuel substitution for the transition to low carbon society by 2050 (2050년 저탄소 사회로의 전환을 위한 경제성장, 산업구조, 효율개선, 전력 탈탄소화와 연료 대체의 효과)

  • Park, Nyun-Bae;Hong, Sungjun;Park, Sang Yong
    • Journal of Energy Engineering
    • /
    • v.23 no.4
    • /
    • pp.61-72
    • /
    • 2014
  • This paper analyzed transition pathways toward a low carbon society in Korea to meet global $2^{\circ}C$ climate target. Lower economic growth, industrial structure change, enhance of energy demand management, decarbonization of power sector, and replacement of low carbon fuel could reduce greenhouse gas (GHG) emission from fuel combustion in 2050 by 67% against in 2011, or by 74% against in BAU (Business-As-Usual). Lower economic growth contributes to 13% of cumulative emission reduction relative to BAU, industrial structure change 9%, enhance of energy demand management 72%, decarbonization of power sector 5% and replacement of low carbon fuel 1% respectively. Final energy consumption in 2050 needs to be reduced to 50% relative to 2011, or to 41% relative to BAU. Nuclear, coal and renewable energy represent 31%, 40%, 2% respectively among electricity generation in 2011, but 38%, 2%, 32% in 2050. CCS represents 23% of total generation in 2050. Emission intensity of electricity in 2050 was decreased to 19% relative to 2011, or to 24% relative to BAU. Primary energy in 2050 was decreased to 64% compared to 2011, or to 44% compared to BAU. Final energy consumption, primary energy supply and GHG emission from fuel combustion from 1990 to 2011 increased by 176%, 197%, 146%. Radical change from historical trend is required to transit toward a low carbon society by 2050. Appropriate economic growth, structural change to non-energy intensive industries, energy technology research, development and deployment (RD&D) in terms of enhancement of energy efficiency and low carbon energy supply technologies, and fuel change to electricity and renewable energy are key instruments.

A Development of Energy saving System using Voltage Adjustment (자동전압조정형 에너지 절약장치 개발)

  • Koo, Heun-Hoi;Byon, Young-Bok;Kim, Yo-Hee;Choi, Jang-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.812-814
    • /
    • 1993
  • During the last two decades, we experienced a few of the energy shocks and felt the importance of the energy saving seriously. As our energy reliance on other countries is absolute. We must counter these situations nationally. To save the electric energy, various methods are explored such as the moderation of motor capability, the use of high efficiency system, the supervision of lighting systems, demand monitoring control systems. In this study, we develop a system for electric power energy saving. In Case the receiving point voltage is higher than the required voltage, the system reduce the voltage to an allowable level and by doing so it saves energy and protects the equipments from over voltage.

  • PDF

Computational Analysis of Structural Behavior of Subsea Pipelines with Local Corrosion (국부 부식을 가지는 심해저 파이프라인의 구조응답에 대한 전산 해석적 연구)

  • Choi, Kwang-Ho;Lee, Chi-Seung;Ryu, Dong-Man;Koo, Bon-Yong;Song, Joon-Kyu;Lee, Jae-Myung
    • Journal of Ocean Engineering and Technology
    • /
    • v.29 no.1
    • /
    • pp.100-110
    • /
    • 2015
  • To meet the increasing demand for energy around the world, offshore and subsea energy development is constantly being conducted. This trend is accompanied by an increasing demand for pipeline installation, which brings numerous problems, including those related to accessibility, high pressure, and corrosion. Among these, corrosion is a primary factor in pipeline fractures, and can cause severe environmental and industrial damage. Hence, accurate corrosion assessment for corroded pipelines is very important. For this reason, the present study investigated the mechanical behavior of an idealized corroded subsea pipeline with an internal/external pressure load using the commercial FEA code ABAQUS. Then, the analysis result was compared with corrosion assessment codes such as ASME B31G, DNV RP F101, ABS. Finally, a fitness-for-service assessment was conducted.

Study on TES system application for industrial production facility (축냉시스템의 산업용 생산설비 적용에 대한 고찰)

  • Park, C.H.;Hong, S.S.;Kim, J.R.;Park, S.S.;Hwang, H.S.
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1288-1293
    • /
    • 2009
  • The TES (Thermal Energy Storage) cooling system utilizing cheaper off-peak electricity has been applied just for building air-conditioning currently and causes limitation of usage rate and inefficiency of national resources utilization. In this regard, more says the necessity to apply TES system in industrial cooling system which is longer using period and wider usage. In this study, we will approve the technical and economical improvement in efficiency of industrial cooling system applied TES system by utilizing cheaper off-peak electricity and it will attribute the promotion of TES system and stabilization of supply and demand of electric power by proving the necessity to develop more efficient industrial cooling system by combining TES system.

  • PDF

Effects of Ground Calcium Carbonate Dispersion by Sodium Polyacrylate (폴리아크릴산 소다에 의한 중질 탄산칼슘의 분산효과)

  • Ro, Yoon-Chan;Jeong, Tae-Young;Cho, Kyoung-Haeng;Roh, Seung-Ho;Nam, Ki-Dae
    • Journal of the Korean Applied Science and Technology
    • /
    • v.10 no.1
    • /
    • pp.49-55
    • /
    • 1993
  • Ground Calcium Carbonate, among paper coating pigments, will influence less dispersant demand, less binder demand, increase coating solids from 58% to 70%, which means high speed coating, less shrinkage during drying, less energy consumption, more uniform coverage of fibers. The quality point of view of Ground Calcium Carbonate, brightness, particle size, Particle size distribution, hardness, impurities content are important. More important factors of Ground Calcium Carbonate which influence the paper coating process are dispersion mechanisms and their effects. The study was made to investigate the effect of Ground Calcium Carbonate dispersion by sodium salt of polyacrylate dispersant composition and dispersion condition. Basic tests such as physical, optical and chemical were perfumed, and dispersion effects were investigated by different conditions. The results showed that the type of dispersant affected the dispersion effects, and the Ground Calcium Carbonate has critical dispersant demand.

Energy Cost Saving Control of Water Reuse Pumping System Using Particle Swarm Optimization (PSO를 이용한 물 재이용 펌프시스템의 에너지 비용 제어)

  • Boo, Chang-Jin;Kim, Ho-Chan;Kang, Min-Jae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.1
    • /
    • pp.860-867
    • /
    • 2015
  • This paper presents a control method for energy cost saving in the water reuse pumping system. An optimize horizon switching strategy is proposed to implement an pump control. And Particle Swarm Optimization (PSO) algorithm is used to solve optimal problems in each time step. Energy costs are calculated for electricity on both TOU in the light, heavy, and maximum load time period and peak charges. The control method in water reuse pumping systems is determined to reduce the TOU cost. The simulation results show a energy cost saving for water reuse pumping systems.

Intelligent Energy (지능형 에너지)

  • Oh, D.K.;Ji, H.G.;Kim, Y.H.;Kang, M.K;Choi, B.G;Lee, I.W.;Lee, B.T.;Kim, B.U.;Hong, T.C.;Sung, D.K.
    • Electronics and Telecommunications Trends
    • /
    • v.33 no.4
    • /
    • pp.92-102
    • /
    • 2018
  • On a global level, the energy problem is a very important policy topic, particularly at a time when the nation relies on imports for more than 95% of its energy demand. The starting point of an energy policy should be in line with the international community's concern and cooperation regarding climate warming, and the logic of the new policy on renewable energy expansion in Korea, the pre-developed energy sector, and policy of deserting coal all support this aspect. In particular, to accommodate the rapid urbanization of mankind, the key words of the 4th Industrial Revolution are linking energy to IoT, artificial intelligence, block chain, cloud, and big data.

A study on the Energy resource in School Buildings with the Changes of Educational Facilities Standard (교육 시설기준 변화에 따른 학교건축물의 에너지원 변화에 관한 연구)

  • Kim, Tae-Woo;Lee, Kang-Guk;Hong, Won-Hwa
    • KIEAE Journal
    • /
    • v.10 no.6
    • /
    • pp.73-80
    • /
    • 2010
  • Since the Korean War, Korea has experienced modernization. The population increase by baby booming has asked for more space for educational facilities. In such a situation, the purpose of educational facilities was to accommodate continuously increasing students, rather than seeking for quantitative demands. In addition, in accordance with social changes, educational shifts were required. After the revision of the seventh national curriculum in education in 1997, the school buildings became varied. The design of buildings in accordance with educational curriculum has been improved, but still lack of forming comfortable environment and considering energy efficiency in school buildings. For the improvement of educational environments, educational media such as TV and computers have been provided, and energy systems, including heating and cooling systems, has been continuously increased. As a result, it appeared that energy use in school buildings and facilities has been steadily increased and that the structure of energy consumption has been also changed, especially with regard to electricity use. Living in the 21st century, human beings face global environmental issues, such as global warming, geographical climate changes, and ozone destruction that are the consequences of fossil energy use. Therefore, even in industrial areas, considering a counterplan for low energy use is being paid attention. Starting with Kyoto Protocol in 1992, people try to decrease carbon dioxide and to develop alternative energies (i.e. natural energy); for example, solar energy, wind force, terrestrial heat, and water power. Advanced countries already set up a criterion for $CO_2$ decrease ranging from office buildings to residential houses and also propose alternatives for the $CO_2$ decrease. However, there is no such a plan for low energy use and $CO_2$ decrease in school facilities, and any research on the actual conditions was not accomplished. Thus, this study examines energy demand in classrooms that take up a large portion of energy demand in school building structure.

Development of Lithium Lanthanum Titanate (LLTO) Membrane Manufacturing Process for Selective Separation of Lithium Ion (리튬이온의 선택적 투과를 위한 Lithium Lanthanum Titanate계 분리막 제조 공정 개발)

  • Young Il Kim;Sang Cheol Park;Kwang Ho Shin;InYeong Kim;Kee-Ahn Lee;Sung-Kyun Jung;Bin Lee
    • Journal of Powder Materials
    • /
    • v.30 no.1
    • /
    • pp.22-28
    • /
    • 2023
  • The global demand for raw lithium materials is rapidly increasing, accompanied by the demand for lithiumion batteries for next-generation mobility. The batch-type method, which selectively separates and concentrates lithium from seawater rich in reserves, could be an alternative to mining, which is limited owing to low extraction rates. Therefore, research on selectively separating and concentrating lithium using an electrodialysis technique, which is reported to have a recovery rate 100 times faster than the conventional methods, is actively being conducted. In this study, a lithium ion selective membrane is prepared using lithium lanthanum titanate, an oxide-based solid electrolyte material, to extract lithium from seawater, and a large-area membrane manufacturing process is conducted to extract a large amount of lithium per unit time. Through the developed manufacturing process, a large-area membrane with a diameter of approximately 20 mm and relative density of 96% or more is manufactured. The lithium extraction behavior from seawater is predicted by measuring the ionic conductivity of the membrane through electrochemical analysis.

Estimation of Reasonable Price of Battery Energy Storage System for Electricity Customers Demand Management (전력소비자 수요관리용 전지전력저장시스템의 적정 가격 산정)

  • Kim, Seul-Ki;Cho, Kyeong-Hee;Kim, Jong-Yul;Kim, Eung-Sang
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.10
    • /
    • pp.1390-1396
    • /
    • 2013
  • The paper estimated the reasonable market price of lead-acid battery energy storage system (BESS) intended for demand management of electricity customers. As time-of-use (TOU) tariffs have extended to a larger number of customers and gaps in the peak and off-peak rates have gradually risen, deployment of BESS has been highly needed. However, immature engineering techniques, lack of field experiences and high initial investment cost have been barriers to opening up ESS markets. This paper assessed electricity cost that BESS operation could save for customers and, based on the possible cost savings, estimated reasonable prices at which BESSs could become a more prospective option for demand management of customers. Battery scheduling was optimized to maximize the electricity cost savings that BESS would possibly achieve under TOU tariffs conditions. Basic economic factors such as payback period and return on investment were calculated to determine reasonable market prices. Actual load data of 12 industrial customers were used for case studies.