• Title/Summary/Keyword: Industrial effluent and Agricultural soil

Search Result 5, Processing Time 0.025 seconds

Effects of Heavy Metals Pollution in Soil and Plant in the Industrial Area, West ALGERIA

  • Tahar, Kebir;Keltoum, Bouhadjera
    • Journal of the Korean Chemical Society
    • /
    • v.55 no.6
    • /
    • pp.1018-1023
    • /
    • 2011
  • Alzinc is a ursine situated in the Ghazaouet town western part of the republic of Algeria. The purpose of this study was to determine the degree of contamination which soil and plants are burdened with some heavy metals: Pb, Zn, Ni, Cu, Cd, Mn, Cr, Fe and As, then the accumulation of heavy metals in the soil and plant adjacent of area the alzinc ursine was detected and the interdependence of pollution among all three regions of the environment determined. This paper analyzes the heavy metal contents within a 2-years period in the soil and plants at the beginning of the vegetation period. The presence of Pb, Zn, Ni, Cu, Cd, Mn, Cr, Fe and As, in the samples were analyzed using Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AES). Measurements of heavy metal contents were performed at three locations in soil and vegetative parts of three-plant types (plant alimentary) period during summer. The plant samples from the immediate environment of the dumpsite were highly contaminated with Zn, Cd and Mn. Three plants species: grape, artichoke and pepper, particularly, grape met some of the conditions to be classified as accumulators for Zn, Cu, Cd and Fe, consequently, she revealed a health risk for human and livestock due to the spread of the metal pollution from waste dumpsites to agricultural areas.

Assessment of Leachate from Solid Waste Landfills in Daechong Lake Upper Drainage Basin (대청호 상류유역 매립지의 침출수 분석 및 평가)

  • Hong, Sang-Pyo
    • Journal of Environmental Impact Assessment
    • /
    • v.12 no.3
    • /
    • pp.161-170
    • /
    • 2003
  • To investigate the characteristics of 17 solid waste landfills in the upper drainage basin of Lake Daechong, the landfill sites were surveyed, the leachate of these landfills were analyzed, and the analysis results were assessed from standpoint of water contamination. Sanitary landfills which are now being operated are relatively well equipped with facilities such as leachate collection, daily soil cover and landfill gas treatment devices. But a few of open-dumping landfills were leaking leachate apparently and were supervised improperly and neglectfully by local governments. Some of sanitary landfills exceeded the COD permission criteria of leachate effluent, and some of open-dumping landfills exceeded SS, T-P, Pb, As, Fe, Mn permission criteria of leachate effluent. To improve the water quality of Lake Daechong which is utilized for supplying drinking water, agricultural water, and industrial water to the great part of Chungchong area, the adequate and prompt measures for preventing Daechong Lake water contamination from landfills leachate is necessary.

Effect of Pollutant Loading and Flow Distance to Wastewater Treatment Efficiency in the Constructed Wetland System (오염부하량 및 유하거리가 인공습지에 의한 폐수처리 효율에 미치는 영향)

  • 김형중;김선주;윤춘경
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.39 no.5
    • /
    • pp.97-108
    • /
    • 1997
  • Natural wastewater treatment systems using the constructed wetland system were evaluated for the wastewater from the industrial complex in rural areas. For the treatment of wastewater from the industrial complex in rural area, a pilot plant of the constructed wetland system was installed at Baeksuk agri-industrial complex in ChunahnCity, Chunchungnam-Do. The experiment with this pilot plants was performed for 1996 and 1997. Results of the study were summarized as follows. For the BOD and COD, when the pollutant loading of them was about 1 3.8g/$m^2$. day (the concentration was l24.0mg/${\ell}$) arid 24.4g/$m^2$.day(the concentration was 220.Omg/${\ell}$), the removal rate of them was high, 90.2% and 93.4%, respectively. For the SS, the effluent concentration was consistently lower than the water quality standard even though the influent concentration varied significantly, which showed that SS was removed by the system effectively which consist of soil and plants. For the T-N and T-P, when the influent pollutant loading of them were moderately high, 2.8g/$m^2$.day to 7.4g/$m^2$. day(concentration 25.0mg/${\ell}$ to 49.7mg/${\ell}$) for T-N and 1.0g/$m^2$.day to 2.6g /$m^2$.day(concentration 8.6mg/${\ell}$ to 14.7mg/${\ell}$) for T-P, the removal rate of them were 86.5% and 94.0%, respectively. The removal rate by the flow distance increased rapidly in the first 4m from the inlet zone, and gradually there after. The width of system was 2m. Overall, the result showed that constructed wetland system is a feasible alternative for the treatment of wastewater from industrial complex in rural areas. Compared to existing systems, this system is quite competitive because it requires low capital cost, almost no energy and maintenance, and therefore, very cost effective.

  • PDF

Natural Treatment of Wastewater from Industrial Complex in Rural Area by Subsurface Flow Wetland System (인공습지에 의한 농공단지 폐수처리)

  • Yoon, Chun-Gyeong;Lim, Yoong-Ho;Kim, Hyung-Joong
    • Korean Journal of Environmental Agriculture
    • /
    • v.16 no.2
    • /
    • pp.170-174
    • /
    • 1997
  • Constructed wetland system was studied to treat wastewater from industrial complex in rural area. Pilot plant at the Baeksuk Nongkong Danzi in Chunahn-City was used for field study. For the DO, the effluent concentration was higher than the influent concentration and it implies that natural reaeration supplies enough oxygen to the system. For the SS, the effluent concentration was consistently lower than the water quality standard even though the influent concentration varied significantly, which showed that SS was removed by the system effectively which is consist of soil and plants. For the BOD and COD, the average removal rate of them were 56% and 43%, respectively, therefore, the effluent concentration could not meet water quality standards when influent concentration was high. The removal rate of BOD and COD can be improved by supplemental treatment in addition to this system if necessary. For the T-N and T-P, the influent concentration of them were lower than the water quality standards than no further treatment was needed. Overall, the result showed that constructed wetland system is a feasible alternative for the treatment of wastewater from industrial complex in rural area. For actual application of this system, further study on design factors including loading rate, removal mechanism, and temperature effects is required to meet water quality standard consistently. Compared to existing systems, this system is quite competitive because it requires low capital cost, almost no energy and maintenance, and therefore, very cost effective.

  • PDF

Development of integrated microbubble and microfilter system for liquid fertilizer production by removing total coliform and improving reduction of suspended solid in livestock manure (가축분뇨 내 대장균 제거와 부유물질 저감 효율 향상을 통한 추비 생산용 미세기포 부상분리와 마이크로 필터 연계 시스템 개발)

  • Jang, Jae Kyung;Lee, Donggwan;Paek, Yee;Lee, Taeseok;Lim, Ryu Gap;Kim, Taeyoung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.139-147
    • /
    • 2021
  • Livestock manure is used as an organic fertilizer to replace chemical fertilizers after sufficient fermentation in an aerobic bioreactor. On the other hand, liquid manure disposal problems occur repeatedly because soil spraying is restricted during the summer when the crops are growing. To use liquid fertilizer (LF) as an additional nutrient source for crops, it is necessary to reduce the amount of suspended solids (SS) in the liquid fertilizer and secure stability problems against pathogenic microorganisms. This study examined the effects of the simultaneous SS removal and E.coli sterilization in the LF using the microbubble (MB) generator (FeMgO catalyst insertion). The remaining SS were further removed using the integrated microbubble and microfilter system. During the floating process in the MB device, the SS were removed by 57.9%, and the coliform group was not detected (16,200→0 MPN/100 mL). By optimizing the HRT of the integrated system, the removal efficiency of the SS was improved by 92.9% under the 0.1h of HRT condition. After checking the properties of the treated LF, 64.5%, 70.1%, 54.9%, and 51.5% of the TCOD, SCOD, PO4-P, and TN, respectively, were removed. The treated effluent from such an integrated system has a lower SS content than that of the existing LF and does not contain coliforms; therefore, it can be used directly as an additional fertilizer.