• Title/Summary/Keyword: Industrial complexes

Search Result 444, Processing Time 0.023 seconds

Quantitative Risk Assessment Method for Metals in Water Body using WASP (WASP 모의를 이용한 하천 수계 중금속 위해성평가 방법)

  • Shin, Yu-Ri;Yoon, Chun-Gyeong;Jeon, Na-Jeong;Rhee, Han-Pil
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.4
    • /
    • pp.629-636
    • /
    • 2010
  • According to the spatial movements of the Nak-dong river watershed, the changes in heavy metal concentrations were simulated by WASP7.3. The risk assessment was performed using the predicted data of WASP7.3. The target heavy metal was manganese (Mn). In the simulated manganese data of WASP7.3, the average concentration by regions was from 0.03 mg/L to 0.07 mg/L. It is lower than drinking water standard in korea. The risk assessment was presented that it was high at the junction of Nak-dong river and Kumho river. It was influenced by the discharge of industrial complexes and large cities which were located in the junction. In comparison of drinking water standard and predicted data of WASP7.3 risk assessment, whole watershed was also low level at predicted data. However, to keep the similar risk value ($10^{-7}$) in adults and children anywhere, it requires the additional treatment of the point source discharges. It was also reflected by regions. Through this study, it was possible to evaluate heavy metal influence in unattainable monitoring regions and to estimate heavy metal addition and reduction by locations. Therefore, the outcomes of WASP7.3 can connect with the risk assessment and it can evaluate the safety of human by regions.

Assessment of the Indoor Air Quality at Schools in Ulsan (울산지역 학교의 실내공기질 평가)

  • Jung, Jong-Hyeon;Seo, Bo-Sun;Ju, Dong-Jin;Park, Man-Chul;Shon, Byung-Hyun;Phee, Young-Gyu
    • Journal of Environmental Health Sciences
    • /
    • v.36 no.6
    • /
    • pp.472-479
    • /
    • 2010
  • The purpose of this study was to investigate the concentration of indoor air pollutants at 63 elementary schools, 41 middle schools and 51 high schools in Ulsan from the beginning of May to the end of December, 2008. To assess the indoor air quality of the various classrooms, the 8 indoor air pollutants such as $CO_2$, CO, $NO_2$, $O_3$, $PM_{10}$, TVOCs, HCHO and TBC were measured and analyzed. The mean concentrations of $PM_{10}$ and TBC in the elementary schools were significantly higher than those of middle and high schools (p < 0.01). For the HCHO, the multi-use practice rooms showed an average 1.5 times higher than general classrooms. In schools located in urban areas, the concentrations of CO, $O_3$, $PM_{10}$, HCHO and TBC were lower than in the vicinity of industrial complexes. The exceeding rate of the school air quality maintenance limits in the 6 air pollutants by law were 6.7%, 3.5%, 1.7%, 18.2%, 13.0% and 18.4% for $CO_2$, $NO_2$, $O_3$, $PM_{10}$, HCHO and TBC, respectively. Based on these results $PM_{10}$ and TBC have to be in the order of priority of need to improve the classroom air quality in elementary school of Ulsan.

Mistakes Made, Lessons Learned: The Eulsukdo Wetland Restoration Program

  • Lineman, Maurice J.M.;Do, Yuno;Kim, Ji-Yoon;Joo, Gea-Jae
    • Journal of Environmental Science International
    • /
    • v.23 no.8
    • /
    • pp.1523-1536
    • /
    • 2014
  • Restoration is the process of reducing or reversing damage to an ecosystem so that it can function in its original manner. However, many restoration programs do not achieve this. In the Nakdong Estuary, the largest migratory nesting site in the center of the East Asian-Australasian flyway, an estuarine barrage was constructed in the 1980s that required site restoration following its completion in 1987 and the expansion of several large industrial complexes(Noksan and Jangrim) and a residential development(Myeongji). The goal of the restoration was to restore the function of the wetland to its pre-disturbance state. To achieve this, a restoration program was designed consisting of three stages. The first stage(1993-1995), saw the construction of three artificial wetlands(Shinhori, Daemadeung, and Eulsuk), the second(2003-2005) involved the dredging and returning of farmed lands to their natural state, and the third(2008-2012) focused on the rehabilitation and vegetation development of the wetlands. However, the project has not achieved all of the desired goals, and it is an example of the lapses in ecological restoration following anthropogenic disturbance. Issues that resulted in an incomplete restoration included the timing of the stages, noncompliance with the restoration plan, not directly monitoring the restoration or continuing the monitoring following completion of the development project, and the political subversion of the restoration plan. For the success of the restoration plan, it is necessary to avoid mistakes such as inconsistent monitoring, unequal levels of stakeholder involvement, and political interference.

Design Standard of Activated Carbon Vessel for the Intermittent Emission Sources of Volatile Organic Compounds (휘발성 유기화합물의 간헐적 배출원에 대한 활성탄 흡착 시스템 설계기준)

  • Lee, Si-Hyun;Lim, Jeong-Whan;Rhim, Young-Jun;Kim, Sang-Do;Woo, Kwang-Je;Son, Mi-Sook;Park, Hee-Jae;Seo, Man-Cheol;Ryu, Seung-Kon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.2
    • /
    • pp.250-260
    • /
    • 2007
  • It was investigated that the emission characteristics of volatile organic compounds (VOCs) from small and medium companies located on industrial complexes in Metropolitan area. The emission characteristics are intermittent sources in which VOCs emissions are highly depends on the working condition. Optimized ventilation system to improve air quality in working area for the three typical companies were installed. Adsorption characteristics of major VOCs such as MEK, IPA, and toluene emitted front the companies were investigated for design of the activated carbon vessel as a VOCs control facility in each company. Concentration of total hydrocarbon and gas amounts needed to ventilation were also used as a design parameter. Mixed adsorbent to improve adsorption characteristics of problematic solvents like IPA and the design guideline of the activated carbon vessel have been suggested.

Problems of Working Hours and Shift Work Systems, and Propsed Methods for Their Improvement (근로시간 및 교대근무편성의 문제점과 개선방향)

  • Seo, Yu-Jin;;Park, Yeong-Man;Mun, Se-Geun
    • Journal of the Ergonomics Society of Korea
    • /
    • v.22 no.3
    • /
    • pp.13-26
    • /
    • 2003
  • The purpose of this study is to investigate the present conditions of the night work and shift work systems in the heavy chemical industrial complexes found in Changwon, Masan, and Chinhae. Korea. We will attempt to define and classify their problems; and to discover further ways to improve their systems. Fifty production factories were carefully selected as the subjects for this study. The shift systems were classified into five categories. The consecutive night shifts were long in almost all cases with 6 days (36 factories) and 7 days (13 factories). It was found that the night work of about] 2 hours continues for a long period in the weekly rotation full-day shift systems and the night-including non-full-day shift systems, and there was no holiday during a shift cycle in the continuous full-day shift systems. The work time in most shift systems was longer than the 44-hours/week permitted by Korean law. Considering the characteristics of these various types of shift systems, the most essential thing to reduce the shift workers' work load may be to shorten their working hours and improve the schedule of shift systems. It is highly recommended as a fundamental solution. to reduce the portal-to-portal hours from 12 to 8 in the night-including non-full-day shift systems and the weekly rotation full-day shift systems, and at least to employ a 4-team 3-shift system in the continuous full-day shift systems. In addition to this, it should from now on be taken as a goal to restructure the types of shift systems by taking such measures as avoiding continuous night work if possible, providing sufficient off-duty intervals both before and after night shift, providing increased opportunities for workers to nap during night work. and increasing the number of holidays.

Concentration and Distribution Characteristics of PM10 in High Schools in the Ulsan Metropolitan Area

  • Jung, Jong-Hyeon;Shon, Byung-Hyun;Phee, Young-Gyu
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.1
    • /
    • pp.42-50
    • /
    • 2012
  • The purpose of this study was to investigate the concentration and distribution characteristics of $PM_{10}$ at high schools classrooms in Ulsan and its surroundings. This study evaluated $PM_{10}$ levels in classrooms at 79 high schools in Ulsan from May 2008 to May 2009. The average $PM_{10}$ level was 63.8 ${\mu}g/m^3$, and the rate of exceeding the statutory maintenance limit was 16.0%. The average $PM_{10}$ level was higher in general schools (64.9 ${\mu}g/m^3$) compared to professional schools (59.2 ${\mu}g/m^3$), and private schools (66.6 ${\mu}g/m^3$) was higher than that of public schools (62.5 ${\mu}g/m^3$). The average $PM_{10}$ level (68.4 ${\mu}g/m^3$) in general classrooms was significantly (p < 0.01) higher than that in multi-purpose ones (54.6 ${\mu}g/m^3$), and first-year student classrooms (73.3 ${\mu}g/m^3$) was significantly (p < 0.05) higher than that in second or third grade ones (67.6 ${\mu}g/m^3$, 51.5 ${\mu}g/m^3$, respectively). The $PM_{10}$ level in schools in Dong-Gu in the vicinity of assorted industrial complexes was higher than that of schools located in other districts around the Ulsan Metropolitan Area. The regression model showed that $PM_{10}$ level was positively associated with number of students and relative humidity.

Urinary Creatinine Concentration in the Korean Population in KNHANES IV, 2009 (한국인의 요중 크레아티닌 농도에 관한 연구 -국민건강영양조사 4기 자료 이용-)

  • Jung, Kyung-Sick;Kim, Nam-Soo;Lee, Byung-Kook
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.1
    • /
    • pp.31-41
    • /
    • 2012
  • Objectives: Biomonitoring is used to assess human environmental exposures. Urinary biomonitoring data are typically adjusted to a constant creatinine concentration to correct for variable dilutions among spot samples. Our objective was to investigate urinary creatinine concentrations by region, gender, age and lifestyle. Methods: We studied urinary creatinine concentrations in 6,286 Koreans aged 20 years old and older who participated the fourth Korea National Health and Nutrition Survey (KNHANES IV) in 2009. Urinary creatinine concentration analysis used the Jaffe method. Results: The average urinary creatinine concentration of 6,286 Koreans was 158.99 mg/dl. The urinary creatinine concentration was significantly higher among men (184.97 mg/dl) than women (130.02 mg/dl). In both men and women, urinary creatinine concentrations were significantly different according to age group (p < 0.01). Whereas the urinary creatinine concentration of men significantly differed with smoking in adjusted comparison analysis, that of women significantly differed by education level. Ninety-two percent of urinary creatinine concentration was included within WHO guidelines effective range(30 mg/dl ${\leq}$ urinary creatinine concentration ${\leq}$ 300 mg/dl). In multiple regression analysis, creatinine was influenced by gender, age and body mass index (BMI). Conclusions: The urinary creatinine value obtained from representative samples of adult Koreans aged 20 year and older in KNHANES IV 2009 could be used as a reference value for other nationally studied surveys, such as abandoned metal mine surveys and surveys for industrial complexes.

Health Vulnerability Assessment for PM10 due to Climate Change in Incheon (인천지역 기후변화에 따른 미세먼지의 건강 취약성 평가)

  • Yoo, Heejong;Kim, Jongkon;Shin, Jaewon;Kim, Youngju;Min, Sungeun;Jegal, Daesung;Bang, Kiin;Lee, Sungmo
    • Journal of Environmental Health Sciences
    • /
    • v.43 no.3
    • /
    • pp.240-246
    • /
    • 2017
  • Objectives: This study was conducted to evaluate the vulnerability of the human health sector to $PM_{10}$ due to climate change in Incheon over the period of 2005-2014. Methods: Vulnerability to $PM_{10}$ consists of the three categories of climate exposure, sensitivity, and adaptive capacity. The indexes for climate exposure and sensitivity indicate positive effects, while adaptive capacity shows a negative effect on vulnerability to $PM_{10}$. The variables in each category were standardized by the rescaling method, and respective relative regional vulnerability was analyzed through the vulnerability index calculation formula of the Intergovernmental Panel on Climate Change. Results: Regions with a high exposure index were the western and northern urban areas with industrial complexes adjacent to a highway, including Bupyong-gu and Seo-gu. Major factors determining the climate exposure index were the $PM_{10}$ concentration, days of $PM_{10}$ >= $100{\mu}g/m^3$, and $PM_{10}$ emissions. The regions showing a high sensitivity index were urban regions with high populations; these commonly had a high mortality rate for related diseases and vulnerable populations. Conclusions: This study is able to support regionally adjusted adaptation policies and the quantitative background of policy priority since it provides information on the regional health vulnerability to $PM_{10}$ due to climate change in Incheon.

A Web-based Real-time Odor Monitoring and Device Management System (웹기반 실시간 악취 모니터링 및 장치 관리 시스템)

  • Shen, Meiling;Kim, Sang-Chul
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.9 no.6
    • /
    • pp.101-109
    • /
    • 2009
  • The people around industrial complexes and polluted areas suffer from the many occurrences of odors, and frequently issue a request for solving the odors to their local government in charge of those areas. Recently local governments whose regions have a number of such areas have a great interest in monitoring odor occurrences and gathering air on demand. This paper proposes a system in which a user can perform real-time monitoring the values of odor and atmospheric sensors, and the management of odor sensing devices using the Internet browser. Compared to previous systems, the system has an advantage of providing the functions for controlling and managing a number of devices irregardless of the location of the user. Also, the system is built around a blackboard-based multi-process architecture, enabling the easy incorporation of a new software model to be found useful. To our experiment, users showed great satisfactions in terms of the easiness of use. Our system has been installed and operated in an area of a local government in which odors are likely to occur.

  • PDF

Distribution of Relative Evapotranspiration Availability using Satellite Data in Daegu Metropolitan (위성 자료를 이용한 대구광역시의 상대적 증발산 효율 분포)

  • Kim, Hae-Dong;Im, Jin-Wook;Lee, Soon-Hwan
    • Journal of the Korean earth science society
    • /
    • v.27 no.6
    • /
    • pp.677-686
    • /
    • 2006
  • Surface evapotranspiration is one of the most important factors to determine the surface energy budget, and its estimation is strongly related with the accuracy of weather forecasting. Surface evapotranspiration over Daegu Metropolitan was estimated using high resolution LANDSAT TM data. The estimation of surface evapotranspiration is based on the relationship between surface radiative temperature and vegetation index provided by a TM sensor. The distribution of NDVI (Normalized Difference of Vegetation Index) corresponds well with that of land-used in Deagu Metropolitan. The temperature of several part of downtown in Deagu metropolitan is lower in comparison with the averaged radiative temperature. This is caused by the high evapotranspiration from dense vegetation like DooRyu Park in Deagu Metropolitan. But, weak evapotranspiration availability is distinguished over the central part of downtown and the difference of evapotranspiration availability on industrial complexes and residential area is also clear.