• Title/Summary/Keyword: Industrial Technology Leak

Search Result 49, Processing Time 0.024 seconds

Design of LNG fuel tank for a light duty truck and numerical analysis of heat leak to LNG tank

  • Alena, Minkasheva;Kim, Sung Joon
    • Journal of Industrial Technology
    • /
    • v.27 no.B
    • /
    • pp.65-70
    • /
    • 2007
  • The LNG tank are properly designed to fit with the limited installation space of a light duty truck, Hyundai Porter II. This designed LNG tank has 36 liter capacity, so two LNG tanks installed on Porter II truck allow it to run about 432 km per fueling. It is almost two times greater than CNG mileage for same truck. To analyze the relationship between car acceleration and heat leak for different fuel vapor/liquid ratios, the modified Fortran program "Pro-Heatleak" is used. Computational analysis shows that the relationship between the heat leak and vapor/liquid ratio is linearly inversed. Heat leak increases with increasing of car acceleration when fuel vapor/liquid ratio is less than 0.5 and decreases when fuel vapor/liquid ratio is greater than 0.5. The difference between maximum and minimum heat leak for full tank is about 12 percents. For the fuel vapor/liquid ratio equal to 0.5 heat leak does not depend on car acceleration.

  • PDF

Analysis of heat leak with the car acceleration for LNG tank of Natural Gas Vehicle (천연가스자동차용 LNG용기에서의 차량가속도와 Heat leak 관계 해석)

  • Minkasheva, Alena;Yu, Young-Min;Park, Yong-Kook;Kim, Sung-Joon
    • Journal of Industrial Technology
    • /
    • v.26 no.B
    • /
    • pp.11-20
    • /
    • 2006
  • LNG is a valuable fuel since it offers some environmental, energy security and economic benefits over diesel. It could be used mainly in heavy-duty trucks and buses. Car acceleration induces the slope angle of the liquid fuel in the tank. Slope angle changes the surface area wetted by liquid fuel and consequently heat leak to the tank. This research is a result of numerical simulation of the heat leak with the car acceleration to LNG tank. The "Pro-HeatLeak" Fortran program is developed and the verification test of the developed program is done. The difference between numerical results and calculated results from MathCad verification test is less than 0.07 percent. The smallest heat leak is correspond to the case without oscillation. For the high car acceleration the value of heat leak is greater than that for the small acceleration. The difference between maximum and minimum heat leak for 10 gallons of fuel vapor in the tank is about 10 percent.

  • PDF

A Study on The Leak of Core Business Technologies Using Preventative Security Methods Such as Clustering (군집화를 이용한 기업 핵심기술 유출자 분류에 관한 연구)

  • Huh, Seung-Pyo;Lee, Dae-Sung;Kim, Kui-Nam
    • Convergence Security Journal
    • /
    • v.10 no.3
    • /
    • pp.23-28
    • /
    • 2010
  • Recently, the leak of domestic core technology of major business in Korea and the subsequent damage, has been increasing every year. Financial losses due to this leak are estimated to be about 220 trillion, which is equivalent to the gross budget of Korea Besides, the majority of the leaks are caused by former and current staff members, cooperated businesses, scientists and invesment companies. This shows that the source of the leaks are internal personnel. In this manner, we can infer that the management and plan of personnel security has not implemented sound practices to prevent technology leak by people. Therefore, this thesis suggests classifying methods of technology leak through clustering, one of the data mining methods about the information of internal personnel to prevent core technology leak from businesses.

Industrial Technology Leak Detection System on the Dark Web (다크웹 환경에서 산업기술 유출 탐지 시스템)

  • Young Jae, Kong;Hang Bae, Chang
    • Smart Media Journal
    • /
    • v.11 no.10
    • /
    • pp.46-53
    • /
    • 2022
  • Today, due to the 4th industrial revolution and extensive R&D funding, domestic companies have begun to possess world-class industrial technologies and have grown into important assets. The national government has designated it as a "national core technology" in order to protect companies' critical industrial technologies. Particularly, technology leaks in the shipbuilding, display, and semiconductor industries can result in a significant loss of competitiveness not only at the company level but also at the national level. Every year, there are more insider leaks, ransomware attacks, and attempts to steal industrial technology through industrial spy. The stolen industrial technology is then traded covertly on the dark web. In this paper, we propose a system for detecting industrial technology leaks in the dark web environment. The proposed model first builds a database through dark web crawling using information collected from the OSINT environment. Afterwards, keywords for industrial technology leakage are extracted using the KeyBERT model, and signs of industrial technology leakage in the dark web environment are proposed as quantitative figures. Finally, based on the identified industrial technology leakage sites in the dark web environment, the possibility of secondary leakage is detected through the PageRank algorithm. The proposed method accepted for the collection of 27,317 unique dark web domains and the extraction of 15,028 nuclear energy-related keywords from 100 nuclear power patents. 12 dark web sites identified as a result of detecting secondary leaks based on the highest nuclear leak dark web sites.

A Study on Development of Internal Information Leak Symptom Detection Model by Using Internal Information Leak Scenario & Data Analytics (내부정보 유출 시나리오와 Data Analytics 기법을 활용한 내부정보 유출징후 탐지 모형 개발에 관한 연구)

  • Park, Hyun-Chul;Park, Jin-Sang;Kim, Jungduk
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.30 no.5
    • /
    • pp.957-966
    • /
    • 2020
  • According to the recent statistics of the National Industrial Security Center, about 80% of the confidential leak are caused by former and current employees in the case of domestic confidential leak accidents. Most of the information leak incidents by these insiders are due to poor security management system and information leak detection technology. Blocking confidential leak of insiders is a very important issue in the corporate security sector, but many previous researches have focused on responding to intrusions by external threats rather than by insider threats. Therefore, in this research, we design an internal information leak scenario to effectively and efficiently detect various abnormalities occurring in the enterprise, analyze the key indicators of the leak symptoms derived from the scenarios by using data analytics and propose a model that accurately detects leak activities.

Hermetic Characteristics of Negative PR (Negative PR의 기밀 특성)

  • Choi, Eui-Jung;Sun, Yong-Bin
    • Journal of the Semiconductor & Display Technology
    • /
    • v.5 no.2 s.15
    • /
    • pp.33-36
    • /
    • 2006
  • Many issues arose to use the Pb-free solder as adhesive materials in MEMS ICs and packaging. Then this study for easy and simple sealing method using adhesive materials was carried out to maintain hermetic characteristic in MEMS Package. In this study, Hermetic characteristic using negative PR (XP SU-8 3050 NO-2) as adhesive at the interface of Si test coupon/glass substrate and Si test coupon/LTCC substrate was examined. For experiment, the dispenser pressure was 4 MPa and the $200\;{\mu}m{\Phi}$ syringe nozzle was used. 3.0 mm/sec as speed of dispensing and 0.13 mm as the gap between Si test coupon and nozzle was selected to machine condition. 1 min at $65^{\circ}C$ and 15 min at $95^{\circ}C$ as Soft bake, $200\;mj/cm^2$ expose in 365 nm wavelength as UV expose, 1 min at $65^{\circ}C$ and 6 min at $95^{\circ}C$ as Post expose bake, 60 min at $150^{\circ}C$ as hard bake were selected to activation condition of negative PR. Hermetic sealing was achieved at the Si test coupon/ glass substrate and Si test coupon/LTCC substrate. The leak rate of Si test coupon/glass substrate was $5.9{\times}10^{-8}mbar-l/sec$, and there was no effect by adhesive method. The leak rate of Si test coupon/LTCC substrate was $4.9{\times}10^{-8}mbar-l/sec$, and there was no effect by dispensing cycle. Better leak rate value could be achieved to use modified substrate which prevent PR flow, to increase UV expose energy and to use system that controls gap automatically with vision.

  • PDF

Reopening Phenomena of the 2.25Cr-1Mo Steel Specimen by Self-wastage (Self-wastage에 의한 2.25Cr-1Mo Steel 시편의 Re-open 현상)

  • Jeong, Kyung-chai;Kwon, Sang-woon;Choi, Jong-hyeun;Park, Jin-ho;Hwang, Sung-tai
    • Applied Chemistry for Engineering
    • /
    • v.10 no.4
    • /
    • pp.531-536
    • /
    • 1999
  • Experiments on micro-leak of water were carried out with the water injecting simulator in liquid sodium atmosphere. The leak path was plugged by the sodium-water reaction products in the 2.25Cr-1Mo steel specimen. However, leak paths re-opened in most cases. The self-wastage patterns were not affected by the sodium temperature in the re-opened specimen. The diameter of the defected area, including the re-opened part, was about 5 min. It took 143, 40.7 and 34.7 minutes to re-open the leak path at 450, 475, and $510^{\circ}C$, respectively. It was concluded that the reopening time decreased with the increasing temperature.

  • PDF

Acoustic Emission (AE) Technology-based Leak Detection System Using Macro-fiber Composite (MFC) Sensor (Macro fiber composite (MFC) 센서를 이용한 음향방출 기술 기반 배관 누수 감지 시스템)

  • Jaehyun Park;Si-Maek Lee;Beom-Joo Lee;Seon Ju Kim;Hyeong-Min Yoo
    • Composites Research
    • /
    • v.36 no.6
    • /
    • pp.429-434
    • /
    • 2023
  • In this study, aimed at improving the existing acoustic emission sensor for real time monitoring, a macro-fiber composite (MFC) transducer was employed as the acoustic emission sensor in the gas leak detection system. Prior to implementation, structural analysis was conducted to optimize the MFC's design. Consequently, the flexibility of the MFC facilitated excellent adherence to curved pipes, enabling the reception of acoustic emission (AE) signals without complications. Analysis of AE signals revealed substantial variations in parameter values for both high-pressure and low-pressure leaks. Notably, in the parameters of the Fast Fourier Transform (FFT) graph, the change amounted to 120% to 626% for high-pressure leaks compared to the case without leaks, and approximately 9% to 22% for low-pressure leaks. Furthermore, depending on the distance from the leak site, the magnitude of change in parameters tended to decrease as the distance increased. As the results, in the future, not only will it be possible to detect a leak by detecting the amount of parameter change in the future, but it will also be possible to identify the location of the leak from the amount of change.

A Study on the Reliability Improvement of Compartment Leak Test in Surface Vessels (함정 격실기밀 평가 방안에 대한 신뢰성 향상 연구)

  • Choi, Sang-Min;Park, Dong-Kyu;Beak, Yong-Kawn
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.4
    • /
    • pp.546-551
    • /
    • 2020
  • Generally, surface vessels have many compartments for operation and living quarters, and each compartment is an important space for the ship's survivability. During ship construction, a compartment leak test is necessary and is carried out on each vessel. However, the current test method is in doubt when looking at the actual test results. The reason is that only one pressure gauge is used for the measurement to check the air, so an uncomprehended phenomenon is detected during group compartment leak tests. From this point of view, an improved test device and method are needed. In this study, a multi-channel data acquisition device with multiple pressure sensors is proposed to detect each compartment's pressure variation or pressure drop. This test is a more confidential compartment leak test than the current method, and the test device can show real-time pressure detection values of each of the pressure sensors, which are installed in each compartment, including unmanned space.

Development of Gas Leak Detecting System Based on Quantum Technology (양자기술기반 가스 누출 감지 시스템 개발)

  • Kwon, Oh Sung;Park, Min Young;Ban, Changwoo
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.5
    • /
    • pp.57-62
    • /
    • 2021
  • Gas is an energy source widely used in general households and industrial sites, and is also a process material widely used in petrochemical and semiconductor processes. However, while it is easy to use, it can cause large-scale human damage due to leakage, explosion, and human inhalation. Therefore, a gas facility safety management solution that can be safely used at home and industrial sites is essential. In particular, the need to develop advanced gas safety solutions is emerging as gas facilities are aging. In this paper, a technology was developed to measure the presence and concentration of gas leaks from a distance by irradiating photons, the minimum energy unit that can no longer be divided into gas facilities, and analyzing the number of reflected photons. This overcomes technical limitations such as short detection distance and inability to detect fine leaks, which are the limitations of conventional electric/chemical gas sensors or infrared-based gas leak detectors.