• Title/Summary/Keyword: Industrial Safety and Health Act

Search Result 191, Processing Time 0.028 seconds

Advertising Regulations for Juvenile Protection: Problems and Alternatives (청소년 보호를 위한 광고 규제: 문제점과 개선 방안)

  • Cho, Jae-Yung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.2
    • /
    • pp.672-677
    • /
    • 2014
  • The purpose of this study is to analyze the advertising regulations for juvenile protection, find their problems and suggest the alternatives for their improvements. All media products harmful to juveniles including advertising are regulated by the Juvenile Protection Act. The regulations related with advertising for juvenile protection of the Special Act on Safety Control of Children's Dietary Life, the Broadcasting Advertising Review Regulations and the National Health Improvement Act were analyzed. The results were: 1)the weaknesses of the implementation of the regulations with lack a little consistency and a lack of objectivity; 2)the necessity of the newly established articles with the times; and 3) the urgency of the establishment of alcohol advertising regulations. In conclusion, it has been suggested that the integrated advertising regulations or guidelines by the unitary review board should be implemented.

Health Hazardous Substances in Construction Work in Korea (건설업 근로자의 유해 작업 환경 노출 실태에 관한 연구)

  • Choi, Jae-Wook;Mun, Jung-Soo;Kim, Jeong-Ah;Won, Jeong-Il;Park, Hee-Chan
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.10 no.1
    • /
    • pp.74-92
    • /
    • 2000
  • This study was performed to evaluate the working conditions In construction workers through measurements of working environments and to improve the working conditions and to design the appropriate environmental and health management system. The results of measurement for working environments in construction work are as following: 1. The excess rate of noise and dust concentration in express highway construction, road construction, building construction and interior painting was 28.6% and 24.5% respectively. 2. The excess rate of mixed organic solvents concentration in interior painting was 39.3%. 3. The chain type bulldozer has the highest level of vibration; the excess rate was 85.7%, and among the vibration instruments, the level of left hand's vibration of all vibrators exceeded the criterion and in the case of drilling all the level of vibration exceeded the criterion in both hands. On the basis of the results in this research the environmental and health management system for construction workers must be considered. Therefore, it is necessary to be introduced the special medical examination and measurement of working environments in construction industry. In defining "the working place" of Article 39 of Enforcement regulations of industrial safety and health act, the word "indoors" should be deleted. Then the eligible industry for measurement of working environment must be extended. And it is also necessary for construction industry to be performed group health management service by agencies such as other manufacturing industry.

  • PDF

Review Paper for Characterization of Photoionization Detector-Direct Reading Monitors (산업현장에 활용되는 PID 직독식장비의 특성 고찰)

  • Sungho Kim;Hae Dong Park;Eunsong Hwang
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.2
    • /
    • pp.93-102
    • /
    • 2023
  • Objectives: With the evolution of direct reading sensors, it is possible to monitor several substances through telecommunication. However, there are some limitations on the use of direct reading technologies in the Occupational Safety and Health Act in South Korea, which only applies to detector tubes, noise, heat, and carbon monoxides. The number of chemicals and their amount of use have been continuously increasing in South Korea. The Ministry of Employment and Labor (MoEL) has concerns about worker's health because exposure is only covered for about 1.2% of all distributed chemicals. Using a direct reading monitor with photoionization detectors (PID-DRMs), gases and vapors chemicals can be measured. Based on the data, business owners are able to create corrective strategies, provide better working routines, and select correct respiratory equipment. PID-DRMs are less expensive and easier to handle for an owner voluntarily controlling chemicals emitted in the workplace. However, there are several limitations on using these PID-DRMs to the degree that the MoEL has not been able to select a legal monitor. The aim of this study was to review previous studies related to PID-DRMs and identify the characterization and limitation on PID-DRMs. Methods: To search for related studies on PID-DRMs, key words were used including direct reading monitors/instruments and/or photoionization detectors. Through that, four domestic and 15 international studies were reviewed. Results: Studies on PID-DRMs were conducted by chamber (enclosed, dynamic, walk-in) and in the field (experimental environment, actual environment). The concentration of PID-DRMs and charcoal tubes were compared for a single substance or mixture, or within the PID-DRMs. There was a high correlation between the two concentrations, but it did not meet the accuracy criteria (95% confidence interval, within 25%) of the NIOSH technical report (2012). In addition, differences in measured values occurred according to environmental factors (temperature, humidity) and high concentration, and concentration values tended to be underestimated due to contamination of the sensor. As a way to improve the accuracy of PID concentration, it was proposed to use correction factors, charcoal tube-based correction factors, or to calibrate the PID-DRMs in the same environment as the workplace. Conclusions: PID-DRMs can likely be used by business owners for the purpose of voluntarily managing the workplace environment, and it is expected that it will be possible to use them as legal equipment if a PID sensor can be upgraded and the limitations of the sensor (temperature, humidity, high concentration evaluation, sensor pollution) can be overcome in the near future.

A Study on the Safety of Carbon Manufacturing By-product Gas Emissions (카본제조 부생가스 배출 안전성에 관한 연구)

  • Joo, Jong-Yul;Jeong Phil-Hoon;Kim, Sang-Gil;Sung-Eun, Lee
    • Journal of the Korea Safety Management & Science
    • /
    • v.26 no.1
    • /
    • pp.99-106
    • /
    • 2024
  • In the event of an emergency such as facility shutdown during process operation, the by-product gas must be urgently discharged to the vent stack to prevent leakage, fire, and explosion. At this time, the explosion drop value of the released by-product gas is calculated using ISO 10156 formula, which is 27.7 vol%. Therefore, it does not correspond to flammable gas because it is less than 13% of the explosion drop value, which is the standard for flammable gas defined by the Occupational Safety and Health Act, and since the explosion drop value is high, it can be seen that the risk of fire explosion is low even if it is discharged urgently with the vent stock. As a result of calculating the range of explosion hazard sites for hydrogen gas discharged to the Bent Stack according to KS C IEC 60079-10-1, 23 meters were calculated. Since hydrogen is lighter than air, electromechanical devices should not be installed within 23 meters of the upper portion of the Bent Stack, and if it is not possible, an explosion-proof electromechanical device suitable for type 1 of dangerous place should be installed. In addition, the height of the stack should be at least 5 meters so that the diffusion of by-product gas is facilitated in case of emergency discharge, and it should be installed so that there are no obstacles around it.

Measurement of Heavy Metals Using Portable XRF in Children's Playing Goods (Portable XRF를 이용한 어린이 야외 놀이용품의 중금속 측정)

  • Kim, Hyung-Jin;Baek, Young Man;Jung, Kyung Hoon;Hong, Suk Youn;Heo, Hwa Jin;Seong, Jin Uk;Park, Je Chul
    • Journal of Environmental Science International
    • /
    • v.22 no.4
    • /
    • pp.471-479
    • /
    • 2013
  • The present study was conducted to judge the applicability of field quality control by children's goods manufacturers by assessing the contents of heavy metals such as Pb and Cd in outdoor play goods for children through measurement using Portable XRF and comparing the results through detailed analyses using ICP. Heavy metal contents of 711 part samples of 505 products were measured using XRF. According to the results, the ratio of products that exceeded the Pb and Cd content standards specified under the Quality Management and Safety Control of Industrial Products Act were 2.4% and 2.6%. Many products certified for self-regulated safety exceeded the standards and thus it was considered that harmful chemical material centered safety management systems would be necessary. Detailed ICP analyses of some products were compared and the results showed deviations of 0.9~80.8% from XRF results. The reasons for this are deviations in the characteristics of measured cross sections and the homogeneity of samples resulting from sample preparation methods, etc. Therefore, it is considered that field quality control will be applicable if measuring methods are efficiently established based on product characteristics and calibration curve preparation methods are established through quality control.

Literature review of the Reduction of Hydrogen Sulfide and Ammonia in Livestock Pen: Comparison between Korean and Chinese cases (축사 내 황화수소와 암모니아의 저감방안 고찰: 한중비교)

  • Yan, Ding;Moon, Chan-Seok
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.29 no.4
    • /
    • pp.442-451
    • /
    • 2019
  • Objectives: The aim of this study was to review the reduction methods for ammonia (NH3) and hydrogen sulfide (H2S) exposure in livestock. Methods: By reviewing domestic and international research reports from Korea and China, reducing ammonia and hydrogen sulfide in livestock pens was analyzed in terms of ventilation, deodorant, and feed additives. In addition, exposure limits in Korea and China were examined through a comparison between 'TLV-TWA and STEL under the Industrial Safety and Health Act in Korea' and 'Management Standards for Air of Livestock Pens in China'. Results and Discussion: In order to effectively control hazardous gases and odors in livestock pens, the enhancement of natural ventilation or the addition of ventilation fans at the pollution source are being examined. Deodorants are used as adsorbents or masking deodorants. Additives to feed were zeolite powder, FeSO4·7H2O, enzymes, and microbial preparations. Use of feed additives was low-cost and had significant effects compared to other methods. Zeolite was the most commonly used in feed additive in Chinese cases and proved to be low-cost and effective for reducing harmful gases. Enzyme preparations were shown to stimulate the growth of livestock, but were expensive. Conclusions: This study reviewed and examined domestic and international research papers in Korea and China for reducing ammonia and hydrogen sulfide concentrations in livestock pens. More diverse research and the development of feed additives are needed.

Additional Improvement and Evaluation of Exhaust Ventilation Systems at Small and Medium Sized Enterprise (중.소규모 사업장의 국소배기장치 설치 실태와 문제점 및 개선방안)

  • Lim, Seong-Keun;Park, Doo-Yong;Kim, Won-Ki;Kim, Soo-Geun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.20 no.1
    • /
    • pp.1-9
    • /
    • 2010
  • Objectives : The purposes of this study were to evaluate exhaust ventilation systems(EVSs) and to suggest problems and improvements. Methods : For 50 small and medium-sized enterprises, we carried out evaluation of EVSs. We evaluated hoods with smoke tester and measurement of capture velocity. In addition, we used several indicators for performance evaluation designed in this study. Results : 1. Based on the smoke flow pattern and the criteria of occupational health and safety act, 67.8% of hoods were rated 'good' level at smoke test whereas 26.3% were rated 'good' level at measurement of capture velocity. 2. 29.3% of hoods, of which ratio of measured actual air flow at hood(Qah) to required ideal exhaust air flow at hood(Qih) was 1 or more, were rated 'good' level. 3. The % of EVS, of which ratio of measured actual air flow at stack(Qast) to total required ideal exhaust air flow at hood(Qith) was 1 or more, was 29.0%. 4. For the ratio of measured Qast to existing air flow at fan(Qfan), only 5% of EVSs were 1 or more and 26.0% were 0.8 or more but less than 1.0. 5. For the ratio of measured Qast to total measured actual exhaust air flow at hood(Qath), 74.0% were 0.8 or more but less than 1.0. 6. The percentage of EVS, of which ratio of total measured Qath to existing Qfan was 0.8 or more, was 19.0%. 7. The percentage of EVS, of which ratio of total measured Qath to total required ideal exhaust Qith was 1 or more, was 26.0%. 8. For the comprehensive evaluation indicators designed in this study, 29.0% were 0.8 or more. Conclusions : We found that few exhaust local ventilations at small and medium-sized enterprises were rated 'good' level and that most exhaust local ventilations had 'poor' design and installation. Therefore, relevant professional manpower and enterprises have to construct exhaust local ventilation where it is needed, and technical guidance and economic support are needed to improve 'poor' exhaust local ventilation after self-evaluation.

A Study on the Improvement Plan of Toxic Substance Designation Criterion Based on GHS Hazards (GHS 유해성을 기반으로 한 유독물질 지정체계 개선방안 연구)

  • Kim, Hyo-dong;Park, Kyo-shik
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.32 no.3
    • /
    • pp.209-220
    • /
    • 2022
  • Objectives: This study was performed to suggest how to re-establish criterion for toxic substances under the Chemical Control Act (CCA) in South Korea by comparing the GHS (Globally Harmonized System of Classification and Labeling of Chemicals) score and toxic properties. Methods: Toxic substances were classified into seven groups (Acute toxicity (1A), Chronic toxicity (2C), Environmental hazards (3E), Acute toxicity & chronic toxicity (4AC), Chronic toxicity & environmental hazards (5CE), Acute toxicity & environmental hazards (6AE), and Acute toxicity & chronic toxicity & environmental hazards (7ACE)) according to their toxic properties. The GHS score was calculated to sum up five toxicity indicators (health acute toxicity, health repeated toxicity, carcinogenicity, health other chronic toxicity and environmental hazards). Results: The GHS score of 7ACE was higher by 7 times that of 1A. 1A is the only group which has lower than the total GHS score. The highest score was 47, for sodium chromate (CAS no. 7775-11-3), which belongs to group 7ACE. This is classified as acute toxicity, carcinogenicity, germ cell mutagenicity, reproductive toxicity, and acute and chronic environmental hazard. On the other hand, the lowest score was 2.75, which was assigned to 177 chemicals belonging to group 1A. When the health acute toxicity indicator was omitted from the toxic criterion, toxic substances could be divided into the sub-groups 'human chronic hazards group' (HCG) and 'environmental hazards group' (EG) according to their GHS score and properties. Conclusions: The proposed criterion for toxic substances is to establish sub-groups defined as HCG and EG for separate control and that the 1A group be moved to substances requiring preparation for accidents under the CCA.

A Study of Sound Insulation and Structure Safety of the Shelter from the Firing of the Large Caliber Gun (포 발사에 따른 쉘터 구조물의 차음 및 구조안전성 연구)

  • Lee, HaeSuk;Heo, DongEun;Park, NoSeok;Na, TaeHeum;Jang, YoHan;Hong, JunHee
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.639-646
    • /
    • 2017
  • This paper describes the sound insulation and structural safety of the shelter which may be used for shooters. The noise level of the shelter should be less than 100 dB on the basis of the Industrial Safety and Act, the World Health Organization and the MIL-STD. The sound insulation design was designed for the shelter structure. The designed shelter performance was verified by the real measurement after completing the construction of the shelter. The system was also designed using the finite element method with data of sound pressure measured in the test. Its response was obtained numerically. It is proved that the shelter structure is sufficiently safe considering the calculated maximum stress level with the allowable stress of structural property.

Review on asbestos analysis (석면 분석방법에 대한 고찰)

  • Ham, Seung hon;Hwang, Sung Ho;Yoon, Chungsik;Park, Donguk
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.19 no.3
    • /
    • pp.213-232
    • /
    • 2009
  • This document was prepared to review and summarize the analytical methods for airborne and bulk asbestos. Basic principles, shortcomings and advantages for asbestos analytical instruments using phase contrast microscopy(PCM), polarized light microscopy(PLM), X-ray diffractometer (XRD), transmission electron microscopy(TEM), scanning electron microscopy(SEM) were reviewed. Both PCM and PLM are principal instrument for airborne and bulk asbestos analysis, respectively. If needed, analytical electron microscopy is employed to confirm asbestos identification. PCM is used originally for workplace airborne asbestos fiber and its application has been expanded to measure airborne fiber. Shortcoming of PCM is that it cannot differentiate true asbestos from non asbestos fiber form and its low resolution limit ($0.2{\sim}0.25{\mu}m$). The measurement of airborne asbestos fiber can be performed by EPA's Asbestos Hazard Emergency Response Act (AHERA) method, World Health Organization (WHO) method, International Standard Organization (ISO) 10312 method, Japan's Environmental Asbestos Monitoring method, and Standard method of Indoor Air Quality of Korea. The measurement of airborne asbestos fiber in workplace can be performed by National Institute for Occupational Safety and Health (NIOSH) 7400 method, NIOSH 7402 method, Occupational Safety and Health Administration (OSHA) ID-160 method, UK's Health and Safety Executive(HSE) Methods for the determination of hazardous substances (MDHS) 39/4 method and Korea Occupational Safety and Health Agency (KOSHA) CODE-A-1-2004 method of Korea. To analyze the bulk asbestos, stereo microscope (SM) and PLM is required by EPA -600/R-93/116 method. Most bulk asbestos can be identified by SM and PLM but one limitation of PLM is that it can not see very thin fiber (i.e., < $0.25{\mu}m$). Bulk asbestos analytical methods, including EPA-600/M4-82-020, EPA-600/R-93/116, OSHA ID-191, Laboratory approval program of New York were reviewed. Also, analytical methods for asbestos in soil, dust, water were briefly discussed. Analytical electron microscope, a transmission electron microscope equipped with selected area electron diffraction (SAED) and energy dispersive X-ray analyser(EDXA), has been known to be better to identify asbestiform than scanning electron microscope(SEM). Though there is no standard SEM procedures, SEM is known to be more suitable to analyze long, thin fiber and more cost-effective. Field emission scanning electron microscope (FE-SEM) imaging protocol was developed to identify asbestos fiber. Although many asbestos analytical methods are available, there is no method that can be applied to all type of samples. In order to detect asbestos with confidence, all advantages and disadvantages of each instrument and method for given sample should be considered.