• 제목/요약/키워드: Industrial Noise

Search Result 1,250, Processing Time 0.033 seconds

Industrial noise : current problems and practical plan (사업장소음분야 : 현황과 문제점 및 실천계획)

  • Chang, Seo-Il;Oh, You-Soon;Chun, Hyung-Joon;Ko, Joon-Hee
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.102-106
    • /
    • 2006
  • Community noise has been serious social issues in Korea. The community noise concerns on traffic, industrial and apartment complex noise. In industrial noise, construction, factory sectors are included. This paper summerizes the final report prepared for MOE in 2005 by authors. The new policy will be enforced beginning in 2006 with 5 year schedule. Details on the policy will be demonstrated at the presentation.

  • PDF

Study on the Reduction of Wet-Brake Noise (습식 브레이크의 소음 저감에 대한 연구)

  • Koo, Ja-Ham;Kwon, Soon-Hong;Chung, Sung-Won;Park, Jong-Min;Choi, Won-Sik;Kim, Jong-Soon;Kwon, Soon-Goo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.14 no.1
    • /
    • pp.57-62
    • /
    • 2015
  • The wet brakes used on a forklift often produce noise upon engagement. The elimination or reduction of this squeal noise is an important task for the improvement of the comfort of those operating these machines. In this paper, a test rig was developed for the testing of brake noise, and the squeal noise was measured with this apparatus. Automatic transmission fluid and grooves in the material of the friction-plate pad were found to be the main factors causing squeal noise. In order to identify the characteristics of this type of noise, signal analyses of the noise were conducted using different frequency spectra. The experimental results showed that the viscosity of the automatic transmission fluid and the groove pattern on the friction-plate pad largely affected the reduction of the wet brake squeal noise made by an industrial forklift.

Characteristics of Industrial Machinery Noise (산업기계류의 소음 특성)

  • Kang, Dae-Joon;Gu, Jin-Hoi;Lee, Jae-Won
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.2
    • /
    • pp.160-165
    • /
    • 2010
  • As the various industrial machinery has come into being by development of industrial technology, the productivity of the basic industrial machinery has improved. However, at the same time, noise from various industrial machinery disturbs the quiet environment. There are 35 kinds of the noise emission machinery defined in the noise and vibration control act according to the horse power and the number of machinery. These were classified in 1992, and the characteristics of the noise emission machinery may be different from the past one. So we need to investigate the characteristics of the noise emitted by machinery to control it rightly. We measured sound intensity of 32 noise emission machinery to calculate the sound power levels of those and investigated the characteristics of the sound power level of those according to the frequency. We found that the forging machine, concrete pipe and pile making machine, sawing machine, etc. are noisy. The generator, the concrete pipe and pile making machine, etc. emit the low frequency noise, but the molding machine, the stone cutter, the metal cutter, etc. emit the high frequency noise.

Efficient Method to Estimate the Number of Exposed People to Industrial Noise Using the GIS and Three Dimensional Noise Mapping - Focusing on the Industrial Noise - (GIS와 3차원 소음지도를 이용한 소음 노출 인구 산정 방법에 관한 연구 - 공장 소음을 중심으로 -)

  • Ko, Joon-Hee;Chun, Hyung-Joon;Chang, Seo-Il
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.6 s.123
    • /
    • pp.491-497
    • /
    • 2007
  • Reasonably accurate estimation of the exposed population to the distinct levels of noise is essential to the efficient management of urban environmental noise. This study proposes a method of calculating the number of exposed people to industrial noise by using GIS tool and noise mapping. The exposed population of noise based on estimation of the number of people that lived in each building in urban area is compared with the one based on density of population. This study suggests the five step method that consists of gathering the fundamental data, extracting the property from the digital map, noise mapping based on the three dimensional topography, estimating population that lives in each building, merging the various results with GIS tool, and estimating exposed population to industrial noise through analyzing the noise map with GIS tools.

A Study on the Noise and Vibration Diagnostic of the Industrial Robot Reducer (산업용 로봇 감속기의 소음 진동 평가에 대한 연구)

  • Kim, Woo-Hyung;Chung, Jin-Tai
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.875-878
    • /
    • 2004
  • The noise and vibration diagnostic of the industrial robot reducer is ultimately the purpose. We evaluated a noise and vibration tendency of the industrial robot reducer to be made in the outside (RV reducer) through the experiment. Also, we compared the RV reducer to the industrial robot reducer (RD reducer) in the domestic. We measured the noise level with the sound level meter and analyzed the vibration tendency with the waterfall plot. Through the comparison of RV reducer and RD reducer diagnose the industrial robot reducer. We guessed the improvement direction of RD reducer. (The domestic's industrial robot reducer).

  • PDF

Efficient method to estimate the number of exposed people to industrial noise using the GIS and three dimensional noise mapping (GIS와 3차원 소음지도를 이용한 소음 폭로인구 산정 방법에 관한 연구)

  • Ko, Joon-Hee;Lee, Ki-Jung;An, Jang-Ho;Chang, Seo-Il
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.438-442
    • /
    • 2006
  • Reasonably accurate estimation of the exposed population to the distinct levels of noise is essential to the efficient management of urban environmental noise. This study proposes a method of calculating the number of exposed people to industrial noise by using GIS tool and noise mapping. The exposed population of noise based on estimation of the number of people that lived in each building in urban area is compared with the one based on density of population. This study suggests the six step method that consists of gathering the fundamental data, extracting the property from the digital map, noise mapping based on the three dimensional topography, estimating population that lives in each building, merging the various results with GIS tool, and estimating exposed population to industrial noise through analyzing the noise map with GIS tools

  • PDF

Analytical Procedures for Designing an Optimal Noise Hazard Prevention Program

  • Asawarungsaengkul, Krisada;Nanthavanij, Suebsak
    • Industrial Engineering and Management Systems
    • /
    • v.4 no.2
    • /
    • pp.165-175
    • /
    • 2005
  • Two extreme and one mixed procedures for designing a noise hazard prevention program are discussed in this paper. The two extreme design procedures (engineering-based and HPD-based) yield upper and lower bounds of the total noise control cost, respectively; while the mixed design procedure provides an optimal noise hazard prevention program within a given total budget. The upper bound of the workforce size for job rotation is approximated using a heuristic procedure. Six optimization models are developed and utilized by the mixed procedure to eliminate or reduce excessive noise levels (or noise exposures) in an industrial workplace. The mixed procedure also follows the OSHA’s hierarchy of noise control. A numerical example is given to demonstrate the application of the proposed design procedures.

The Effect of Knowledge, Attitude and Practice on Noise - induced Hearing Loss (소음에 대한 지식, 태도 및 실천이 청력손실에 미치는 영향)

  • Ham, Wan-Shik;Lee, Kwang-Mook;Whang, Byoung-Moon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.9 no.1
    • /
    • pp.41-55
    • /
    • 1999
  • In order to evaluate the effects of knowledge, attitude and practice on noise-induced hearing loss or hearing threshold level, questionnaire survey was performed and hearing thresholds of 1 kHz and 4 kHz were measured on 1,040 subjects with workers exposed to noise, safety and health officers. industrial hygienists, analysts rind office workers. The results were as follows ; 1. The following 6 factors were obtained by factor analysis and factor rotation of 30 questionnaire of knowledge, attitude and practice about noise; knowledge of noise (F1), concern of hearing protective devices (F2), concern of noise induced hearing loss (F3), concern of noise level and hearing impairment (F4), concern of noise in workplace (F5) and recognition of noised-induced hearing loss (F6). 56.1% of variance was explained by 6 factors. 2. Significant variables influencing knowledge, attitude and practice about noise were education level and age in F1, personal protective devices (PPE) and education level in F2, age and education level in F3, education level, age and sex in F4, PPE, education level, age and work duration in F5, and work duration and PPE in F6. 3. Hearing thresholds of 4 kHz were significantly higher in workers exposed to noise than that of in the other subjects and tended to be higher in industrial hygienists, safety and health officers and analysts than that of the office workers. 4. Significant variables influencing hearing thresholds of 1 kHz were age, education level, F5 and F6 in workers exposed to noise, and F1 in industrial hygienists. 5. Significant variables influencing hearing thresholds of 4 kHz were age, F6, sex, work duration, F1, F5, F2 and F3 in workers exposed to noise, F1 and age in safety and health officers, and F6, sex and F4 in industrial hygienists. With the above results, it suggested that workers exposed to noise be needed the education of knowledge, attitude and practice about noise in hearing conservation program for the prevention of noise induced hearing loss. Also, it suggested that health managers in workplace be needed countermeasures to prevent hearing loss although they are intermittently exposed to noise.

  • PDF

A Follow-up Study on the Personal Noise Exposed Dose and Hearing Loss (개인 소음폭로량과 청력손실에 관한 추적조사)

  • Kim, Won-Sool;Hong, Young-Seoub;Kim, Yang-Seak;Lee, Sang-Ju;Park, Kyung-Il;Jung, Kap-Yull;Kim, Joon-Youn
    • Journal of Preventive Medicine and Public Health
    • /
    • v.27 no.2 s.46
    • /
    • pp.286-298
    • /
    • 1994
  • For the purpose of presenting the basic data for the establishment of control measures on the long-term noise exposed workers, this study was carried out on the relationship between personal noise exposed dose and hearing loss on the 67 male workers whose hearing threshold had exceeded 40 dB in 4,000 Hz, from 1990 to 1992. Conclusively, the level of hearing loss was significantly related to personal noise exposed dose in follow-up period. We considered that personal noise exposed dose which was measured by the personal noise dosemeter was more efficient rather than the noise level of workplace for the evaluating the long-term change of hearing acuity. And although in the case of not-diagnosed as noise induced hearing loss. it was suspected that the active control programs such as improvement of noisy environment or early transfer to proper workplace were needed on the workers who exposed with over 90 dB in personal noise exposed dose.

  • PDF

A analysis of frequency characteristics for the noise cut transformer (노이즈 차폐 변압기의 주파수 특성 분석)

  • Kim, Myoung-Seok;Oh, Joon-Sik;Cho, Hyun-Kil;Han, Gyu-Hwan;Park, Jong-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.957-959
    • /
    • 2005
  • A noise reduction equipment in power systems was device combined in a passive element such as the form of L, R and C. A analysis of frequency characteristics for the transformer models shall be considered the additional capacitance between the windings($C_{ps}$), terminals($C_s$), and winding-ground($C_g$). A noise in transformer is modeled by take account into the different frequency. In case of the high frequency, transformer windings with stray capacitance have lower impedance. Therefore a noise is transferred from primary winding to secondary winding. Noise Cut Transformer(NCT) was the noise reduction device and was normally single phase two-winding type transformer. We analyzed frequency characteristics using the nodal network analysis with the equivalent circuit and the simulation of the MATLAB.

  • PDF