• 제목/요약/키워드: Industrial Environmental Analysis

Search Result 2,420, Processing Time 0.036 seconds

Development and Application of an Energy Input-Output Table for an Energy Demand and Supply Activities Analysis

  • Pruitichaiwiboon, Phirada;Lee, Cheul-Kyu;Baek, Chun-Youl;Lee, Kun-Mo
    • Environmental Engineering Research
    • /
    • v.16 no.1
    • /
    • pp.19-27
    • /
    • 2011
  • This paper introduces an approach to identify the total energy consumption with subsequent $CO_2$ emissions, for both industrial and non-industrial sectors. Statistical data for 2005 were compiled in a national account system to construct an energy input-output table for investigating the influence between energy demand and supply activities. The methodological approach was applied to South Korea. Twelve types of energy and fifteen industrial and non-industrial sectors are formed as the compartments of the input-output table. The results provided quantitative details of the energy consumption and identified the significant contributions from each sector. An impact analysis on the $CO_2$ emissions for the demand side was also conducted for comparison with the supply side.

Modeling of Eco-Industrial Park (EIP) through Material Flow Analysis (MFA) (물질흐름분석을 통한 생태산업단지의 모델링)

  • Lee, Seungjun;Yoo, ChangKyoo;Choi, Sang Kyo;Chun, Hee Dong;Lee, In-Beum
    • Korean Chemical Engineering Research
    • /
    • v.44 no.6
    • /
    • pp.579-587
    • /
    • 2006
  • Recently, each country has been trying to promote Eco-Industrial Park (EIP) development for industrial sustainability. Technological modeling is required to realize EIP practically even though the project contains the political concerns for many companies, government, and self-governing bodies. The four main technologies of the EIP developments include energy exchange, material flow analysis, water pinch, and life cycle assessment. Material flow analysis (MFA) methodology can be utilized in EIP modeling in view of the fact that the analysis of material flows and the optimized modeling are major purposes for the technological modeling of EIP. Through MFA methodology in POHANG EIP project, how to apply MFA modeling to EIP modeling and how to utilize software for MFA modeling are shown in this research.

Pattern Classification of Volatile Organic Compounds in Various Indoor Environment (다양한 실내환경 중 휘발성유기화합물 오염의 패턴 분류)

  • Kim, Yoon-Shin;Roh, Young-Man;Lee, Cheol-Min;Kim, Ki-Youn;Kim, Jong-Cheol;Jun, Hyung-Jin
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.1 s.94
    • /
    • pp.49-56
    • /
    • 2007
  • The purpose of this study was to survey the distribution patterns of volatile organic compounds(VOCs) and formaldehyde in the various indoor environments using cluster analysis. We investigated VOCs and formaldehyde in subway stations, underground shopping areas, medical centers, maternity recuperation centers, public childcare centers, large stores, funeral houses, and indoor parking lots from June,2005 to May,2006. Concentration of TVOCs in maternity recuperations was 2,605.7 ${\mu}g/m^3$ that was higher than the guideline and other facilities. TVOCs in public childcare centers was 1,951.6 ${\mu}g/m^3$ also it exceeded the guideline. Moreover, concentration of TVOCs in every facility exceeded the guideline of Department of Environment, Korea. In case of formaldehyde, mean concentration, 336.5 ${\mu}g/m^3$, in only public childcare centers exceeded the 120 ${\mu}g/m^3$ of the guideline. Finally, by applying cluster analysis, three pattterns of the indoor air pollutions were distinguished. In the results of analysis, concentrations of TVOCs and formaldehyde of cluster 3 were higher than cluster 1 and 2 that were 2,561.4 ${\mu}g/m^3$ and 184.9 ${\mu}g/m^3$, respectively.

Impact of COVID-19 Infection on Work Functioning in Japanese Workers: A Prospective Cohort Study

  • Makoto Okawara;Keiki Hirashima;Yu Igarashi ;Kosuke Mafune ;Keiji Muramatsu ;Tomohisa Nagata ;Mayumi Tsuji ;Akira Ogami ;Yoshihisa Fujino
    • Safety and Health at Work
    • /
    • v.14 no.4
    • /
    • pp.445-450
    • /
    • 2023
  • Background: The impact of COVID-19 infection on workers' work function persists even after the acute phase of the infection. We studied this phenomenon in Japanese workers. Methods: We conducted a one-year prospective cohort study online, starting with a baseline survey in December 2020. We tracked workers without baseline work functioning impairment and incorporated data from 14,421 eligible individuals into the analysis. We estimated the incidence rate ratio for new onset of work functioning impairment due to COVID-19 infection during follow-up, using mixed-effects Poisson regression analysis with robust variance. Results: Participants reporting infection between January and December 2021 showed a significantly higher incidence of new work functioning impairment (adjusted incidence rate ratio: 2.18, 95% confidence interval: 1.75-2.71, p < 0.001). The formality of the recuperation environment correlated with a higher risk of work functioning deterioration in infected individuals (p for trend <0.001). Conclusion: COVID-19-infected workers may continue to experience work difficulties due to persistent, post-acute infection symptoms. Companies and society must urgently provide rehabilitation and social support for people with persistent symptoms, recognizing that COVID-19 is not just a transient acute infection.

Indoor exposure to hazardous air pollutants and volatile organic compounds in low-income houses in Lagos, Nigeria

  • Luqmon, Azeez;Musa, Olaogun;Mariam, Adeoye;Abdulazeez, Lawal;Babatunde, Agbaogun;Ibrahim, Abdulsalami;Adija, Majolagbe
    • Advances in environmental research
    • /
    • v.1 no.4
    • /
    • pp.277-288
    • /
    • 2012
  • This study investigated exposure to air pollutants in rooms in low-income houses at Shomolu (R1), Mafoluku (R2) and Mushin (R3) in Lagos state. The concentrations of most measured exceeded limits of Illinois Department of Public Health (IDPH) for indoor air quality. Air quality index (AQI) in rooms studied was unhealthy for sensitive people in terms of CO, unhealthy in terms of $SO_2$ and very unhealthy in terms of $NO_2$ while moderate air quality was obtained in terms of $PM_{10}$ in most rooms. High concentrations of carbontetrachloride, formaldehyde and xylene measured could have been responsible for some of the health complaints of the occupants. Factor analysis shows that cooking with kerosene, use of gasoline generator and insecticide were the major contributors to indoor air pollution in these rooms. Therefore, there is need to urgently tackle poverty as all affected by these pollutants were poor who live in substandard houses without kitchens.

Temporal-spatial Analysis of Environmental Impact and Locational Characteristics for Industrial Complex Projectsin South Korea (산업단지 개발사업의 환경 영향 및 시공간적 입지 특성변화 분석)

  • Choi, Hyun-Jin;Park, Ji Hyeon;Park, Jong-Yoon
    • Journal of Environmental Impact Assessment
    • /
    • v.30 no.5
    • /
    • pp.317-327
    • /
    • 2021
  • Industrial complexes have have been played an important role in various aspects such as national industrial development, economic growth. However, it is a cluster of manufacturing facilities which has a great impact on the surrounding area and the overall domestic environment during the operation of the facility. In this study, environmental influences and siting characteristics of industrial complexes were investigated based on the environmental impact assessment report from 2009 to 2019. The development tendency of industrial complexes is continuous decline, and major development areas are Gyeonggi, Gyeongsang and Chungcheong areas. We also confirmed that the average area of defenestration due to industrial complex is on the decline. Furthermore, the residential area and educational facilities, and the exposed population affected by industrial complex is constantly increased.

The Determination of Ethyl Isocyanate and Propyl Isocyanate by GC/FID (에틸 이소시아네이트와 프로필 이소시아네이트의 GC/FID 분석)

  • Lee, Eun-Jung;Yoo, Chul;Choi, Hong-Soon;Park, Jun-Ho;Yoon, Ju-Song;Cho, Young-Bong
    • Environmental Analysis Health and Toxicology
    • /
    • v.15 no.1_2
    • /
    • pp.53-59
    • /
    • 2000
  • The purpose of this study is the development of the simple and precise determination method of ethyl isocyanate (EIC) and propyl isocyanate (PIC) through derivatization using secondary aliphatic amines by gas chromatography with flame ionization detector. The urea derivatives are quantitatively and simultaneously derived from EIC and PIC with secondary aliphatic amines such as dipropylamine, dibutylamine. and dipentylamine in methylene chloride, and confirmed by thin layer chromatography and gas chromatography with mass selective detector. For GC/FID, according to the increasing carbon atom of the amines, the retention time and peak area of the urea derivatives are increased. The instrumental detection limits for EIC and PIC were about 23.3∼34.8 $\mu\textrm{g}$ and 21.6∼28.9 $\mu\textrm{g}$, respectively.

  • PDF

A Study on the Performance Analysis of Environmental Improvement Fund for the Structural Advancement Project of the Old Industrial Complex (노후산업단지 구조고도화사업을 위한 환경개선펀드 성과분석에 관한 연구)

  • Kim, Jongha;Chung, Jaeho
    • Land and Housing Review
    • /
    • v.11 no.3
    • /
    • pp.21-31
    • /
    • 2020
  • This paper quantitatively analyzes the investment performance of the environmental improvement fund focusing on the sales effect and the housing benefit effect. The analysis of this study focused on the effects of sales and housing benefits for completed business sites among the business sites supported by the Environmental Improvement Fund. The analysis results are as follows. First, it appears that the sales effect of the completed workplace is effective compared to the amount of investment, so it seems that the purpose of industrial integration of the environment improvement fund is being achieved. Second, it was found that there are variations by workplace and region in housing benefits. This seems to be due to the fact that profitability can be neglected by reflecting the characteristics of residential facilities built by private businesses. The Environmental Improvement Fund is a policy fund that pursues both profitability and publicity. Therefore, it is necessary to transform the structure of the fund to expand support for industrial infrastructure with high publicity. To this end, it is necessary to establish a long-term management plan that equitably considers the profitability and publicity of the environmental improvement fund.

The Classification and Management Plan of City for Sustainable Development (도시의 지속가능한 발전을 위한 유형분류 및 관리방안)

  • Lee, Woo-Sung;Jung, Sung-Gwan;Park, Kyung-Hun;You, Ju-Han;Kim, Kyung-Tae
    • Journal of Environmental Impact Assessment
    • /
    • v.17 no.6
    • /
    • pp.335-348
    • /
    • 2008
  • The purpose of this study is to classify the cities on sustainability assessment score studied in advance using cluster analysis, to present efficient management and policy direction based on analysis of sustainability index in 45 cities of all over Gyeongsangnam and Gyeongsangbuk-do. According to the results of cluster analysis, 45 cities were classed into 4 clusters by "livable-welfare city", "environmental -ecological city", "scientific-technological city", and "industrial-economic city". The livable-welfare cities must keep superior environmental sustainability, promote small and medium sized business on regional characteristic. The environmental-ecological cities have to change agriculture into future environmental industry such as ecotourism, bio-industry and landscape agriculture. The scientific-technological cities are going to need support of government scale such as income enlargement of citizen and stable job security. Finally, the industrial-economic cities must increase environmental management plants and improve quality of life through securing green spaces, maintaining public peace and applying UIS because of low quality of environment and life.

An Analysis of Local Wind Field by Location of Industrial Complex using CALMET and ENVI-MET (CALMET 및 ENVI-MET를 이용한 산업단지 입지에 따른 국지 바람장 분석)

  • Song, Dong Woong
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.3
    • /
    • pp.417-429
    • /
    • 2012
  • In this study, a diagnostic wind model, CALMET and a micrometeorological numerical model, ENVI-MET were used to analyze the wind field in and out of the site designated for the industrial complex around Buron-myeon, Wonju, Gangwon-do. The results of modeling with CALMET showed that the air flow in industrial complex was little affected by the surrounding terrain. And the result of wind field analysis with ENVI-MET showed there are turbulent air flows such as cavity and wake around structures in the industrial complex, which can cause high-air pollution. Therefore, it is necessary to design the industrial complex considering the wind path according to wind directions.