• 제목/요약/키워드: Industrial Controller(PLC)

검색결과 80건 처리시간 0.029초

ERF와 산업용 콘트롤러를 이용한 FHA의 제어특성에 관한 연구 (A Study on the Control Characteristics of FHA by Using ERF and Industrial Controller)

  • 정성철
    • 한국공작기계학회논문집
    • /
    • 제14권1호
    • /
    • pp.95-100
    • /
    • 2005
  • Making the best use of the features of the electro-rheological(ER) valve, a two-port pressure control valve using ER fluids is proposed and manufactured. The ER-Valve characteristics are evaluated by changing the intensity of the electric field and the number of electrode. In addition, the performance of the plate type ER-Valve is investigated by change the particle concentration of the ER fluid. As only with electrical signal change to the ER-Valve in which ER fluid flowing, ER fluid flow is controlled, so development of simple ER-Valves have been tried. The ER-Valves and pressure drop check method are considered to be applied to the fluid power control system. Using the minかnぉd pressure control valve, a one-link manipulator with FHA in robot system is driven. As a result, it is experimentally confirmed that the pressure control valve using ER fluids is applicable to use in driving actuator. If it applies characteristics of the ER fluids, it will be able to apply in the control system fir the ER Valve which occurs from industrial controller(PLC).

산업용 장비에서의 액추에이터를 제어 하기 위한 DSP에서의 Modbus통신 구현과 제어 모듈 개발 (Development of DSP-based Modbus Communication Scheme and Control Module for Controlling Actuators in Industrial Equipment)

  • 김원준;곽동기;김동환
    • 대한기계학회논문집A
    • /
    • 제41권11호
    • /
    • pp.1109-1117
    • /
    • 2017
  • PLC 시스템은 자체 모듈에 의한 부분적 확장성을 지원하고 있지만, 확장을 위한 비용이 크고, 센서 및 기타 제어기들과의 언어 호환성 또한 문제가 되고 있다. 본 논문에서는 빠르게 변화하는 기술에 대처하기 위해 텍사스 인스트루먼트 사의 DSP(디지털 시그널 프로세서)를 이용하여 PLC를 대체 및 보조할 수 있는 시스템을 제안한다. 이 시스템은 기존 PLC의 기능을 통합적으로 구현하며, 범용으로 쓰이는 PLC 에 비해 속도가 빠르고, 약 50% 이상의 비용 절감이 가능하다. 또한, 모듈 형태의 24V의 범용 디지털 I/O핀을 구성함으로써 선택적으로 입력과 출력의 부분적 확장을 용이하게 하였다. 일반적 산업 장비의 제어를 위해 널리 사용되고 있는 모드버스 통신을 RS-485 인터페이스를 기반으로 DSP에서 구현함으로써, 장비 간 다대다 통신을 할 수 있도록 하였다.

공정제어에서 선택시퀀스를 위한 효율적인 리모트 콘트롤 제어방법 (An Efficient Method of Remote Control for Select Sequence in Process Control)

  • 공헌택;김치수;유정봉
    • 한국산학기술학회논문지
    • /
    • 제11권1호
    • /
    • pp.107-112
    • /
    • 2010
  • PLC를 사용한 제어시스템에서 SFC 언어를 사용하면 전체 공정의 흐름을 이해하기 쉽고 유지보수가 용이하다. SFC 언어는 단일 시퀀스, 선택 시퀀스, 병렬 시퀀스로 나누어지고, 여러 조건에 맞게 처리하는 선택시퀀스로 프로그램 할 때 선택분기 스텝에 에러가 발생하면 전체 공정이 정지하게 된다. 이 에러스텝이 전체 공정에 크게 영향을 안주는 공정이라면 전체 공정을 정지시키지 않고 에러를 처리하면 손실은 줄어들게 된다. 본 논문에서는 선택시퀀스에서 리모트 콘트롤을 사용하여 선택시퀀스를 효율적으로 제어하는 방법을 제시하고 적용 예를 통해 그의 타당성을 확인하였다.

SFC로 기술(記述)된 계층제어 구조에서 메모리 효율 향상 (Improvement of Memory Efficiency in Hierarchical Control Structure described by SFC)

  • 유정봉
    • 한국산학기술학회논문지
    • /
    • 제7권2호
    • /
    • pp.126-130
    • /
    • 2006
  • PLC는 산업용 제어시스템에서 널리 사용되고 있으며, 중요한 역할을 하고 있다. PLC에서 사용되는 언어중 SFC는 이산 제어 프로그램에서 순차제어 논리의 기술에 적합한 그래픽 언어이며, SFC로 공정제어 시스템을 구현할 때는 분산제어 구조와 계층제어 구조로 구현하게 된다. 계층제어 구조에서는 서브시스템 간에 동기를 맞추기 위해서 서브시스템은 별도로 구성하고 동기신호만을 주고받게 된다. 그러면 메모리 효율 및 시스템 성능이 좋지 않게 된다. 본 논문에서는 계층제어 구조에서 메모리 효율을 향상시키는 방법을 제안하였고, 실례를 통해 그의 타당성을 확인하였다.

  • PDF

SFC로 설계된 공정제어에서 개선된 단일 시퀀스 제어 방법 (Improved Method of Single Sequence Control in Process Control designed by SFC)

  • 유정봉;김민영;전호익
    • 반도체디스플레이기술학회지
    • /
    • 제6권2호
    • /
    • pp.1-4
    • /
    • 2007
  • Programmable Logic Controller(PLC) is the most widely utilized and plays an important role in industrial control system. Among PLC languages, Sequential Function Chart(SFC) is performed in small scale industrial process. On programming by SFC, a single sequence is utilized to control the simple process. In this paper, we propose the method that describe the improved single sequence and confirm its feasibility through an actual example.

  • PDF

PLC에서 구현한 PID 제어의 와인드업 현상 극복 (A breakthrough of PID control windup state using PLC)

  • 정태수;남제우;오연식;박용운;이영준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1793-1794
    • /
    • 2007
  • Since it has an advantage of possibility to control using experimentally given coefficient, PID Control is the most widely used method of control in the field of industry. However, since PID controller is not able to reflect the inherent characteristics of individual systems, it needs to be accompanied by additional techniques to supplement. Also, it has disadvantage that it is hard to find a satisfactory coeffi cient when the state of the system's dynamic characteristics and static characteristics are different each other. When the dynamic one shows up, it means the state of system shows a great amount of difference from that of desired such as the moment of beginning control or change of desired state. But, if the state of the system comes close to the desired state, the static characteristics shows up in the system. There are many solutions suggested to overcome problems according to the conversion of two examples of motion shown above. This paper is to confirm PID control's integration ingredient windup phenomenon, and experiment through technique of pre vention of windup actually using PLC(Programmable Logic Co ntroller), and to verify the change in characteristics of control.

  • PDF

지능적 에이전트에 의한 실시간 소프트웨어 PLC 편집기 및 실행엔진 개발 (Development of an Editor and Howling Engine for Realtime Software Programmable Logic Controller based on Intelligent Agents)

  • 조영임
    • 한국정보과학회논문지:소프트웨어및응용
    • /
    • 제32권12호
    • /
    • pp.1271-1282
    • /
    • 2005
  • PC-based control은 현재 제어분야에서 비약적 발전을 하고 있으나 일반 사용자들이 PC에서 PLC 프로그래밍하기에는 어렵다는 단점이 있다. 따라서 본 논문은 국제 PLC 표준언어로 제정된 5가지 언어 중 $90\%$이상 사용하는 LD언어에 대한 표준규격을 연구하고, 이것을 중간코드인 IL(Instruction List) 언어로 변환하고 기존 상용화된 편집기(Visual C++)에서 활용 가능한 표준 C코드로 변환함으로써 LD에 익숙한 사용자나 고급언어에 익숙한 사용자 모두 사용할 수 있는 편집기 및 실행엔진 기능을 갖춘 지능적 에이전트 기반의 통합 시스템 ISPLC(Intelligent Agent System based Software Programmable Logic Controller)를 개발하였다. ISPLC에서는 LD에서보다 C에서 논리오류 검출기능이 훨씬 용이하며, GUI기반 인터페이스를 제공하며 에이전트에 의한 프로그래밍 코드를 제공하므로 가독성이 높다. 이러한 LD->H->C로의 코드변환체제에 관한 연구는 국내외적으로 처음 시도되는 연구이다. ISPLC를 실제 실시간 교통량 제어 시스템(Real Time Traffic Control System)에 적용하여 현장 적응성이 우수한 실행엔진을 개발하여 시뮬레이션 하였으며, ISPLC는 오류검색 뿐 아니라 프로그래밍 시간을 매우 단축시켜줌을 알 수 있었다.

SFC로 기술된 매니지먼트 스텝에 의한 개선된 인터록의 실현 (Improved Implementation of Interlock Using Management Step Described by SFC)

  • 유정봉
    • 조명전기설비학회논문지
    • /
    • 제19권3호
    • /
    • pp.127-133
    • /
    • 2005
  • PLC는 산업용 제어시스템에서 가장 많이 사용되며, 중요한 역할을 하고 있다. 이러한 PLC에서 사용되는 언어에 대한 연구도 활발히 이루어지고 있다. PLC에서는 LD언어가 가장 많이 사용되고 있다. LD언어는 데이터의 흐름을 알 수 없고, 유지보수가 어렵다. 반면에 SFC는 제어의 흐름을 이해하기 쉽고 유지보수가 용이하지만 조건과 인터록 기술에 문제점이 있다. 본 논문에서는 매니지먼트 스텝을 사용한 인터록의 기술에 대한 방법을 제안하였고, 실례를 통해 그의 타당성을 확인하였다.

이산사건모델에 기반한 PLC 래더다이어그램 자동합성 (Synthesis of Ladder Diagrams for PLCs Based on Discrete Event Models)

  • 강봉석;조광현
    • 제어로봇시스템학회논문지
    • /
    • 제7권11호
    • /
    • pp.939-943
    • /
    • 2001
  • PLC(programmable Logic Controller)s essential components of modern automation systems encompassing almost every industry. Ladder Diagrams (LD) have been widely used in the design of such PLC since the LD is suitable for the modeling of the sequential control system. However, the synthesis of LD itself mainly depends on the experience of the industrial engineer, which may results in unstructured or inflexible design. Hence, in this paper, we propose a ladder diagram conversion algorithm which systematically produces LDs for PLCs based on discrete event models to enhance the structured and flexible design mechanism.

  • PDF

산업용 리프트의 제어로직 설계 및 PLC 프로그래밍을 위한 체계화 연구 (A systematic approach to the control logic design and PLC programming of a industrial lift)

  • 박노억
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1999년도 추계학술대회 논문집 - 한국공작기계학회
    • /
    • pp.452-457
    • /
    • 1999
  • The recent control system has been changed into the type of PLC(Programmable Logic Controller) control. Up to now, systematic approach of PLC programming or control logic design is not suggested. In this study, the design process of the control logic is systematized and concrete process in each step is suggested. This systematized approach lead developer to be convenient to implement control system. When some error is occurred in the system, this approach enable the developer to analyze the reason of error rapidly and the system is amended according to systematic information of the analysis. The example of control system implementation following this approach is introduced.

  • PDF