• Title/Summary/Keyword: Industrial Automatic Door

Search Result 16, Processing Time 0.022 seconds

Dynamical Mechanism Analysis of An Industrial Two-step Folding Automatic Door (2단 접이식 산업용 자동문의 동역학적 메카니즘 해석)

  • Yun, Seong-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.7
    • /
    • pp.821-826
    • /
    • 2011
  • This paper deals with an analysis of dynamic mechanism for the industrial two-step folding automatic door. A nonlinear equation of motion was derived in terms of folding angle to estimate driving forces. Based on this dynamic behavior, time taken during the door's opening well as their velocities were controlled so that the operating conditions can be obtained for the purpose of design. The stiffness of twisting spring was also investigated when the automatic door closed, because a dangerous accident takes place from the door's free falling. The current research will be a very useful tool in the near future for the dynamic analysis for the multi-step folding automatic door.

Dynamic Analysis of Impact Force Alleviation of Industrial Folding-type Automatic Door on Guide Rail (산업용 접이식 자동문 안내레일에 작용하는 충격하중 완화를 위한 동역학적 해석)

  • Yun, Seong-Ho;Park, Jong-Cheon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.4
    • /
    • pp.16-21
    • /
    • 2011
  • This paper described an analysis of dynamic mechanism for the industrial two-step folding automatic door using commercial software packages. Two modeling types of operating on the guide rail, the sliding one and the rolling, were adopted to investigate effects of impact force when the door ascends the guide rail. The magnitude of impact force was found very peaklike large over an initial duration of the door's moving up. The amount of damping coefficient for alleviating this shock was controlled to such a moderate degree that the operating conditions can be obtained for the purpose of design. Moreover the behavior of both dynamic stress and deformation were observed for acquirement of structural reliabilities of the combined guide rail and rolling mechanism. This research will be a very useful tool in the near future for the dynamic analysis of the multi-step folding automatic door.

Development of Automatic Operating System for Exit Door using RF (무선을 이용한 비상문 자동개폐 시스템 개발)

  • Lim Youn-Sub;Hwang Byung-Kon
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.11 no.1
    • /
    • pp.7-12
    • /
    • 2006
  • In this paper, we develop a control system with fire receiver and emergency light that controls (manages) emergency door by wireless signals which prevents crime but also helps evacuate in (fire) emergency. This automatic door operator can be installed on any buildings which have a problem of opening or shutting emergency doors, and it is especially good for buildings with high fire vulnerabilities such as complex buildings, apartments and multistoried buildings without easy control of rooftop doors.

  • PDF

A Study for the Screen Door System Driving Stiffness of Motor Control Method (모터 제어 방식의 스크린 도어 시스템 구동강성 검증)

  • Lee, Jung-Hyun;Lee, Seon-Bong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.4
    • /
    • pp.2385-2390
    • /
    • 2015
  • In the beginning run, urban railway had been required as transportation. But now days urban railway have stayed in the platform for long time, the platform is faced the problem that is improvement of environment as one of the living space. Thus, sliding automatic door on the basis of screen door have used in huge distribution market, hospital, restaurant and public office because it is comfortable that customer's convenience and entrance are controled. So screen door not only requires customer's convenience and safe, clean area and energy conservation but demands optimal design technology development of screen door system that is confirmed by element parts of design and confidence. In this paper, For secure confidence of screen door, after as modeling roller and frame's system, confirming the result for qualification of driving stiffness. And then it suggests that it is possible to increase performance and declines fraction defective of element's part.

A Study for the Screen Door Motor System Driving Stiffness of Dynamic Load Condition (스크린 도어 모터 시스템의 동하중 상태 구동강성 검증)

  • Lee, Jung-Hyun;Lee, Seon-Bong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.2
    • /
    • pp.164-170
    • /
    • 2016
  • The initial urban railway was only required to perform its role as means of transportation. As the time of staying in an underground platform was extended, it has been faced with the issues of environmental improvement as a living space. Therefore, the sliding automatic door, which is the basis of the screen door, is used widely for large distribution stores, hospitals, restaurants, and public offices for customers' convenience and as a convenient method to control access. Therefore, screen doors are required for the purpose of customers' convenience, securing safety, establishing pleasant station buildings, and energy savings. It would be also necessary to develop the optimal design technology for a screen door system through the design of element parts and to ensure reliability. Therefore, this paper calculated, interpreted, and verified the theoretical weight of the composition parts to verify the design drive hardness of the motor for screen doors necessary for the safety of subways.

Torsional Spring Design of Big Industrial Folding-type Automatic Door to Prevent Free Fall (접이식 자동문의 자유낙하 방지를 위한 토션 스프링 장치 설계)

  • Yun, Seong-Ho
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.590-593
    • /
    • 2011
  • 본 논문에서는 산업용으로 널리 사용되는 접이식 자동문의 개폐 거동을 관찰하기 위한 운동방정식이 유도 되었다. 특히 자동문이 자유 낙하할 때 갑작스런 닫힘으로 인하여 작업 환경에 초래할 위험을 방지하고자 토션 스프링을 사용하였다. 설정된 작동 시간 및 속도에 적합한 토션 스프링의 강성을 산정하였고, 이를 바탕으로 스프링의 제원을 결정하였다.

  • PDF

A Study on Automatic Position Detection System for the Detachable Mobile Seat of a Vehicle for the Handicapped (장애인 차량을 위한 탈착식 시트의 자동 위치감지시스템에 관한 연구)

  • Youn, Jae-Woong;Lee, Soo Cheol
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.17 no.7
    • /
    • pp.25-33
    • /
    • 2012
  • This paper deals with the development of automatic docking system for the detachable mobile seat(DMS) of a vehicle for the handicapped people who are unable to ride in a car by oneself. Although such vehicles for the handicapped already exist, there is a need for a vehicle with improved docking method for convenience. This paper presents an automatic docking system using two ultrasonic sensors. In order to identify the precise location of the mobile seat in front of the vehicle door, the capability of ultrasonic sensor for detecting the part edge is analyzed and mathematical modeling is performed to measure the exact location of the side edge. And also, this paper presents an automatic docking method using this sensor system and the car lift which is provided in the inside of the car.

Identification of Causes and Prevention Measures for Health Disorders Such as Erythema of Restaurant Workers in Manufacturing Company (제조사업장 식당 종사자의 홍반 등 건강장해 원인 규명 및 예방 방안)

  • Jee Yeon Jeong;Gwangyong Yi;Seung-Hyeon Park
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.34 no.3
    • /
    • pp.238-246
    • /
    • 2024
  • Objectives: A collective of workers in the company's cafeteria encountered symptoms such as stinging and watering in and around the eyes, a sensation of sand in the eyes, erythema, swelling, and peeling of the skin on the face and neck. The objective of this study is to pinpoint the causes of these symptoms and propose preventive measures. Methods: Following preliminary on-site investigations, worker interviews, and literature research, it was determined that the most probable cause of the symptoms was ultraviolet rays emitted from a UV sterilizer. Consequently, the study measured and assessed the effective amount of ultraviolet radiation emitted by the sterilizer. Results: When operating with the curtain-type door of the ultraviolet sterilizer open, it was observed to surpass the 0.1 μW/cm2 8-hour work exposure standard recommended by ACGIH TLV in most kitchen workspaces. The evaluation of the maximum allowable exposure time based on the distance from the ultraviolet sterilizer indicated only 4.2 seconds at a distance of 0.2 m with the curtain door open, and merely 1.7 minutes at a distance of 1 m. Conclusions: This study confirmed that the symptoms among restaurant workers emerged immediately after the installation of the ultraviolet sterilizer, and these symptoms were consistent with those associated with exposure to ultraviolet rays. Furthermore, the assessment revealed that the exposure level to ultraviolet rays could be exceeded established exposure standards. It was recommended that the existing ultraviolet sterilizer be replaced with one featuring a glass door, and facility improvements should be made, such as implementing an automatic mechanism to turn off the ultraviolet lamp when the door is opened.