• Title/Summary/Keyword: Induction ratio

Search Result 519, Processing Time 0.027 seconds

A Study for the Magnetic Loading and Electric Loading Ratio of AC Induction Motor for Traction Purpose (AC 견인용 유도전동기의 장하비에 관한 연구)

  • 권중록;박정태;이갑재;이정일;김기찬;이종인;김연달
    • Proceedings of the KSR Conference
    • /
    • 2000.11a
    • /
    • pp.674-679
    • /
    • 2000
  • Designing of the squirrel cage AC Traction Motor has many difficulties which has to be small size in order to be suitable into bogie frame, high efficiency and light weight. It means that induction motor for tractive purpose has to be different magnetic and electric loading ratio from industrial induction motor. This paper is devoted to an examination of how this ratio affects overall design concept and hence the main design points for traction motor. Also studied is tile changed coefficients of the magnetic and electric loading ratio squirrel cage induction motor for the traction purpose which has been already identified from tile reference book for industrial purpose induction motor.

  • PDF

A Study for the Magnetic and Electric Loading ratio of AC induction Motor for Traction Purpose (AC 견인전동기의 장하비 (裝荷比)에 관한 연구)

  • Kwon, J.L.;Park, J.T.;Lee, K.J.;Lee, J.Y.;Kim, K.C.;Lee, J.I.;Kim, Y.D.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.702-704
    • /
    • 2000
  • Designing of the squirrel cage AC Traction Motor has many difficulties which has to be small shape in order to be suitable into bogie frame, high efficiency and light weight. It means that induction motor for tractive efforts has to be different magnetic and electric loading ratio from industrial induction motor. This paper is devoted to an examination of how this ratio affects overall design concept and. hence the main design points for traction motor. Also studied is the changed coefficients of the magnetic and electric loading ratio squirrel cage induction motor for the traction purpose, which has been already identified from the referance book for industrial purpose induction motor.

  • PDF

Examination of Root Induction Ratio for Regeneration of Alfalfa by Medium Component (알팔파 재분화에서 배지조성에 따른 뿌리 유도율 조사)

  • 김기용;강경민;박근제;배은경;이인애;이병현;곽상수;조진기
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.23 no.2
    • /
    • pp.95-100
    • /
    • 2003
  • The alfalfa (Medicago sativa L.) callus was induced from seeds on SH medium contained $3\;mg/{\ell}$ of 2,4-D. Several regenerated alfalfa plants and many shoots were obtained by procedure of Kim et al. (1999); 1) incubation for 28~30 days on SH medium added $5\;mg/{\ell}$ of NAA and $2\;mg/{\ell}$ of Kinetin, 2) incubation for 3~5 days on SH medium added $11\;mg/{\ell}$ of 2,4-D and $1\;mg/{\ell}$ of kinetin. 3) incubation for 21~25 days on SH medium added $1.6\;g/{\ell}$ of ammonium sulfate and $5.75\;g/{\ell}$ of proline. To increase of root induction ratio on plant regeneration process of alfalfa, root induction ratio was examined on 8 kinds of medium, containing different amount of hormone and SH salt. Root induction ratio was higher on SH medium contained IBA than SH basal medium. In case 1.5 mg of IBA was added in SH medium, root induction ratio was the highest to 56.0% in this study. On the other hand, root induction ratio was higher on SH medium diminished SH salt amount to half volume and addition of IBA makes high root induction ratio, too. Thus, we conclude that the medium for root induction of alfalfa may be added $1.5\;mg/{\ell}$ of IBA and diminished SH salt amount to half volume.

Maximum Efficiency Drive of Vector-Controlled Induction Motors (벡터제어 유도전동기의 최대효율 운전)

  • Yoon, Duck-Yong;Choe, Gyu-Ha;Hong, Soon-Chan;Baek, Soo-Hyun;Lee, Eun-Woong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.1 no.1
    • /
    • pp.27-37
    • /
    • 1996
  • This paper proposes the control algorithm for maximum efficiency drive of PWM inverter - induction motor system with high dynamic performance. If the induction motor is driven under light load with rated magnetizing current, the Iron loss is excessively large compared with the codder loss which results in doer motor efficiency. Maximum efficiency drive of an induction motor can be achieved by controlling the magnetizing current to satisfy the optimal ratio that leads the total motor loss to be a minimum value at a given speed. The proposed control algorithm essentially uses vector control technique and adopts voltage decoupling control strategy to prevent the degradation of dynamic performance due to reduced magnetizing current. To verify the proposed method, digital simulations and experiments are carried out for a squirrel-cage induction motor with the rating of 2.2[kW].

  • PDF

Dynamic Simulation of Engine Torque for Hardware-in-the-loop Simulation (엔진 토크의 동적 시뮬레이션에 관한 연구)

  • 조한승;송해박;이종화;고상근
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.2
    • /
    • pp.94-110
    • /
    • 1997
  • In the present study, a mean torque predictive model has been proposed and experimentally validated. It includes induction air mass model, fuel delivery model and mean production mode. Air induction and fuel delivery model considering dynamic behaviors of air induction and fuel delivery were proposed to predict the air-fuel ratio excursions under transient condition. Torque function model reflects thermal efficiency, volumetric efficiency, friction and effect of spark timing. In the spark timing model, knock limit and acceleration retard are included. Experiments were carried out to validate the simulation model for the step changes of throttle at constant engine speed. The results show reasonable agreements between simulation and experiment at fully warmed condition. Using this model, fueling strategies are varied with fast throttle open and it can predict air-fuel ratio excursion and IMEP.

  • PDF

A Study on the Digital Control of Single Phase Induction Motor Driven by the Full Bridge Resonant Inverter(I) - The Current Characteristics of Full - bridge Resonant Inverter at Low Frequency - (전브리지 공진형 인버터에 의한 단상 유도전동기의 디지탈제어에 관한 연구(I) -저주파수에서 전브리지 공진형 이버터의 전류특성에 대하여-)

  • 노영오;박진길
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.17 no.3
    • /
    • pp.70-79
    • /
    • 1993
  • The application of A.C. motor to servo system is rapidly increased according to the recent advance of power electronics and digital control techniques. The induction motor which has a simple structure and needs less maintenance is used in the industrial field for the variable speed and position control recently. In this paper, the current characteristic of the full-bridge resonant inverter is studied by comparing with the computer simulation and the laboratory experiment when the ratio of forced frequency to the natural frequency and the ratio of conduction time to the period at the given frequency is changed. And then, the full-bridge resonant inverter is applied to the speed control of single phase induction motor.

  • PDF

Three Dimensional Simulation Model of Fuel Delivery Jet Pump (연료 송출용 제트펌프 3차원 전산해석 모델)

  • PARK, DAIN;YUN, JIN WON;YU, SANGSEOK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.3
    • /
    • pp.308-314
    • /
    • 2017
  • Jet pump in automotive fuel tank module is used to deliver fuel to fuel pump so that the pump is operated without aeration in suction side. In this study, three dimensional simulation model of jet pump is developed to understand performance variation over design parameters. Performance of jet pump is also investigated experimentally in terms of operating pressures. The experimental data is used to verify the three dimensional simulation model of jet pump. Verification results show that the three dimensional simulation model of jet pump is about 1% error with experiment. The simulations are conducted in terms of throat ratio and primary flow induction angle. As the throat ratio is increased, the flux ratio is trade-off at 3 times of throat diameter. On the other hand, as primary flow induction angle is increased, vapor pressure inside the nozzle is decreased. In summary, the results show that liquid jet pump has to be optimized over design parameters. Additionally, high velocity of induced flow is able to evolve cavitation phenomena inside the jet pump.

Loss Analysis of Three Phase Induction Motor Connected to Single Phase Source (단상전원에 접속된 3상 유도전동기의 손실분석)

  • Kim, Do-Jin;Jwa, Chong-Keun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.2
    • /
    • pp.121-126
    • /
    • 2008
  • This paper analyzes the losses of a Steinmetz connection three-phase induction motor which is supplied by a single-phase source. The T-type equivalent circuit which is taken no-load losses into account is used to determine phase converter capacitive reactances at starting and rated speed by using the condition of the minimum voltage unbalance. The starting and the operating capacitor are replaced at the slip of the same voltage unbalance factor points which are depicted using two capacitive reactances. The operation characteristics are investigated by comparing with those of three-phase balanced operation to find the feasibility of single-phase operation. To analyze the losses of this motor, the output power decrease factor(OPDF), the loss ratio(LR), the no load loss ratio(NLLR), the copper loss ratio(CLR), the stator copper loss ratio(SCLR), and the rotor copper loss ratio(RCLR) are defined and simulated in the whole slip range. The simulated results show that OPDF is maintained almost uniformly, LR is low at low speed and high at high speed, CLR is higher !ban NLLR, but CLR varies concavely and NLLR varies convexly at high speed, SCLR is low at low speed and high at high speed, but SCLR varies convexly at high speed, and RCLR is nearly opposite to SCLR.

Study on Distortion Ratio Calculation of Park's Vector Pattern for Diagnosis of Stator Winding Fault of Induction Motor (유도전동기의 고정자 권선고장 진단을 위한 팍스벡터 패턴의 왜곡률 연산에 대한 연구)

  • Yang, Chul-Oh;Park, Kyu-Nam;Song, Myung-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.4
    • /
    • pp.643-649
    • /
    • 2012
  • The diagnosis technique of stator winding faults based on Motor Current Signature Analysis(MCSA) was suggested. Park's vector pattern, the circle that is drawn by d-q transformed currents($i_d$, $i_q$), is widely used for stator winding faults detection. The current Distortion Ratio(DR), defined by the ratio of max axis and min axis of ellipse of Park's vector's pattern, was more simple and powerful method than the Park's vector pattern. In this study, a calculation method of distortion ratio of Park's vector pattern was suggested for auto diagnosis of stator winding short fault and usefulness of suggested calculation method of distortion ratio was verified through simulation using LabVIEW program.

Effect of cold reduction on the magnetic properties of the permalloy steel sheet (Permalloy 판재의 자기적 성질에 미치는 냉간 압연율의 영향)

  • Choi, S.J.;Kim, Y.H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1988.05a
    • /
    • pp.46-48
    • /
    • 1988
  • The effect of cold reduction ratio on magnetic properties of 45% Ni-Fe permalloy was studied. To know the relationship between the crystal orientation and the magnetic properties, the pole figure was measured by X-ray diffraction method. In the case of single rolled reduction, the coercive force decreased with cold reduction ratio monotonically, but the maximum permeability, induction and squreness increased drastically. In the case of double rolled reduction (total reduction ratio is 90%), the saturation and residual induction increased slightly with secondary reduction ratio, but the maximum permeability and the coercive force had the maximum and the minimum value at the 50/50% reduction ratio respectively. And strong {100} <100> pole was developed by increasing the cold reduction ratio.

  • PDF