• Title/Summary/Keyword: Induction Lamp

Search Result 42, Processing Time 0.038 seconds

Stability of hair-tail angling fishing boat according to the induction fishing lamp installation (인덕션 집어등을 설치한 갈치채낚기 어선의 복원성능)

  • Seongjae JEONG;Seongwook PARK;Myongkok JEONG;Geumcheol JEONG
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.59 no.1
    • /
    • pp.1-8
    • /
    • 2023
  • In this study, the stability of fishing boat inducing the change of fishing lamp in accordance with the installation of induction lamp in comparison with metal halide lamp was investigated. Inclining test for 8.55 ton class of hair-tail angling fishing boat was performed in order to find a GM and light weight. A stability calculation of the target fishing boat on the basis of KST-SHIP program was evaluated. The stability of the fishing boat with a metal halide lamp such as induction lamp according to the result obtained by the inclining test is slightly different, and the stability is not so much affected. Due to the induction lamp installation, the wind area increased by about 3.178 m2. Before installing the induction fishing lamp, G0M was found to be 0.209 at full load departure and 0.296 at departure from fishing ground. After installing the induction lamp, the full load departure condition is 0.178 and the fishing ground departure condition is 0.260. The G0M value before and after installation of the induction fishing lamp shows a difference of about 3% at the full load departure condition. The value of the critical angle of inclination definition showed a difference of about 16%. Despite these differences, it is lower than the regulations; it was confirmed that there will be no significant difference unless it is in an overloaded state.

Study of the Characteristic and Optimization of Induction Lamp according to Gas Pressure and Amalgam Type (고출력 무전극램프의 가스압 및 아말감종류에 따른 특성분석 및 최적화에 관한 연구)

  • Chung, Young-Il;Jung, Dae-Chul;Kim, Yong-Kab;Park, Dae-Hee
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.1
    • /
    • pp.23-30
    • /
    • 2017
  • Currently, road lightings are installed with less than 400W of existing metal halide lamps. These road lightings are being replaced by energy-saving lightings. Induction lamps are expected to be more actively replaced with targets for tunnel lighting and high ceiling lighting. Therefore, it is necessary to develop high efficiency, high power induction lamps system. In this study, the gas type & pressure, amalgam type were designed for the high power of the induction lamps. And induction lamp system was optimized through electrical, optical characteristics analysis. It is optimized to the gas pressure 300~350 [mmHg] for the discharge tube of high power induction lamp and ferrite core. The driving circuit matching was completed with a induction lamp using indium amalgam. The rated power consumption of the induction lamp was optimized with 250 W (rated ${\pm}10%$)

Comparison of the effect of fish gathering and spatio-temporal distribution of the largehead hairtail (Trichiurus leptueus) using induction and metal halide fishing-lamp (인덕션·메탈할라이드 집어등에 의한 갈치(Trichiurus leptueus)의 유집 효과 비교와 시공간 분포)

  • Geunchang, PARK;Seong-Wook, PARK;Si-Yeol, NOH;Wooseok, OH;Sunyoung, OH;Sara, LEE;Kyounghoon, LEE
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.58 no.4
    • /
    • pp.334-344
    • /
    • 2022
  • In this study, we used underwater acoustics to analyze the spatial and temporal distribution characteristics of largehead hairtail (Trichiurus leptueus) based on the luminous thronging of metal halide fishing lamps and induction fishing lamps. As a result, the illuminating power was approximately 1.3 times higher using the metal halide fishing lamp whereas the density of hairtals by distance was approximately 1.9 times higher using the induction fishing lamp. Regarding water depth distribution, hairtails were detected depths of 25-30 m during August and at all water depths in November as assessed using fishing lamps.

Light Output Characteristics of an Electrodeless Discharge Lamp Using H-Discharge of External Coil Configuration (외부코일형 전자유도결합방전을 이용한 무전극 램프의 광출력 특성)

  • Kim, Hyun-Gwan;Gwark, Jae-Young;Song, Sang-Bin;Yeo, In-Seon
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1401-1403
    • /
    • 1995
  • This paper investigates the light output characteristics of an electrodeless H-discharge lamp. The existing cylindrical fluorescent lamps were wound around with an induction coil of varying size, and were driven by RF power. The light output and the luminous efficacy were measured according to variations of the induction coil gap and the lamp power, respectively. The experimental results show that the luminous efficacy of the lamp is as much as existing electrodeless lamps and the luminous efficacy of lamps are high between 10W and 20W. Theoretical analyses using computer simulation show that the circuit matching is easier in the external coil configuration than in the internal one, and that the current and the power distributions near the coil are shower in t.

  • PDF

A Study on the characteristic analysis and optimization according to Ballast design of Induction Lamp (고출력 무전극램프의 점등회로 설계를 통한 특성분석 및 최적화에 관한 연구)

  • Chung, Young-Il;Jung, Dae-Chul;Park, Dae-Hee;Kim, Yong-Kab
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.1
    • /
    • pp.31-37
    • /
    • 2017
  • In this paper, we implemented for the development of a high output induction lamp system, which lamp design is optimized by gas type, mixing ratio, pressure and discharge tube size, amalgam type and mixing ratio, and characteristics of ferrite core in the lamp. It's the circuit design by improving the power factor and efficiency according to the driving method, which has analyzing the characteristics according to the waveform and frequency. Finally, luminaries design part for applying the optimal lighting system considering the surrounding environment, the characteristics of the lighting circuit for electrodeless lamp has analyzed and the improvement has been proceeded. In conclusion, the driving frequency has optimized at 135kHz with degrading $7{\sim}10^{\circ}C$ based on the results of the optical characteristics of the induction lamp on peak noise FET(Q3,Q4) damage.

Wired and Wireless Linked Remote Control for the Group Lighting System Using Induction lamps (무전극 램프를 이용한 그룹 조명 시스템의 유무선 연계 원격제어)

  • Yeon, Jae-Eul;Cho, Kyu-Min;Kim, Hee-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.243-245
    • /
    • 2005
  • This paper presents a wired and wireless linked remote control system. Ethernet based network communication is used for long distance management and 2.4GHz RF network is adopted for the local area communication between the main network and the ballast. For the effective remote control and management including dimming using wired and wireless linked digital communication networks, control circuit of the ballast is implemented with fully digital circuit using MCU and EPLD. In this paper, the proper frame structure is proposed for the digital-remote lighting-control system and the detailed system configurations including fully digital controlled ballast for the induction lamp are described.

  • PDF

Comparative Analysis on Lifetime of Fluorescent Induction Lamp (무전극 형광램프의 수명 비교 분석)

  • Jeon, Sang-Kyoo;Cho, Mee-Ryoung;Choi, Suk-Joon;Rho, Jae-Yeop;Lee, Se-Hyun;Shin, Sang-Wuk;Hwang, Myung-Keun;Lee, Do-Young;Yang, Seong-Yong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.202-204
    • /
    • 2008
  • This paper gives a comparative analysis on lifetime of the fluorescent induction lamp. We have treasured and analysed optical characteristics of circular type fluorescent induction lamps, which has A and B types, to estimate lifetime. In the result of analysis on lifetime, $B_{10}$ lifetime of A and B type lamps are 466 hours and 1,595 hours, respectively.

  • PDF

Electromagnetic Analysis of Induction Coil for Electrodeless Fluorescent lamps (무전극 형광램프를 위한 유도코일의 전자계 해석)

  • 김광수;이종찬;박대희;박성목
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.187-190
    • /
    • 2002
  • The Electrodeless lamp is intended as a high efficacy replacement for the incandescent reflector lamp in many applications. but Increasing awareness of electromagnetic compatibility(EMC) issues in lighting application, the problems of interference generation by electrodeless fluorescent lighting system have been highlighted. In this paper, Maxwell 2D finite element analysis program(Ansoft) is used to obtain electromagnetic properties associated with the coil and nearby structures. and also evaluated Flux B, H by changing the input current.

  • PDF

A Study on discharge gas of Fluorescent Induction Lamp (무전극 램프의 방전가스 연구)

  • Kim, Keun;Jeon, Byung-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1481_1482
    • /
    • 2009
  • Pure Xe, Kr and Ne atoms and Mixures of Xe-Ne used in fluorescent induction lamps(FILs). However standard regulation of FILs is not made up until now. Therefore, the electron transport coefficients, the electron drift velocity W, the longitudinal diffusion coefficient NDL and the ionization coefficient $\alpha$/N in pure Xe, Kr, Ne gases and Xe-Ne mixtures(1:9, 5:5, 7:3) were calculated over the wide E/N range from 0.01 to 500 Td at 1 Torr by two-term approximation of the Boltzman equation.

  • PDF

Electrical Characteristics of Antenna for Electrodeless Fluorescent Lamp Using the Electromagnetic Simulation (무전극 형광램프용 안테나 설계를 위한 전기적 특성 시뮬레이션)

  • Her, In-Sung;Kim, Kwang-Soo;Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05b
    • /
    • pp.61-64
    • /
    • 2004
  • Recently, the RF inductive discharge or inductively coupled plasma (ICP) continues to attract growing attention as an effective plasma source in many industrial applications, the best known of which are plasma processing and lighting technology. To the point of lighting sources, the electrodeless fluorescent lamps utilizing an inductively coupled plasma (ICP) have been objects of interest and research during the last decades, mainly because of their potential for extremely long life, high lamp efficacies, rapid power switching response. The electrodeless fluorescent lamp that is dealt with in this work comprises a bulb filled with rare gas and amalgam of vaporizable metal and has a coil provided with a winding around the ferrite. Current through a coil produces a magnetic field in the discharge space. The changing magnetic flux then produces an azimuthal electric field E around the coil, according to Faraday's laws of magnetic induction.

  • PDF