• 제목/요약/키워드: Induced current

검색결과 2,684건 처리시간 0.033초

Experimental study on vortex-induced motions of a semi-submersible with square columns and pontoons at different draft conditions and current incidences

  • Liu, Mingyue;Xiao, Longfei;Lu, Haining;Xiao, Xiaolong
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제9권3호
    • /
    • pp.326-338
    • /
    • 2017
  • The Vortex-induced Motions (VIM) phenomenon of semi-submersibles is relevant for the fatigue life of moorings and risers. Model tests regarding the VIM behavior of a semi-submersible with four square columns were conducted in order to investigate the effects of the current incidence and the aspect ratio of the immerged column. The experimental results show that the largest transverse amplitudes are around 70% of the column width at $30^{\circ}$ and $45^{\circ}$ incidences in a range of reduced velocities from 5 to 8 when the aspect ratio of the immerged column is 1.90. The largest yaw motion occurs at $0^{\circ}$ incidence with the peak value around $4.5^{\circ}$. Similar characteristics of the VIM response are observed for the semi-submersible with aspect ratios of 1.90 and 1.73. When the aspect ratio decreases 50% to 0.87, 30% decrease in the peak transverse amplitudes can be seen.

2개 유전체층 위의 완전도체띠 격자구조에 의한 TM 산란의 급속한 수렴 해 (Fast Convergent Solution of TM Scattering by Conducting Strip Grating on Two Dielectric Layers)

  • 윤의중
    • 한국항행학회논문지
    • /
    • 제18권1호
    • /
    • pp.78-83
    • /
    • 2014
  • 본 논문에서는 2개 유전체층 위의 완전도체띠 격자구조에 의한 TM (transverse magnetic)산란의 급속한 수렴 해에 대한 문제를 수치해석 방법인 FGMM (Fourier Galerkin moment method)를 이용하여 해석하였다. TM 산란에 대하여 유도되는 표면 전류밀도는 스트립 양 끝에서 매우 큰 값이 예측되므로, 이때 스트립에 유도되는 전류밀도는 적절한 모서리 경계조건을 만족하는 함수와 1종 Chebyshev 다항식의 곱의 급수로 전개하였다. 도체띠에 유도되는 전류밀도, 정규화된 반사전력 및 투과전력을 계산하였다. 제안된 함수를 사용한 수치결과는 기존의 지수함수를 사용했을 때 보다 빠르게 수렴도가 향상되었으며, 수치결과들은 기존 논문들의 결과들과 비교하여 거의 일치하였다.

터빈 습분분리재열기 Type-439 스테인리스강 튜브 와전류검사 (Eddy Current Testing of Type-439 S/S Tube of MSR in Turbine System)

  • 이희종;조찬희;정지홍;문균영
    • 한국압력기기공학회 논문집
    • /
    • 제4권2호
    • /
    • pp.50-56
    • /
    • 2008
  • The tubes in heat exchanger are typically made of copper alloy, stainless steel, carbon steel, titanium alloy material. Type-439 ferritic stainless steel is ferromagnetic material, and furnish higher heat transfer rates than austenitic stainless steels and higher resistance to corrosion-induced flaws. Ferritic stainless steel can be found in low-pressure(LP) feedwater heaters and moisture separator reheaters(MSRs) in turbine system. LP feedwater heaters generally utilize thin wall Type-439 stainless steel tubing, whereas MSRs typically employ a heavier wall tubing with integral fins. Service-induced damage can occur on the O.D(outside diameter) surface of Type-439 ferritic stainless steel tubing which is employed for MSRs tubing, and the most typical damage mechanism is vibration-induced tube-to-TSP(tube support plate) wear and fatigue cracking. The wear has been reported that occurs mainly on the OD surface. Accordingly, in this study, we have evaluated the flaw sizing capability of magnetic saturation eddy current technique using magnetic saturation probe and flawed specimen.

  • PDF

항내매몰을 고려한 방파제의 시공순서 검토 (Analysis of Construction Procedure of Breakwater in consideration of Harbor Siltation)

  • 윤성진;김규한
    • 한국해안해양공학회지
    • /
    • 제19권1호
    • /
    • pp.73-80
    • /
    • 2007
  • 동해안에 위치한 어항이나 항만은 주 외력으로서 파랑이 탁월한 특징을 갖고 있다. 아울러, 동해안에 존재하는 강한 해빈류는 어항구조물 주변의 표사이동에 매우 큰 영향을 미친다. 따라서 동해안에 어항이나 항만을 건설할 때에는 설계 시에 해빈류에 기인한 항만 주변의 표사이동 특성을 명확히 검토해야 할 필요가 있다. 본 연구에서는 연도별 해안선변화에 대한 측량자료 및 방파제 주변의 상세 수심측량자료를 이용하여 방파제 시공순서가 항내매몰 및 주변 표사이동에 미치는 영향에 대하여 구체적으로 파악하고자 하였다. 그리고 동해안에 건설되는 어항구조물의 항내에 발생하는 퇴사량 감소를 위한 보다 효율성 있는 시공순서에 대하여 검토하였다.

460[V]/400[A]/85[kA] 배선용 차단기의 아크런너 변형을 통한 차단성능 향상 (Improvement of Short Circuit Performance in 460[V]/400{A]/85(kA] Molded Case Circuit Breakers)

  • 이승수;허준;윤재훈;강성화;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.394-394
    • /
    • 2009
  • Owing to the increasing number of intelligent homes(or called Smart home), the corresponding cost is much higher. Low voltage circuit breakers are widely used in the intelligent homes to interrupt fault current rapidly and to assure the reliability of the power supply. The distribution of magnetic field induced by arc current in the contact system of molded case circuit breaker(hereafter MCCB) depends on the shape, arrangement, and kinds of material of arc runner. This paper is focused on understanding the interrupting capability, more specifically of the arc runner, based on the shape of the contact system in the current MCCB. The magnetic driving force was calculated by using the flux densities induced by the arc current, which are obtained by three-dimensional finite element method. There is a need to assure that the optimum design required to analyze the electromagnetic forces of the contact system generated by current and the flux density be present. This is paper present our computational analysis on contact system in MCCB.

  • PDF

460[V]/400[A]/85[kA] 배선용 차단기의 그리드 및 아크런너 변형을 통한 차단성능 향상 (Improvement of Short Circuit Performance in 460[V]/400[A]/85[kA] Molded Case Circuit Breakers)

  • 이승수;정의환;윤재훈;강성화;임기조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1451_1452
    • /
    • 2009
  • Owing to the increasing number of intelligent homes(or called Smart home), the corresponding cost is much higher. Low voltage circuit breakers are widely used in the intelligent homes to interrupt fault current rapidly and to assure the reliability of the power supply. The distribution of magnetic field induced by arc current in the contact system of molded case circuit breaker depends on the shape, arrangement, and kinds of material of grids. This paper is focused on understanding the interrupting capability, more specifically of the grid and the arc runner, based on the shape of the contact system in the current MCCB. The magnetic driving force was calculated by using the flux densities induced by the arc current, which are obtained by three-dimensional finite element method. There is a need to assure that the optimum design required to analyze the electromagnetic forces of the contact system generated by current and the flux density be present. This is paper present our computational analysis on contact system in MCCB.

  • PDF

Calcium permeability of transient receptor potential canonical (TRPC) 4 channels measured by TRPC4-GCaMP6s

  • Ko, Juyeon;Myeong, Jongyun;Yang, Dongki;So, Insuk
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제21권1호
    • /
    • pp.133-140
    • /
    • 2017
  • Conflicting evidence has been obtained regarding whether transient receptor potential cation channels (TRPC) are store-operated channels (SOCs) or receptor-operated channels (ROCs). Moreover, the Ca/Na permeability ratio differs depending on whether the current-voltage (I-V) curve has a doubly rectifying shape or inward rectifying shape. To investigate the calcium permeability of TRPC4 channels, we attached GCaMP6s to TRPC4 and simultaneously measured the current and calcium signals. A TRPC4 specific activator, (-)-englerin A, induced both current and calcium fluorescence with the similar time course. Muscarinic receptor stimulator, carbachol, also induced both current and calcium fluorescence with the similar time course. By forming heteromers with TRPC4, TRPC1 significantly reduced the inward current with outward rectifying I-V curve, which also caused the decrease of calcium fluorescence intensity. These results suggest that GCaMP6s attached to TRPC4 can detect slight calcium changes near TRPC4 channels. Consequently, TRPC4-GCaMP6s can be a useful tool for testing the calcium permeability of TRPC4 channels.

The Impact of Gate Leakage Current on PLL in 65 nm Technology: Analysis and Optimization

  • Li, Jing;Ning, Ning;Du, Ling;Yu, Qi;Liu, Yang
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제12권1호
    • /
    • pp.99-106
    • /
    • 2012
  • For CMOS technology of 65 nm and beyond, the gate leakage current can not be negligible anymore. In this paper, the impact of the gate leakage current in ring voltage-controlled oscillator (VCO) on phase-locked loop (PLL) is analyzed and modeled. A voltage -to-voltage (V-to-V) circuit is proposed to reduce the voltage ripple on $V_{ctrl}$ induced by the gate leakage current. The side effects induced by the V-to-V circuit are described and optimized either. The PLL design is based on a standard 65 nm CMOS technology with a 1.8 V power supply. Simulation results show that 97 % ripple voltage is smoothed at 216 MHz output frequency. The RMS and peak-to-peak jitter are 3 ps and 14.8 ps, respectively.

가열된 금형에 삽입된 구리전극에 의한 중첩된 알루미늄 합금판재의 드로잉성형 동시 점용접 특성 (Characteristics of Drawing and Concurrent Spot Welding of Overlapped Aluminum Plates with Copper Electrodes Inserted in Heated Dies)

  • 김태현;진인태
    • 소성∙가공
    • /
    • 제26권3호
    • /
    • pp.174-180
    • /
    • 2017
  • In this study, a new spot welding with electric resistance heated dies is suggested for the spot welding of non-ferrous metal plates for drawing and concurrent spot welding. This welding method involves two heating processes such as heating by conduction of electric resistance heated dies and heating by resistance between contacted surfaces of two plates by welding current induced to copper dies for the fusion of contacted metal. This welding process has welding variables such as current induced in heated and copper dies, the inner diameters of heated dies, and edge shape of the copper dies. Experimental conditions for each current should be established to get successful welding strength. The welding strength could reach to the desired value in industrial fields under the following conditions of contact diameters of heated dies in this case of overlapped aluminum5052 plates with 0.3-mm thickness: inner and outer diameters of 5.0 and 16mm, respectively; diameter of copper dies, 5.0mm; heating current, 6.8kA in heated steel dies; welding current, 8.6 kA in copper dies.

Current-induced Phase Demodulation Using a PWM Sampling for a Fiber-optic CT

  • Park, Hyoung-Jun;Lee, June-Ho;Kim, Hyun-Jin;Song, Min-Ho
    • Journal of the Optical Society of Korea
    • /
    • 제14권3호
    • /
    • pp.240-244
    • /
    • 2010
  • In this work, we used PWM sampling for demodulation of a fiber-optic interferometric current transformer. The interference signal from a fiber-optic CT is sampled with PWM triggers that produce a 90-degree phase difference between two consecutively sampled signals. The current-induced phase is extracted by applying an arctangent demodulation and a phase unwrapping algorithm to the sampled signals. From experiments using the proposed demodulation, we obtained phase measurement accuracy and a linearity error, in AC current measurements, of ~2.35 mrad and 0.18%, respectively. The accuracy of the proposed method was compared with that of a lock-in amplifier demodulation, which showed only 0.36% difference. To compare the birefringence effects of different fiber-optic sensor coils, a flint glass fiber and a standard single-mode fiber were used under the same conditions. The flint glass fiber coil with a Faraday rotator mirror showed the best performance. Because of the simple hardware structure and signal processing, the proposed demodulation would be suitable for low-cost over-current monitoring in high voltage power systems.