실공간 사용 공기조화기용 열교환기의 공기측 파울링 특성 예측 (Prediction of Characteristics for the Air-side Particulate Fouling in Finned-Tube Heat Exchangers of Air Conditioners used in the Field)

  • 안영철;정성학;황유진;이창건;김두현;정성일;이재근
    • 설비공학논문집
    • /
    • 제19권8호
    • /
    • pp.563-568
    • /
    • 2007
  • The air-side particulate fouling in the heat exchangers of HVAC applications degrades the performances of cooling capacity, pressure drop across a heat exchanger, and indoor air quality. Indoor and outdoor air contaminants foul heat exchangers. An empirical modeling equation has been derived from the experimental results using accelerated tests and it showed good predictions of the fouling characteristics of the slitted finned tube heat exchangers. However the modeling equation predicts only the fouling characteristics of new heat exchangers and it can not predicts fouling characteristics obtained from actual field data which contains the effect of hydrophilicity deterioration. Therefore an modified modeling equation is proposed and it shows good predictions of the actual fouling characteristics of finned-tube heat exchangers.

외부소음에 대한 공동주택 실내 소음레벨분포에 관한 실험적 연구 (An Experimental Study on the Prediction of Indoor Sound Level Distribution in Apartment for Exterior Noise)

  • 박현구;김종빈;강동영;장현충;송혁;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.259-264
    • /
    • 2001
  • It is necessary to predict the sound pressure level(SPL) in rooms before designing an apartment when exterior noises are produced. In order to predict SPL for an apartment that has some specific exterior noises, the following should be known: the characteristics of outdoor noise, sound insulation performance and sound level differences of each room. The purpose of this study is to find out the possibility of predicting sound pressure level of rooms in an apartment by analysing sound level differences among rooms. Sound sources used in this experiment are construction noise, aircraft noise, railroad noise, road traffic noise and white noise as a reference to compare with the previous four. These noises were recorded and reproduced by speaker. As a result, we found that within the sound reduction pattern, the sound difference level appeared uniform depending on the sound insulation characteristics of the windows installed when facing the noise source. When the windows having the same acoustic performance were installed, the SPL in each room resulted in nearly the same values.

  • PDF

냉동시스템의 운전조건에 따른 열교환기 내장형 어큐뮬레이터의 성능 특성 (Performance Characteristics of Accumulator Heat Exchangers with Operating Conditions of a Refrigeration System)

  • 강훈;박차식;전종욱;김용찬
    • 설비공학논문집
    • /
    • 제18권12호
    • /
    • pp.984-991
    • /
    • 2006
  • The applications of multi air-conditioners into multiplex and high-rise buildings have been increased by replacing central air-conditioning systems. The pipe length and altitude difference between the indoor and outdoor units can be increased based on installation conditions, which may increase the possibility of flash gas generation at the expansion device inlet. The flash gas generation causes rapid reduction of refrigerant flow rate passing through the expansion device, yielding lower system efficiency. Accumulator heat exchangers have been widely used in multi air-conditioners in order to minimize flash gas generation and obtain system reliability. However, the studies on the heat transfer characteristics and pressure drops of accumulator heat exchangers are very limited in open literature. In this study, the heat transfer rates and pressure drops of accumulator heat exchangers were measured with refrigerant flow rate and operating conditions by using R-22. The heat transfer rate increased with the increase of refrigerant flow rate, while subcooling decreased. The heat transfer rate enhanced with the reduction of inlet superheat and subcooling due to the increased temperature difference between the accumulator and inner heat exchanger.

신축공동주택의 기밀성능 실측에 관한 연구 (The Field Measurement of Airtightness in the Apartment Buildings)

  • 박원석;윤재옥
    • KIEAE Journal
    • /
    • 제3권3호
    • /
    • pp.43-50
    • /
    • 2003
  • Nowdays the apartment is a main type of modernized residential buildings. According to the improvement of construction techniques and functions of windows and doors, recent apartments are enhanced air tightness of windows, doors and building envelopes. As Infiltration is decreased and natural ventilation is reduced, energy could be saved in winter. However, indoor air quality is bad. The air Infiltration of a building could be enlarged by physical actions, such as building designs, constructions and reduction of air tightness which is caused by aging. This research analyzes and measures with KNS-4000P (Sapporo air tightness measurement) the air tightness of the high rise apartments which is recently constructed and not occupied yet. With depressurization method, the KNS-4000 installed on the window and the indoor air-leakage was measured. At that time, Air come out from the edge of the windows and doors because of the pressure differences between indoor and outdoor. We measure the amount of the air as effective air leakage areas. This method of depressurization takes less time to measure than other methods and is less affected from other conditions. We measured infiltration of total 56 household, 29 households S apartment (total floor area : $64.42m^2$) in Balan and 29 households D apartment(total floor area : $78.21m^2$) in Chonan. As a result of the field measurements at October 2003, normalized leakage area of D apartment in Cheonan was $2.05cm^2/m^2{\sim}3.49cm^2/m^2$ (average: $2.77cm^2/m^2$) and normalized leakage area of S apartment in Balan is $1.23cm^2/m^2{\sim}1.68cm^2/m^2$ (average: $1.5cm^2/m^2$).

지반조건과 신발의 종류에 따른 족저압 분포 (Plantar foot pressure distribution depending on ground conditions and shoe type)

  • 김상환;이혜윤;김연덕
    • 한국산학기술학회논문지
    • /
    • 제16권4호
    • /
    • pp.2899-2905
    • /
    • 2015
  • 본 논문은 지반 조건에 따른 족저압의 압력분포에 대한 연구이다. 실내화, 실외화, 걷기화, 운동화의 네 가지 카테고리의 신발이 본 연구에 사용되었으며, 260mm(유럽 코드 EU40)를 착용하는 45명의 20대 남성을 대상으로 콘크리트, 모래 지반에서의 실험을 실시하였다. 보행 시 응력과 압력의 측정은 Techstorm사의 Insole System을 사용하여 측정하였으며 발의 발가락, 전족, 중족, 후족 네 가지 영역에서 족저압을 측정하였다. 연구 결과 신발과 지반 조건에 따라 다른 응력 및 압력의 분포를 나타냈으며 본 연구 결과는 모래 지반에서 착용 가능한 신발의 개발에 유용하게 사용될 것으로 기대된다.

제주지역 고층건축물에서의 바람의 영향이 굴뚝효과에 미치는 영향 분석 (서울과 제주지역간의 비교 분석) (Influence of Stack Effect in High-Rise Buildings on Wind Effect in Jeju (Comparative Analysis of Seoul and Jeju))

  • 임채현
    • 한국화재소방학회논문지
    • /
    • 제29권6호
    • /
    • pp.6-12
    • /
    • 2015
  • 본 연구에서는 상대적으로 바람이 강한 제주지역에서 바람의 영향이 고층건축물의 굴뚝효과에 어떠한 영향을 미치는지를 분석하기 위해 서울소재 고층건축물을 대상으로 서울과 제주지역에서의 지형 및 기상조건을 각각 대입하여 CONTAM 모델링을 실시하였다. 굴뚝효과에 의한 차압은 수직샤프트의 높이와 실내 외 온도차의 함수로서 같은 높이의 건축물에서는 겨울철 서울보다 상대적으로 외기온도가 따뜻한 제주지역에서의 차압이 서울지역의 60% 정도에 그쳐 비교적 안정적인 것으로 판단되어 왔다. 그러나 제주도는 섬지역으로서 서울보다 강한 바람의 영향에 의해 중성면이 56% 이상 큰 폭으로 상승하는 현상을 보였는데, 이는 비록 제주지역이 서울보다 굴뚝효과에 의한 차압은 적게 나타날지라도 상승된 중성면에 의해 저층부에서 형성되는 부압의 영역이나 크기는 넓고 크게 나타나 위험성이 상대적으로 높은 것으로 판단되었다.

자연 노화에 따른 카본 에폭시 압력용기의 섬유 인장 강도 변화 (Natural Aging Effect on the Fiber Tensile Strength of Carbon Epoxy Pressure Vessel)

  • 황태경;박재범;김형근;도영대
    • Composites Research
    • /
    • 제20권2호
    • /
    • pp.1-9
    • /
    • 2007
  • 카본 에폭시로 제작된 복합재 압력용기의 노화 특성과 구조 사용 수명 평가를 위해 실내와 실외에서 10년과 15년간 자연노화 시켰다. 노화 특성의 통계적 분포를 구하기 위해 노화된 압력용기로부터 링 시편을 채취하여 수압 파괴 시험을 실시하였다. 그리고 섬유와 수지 계면의 노화 특성 확인을 위해 시험 파편 계면을 SEM을 이용하여 관찰하였다. 섬유 인장 파손 변형률의 와이블 파라미터 값 기준으로 실내에서 10년, 15년 노화되었을 경우 각각 19%와 23% 저하되었으나, 실내와 실외의 노화 특성 차이는 크지 않았다. 그러나 압력용기 외면에 적용한 표면 페인트는 노화 방지에 큰 효과를 나타내었다.

듀얼 냉동사이클을 이용하는 특수목적 자동차용 에어컨 시스템의 냉방성능에 관한 연구 (Investigation on the Performance of Special Purpose Automotive Air-Conditioning System Using Dual Refrigeration Cycle)

  • 서재형;방유마;이무연
    • 대한기계학회논문집B
    • /
    • 제40권4호
    • /
    • pp.213-220
    • /
    • 2016
  • 본 연구의 목적은 열대 지방에서 사용되는 특수목적 자동차용 에어컨 시스템의 냉방성능 특성을 고찰하는 것이다. 이를 위하여 R-134a를 사용하는 듀얼 냉동사이클을 구성하였고 냉매량 및 실내온도를 변화시켜가면서 냉방성능을 비교하였다. 외기온도 $40.0^{\circ}C$에서 듀얼 냉동사이클의 실내 냉각속도 및 압축비(토출압력) 등을 고려하여 최적 냉매량을 1.5kg으로 선정하였다. 실내온도가 증가할수록 냉방부하가 증가하여 $25.0^{\circ}C$에서 $32.5^{\circ}C$로 실내온도를 높일 경우 $15.0^{\circ}C$에 도달하는데 걸리는 시간은 86.5% 증가하였고, $32.5^{\circ}C$에서 $40.0^{\circ}C$로 증가할 경우 38.1% 증가하였다. 또한, 실내온도가 $25.0^{\circ}C$에서 $40.0^{\circ}C$로 증가할수록 냉방용량은 19.1 kW에서 20.5 kW로 7.3% 증가했으나 냉방성능(COP)는 4.67에서 5.1로 7.0%감소하였다.

초고층건물 샤프트의 수직구획이 연돌효과 및 급기가압 성능에 미치는 영향 (The Influence of Zoning at Shafts of Super-tall Buildings on the Stack Effect and Stairwell Pressurization)

  • 김범규;김학중;여용주;임채현;박용환
    • 한국화재소방학회논문지
    • /
    • 제26권5호
    • /
    • pp.92-98
    • /
    • 2012
  • 최근 개정된 초고층건물 특별법에서는 피난안전구역을 최소 30개층 마다 설정함과 동시에 계단실을 수직구획 하도록 규정하고 있다. 이에 본 연구에서는 중앙코아 방식의 80층 초고층건물 계단실 수직구획이 연돌효과 및 계단실 급기가압 성능에 미치는 영향을 시뮬레이션 해석을 통해 분석하였다. 해석결과, 계단실 수직구획이 없는 경우 연돌효과로 인해 최대 차압 250 Pa 이상이 발생하였으며, 계단실만 수직구획한 경우에는 10 Pa 정도만 감소하였으나 계단실과 승강기의 승강로를 동시에 수직구획한 경우 최대차압이 약 125 Pa로 낮아져 연돌효과가 약 50 % 감소하였다. 또한, 계단실을 급기가압 할 경우 계단실온도가 실내온도와 외기온도 차이의 약 1/2일 때가 소요급기풍량 측면에서 가장 효율적인 것으로 예측되었다.

화재현장에서 사용하는 소방호스의 마찰손실 감소 방안에 관한 연구 (A Study on the Friction Loss Reduction in Fire Hoses Used at a Fire Scene)

  • 민세홍;권용준
    • 한국화재소방학회논문지
    • /
    • 제27권3호
    • /
    • pp.52-59
    • /
    • 2013
  • 본 연구에서는 화재현장에서 사용하는 소방호스에 대하여 사용압력과 방수량 변화에 따른 마찰손실을 실측하였다. 소방호스의 종류, 수량, 사용압력 등 소방호스의 사용 실태를 분석하여 그 결과를 토대로 실측한 결과 화재현장에서 소방공무원이 사용하는 조건에서 소방호스의 마찰손실은 무려 56.8%까지 측정되었다. 옥내 외 소화전설비에서 펌프양정 계산시 사용하는 소방호스의 등가 길이와도 많은 차이가 난다. 관련규정조차 마찰손실에 대한 제한 규정이 없고, 소방호스를 생산하는 업체에서도 마찰손실을 측정한 자료가 없으며, 화재현장에서는 마찰손실을 고려하지 않고 소방호스를 전개함으로써 호스의 사용량이 많아지고 소방펌프차에서 고압으로 방수하게 되는 원인이 되므로 본 연구를 통하여 소방호스 마찰손실에 대한 등가길이 기준을 정립하고 화재현장에서 소방호스의 마찰손실을 고려한 전개 방법을 제안하고자 한다.