• 제목/요약/키워드: Indoor-outdoor air quality

검색결과 171건 처리시간 0.024초

배기열 회수용 종이 열교환기의 성능에 관한 연구 (A Study on the Performance of Paper Heat Exchanger for Exhaust Heat Recovery)

  • 유성연;정민호;최재호;권화길;이춘우;이기성
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.245-250
    • /
    • 2003
  • In order to control indoor air quality and save energy, it is needed to install a suitable ventilation system equipped with heat exchanger for heat recovery. The purpose of this research is to find the performance of paper heat exchanger for exhaust heat recovery, which exchanges latent heat as well as sensible heat. Experimental apparatus comprises heat exchanger model, constant temperature and humidity chamber, fan and measurement systems for temperature, pressure and flow rate. Thermal performance and pressure loss of the paper heat exchanger are measured and compared at various air velocities and outdoor conditions. Experimental results show that paper heat exchanger can recover $50{\sim}70%$ of the enthalpy difference between supply and exhaust air.

  • PDF

시뮬레이션을 통한 노인 요양 시설의 지열 히트펌프 시스템 적용 가능성 평가 (Evaluating the Feasibility of a Ground Source Heat pump System for an Elderly Care Center through Simulation Approach)

  • 손병후;김영선;이승언
    • 한국지열·수열에너지학회논문집
    • /
    • 제19권4호
    • /
    • pp.39-52
    • /
    • 2023
  • This study analyzes the energy performance of a elderly care center building and the applicability of a ground source heat pump (GSHP) system through simulation approach. For this purpose, a building information modeling (BIM) program and an energy performance calculation program were used. The impact of the mechanical ventilation system on the energy requirements of the heating and cooling system and the indoor environment was also analyzed, focusing on the change in indoor carbon dioxide (CO2) concentration, which is a representative indicator of the indoor environment (air quality). The simulation results showed that the target building exceeds Level 7 in terms of simulated primary energy consumption or actual energy consumption. In addition, it was analyzed that the target building could not maintain the indoor CO2 concentration below the standard concentration by natural ventilation through window opening alone. Combining the GSHP system with the mechanical ventilation system (Case B and Case C) can further reduce the overall energy consumption by reducing the amount of outdoor air introduced by opening windows. The cost savings compared to the baseline case are estimated to be 67.3% for Case A, 63.7% for Case B, 65.5% for Case C, and 42.5% for Case D. It is necessary to analyze the impact of various renewable energy technologies and passive ones on the energy performance and indoor environment of elderly care centers.

완주군 경로당의 실내환경과 이용자들의 특성 및 만족도 (Indoor Environment and Characteristics and Satisfaction of Users of Senior Centers in Wanju County)

  • 정인수;맹상위
    • 한국농촌건축학회논문집
    • /
    • 제19권1호
    • /
    • pp.23-34
    • /
    • 2017
  • The purpose of this paper is to suggest the preliminary data for the improvement of the senior centers' indoor environment and the upcoming progress located in rural areas. In wanju county, 81.8% of seniors were enrolled in senior centers, and used the facility everyday. Also, most of the users tended to use the facilities between 12 a.m. and 6 p.m. The majority of users had lunch at the senior centers. The facilities of most senior centers were in poor condition, and some had their restroom outdoor. Also, most senior centers are exposed to high concentrations of carbon dioxide during winter. During this season, the thermal environment in the restroom was bad. However, the users' level of the facilities' satisfaction was positive. Senior centers have been operating the facilities with difficulties, due to the low financial support from the local autonomous organization. The indoor temperature in most centers, especially, was above $30^{\circ}C$ during summer on account of lack of funding for airconditioning. Therefore, it could be recommended that the local autonomous entity start regular check-ups and repairs for the poor indoor environment and facilities, with more financial support and active supervision of the management.

지하에 위치한 방사선종양학과에서의 실내공기 질 평가 (Evaluation of Indoor Air Quality in a Department of Radiation Oncology Located Underground)

  • 김원택;신용철;강동묵;기용간;김동원;권병현
    • Radiation Oncology Journal
    • /
    • 제23권4호
    • /
    • pp.243-252
    • /
    • 2005
  • 목적: 지하에 위치한 방사선치료 관련시설 내의 실내공기 질은 근무자뿐만 아니라 장기간 치료받는 환자들의 건강에도 중요하다. 저자들은 근무자들의 빌딩증후군 증상유무의 확인과 함께 실내공기 질과 관련된 여러 인자들을 측정, 분석하여 그 원인을 찾고 해결책을 제시하고자 하였다. 대상 및 방법: 근무자들을 대상으로 자각증상 및 근무환경 인식과 관련된 설문조사를 하였고, 예비조사를 바탕으로 실내공기 질과 관련된 항목들(온 습도, 미세먼지, 이산화탄소, 일산화탄소, 포름알데히드, 총휘발성유기화합물, 라돈)에 대해 근무자들이 주로 머무르는 지역들을 중심으로 일정기간 측정하였다. 아울러 환기(공조) 시스템의 효율 및 주변 환경에 대한 평가를 동시에 진행하였으며, 실외공기와의 비교평가를 위해 1층(실외)에서도 같은 항목들을 측정하였고, 측정 자료들은 국내외 환경관련 기관들의 권고 수치를 기준으로 각각 평가하였다. 결과: 설문조사에서 근무자들은 악취, 습도, 먼지 등에 대해 불만족을 보였으며, 근골격계 증상, 신경계 증상, 점막 자극 증상 등을 주로 호소하였다. 대부분의 실내공기 질 관련 항목들은 기준치를 넘지 않았으나 총휘발성유기화합물 수치가 기존 미국 사무실 측정 수치에 비해 $3{\sim}4$배 높게 나왔다. 환기 횟수나 환기량에서는 문제가 없었으나 실외공기 유입구와 실내공기 배출구의 위치 문제로 인해 오염된 공기의 유입 가능성이 있었다. 총휘발성유기화합물을 배출할 수 있는 현상액과 같은 화학물질의 관리에 주의가 필요했으며, 오염된 공기의 재유입 문제를 해결하기 위해 환기 시스템의 위치조정이 시급한 상황이었다. 결론: 저자들은 실내공기 질에 대한 평가에서 일부 화학물질 및 부적절한 환기 시스템으로 인해 근무자들이 주관적인 증상을 호소할 수 있음을 확인하였다. 지하 공간에서 장시간 거주하는 근무자들의 근무여건 개선과 함께 면역저하를 동반한 환자들의 건강관리를 위해 실내공기 질에 대한 평가는 반드시 필요하며, 그 자료를 바탕으로 향후 방사선종양학과의 설계나 기존 시설의 환경개선 등에 적극적으로 이용해야 하겠다.

솔잎추출물을 혼입한 시멘트 경화체의 항균류 저항 특성 (Antimicrobial Properties of Cement Matrix using Pine Needle Extract)

  • 김호진;정현의;임동현;한송이;박선규
    • 한국건설순환자원학회논문집
    • /
    • 제10권1호
    • /
    • pp.117-123
    • /
    • 2022
  • 현대인은 대부분의 시간을 실내에서 보내고 있기 때문에 실내 공기질에 대한 관심이 높아지는 추세이다. 실내 공기의 주요 오염원으로는 인간의 활동, 건축자재, 생활용품, 외부로부터 오염된 대기의 유입 등을 들 수 있다. 실내 공기질 관리법에서는 실내공기 오염물질로 미세먼지, 총 부유세균, 곰팡이, 이산화탄소 등 17종을 규정하고 있다. 현대인의 실내 환경은 세균과 곰팡이균의 생육환경이 흡사하기 때문에 일상생활에서 세균과 곰팡이에 항상 노출된다. 특히 많은 사람이 모이는 다중이용시설의 경우에는 세균감염의 위험이 더 크다고 할 수 있다. 한편 솔잎은 예전부터 항균효과가 뛰어난 것으로 알려져 있으며, 한약재, 식용 등 쓰임새가 다양하다. 그 외에 의약, 식품 및 염색제 관련 산업에서는 적극적으로 활용하고 있으며, 최근에는 건축자재로 이용하기 위한 시도도 이루어지고 있는 실정이다. 솔잎의 항균효과에 관한 연구는 상당히 많이 이루어지고 있으며, 다양한 항균 성분을 가지고 있다. 따라서 본 연구는 솔잎 추출물의 항세균, 항곰팡이 효과를 확인하였으며, 이를 토대로 솔잎 추출물을 혼입한 시멘트 경화체를 제작해 솔잎 추출물의 혼입 비율별 세균과 곰팡이에 대한 항균 활성 효과를 연구하였다. 솔잎 추출물은 황색포도상구균과 대장균에 대해 항세균 효과를 나타났으며, 검정 곰팡이에 대해 생육환경을 저해하는 것이 나타났다. 솔잎 추출물을 혼입한 시멘트 경화체는 황색포도상구균과 대장균에 대해서 항균 활성 효과를 나타냈다. 그러나 검정 곰팡이에 대해서 항균 활성 효과를 나타내지 않았다. 결과적으로, 솔잎추출물을 혼입한 시멘트 경화체는 병원균 억제에는 효과적이지만 곰팡이에 대해서는 효과가 없는 것으로 판단되며, 솔잎추출물을 항균재료 사용하기 위해서는 곰팡이의 생육을 저해하는 요인에 대한 추가적인 연구가 필요할 것으로 판단된다.

서울시 지하철 2호선의 가을철 객실 PM2.5 농도의 특성 (Characteristics of In-cabin PM2.5 Concentration in Seoul Metro Line Number 2 in Autumn)

  • 신혜린;정현희;이기영
    • 한국환경보건학회지
    • /
    • 제45권2호
    • /
    • pp.186-191
    • /
    • 2019
  • Objectives: Subway is one of the most common transportation modes in Seoul, Korea. The objectives of this study were to determine characteristics of in-cabin $PM_{2.5}$ concentration in Seoul Metro Line Number 2 and to identify factors of the $PM_{2.5}$ concentration. Methods: In-cabin $PM_{2.5}$ concentrations in Seoul Metro Line Number 2 were measured using real-time monitors and the factors affecting $PM_{2.5}$ concentration in cabin were observed. Linear regression analysis of in-cabin $PM_{2.5}$ concentration and indoor/outdoor (I/O) ratio were performed. Results: In-cabin $PM_{2.5}$ concentration was associated with the in-cabin $PM_{2.5}$ concentration in previous station. In-cabin $PM_{2.5}$ concentration was correlated with ambient $PM_{2.5}$ concentration and associated with underground station with control of the in-cabin $PM_{2.5}$ concentration in previous station. I/O ratio increased as the number of passengers increased and when passing through the underground station with control of I/O ratio in previous station. Conclusion: In-cabin $PM_{2.5}$ concentration was affected by ambient $PM_{2.5}$ concentration. Therefore, management of in-cabin $PM_{2.5}$ concentrations should be based on outdoor air quality.

실공간 사용 공기조화기용 열교환기의 공기측 파울링 특성 예측 (Prediction of Characteristics for the Air-side Particulate Fouling in Finned-Tube Heat Exchangers of Air Conditioners used in the Field)

  • 안영철;정성학;황유진;이창건;김두현;정성일;이재근
    • 설비공학논문집
    • /
    • 제19권8호
    • /
    • pp.563-568
    • /
    • 2007
  • The air-side particulate fouling in the heat exchangers of HVAC applications degrades the performances of cooling capacity, pressure drop across a heat exchanger, and indoor air quality. Indoor and outdoor air contaminants foul heat exchangers. An empirical modeling equation has been derived from the experimental results using accelerated tests and it showed good predictions of the fouling characteristics of the slitted finned tube heat exchangers. However the modeling equation predicts only the fouling characteristics of new heat exchangers and it can not predicts fouling characteristics obtained from actual field data which contains the effect of hydrophilicity deterioration. Therefore an modified modeling equation is proposed and it shows good predictions of the actual fouling characteristics of finned-tube heat exchangers.

IoT 기반 지하역사 내 바이오필터시스템 설치에 따른 실내공기질 변화 및 영향 요인 분석 (Analysis of Changes and Factors Influencing IAQ in Subway Stations Using IoT Technology after Bio-Filter System Installation)

  • 양호형;김형주;방성원;조흔우;김호현
    • 한국환경보건학회지
    • /
    • 제47권5호
    • /
    • pp.410-424
    • /
    • 2021
  • Background: Subway stations have the characteristics of being located underground and are a representative public-use facility used by an unspecified number of people. As concerns about indoor air quality (IAQ) increase, various management measures are being implemented. However, there are few systematic studies and cases of long-term continuous measurement of underground station air quality. Objectives: The purpose of this study is to analyze changes and factors influencing IAQ in subway stations through real-time continuous long-term measurement using IoT-based IAQ sensing equipment, and to evaluate the IAQ improvement effect of a bio-filter system. Methods: The IAQ of a subway station in Seoul was measured using IoT-based sensing equipment. A bio-filter system was installed after collecting the background concentrations for about five months. Based on the data collected over about 21 months, changes in indoor air quality and influencing factors were analyzed and the reduction effect of the bio-filter system was evaluated. Results: As a result of the analysis, PM10, PM2.5, and CO2 increased during rush hour according to the change in the number of passengers, and PM10 and PM2.5 concentrations were high when a PM warning/watch was issued. There was an effect of improving IAQ with the installation of the bio-filter system. The reduction rate of a new-bio-filter system with improved efficiency was higher than that of the existing bio-filter system. Factors affecting PM2.5 in the subway station were the outdoor PM2.5, platform PM2.5, and the number of passengers. Conclusions: The IAQ in a subway station is affected by passengers, ventilation through the air supply and exhaust, and the spread of particulate matter generated by train operation. Based on these results, it is expected that IAQ can be efficiently improved if a bio-filter system with improved efficiency is developed in consideration of the factors affecting IAQ and proper placement.

주택 실내환경 VOCs의 발생량 및 감소량에 관한 연구 (A Study of Development of Evaluation on Source Strength and Deposition Constant of VOCs)

  • 정순원;양원호;김대선;송미라;손부순
    • 한국환경과학회지
    • /
    • 제16권9호
    • /
    • pp.1019-1026
    • /
    • 2007
  • This study was performed in 30 selected apartments in Seoul, Asan and Daegu area which were constructed within 4 years and over 4 years, to measure the concentration of VOCs(benzene, toluene, xylene) from July, 2004 to September. Mean ratios of indoor to outdoor VOCs concentrations in the construction under 4 years were higher in 1 than average, I/O ratio of over 4 years were lower in 1. This was considered that the VOCs density influences indoor pollutant. For the indoor air quality estimation, the deposition constant and the source strength factor of toluene were $1.49{\pm}2.05\;hr^{-1}\;and\;36.95{\pm}52.26\;ppb/h$, respectively.

겨울철 서울시 일부 실내스포츠시설에서 금연정책 실시 전후 PM2.5 농도 비교 (Comparison of PM2.5 Concentrations before and after Smoke-free Policy in Some Indoor Sports Facilities in Seoul)

  • 김윤지;이기영;김승원
    • 한국환경보건학회지
    • /
    • 제44권3호
    • /
    • pp.267-274
    • /
    • 2018
  • Objectives: This study examined the impact of a smoke-free policy on indoor air quality at indoor recreation facilities by assessing $PM_{2.5}$ concentrations before and after the implementation of the new policy. Methods: Using real-time monitors, $PM_{2.5}$ concentrations were measured in 50 billiard rooms and 50 golf simulator rooms in Seoul, Korea. The characteristics of the indoor recreation facilities, smoking status, and atmospheric conditions were recorded at the same time.After the enforcement of a smoke-free policy, $PM_{2.5}$ concentrations, installation of smoking room, and smoking status were examined when the facilities were revisited. Results: Almost a half of the billiard rooms and over 80% of golf simulator rooms were located underground. Seventy percent of the billiard rooms and one hundred percent of the golf simulator rooms were equipped with a local exhaust ventilation system. After the implementation of the smoke-free policy, 46% of the billiard rooms and 20% of the golf simulator rooms newly installed a smoking room. In the billiard rooms with a newly-installed smoking room, the $PM_{2.5}$ concentrations decreased from 97.9 to $45.6{\mu}g/m^3$ after the implementation of the smoke-free policy. The same change of 29.0 to $ 26.3{\mu}g/m^3$ was not statistically significant in golf simulator rooms. Indoor $PM_{2.5}$ concentrations were correlated with outdoor $PM_{2.5}$ concentrations, number of smokers, and number of people in the room. Conclusions: The smoke-free policy for indoor recreation facilities was not effective at making the indoor spaces free from second hand smoke. Although a few billiard rooms installed a smoking room, indoor $PM_{2.5}$ concentrations were still higher than those of outdoor $PM_{2.5}$ or atmospheric $PM_{2.5}$. Stricter enforcement of the smoke-free policy should be achieved to prevent secondhand smoke exposure.