• Title/Summary/Keyword: Indoor-air

Search Result 2,362, Processing Time 0.029 seconds

Performance Evaluation of a Portable GC for Real-time Monitoring of Volatile Organic Compounds (휘발성 유기화합물의 실시간 모니터링을 위한 휴대형 GC의 성능 평가)

  • You, Dong-Wook;Seon, Yeong-Sik;Oh, Jun-Sik;Yi, Bongyoon;Kim, Hyun Sik;Jung, Kwang-Woo
    • Journal of the Korean Chemical Society
    • /
    • v.64 no.6
    • /
    • pp.327-333
    • /
    • 2020
  • Performance of a portable GC that can be utilized for the real time determination of volatile organic compounds in air was evaluated. It employs purified/compressed ambient air as the carrier gas eliminating the need for high pressure gas tanks. The compact system with dimensions of 35 × 26 × 15 ㎤ and weight of 5 kg is powered by either a 24 V DC external adapter or battery pack. Chromatograms of the mixture sample including benzene, toluene, ethylbenzene, and oxylene at concentrations of 1 ppmv and 20 ppmv represent a good reproducibility: 3.79% and 0.48% relative standard deviations (RSDs) for peak area variations; 0.40% and 0.08% RSDs for retention times. The method detection limit was 0.09 ppmv. A 30 m long, 0.28 mm I.D. column operated at an optimal condition yielded a peak capacity of 61 with good resolution for a 10 min isothermal analysis. The relative standard deviations (RSD) of the peak area variations and retention times during consecutive measurements over 27 h were less than 2.4%RSD and 0.5%RSD, respectively. Thus, this instrument makes it suitable for continuous and field analysis of low-concentration VOC mixtures in the indoor/outdoor environment as well as the spillage accident of hazardous chemicals.

Reviews on an Improvement and Measurement of the Hydrophobicity for Carbon Materials (탄소재료의 소수성 향상 방법 및 측정 방법에 대한 고찰)

  • Kang, Yu-Jin;Kim, Yu-Jin;Jang, Min-Hyeok;Jo, Hyung-Kun;Yoon, Seong-Jin;Han, Gyoung-Jae;Cho, Hye-Ryeong;Seo, Dong-Jin;Park, Joo-Il
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.30 no.4
    • /
    • pp.41-50
    • /
    • 2022
  • Recently, research on carbon adsorbents has been active as an interest in improving the environment such as indoor and outdoor air quality. Considering that causative substances deteriorate the air quality are basically volatile organic compounds, it is important to improve the hydrophobicity of the carbon materials for better removal efficiency. This study presents a method for improving hydrophobicity of carbon and a measurement of the hydrophobicity. Generally, methods of improving the hydrophobicity of carbon materials are heat treatment, acid/alkali treatment, coating and immersion with hydrophobic materials. However, it collapses the pore structure and reduces the adsorption capacity. Therefore, this study briefly introduce not only the general method for improving carbon materials' hydrophobicity but also the method for converting the precursor of the material is briefly introduced. Futhermore, this study introduces a analytical technique used to determine hydrophobic modification or not, and aims to enhance the understanding of carbon materials.

A study on the 3-step classification algorithm for the diagnosis and classification of refrigeration system failures and their types (냉동시스템 고장 진단 및 고장유형 분석을 위한 3단계 분류 알고리즘에 관한 연구)

  • Lee, Kangbae;Park, Sungho;Lee, Hui-Won;Lee, Seung-Jae;Lee, Seung-hyun
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.8
    • /
    • pp.31-37
    • /
    • 2021
  • As the size of buildings increases due to urbanization due to the development of industry, the need to purify the air and maintain a comfortable indoor environment is also increasing. With the development of monitoring technology for refrigeration systems, it has become possible to manage the amount of electricity consumed in buildings. In particular, refrigeration systems account for about 40% of power consumption in commercial buildings. Therefore, in order to develop the refrigeration system failure diagnosis algorithm in this study, the purpose of this study was to understand the structure of the refrigeration system, collect and analyze data generated during the operation of the refrigeration system, and quickly detect and classify failure situations with various types and severity . In particular, in order to improve the classification accuracy of failure types that are difficult to classify, a three-step diagnosis and classification algorithm was developed and proposed. A model based on SVM and LGBM was presented as a classification model suitable for each stage after a number of experiments and hyper-parameter optimization process. In this study, the characteristics affecting failure were preserved as much as possible, and all failure types, including refrigerant-related failures, which had been difficult in previous studies, were derived with excellent results.

Investigation on the SARS-CoV-2 RNA and PM-2.5 inside Public Transportations in Seoul (서울시 대중교통 내 SARS-CoV-2 RNA와 PM-2.5 오염도 실증연구)

  • Seo, Minjeong;Hong, Juhee;Rhee, Hojun;Park, Jinsol;Lim, Hakmyeong;Park, Myung Kyu;Min, Byungchul;Park, Eun Sun;Lee, Sanghoon;Kim, Hanjun;Ha, Kwangtae;Kwon, Seungmi;Shin, Jinho;Lee, Jaein;Hwang, Youngok;Oh, Younghee;Shin, Yongseung
    • Particle and aerosol research
    • /
    • v.18 no.2
    • /
    • pp.23-35
    • /
    • 2022
  • Recently, passengers using public transport are concerned about the effects of COVID-19 and fine dust. Therefore, from February 2020 to February 2021, we investigated whether SARS-CoV-2 RNA was detected even after disinfection in 55 public transportation places visited by confirmed patients in Seoul. 34 air samples and 702 object surface samples were collected and tested with RT-PCR, one surface sample was positive. In addition, preemptive investigations were conducted in 22 subway trains that passengers were being on board at that time. 1,018 preemptive tests were performed, and all were negative. Although PM-2.5 is dangerous in itself, it can be a potential carrier of viruses. It seemed that a solution was needed as one line continuously exceeded the criteria of PM-2.5. Through this study, it is judged that cluster infection in public transportation can be prevented if efforts to reduce the concentration of fine dust, appropriate disinfection management, and personal disinfection such as wearing a mask in public transportations.

Public Exposure to Natural Radiation and the Associated Increased Risk of Lung Cancer in the Betare-Oya Gold Mining Areas, Eastern Cameroon

  • Joseph Emmanuel Ndjana Nkoulou II;Louis Ngoa Engola;Guy Blanchard Dallou;Saidou;Daniel Bongue;Masahiro Hosoda;Moise Godefroy Kwato Njock;Shinji Tokonami
    • Journal of Radiation Protection and Research
    • /
    • v.48 no.2
    • /
    • pp.59-67
    • /
    • 2023
  • Background: This study aims to reevaluate natural radiation exposure, following up on our previous study conducted in 2019, and to assess the associated risk of lung cancer to the public residing in the gold mining areas of Betare-Oya, east Cameroon, and its vicinity. Materials and Methods: Gamma-ray spectra collected using a 7.62 cm×7.62 cm in NaI(Tl) scintillation spectrometer during a car-borne survey, in situ measurements and laboratory measurements performed in previous studies were used to determine the outdoor absorbed dose rate in air to evaluate the annual external dose inhaled by the public. For determining internal exposure, radon gas concentrations were measured and used to estimate the inhalation dose while considering the inhalation of radon and its decay products. Results and Discussion: The mean value of the laboratory-measured outdoor gamma dose rate was 47 nGy/hr, which agrees with our previous results (44 nGy/hr) recorded through direct measurements (in situ and car-borne survey). The resulting annual external dose (0.29±0.09 mSv/yr) obtained is similar to that of the previous study (0.33±0.03 mSv/yr). The total inhalation dose resulting from radon isotopes and their decay products ranged between 1.96 and 9.63 mSv/yr with an arithmetic mean of 3.95±1.65 mSv/yr. The resulting excess lung cancer risk was estimated; it ranged from 62 to 216 excess deaths per million persons per year (MPY), 81 to 243 excess deaths per MPY, or 135 excess deaths per MPY, based on whether risk factors reported by the U.S. Environmental Protection Agency, United Nations Scientific Committee on the effects of Atomic Radiation, or International Commission on Radiological Protection were used, respectively. These values are more than double the world average values reported by the same agencies. Conclusion: There is an elevated level of risk of lung cancer from indoor radon in locations close to the Betare-Oya gold mining region in east Cameroon. Therefore, educating the public on the harmful effects of radon exposure and considering some remedial actions for protection against radon and its progenies is necessary.

The Impact of Negative Ions and Plant Volume Changes in Space on Fine Dust Purification in the Atmosphere (공기 중 음이온과 공간 내 식물용적 변화가 미세먼지 정화에 미치는 영향)

  • Deuk-Kyun Oh;Jeong-Ho Kim
    • Korean Journal of Environment and Ecology
    • /
    • v.38 no.2
    • /
    • pp.217-226
    • /
    • 2024
  • This study aimed to investigate the influence of anions in the air on the purification of fine dust (PM10 and PM2.5) and to evaluate the effects of plants on the generation of anions in the air and the purification of fine dust. Subsequently, the fine dust reduction models were compared according to each factor and plant volume. The characteristics of anion generation by each factor were observed to be in the order of Type N.I (negative ion generator; 204,133.33 ea/cm3) > Type P30 (plant vol. 30%; 362.55 ea/cm3) > Type C (control; 46.22 ea/cm3), indicating that the amount of anion generation in the anion generator treatment group and the plant arrangement group were approximately 4,417 times and 7 times higher, respectively, than that in the untreated group. Consequently, the fine dust reduction characteristics by anion generation source showed that for PM10, Type NI had a purification efficiency 2.52 times higher than Type C, and Type P30 was 1.46 times higher, while for PM2.5, Type NI had a purification efficiency 2.26 times higher than Type C, and Type P30 was 1.31 times higher. The efficiency of fine dust purification by plant volume was in the order of Type P20 (84.60 minutes) > Type P30 (106.50 minutes) = Type P25 (115.50 minutes) = Type P15 (117.60 minutes) > Type P5 (125.25 minutes) = Type P10 (129.75 minutes), and for ultrafine dust, Type P20 (104.00 minutes) > Type P30 (133.20 minutes) = Type P25 (144.00 minutes) = Type P15 (147.60 minutes) > Type P5 (161.25 minutes) = Type P10 (168.00 minutes). Thus, a quantitative analysis of the anions and plants for purifying fine dust and suggested matters to be considered for future green space planning and plant planting considering fine dust purification.

An Analysis of Thermal Comforts for Pedestrians by WBGT Measurement on the Urban Street Greens (도심 가로 녹음의 습구흑구온도(WBGT) 측정을 통한 보행자 열쾌적성 효과 분석)

  • Ahn, Tong-Mahn;Lee, Jae-Won;Kim, Bo-Ram;Yoon, Ho-Seon;Son, Seung-Woo;Choi, Yoo;Lee, Na-Rae;Lee, Ji-Young;Kim, Hae-Ryung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.41 no.3
    • /
    • pp.22-30
    • /
    • 2013
  • This study aims to measure the thermal comfort effects of urban street trees. As the usual dry bulb air temperature does not indicate properly how the average pedestrian feels the heat of a typical summer day under the strong sunshine, we adopted the Wet Bulb Globe Temperature(WBGT). WBGT involves black globe temperature to measure the direct radiation of sun beams on our bodies, for example our heads. We measured temperatures on very sunny and hot summer days, August 3, 4, and 7, 2012, on the urban streets of Seoul, Korea. Wet bulb, globe, and dry bulb temperatures were measured under direct sunlight from 1 O'clock to 5 O'clock pm. Globe and dry bulb temperatures were measured under street tree shades nearby during the same hours. Then the WBGTs were calculated with the formulae, one for sunny outdoor spaces, and the other for shaded outdoor spaces or indoor. The results are compared with the Korean Standards Association(KS A ISO 7243). The major findings were: 1) On very sunny and hot summer days in Seoul, street tree shades lower the WBGT about 1 to 4 degrees, 2) during the hours of 3 and 4 O'clock in the afternoon, the WBGT under the tree shades are about 3 to 4 degrees lower compared to those under sunshines(approx. 29 to 32 degrees respectively), 3) This difference makes a major thermal comfort for urban pedestrians because senior citizens or weak persons are recommended to move indoor, and even healthy people are recommended stop outdoor sports and take rests in the shades when WBGT is about 32. On the other hand, if the WBGT is around 29, or 3 degrees lower, slower walking, light works or sports are allowable, 4) On site questionnaire survey confirms the thermal comforts under the tree shades, and we even could not get survey subjects on the sunny parts of the sidewalks, 5) We strongly recommend change of guidelines for urban street trees from "one row of street trees on 6m~8m intervals" to "street trees to make continuous shades".

Study on the Environmental Factors and Symptoms of VDT Syndrome (VDT 증후군의 환경적 요인과 증상에 대한 연구)

  • Jeong, Seunghui;Lee, Seon Young;Eu, Sun Mi;Kim, Douk-Hoon;Lee, Eun-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.4
    • /
    • pp.65-69
    • /
    • 2009
  • Purpose: Recently incidence of VDT syndrome has gradually increased as extensive use of computers. VDT syndrome reported by VDT workers include musculoskeletal disorder, neuropsychiatric disoders and eye symptoms such as eye strain, tired eyes, irritation and blurred vision. The environmental factors of VDT syndrome include electromagnetic waves, size, brightness and lighting of computer screen, height of a monitor and a worktable, working hours, kind of task, distance between screen and workers, indoor humidity and temperature, indoor air contamination and ventilation. In this study, we investigated the environmental factors related to body symptoms and health effects included in VDT syndrome. Methods: Study subjects were total 120 persons (54 male, 66 female) with age from 19 to 28. We surveyed the body symptoms and physical discomfort when doing an activity in a short distance such as reading book or paper, computer work. The questionnaire included main body symptoms, self-consciousness symptoms of eye, satisfaction of working environment, pain of the wrist when using keyboard and mouse. Results: Most of people (70%) felt physical pain from long time work of computer, paper, electrical apparatus. They mainly complained pain of neck and low back (57.1%), eye (45.2%) and head (31%). With the environmental factors, 78.3% of the subjects complaint pain of eye from inappropriate illumination. Most of the symptoms included 'eye fatigue'(38.3%), 'dryness of eye'(31.9%) and 'blurred vision'(23.7%). Subjects in this study complained discomfort of their chairs and most of them experienced pain in the wrist when using keyboard or mouse. Conclusions: When people use electrical apparatus or work with paper, people would get their eye fatigue and feeling of physical fatigue because of not harmonizing various environmental factors such as light, space, posture, worktable with theirselves. Therefore, workers should develop preventive method such as self-control of adequate break time to avoid fatigue while VDT work. Work environment should be changed to ergonomic design for optimal visual environment to prevent musculoskeletal disorder through constant research.

  • PDF

A Study on the Production of Artificial Seed and Intermediate culture for Attached Spats of the Chinese Stock of a Scallop, Patinopecten yessoensis (중국산 참가리비, Patinopecten yessoensis의 인공종묘 생산 및 부착치패 중간양성에 관한 연구)

  • Oh, Bong-Se;Lee, Jeong-Yong;Park, Se-Ku;Lee, Chu;Jo, Q-Tae
    • The Korean Journal of Malacology
    • /
    • v.24 no.2
    • /
    • pp.153-159
    • /
    • 2008
  • We investigated artificial mass seed production of a Chinese scallop, Patinopecten yessoensis, in 2004. The GSI(gonad somatic index) of the Chinese scallop, P yessoensis was 17.2 on mid-February, 20.2 on mid-March, while that of Korean scallop, P yessoensis was 6.9 on mid-February, 10.8 on mid-March. Matured 120 females and 350 males were selected for artificial mass production. They were exposed in air for 1 hr at over $20^{\circ}C$, and placed into a spawning tank(20 ton) containing sea water treated with UV radiation at $12^{\circ}C$. We gained a total of 228,000 thousand scallop embryos between March 10th and 15th, and reared larvae at the indoor tank during 25 days. When the mean shell length of larvae reached 250 ${\mu}m$ and they have eye-spots, the number of pre-settling larvae was 47,500 thousand. We gained 1,850 thousand attached scallop spats from two kinds of collectors. Attached spats were reared in indoor tank for different periods from 5 days to 60 days. They were divided into 5 groups according to the length of reared days. Each group of attached spats was moved to intermediate rearing sites at Yangyang fishing port in Gangreung-city for acclimation to ocean environments. The highest survival rate of attached spats was 13.0% shown at the group reared for 12 days, but the significant difference in their growth was not found between the groups. The shell length of artificial attached spats increased from 0.9 ${\mu}m$ on July 10th to 24.7 ${\mu}m$ on December 16th with the survival rate of 85.0% while that of natural attached spats increased from 0.6 ${\mu}m$ on July 10th to 23.9 ${\mu}m$ on December 16th with the survival rate of 85.7%.

  • PDF

Analyses of CO2 Concentration and Balance in a Closed Production System for King Oyster Mushroom and Lettuce (밀폐형 식물생산시스템 내 새송이 버섯과 상추의 혼합 재배 비율에 따른 CO2 농도 변화 및 균형 분석)

  • Jung, Dae Ho;Kim, Chan Kyo;Oh, Kyung Hun;Lee, Dong-Hyeon;Kim, Minsu;Shin, Jong Hwa;Son, Jung Eek
    • Horticultural Science & Technology
    • /
    • v.32 no.5
    • /
    • pp.628-635
    • /
    • 2014
  • The large amount of $CO_2$ emitted from mushrooms during incubation and developmental stages can be utilized in plant production systems as a $CO_2$ source. The objectives of this study were to measure the $CO_2$ emission and absorption rates of mushroom and lettuce, respectively, and to analyze the $CO_2$ concentrations at various ratios of mushroom and lettuce in a closed production system. The $CO_2$ emission rate of king oyster mushrooms (Pleurotus eryngii ( DC.) Qu$\acute{e}$l) and $CO_2$ absorption rate of lettuces (Lactuca sativa L. cv. Asia Heuk Romaine) were measured by using two closed acryl chambers ($1.0m{\times}0.8m{\times}0.5m$) in which indoor temperatures were maintained at $18^{\circ}C$ and $22^{\circ}C$, respectively. The lettuce was grown at a light intensity of PPF $340mol{\cdot}m^{-2}{\cdot}s^{-1}$ and with nutrient solution at EC $1.2dS{\cdot}m^{-1}$. The air was periodically circulated between the two chambers using a diaphragm pump. The $CO_2$ emission rate of the mushroom increased until the $15^{th}$ day after scratching (DAS) and then decreased. The rate also increased with increased indoor temperature. In particular, the $CO_2$ emission rate per fresh weight of fruit body increased by about 3.1 times after thinning compared to before thinning. In terms of $CO_2$ balance, the $CO_2$ emission rates from a bottle (950 mL) of the mushroom at 9, 12, and 14 DAS were equivalent to those of 3, 4.5, and 5.5 lettuce plants at 7, 10, and 12 DAT (days after transplanting), respectively. This work shows that balance in $CO_2$ concentration could be achieved using an appropriate ratio of the two crops in a closed production system.